13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212 | class SetOutdirs(KPFTranslatorFunction):
'''Set output directories for all detectors based on the current date.
ARGS:
=====
None
'''
@classmethod
def pre_condition(cls, args, logger, cfg):
pass
@classmethod
def perform(cls, args, logger, cfg):
log.info(f"SetOutdirs invoked")
utnow = datetime.utcnow()
date = utnow-timedelta(days=1)
date_str = date.strftime('%Y%b%d').lower()
outdir = Path(f"/s/sdata1701/{os.getlogin()}/{date_str}")
magiq_outdir = Path(f"/s/sdata1701/kpfguide/{date_str}")
log.debug(f"base outdir: {outdir}")
log.debug(f"magiq outdir: {magiq_outdir}")
if args.get('CRED2', True) is True:
log.info(f"Setting guider OUTDIR to {magiq_outdir}")
guide_outdir = ktl.cache('kpfguide', 'OUTDIR')
try:
guide_outdir.write(f"{magiq_outdir}")
except Exception as e:
log.error(f"ERROR setting guider outdir")
log.error(e)
log.info(f"Setting guider TRIGOUTDIR to {outdir / 'CRED2'}")
trig_outdir = ktl.cache('kpfguide', 'TRIGOUTDIR')
try:
trig_outdir.write(f"{outdir / 'CRED2'}")
except Exception as e:
log.error(f"ERROR setting guider TRIGOUTDIR")
log.error(e)
kpffvc = ktl.cache('kpffvc')
if args.get('FVC1', True) is True:
log.info(f"Setting FVC1 OUTDIR to {outdir / 'FVC1'}")
try:
kpffvc['SCIOUTDIR'].write(f"{outdir / 'FVC1'}")
except Exception as e:
log.error(f"ERROR setting SCI FVC outdir")
log.error(e)
if args.get('FVC2', True) is True:
log.info(f"Setting FVC2 OUTDIR to {outdir / 'FVC2'}")
try:
kpffvc['CAHKOUTDIR'].write(f"{outdir / 'FVC2'}")
except Exception as e:
log.error(f"ERROR setting CAHK FVC outdir")
log.error(e)
# if args.get('FVC3', True) is True:
# log.info(f"Setting FVC3 OUTDIR to {outdir / 'FVC3'}")
# try:
# kpffvc['CALOUTDIR'].write(f"{outdir / 'FVC3'}")
# except Exception as e:
# log.error(f"ERROR setting CAL FVC outdir")
# log.error(e)
# if args.get('FVC4', True) is True:
# log.info(f"Setting FVC4 OUTDIR to {outdir / 'FVC4'}")
# try:
# kpffvc['EXTOUTDIR'].write(f"{outdir / 'FVC4'}")
# except Exception as e:
# log.error(f"ERROR setting EXT FVC outdir")
# log.error(e)
if args.get('ExpMeter', True) is True:
expmeter_outdir = outdir / 'ExpMeter'
log.info(f"Setting exposure meter DATADIR to {expmeter_outdir}")
kpf_expmeter_outdir = ktl.cache('kpf_expmeter', 'DATADIR')
try:
kpf_expmeter_outdir.write(f"{expmeter_outdir}")
except Exception as e:
log.error(f"ERROR setting ExpMeter outdir")
log.error(e)
if args.get('CaHK', True) is True:
cahk_outdir = outdir / 'CaHK'
log.info(f"Setting CaHK RECORDDIR to {cahk_outdir}")
kpf_hk_outdir = ktl.cache('kpf_hk', 'RECORDDIR')
try:
kpf_hk_outdir.write(f"{cahk_outdir}")
except Exception as e:
log.error(f"ERROR setting CaHK outdir")
log.error(e)
if args.get('Green', True) is True:
green_outdir = outdir / 'Green'
log.info(f"Setting Green FITSDIR to {green_outdir}")
kpfgreen_outdir = ktl.cache('kpfgreen', 'FITSDIR')
try:
kpfgreen_outdir.write(f"{green_outdir}")
except Exception as e:
log.error(f"ERROR setting Green outdir")
log.error(e)
if args.get('Red', True) is True:
red_outdir = outdir / 'Red'
log.info(f"Setting Red FITSDIR to {red_outdir}")
kpfred_outdir = ktl.cache('kpfred', 'FITSDIR')
try:
kpfred_outdir.write(f"{red_outdir}")
except Exception as e:
log.error(f"ERROR setting Red outdir")
log.error(e)
