IsSoCalShutDown

Bases: KPFFunction

Returns True if SoCal enclosure is closed and tracker is parked.

KTL Keywords Used:

  • kpfsocal.ENCSTA
  • kpfsocal.EKOHOME
Source code in kpf/socal/IsSoCalShutDown.py
class IsSoCalShutDown(KPFFunction):
    '''Returns True if SoCal enclosure is closed and tracker is parked.

    KTL Keywords Used:

    - `kpfsocal.ENCSTA`
    - `kpfsocal.EKOHOME`
    '''
    @classmethod
    def pre_condition(cls, args):
        pass

    @classmethod
    def perform(cls, args):
        # Enclosure
        timeout = cfg.getfloat('SoCal', 'enclosure_status_time', fallback=10)
        ENCSTA = ktl.cache('kpfsocal', 'ENCSTA')
        is_closed = ENCSTA.waitFor("==1", timeout=timeout)

        EKOHOME = ktl.cache('kpfsocal', 'EKOHOME')
        is_home = EKOHOME.waitFor("==1", timeout=timeout)

        closedstr = {True: '', False: 'NOT '}[is_closed]
        parkedstr = {True: '', False: 'NOT '}[is_home]
        msg = f'SoCal is {closedstr}closed and is {parkedstr}parked'
        print(msg)

        shutdown = is_closed and is_home
        if not shutdown and args.get('email', False) is True:
            try:
                url = 'http://192.168.78.70/camera/index.html#/video'
                msg += f'\n\nSoCal status can be viewed using this camera: {url}'
                SendEmail.execute({'Subject': f'KPF SoCal is not shut down properly',
                                   'Message': msg})
            except Exception as email_err:
                log.error(f'Sending email failed')
                log.error(email_err)

        return shutdown

    @classmethod
    def post_condition(cls, args):
        pass

    @classmethod
    def add_cmdline_args(cls, parser):
        parser.add_argument('--email', dest="email",
                            default=False, action="store_true",
                            help='Send email if SoCal is not shut down?')
        return super().add_cmdline_args(parser)