SetReadModeFast

Bases: KPFFunction

Configure both detectors to fast read mode by changing the ACF files they are using.

KTL Keywords Used:

  • kpfgreen.ACFFILE
  • kpfgreen.ACF
  • kpfred.ACFFILE
  • kpfred.ACF

Functions Called:

  • kpf.spectrograph.QueryReadMode
  • kpf.utils.SendEmail
Source code in kpf/spectrograph/SetReadModeFast.py
class SetReadModeFast(KPFFunction):
    '''Configure both detectors to fast read mode by changing the ACF files
    they are using.

    KTL Keywords Used:

    - `kpfgreen.ACFFILE`
    - `kpfgreen.ACF`
    - `kpfred.ACFFILE`
    - `kpfred.ACF`

    Functions Called:

    - `kpf.spectrograph.QueryReadMode`
    - `kpf.utils.SendEmail`
    '''
    @classmethod
    def pre_condition(cls, args):
        pass

    @classmethod
    def perform(cls, args):
        green_mode, red_mode = QueryReadMode.execute({})
        if green_mode != 'fast':
            msg = f'Setting Green CCD read mode fast'
            log.info(msg)
            # Email to kpf_info
#             try:
#                 SendEmail.execute({'Subject': msg, 'Message': msg})
#             except Exception as email_err:
#                 log.error(f'Sending email failed')
#                 log.error(email_err)
            kpfgreen = ktl.cache('kpfgreen')
            green_fast_file = cfg.get('acf_files', 'green_fast')
            green_ACFFILE = Path(kpfgreen['ACFFILE'].read()).stem
            if green_ACFFILE != green_fast_file:
                kpfgreen['ACF'].write(green_fast_file)
        if red_mode != 'fast':
            msg = f'Setting Red CCD read mode fast'
            log.info(msg)
            # Email to kpf_info
#             try:
#                 SendEmail.execute({'Subject': msg, 'Message': msg})
#             except Exception as email_err:
#                 log.error(f'Sending email failed')
#                 log.error(email_err)
            kpfred = ktl.cache('kpfred')
            red_fast_file = cfg.get('acf_files', 'red_fast')
            red_ACFFILE = Path(kpfred['ACFFILE'].read()).stem
            if red_ACFFILE != red_fast_file:
                kpfred['ACF'].write(red_fast_file)

    @classmethod
    def post_condition(cls, args):
        green_mode, red_mode = QueryReadMode.execute({})
        if green_mode != "fast":
            raise FailedToReachDestination(green_mode, "fast")
        if red_mode != "fast":
            raise FailedToReachDestination(red_mode, "fast")