if args.get('L0', True) is True:
L0_outdir = outdir / 'L0'
log.info(f"Setting kpfasemble OUTDIR to {L0_outdir}")
kpfassemble_outdir = ktl.cache('kpfassemble', 'OUTDIR')
try:
kpfassemble_outdir.write(f"{L0_outdir}")
except Exception as e:
log.error(f"ERROR setting kpfasemble outdir")
log.error(e)
@classmethod
def post_condition(cls, args, logger, cfg):
utnow = datetime.utcnow()
date = utnow-timedelta(days=1)
date_str = date.strftime('%Y%b%d').lower()
outdir = Path(f"/s/sdata1701/{os.getlogin()}/{date_str}")
tests = []
if args.get('CRED2', True) is True:
expr = f"$kpfguide.OUTDIR == '/s/sdata1701/kpfguide'"
success = ktl.waitFor(expr, timeout=5)
tests.append(success)
if args.get('CRED2', True) is True:
expr = f"$kpfguide.TRIGOUTDIR == '{outdir}/CRED2'"
success = ktl.waitFor(expr, timeout=5)
tests.append(success)
if args.get('FVC1', True) is True:
expr = f"$kpffvc.SCIOUTDIR == '{outdir}/FVC1'"
success = ktl.waitFor(expr, timeout=5)
tests.append(success)
if args.get('FVC2', True) is True:
expr = f"$kpffvc.CAHKOUTDIR == '{outdir}/FVC2'"
success = ktl.waitFor(expr, timeout=5)
tests.append(success)
# if args.get('FVC3', True) is True:
# expr = f"$kpffvc.CALOUTDIR == '{outdir}/FVC3'"
# success = ktl.waitFor(expr, timeout=5)
# tests.append(success)
# if args.get('FVC4', False) is True:
# expr = f"$kpffvc.EXTOUTDIR == '{outdir}/FVC4'"
# success = ktl.waitFor(expr, timeout=5)
# tests.append(success)
if args.get('ExpMeter', True) is True:
expr = f"$kpf_expmeter.DATADIR == '{outdir}/ExpMeter'"
success = ktl.waitFor(expr, timeout=5)
tests.append(success)
if args.get('CaHK', True) is True:
expr = f"$kpf_hk.RECORDDIR == '{outdir}/CaHK'"
success = ktl.waitFor(expr, timeout=5)
tests.append(success)
if args.get('Green', True) is True:
expr = f"$kpfgreen.FITSDIR == '{outdir}/Green'"
success = ktl.waitFor(expr, timeout=5)
tests.append(success)
if args.get('Red', True) is True:
expr = f"$kpfred.FITSDIR == '{outdir}/Red'"
success = ktl.waitFor(expr, timeout=5)
tests.append(success)
if args.get('L0', True) is True:
expr = f"$kpfassemble.OUTDIR == '{outdir}/L0'"
success = ktl.waitFor(expr, timeout=5)
tests.append(success)
return np.all(np.array(tests))
@classmethod
def add_cmdline_args(cls, parser, cfg=None):
parser = cls._add_bool_arg(parser, 'CRED2',
'Set CRED2 OUTDIR (kpfguide.OUTDIR)?', default=True)
parser = cls._add_bool_arg(parser, 'FVC1',
'Set FVC1 OUTDIR (kpffvc.SCIOUTDIR)?', default=True)
parser = cls._add_bool_arg(parser, 'FVC2',
'Set FVC2 OUTDIR (kpffvc.CAHKOUTDIR)?', default=True)
# parser = cls._add_bool_arg(parser, 'FVC3',
# 'Set FVC3 OUTDIR (kpffvc.CALOUTDIR)?', default=True)
# parser = cls._add_bool_arg(parser, 'FVC4',
# 'Set FVC4 OUTDIR (kpffvc.EXTOUTDIR)?', default=True)
parser = cls._add_bool_arg(parser, 'ExpMeter',
'Set ExpMeter OUTDIR (kpf_expmeter.DATADIR)?', default=True)
parser = cls._add_bool_arg(parser, 'CaHK',
'Set CaHK OUTDIR (kpf_hk.RECORDDIR)?', default=True)
parser = cls._add_bool_arg(parser, 'Green',
'Set Green OUTDIR (kpfgreen.FITSDIR)?', default=True)
parser = cls._add_bool_arg(parser, 'Red',
'Set Red OUTDIR (kpfred.FITSDIR)?', default=True)
parser = cls._add_bool_arg(parser, 'L0',
'Set Red OUTDIR (kpfassemble.OUTDIR)?', default=True)
return super().add_cmdline_args(parser, cfg)
|