class TakeFVCExposure(KPFTranslatorFunction):
'''Take an exposure with the specified fiber viewing camera
Args:
camera (str): Which FVC camera? Allowed values: SCI, CAHK, EXT, CAL
wait (bool): Wait for image to complete before returning? (default: True)
display (bool): Display the resulting image to the engineering ds9
instance for FVCs using XPA?
KTL Keywords Used:
- `kpffvc.SCIEXPTIME`
- `kpffvc.CAHKEXPTIME`
- `kpffvc.EXTEXPTIME`
- `kpffvc.CALEXPTIME`
- `kpffvc.SCILASTFILE`
- `kpffvc.CALLASTFILE`
- `kpffvc.EXTLASTFILE`
- `kpffvc.CAHKLASTFILE`
- `kpffvc.SCIEXPOSE`
- `kpffvc.CALEXPOSE`
- `kpffvc.EXTEXPOSE`
- `kpffvc.CAHKEXPOSE`
- `kpfpower.KPFFVC1`
- `kpfpower.KPFFVC2`
- `kpfpower.KPFFVC3`
'''
@classmethod
def pre_condition(cls, args, logger, cfg):
check_input(args, 'camera', allowed_values=['SCI', 'CAHK', 'CAL', 'EXT'])
# Check if power is on
camera = args.get('camera')
camnum = {'SCI': 1, 'CAHK': 2, 'CAL': 3, 'EXT': None}[camera]
if camnum is not None:
powerkw = ktl.cache('kpfpower', f"KPFFVC{camnum}")
if powerkw.read() != 'On':
raise FailedPreCondition(f"{camera}FVC power is not On")
@classmethod
def perform(cls, args, logger, cfg):
camera = args.get('camera')
kpffvc = ktl.cache('kpffvc')
exptime = kpffvc[f'{camera}EXPTIME'].read(binary=True)
lastfile = kpffvc[f'{camera}LASTFILE']
initial_lastfile = lastfile.read()
wait = args.get('wait', True)
kpffvc[f'{camera}EXPOSE'].write('yes', wait=wait)
if wait is True:
timeout = cfg.getfloat('times', 'fvc_command_timeout', fallback=5)
expr = f"($kpffvc.{camera}LASTFILE != '{initial_lastfile}')"
ktl.waitFor(expr, timeout=exptime+timeout)
if wait is True and args.get('display', False) is True:
display_name = cfg.get('display', 'fvc_xpa_target', fallback='FVC')
ds9cmd = ['xpaset', display_name, 'fits', f"{lastfile.read()}",
'<', f"{lastfile.read()}"]
log.debug(f"Running: {' '.join(ds9cmd)}")
subprocess.call(' '.join(ds9cmd), shell=True)
regfile = Path(f'/home/kpfeng/fibers_on_{camera.lower()}fvc.reg')
if regfile.exists() is True:
overlaycmd = ['xpaset', '-p', display_name, 'regions', 'file',
f"{regfile}"]
log.debug(f"Running: {' '.join(overlaycmd)}")
subprocess.call(' '.join(overlaycmd), shell=True)
return kpffvc[f"{camera}LASTFILE"].read()
@classmethod
def post_condition(cls, args, logger, cfg):
camera = args.get('camera', 'SCI')
kpffvc = ktl.cache('kpffvc')
lastfile = kpffvc[f'{camera}LASTFILE']
lastfile.monitor()
new_file = Path(f"{lastfile}")
log.debug(f"{camera}FVC LASTFILE: {new_file}")
if new_file.exists() == False:
raise FailedPostCondition(f'Output file not found: {new_file}')
@classmethod
def add_cmdline_args(cls, parser, cfg=None):
parser.add_argument('camera', type=str,
choices=['SCI', 'CAHK', 'CAL', 'EXT'],
help='The FVC camera')
parser.add_argument("--nowait", dest="wait",
default=True, action="store_false",
help="Send exposure command and return immediately?")
parser.add_argument("--display", dest="display",
default=False, action="store_true",
help="Display image via engineering ds9?")
return super().add_cmdline_args(parser, cfg)