20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194 | class TakeExpMeterBiases(KPFTranslatorFunction):
'''Take a set of bias frames for the exposure meter.
Obeys kpfconfig.ALLOWSCHEDULEDCALS (will not run if that is set to No)
Args:
nExp (int): The number of frames to take.
combine (bool): Combine the files in to a master bias?
output (str): The output combined bias file.
update (bool): Update the bias file in use with the newly generated
file? (only used if combine is True).
KTL Keywords Used:
- `kpfconfig.EXPMETER_ENABLED`
- `kpfconfig.ALLOWSCHEDULEDCALS`
- `kpf_expmeter.COOLING`
- `kpf_expmeter.COOLTARG`
- `kpf_expmeter.COOLTEMP`
- `kpf_expmeter.BINX`
- `kpf_expmeter.BINY`
- `kpf_expmeter.TOP`
- `kpf_expmeter.LEFT`
- `kpf_expmeter.WIDTH`
- `kpf_expmeter.HEIGHT`
- `kpf_expmeter.EXPOSURE`
- `kpf_expmeter.OBJECT`
- `kpf_expmeter.OBSERVER`
- `kpf_expmeter.EXPMODE`
- `kpf_expmeter.EXPSTATE`
- `kpf_expmeter.EXPOSE`
- `kpf_expmeter.SEQNUM`
- `kpf_expmeter.FITSFILE`
- `kpfexpose.TRIG_TARG`
Scripts Called:
- `kpf.calbench.SetCalSource`
- `kpf.calbench.WaitForCalSource`
- `kpf.spectrograph.WaitForReady`
- `kpf.spectrograph.SetSourceSelectShutters`
- `kpf.expmeter.BuildMasterBias`
- `kpf.spectrograph.ResetDetectors.ResetExpMeterDetector`
'''
@classmethod
@obey_scriptrun
def pre_condition(cls, args, logger, cfg):
check_input(args, 'nExp', allowed_types=[int])
kpf_expmeter = ktl.cache('kpf_expmeter')
# Check exposure meter enabled
kpfconfig = ktl.cache('kpfconfig')
EM_enabled = kpfconfig['EXPMETER_ENABLED'].read() == 'Yes'
if EM_enabled == False:
raise FailedPreCondition('Exposure meter is not enabled')
# Check on exposure meter detector status
if kpf_expmeter['COOLING'].read(binary=True) != True:
raise FailedPreCondition('Exposure meter cooling is not On')
cooltarg = kpf_expmeter['COOLTARG'].read(binary=True)
currtemp = kpf_expmeter['CURRTEMP'].read(binary=True)
deltaT = abs(currtemp-cooltarg)
deltaT_threshold = cfg.getfloat('tolerances',
'expmeter_detector_temperature_tolerance',
fallback=0.5)
if deltaT > deltaT_threshold:
raise FailedPreCondition('Exposure meter not near target temperature')
@classmethod
@register_script(Path(__file__).name, os.getpid())
@add_script_log(Path(__file__).name.replace(".py", ""))
def perform(cls, args, logger, cfg):
# Check if we're ok to take data
allowscheduledcals = ktl.cache('kpfconfig', 'ALLOWSCHEDULEDCALS')
if allowscheduledcals.read(binary=True) == False:
log.warning(f'kpfconfig.ALLOWSCHEDULEDCALS=No. Not taking biases.')
return []
# Proceed with taking biases
nExp = int(args.get('nExp'))
log.info(f"Taking {nExp} exposure meter bias frames")
kpf_expmeter = ktl.cache('kpf_expmeter')
# Set exposure meter to full frame to take biases
log.info(f"Setting exposure meter to full frame for biases")
kpf_expmeter['BINX'].write(1)
kpf_expmeter['BINY'].write(1)
kpf_expmeter['TOP'].write(0)
kpf_expmeter['LEFT'].write(0)
kpf_expmeter['WIDTH'].write(1072)
kpf_expmeter['HEIGHT'].write(1024)
kpf_expmeter['EXPOSURE'].write(0.12)
kpf_expmeter['OBJECT'].write('bias')
kpf_expmeter['OBSERVER'].write('TakeExpMeterBiases')
kpf_expmeter['EXPMODE'].write('Continuous')
log.debug('Set Octagon to Home and close all source select shutters')
SetCalSource.execute({'CalSource': 'Home'})
WaitForReady.execute({})
SetSourceSelectShutters.execute({})
WaitForCalSource.execute({'CalSource': 'Home'})
# Set TRIG_TARG to None, so that kpfassemble doesn't try
# to pick up this data set
trig_targ = ktl.cache('kpfexpose', 'TRIG_TARG')
trig_targ.write('None')
ready = kpf_expmeter['EXPSTATE'].waitFor("== 'Ready'", timeout=60)
if ready is not True:
raise KPFException(f"Exposure Meter did not reach ready state")
# Start continuous exposures
log.info(f"Starting continuous exposures")
kpf_expmeter['EXPOSE'].write('Start')
started = kpf_expmeter['EXPSTATE'].waitFor("!= 'Ready'", timeout=5)
if started is not True:
raise KPFException(f"Exposure Meter did not start exposures")
got_frames = kpf_expmeter['SEQNUM'].waitFor(f"== {nExp}", timeout=2*nExp)
if got_frames is not True:
raise KPFException(f"Exposure Meter did not get all exposures")
log.info(f"Stopping continuous exposures")
kpf_expmeter['EXPOSE'].write('End')
# Arbitrary wait to let file writing and DRP finish
time.sleep(2)
# Get FITSFILE
lastfile = Path(kpf_expmeter['FITSFILE'].read())
if lastfile.exists() is False:
raise KPFException(f"Could not find file: {lastfile}")
filename_parts = lastfile.name.split('.')
filename_parts[1] = '*'
biases = [f for f in lastfile.parent.glob('.'.join(filename_parts))]
# Set exposure meter back to operations settings
log.info(f"Setting exposure meter to operational windowing")
kpf_expmeter['BINX'].write(1)
kpf_expmeter['BINY'].write(1)
kpf_expmeter['TOP'].write(0)
kpf_expmeter['LEFT'].write(1)
kpf_expmeter['WIDTH'].write(651)
kpf_expmeter['HEIGHT'].write(300)
kpf_expmeter['OBJECT'].write('')
if args.get('combine', False) is True:
BuildMasterBias.execute({'files': biases,
'output': args.get('output'),
'update': args.get('update')})
return biases
@classmethod
def post_condition(cls, args, logger, cfg):
expstate = ktl.cache('kpf_expmeter', 'EXPSTATE')
expstate.monitor()
timeout = 60
ready = expstate.waitFor("== 'Ready'", timeout=timeout)
if ready is not True:
log.error(f'ExpMeter is not Ready after {timeout} s')
log.warning(f'ExpMeter is {expstate.ascii}. Resetting.')
ResetExpMeterDetector.execute({})
@classmethod
def add_cmdline_args(cls, parser, cfg=None):
parser.add_argument('nExp', type=int,
help="The number of frames to take")
parser.add_argument("-c", "--combine", dest="combine",
default=False, action="store_true",
help="Combine the files in to a master bias?")
parser.add_argument("--update", dest="update",
default=False, action="store_true",
help="Update the bias file in use with the newly generated file? (only used if --combine is used)")
parser.add_argument("--output", dest="output", type=str,
default='',
help="The output combined bias file.")
return super().add_cmdline_args(parser, cfg)
|