VerifyCurrentBase

Bases: KPFTranslatorFunction

Check whether the tip tilt system's target pixel (kpffiu.CURRENT_BASE) is consistent with the selected pointing origin (dcs.PONAME)

KTL Keywords Used:

  • dcs1.PONAME
  • kpfguide.CURRENT_BASE
  • kpfguide.SCIENCE_BASE
  • kpfguide.SKY_BASE
Source code in kpf/fiu/VerifyCurrentBase.py
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
class VerifyCurrentBase(KPFTranslatorFunction):
    '''Check whether the tip tilt system's target pixel (kpffiu.CURRENT_BASE)
    is consistent with the selected pointing origin (dcs.PONAME)

    KTL Keywords Used:

    - `dcs1.PONAME`
    - `kpfguide.CURRENT_BASE`
    - `kpfguide.SCIENCE_BASE`
    - `kpfguide.SKY_BASE`
    '''
    @classmethod
    def pre_condition(cls, args, logger, cfg):
        pass

    @classmethod
    def perform(cls, args, logger, cfg):
        ponamekw = ktl.cache('dcs1', 'PONAME')
        poname = ponamekw.read().upper()

        kpfguide = ktl.cache('kpfguide')
        current_base = kpfguide['CURRENT_BASE'].read(binary=True)
        science_base = kpfguide['SCIENCE_BASE'].read(binary=True)
        sky_base = kpfguide['SKY_BASE'].read(binary=True)

        science_match = np.all(np.isclose(current_base, science_base, atol=0.01))
        sky_match = np.all(np.isclose(current_base, sky_base, atol=0.01))
        msg = f"CURRENT_BASE="
        if science_match:
            log.debug(f"CURRENT_BASE is science fiber, PO = {poname}")
            msg += 'SCIENCE_BASE'
        elif sky_match:
            log.debug(f"CURRENT_BASE is sky fiber, PO = {poname}")
            msg += 'SKY_BASE'
        else:
            log.debug(f"CURRENT_BASE is {current_base}, PO = {poname}")
            msg += 'custom'

        poname_match = (science_match and poname == 'KPF')\
                       or (sky_match and poname == 'SKY')
        if poname_match:
            msg += f" which is consistent with PONAME={poname}"
            log.debug(msg)
        else:
            msg += f" which is NOT consistent with PONAME={poname}"
            log.error(msg)
        print(msg)

        return poname_match