class WaitForFlatFieldFiberPos(KPFTranslatorFunction):
'''Wait for the flat field fiber aperture via the `kpfcal.FF_FIBERPOS`
keyword.
Args:
FF_FiberPos (str): The name of the flat field fiber position desired.
Allowed Values: "Blank", "6 mm f/5", "7.5 mm f/4", "10 mm f/3",
"13.2 mm f/2.3", "Open".
wait (bool): Wait for move to complete before returning? default: True
## KTL Keywords Used
- `kpfcal.FF_FIBERPOS`
'''
@classmethod
def pre_condition(cls, args, logger, cfg):
keyword = ktl.cache('kpfcal', 'FF_FiberPos')
allowed_values = list(keyword._getEnumerators())
if 'Unknown' in allowed_values:
allowed_values.pop(allowed_values.index('Unknown'))
check_input(args, 'FF_FiberPos', allowed_values=allowed_values)
@classmethod
def perform(cls, args, logger, cfg):
target = args.get('FF_FiberPos')
timeout = cfg.getfloat('times', 'nd_move_time', fallback=20)
expr = f"($kpfcal.FF_FiberPos == '{target}')"
success = ktl.waitFor(expr, timeout=timeout)
if success is False:
log.error(f"Timed out waiting for FF_FiberPos filter wheel")
@classmethod
def post_condition(cls, args, logger, cfg):
target = args.get('FF_FiberPos')
expr = f"($kpfcal.FF_FiberPos == '{target}')"
success = ktl.waitFor(expr, timeout=0.1)
@classmethod
def add_cmdline_args(cls, parser, cfg=None):
parser.add_argument('FF_FiberPos', type=str,
choices=["Blank", "6 mm f/5", "7.5 mm f/4",
"10 mm f/3", "13.2 mm f/2.3", "Open"],
help='Wide flat aperture to use.')