class GetGaiaStars(KPFTranslatorFunction):
'''Build a ds9 region file of Gaia catalog stars which ought to be present
in the specified guider image.
Args:
file (str): The file to retrieve stars for.
'''
@classmethod
def pre_condition(cls, args, logger, cfg):
if Vizier is None:
raise FailedPreCondition('Unable to import astroquery.vizier')
file = Path(args.get('file', '/tmp/CRED2.fits')).expanduser().absolute()
if file.exists() is False:
raise FailedPreCondition(f'Fould not find input file: {file}')
@classmethod
def perform(cls, args, logger, cfg):
catalog_id = cfg.get('stellar_catalog', 'catalog_id',
fallback='I/345/gaia2')
search_radius = cfg.getfloat('stellar_catalog', 'search_radius',
fallback=28)
ds9_color = cfg.get('stellar_catalog', 'ds9_color',
fallback='cyan')
ds9_font = cfg.get('stellar_catalog', 'ds9_font',
fallback='helvetica 10 normal roman')
requery_threshold = cfg.getfloat('stellar_catalog', 'requery_threshold',
fallback=5)
region_file = Path('~/.CRED2_auto_regions.reg').expanduser()
cntr_file = Path('~/.CRED2_auto_regions.cntr').expanduser()
file = Path(args.get('file', './junk.fits')).expanduser().absolute()
# hdul = fits.open(file)
header = fits.getheader(file)
w = WCS(header)
# cntr = w.pixel_to_world(hdul[0].data.shape[0]/2, hdul[0].data.shape[1]/2)
cntr = w.pixel_to_world(int(header.get('NAXIS2'))/2, int(header.get('NAXIS1'))/2)
if cntr_file.exists() is False:
with open(cntr_file, 'w') as FO:
FO.write(cntr.to_string('hmsdms', precision=2))
else:
with open(cntr_file, 'r') as FO:
cntr_file_string = FO.readlines()
file_cntr = SkyCoord(cntr_file_string, unit=(u.hourangle, u.deg),
frame='icrs')
sep = file_cntr.separation(cntr)
# If we're in a new position, query for a new catalog of stars and
# write a new region file
if sep[0].to(u.arcsec).value > requery_threshold:
print(f'Querying for catalog: {cntr.to_string("hmsdms", precision=2)}')
gaia = Vizier.query_region(cntr, radius=search_radius*u.arcsec,
catalog=catalog_id)[0]
regions = [f'# Region file format: DS9 version 4.1',
f'global color={ds9_color} dashlist=8 3 width=1 font="{ds9_font}"',
]
for star in gaia:
sc = SkyCoord(star['RA_ICRS'], star['DE_ICRS'],
unit=(u.deg, u.deg), frame='icrs')
coord_string = sc.to_string('hmsdms', sep=':', precision=2).replace(' ', ',')
newline = f"circle({coord_string},0.5\")"# \# text=\{"#\}"
newline += " # text={"
newline += f"{star['RPmag']:.1f}"
newline += "}"
regions.append(newline)
if region_file.exists(): region_file.unlink()
with open(region_file, 'w') as FO:
for line in regions:
FO.write(line+'\n')
@classmethod
def post_condition(cls, args, logger, cfg):
pass
@classmethod
def add_cmdline_args(cls, parser, cfg=None):
parser.add_argument('file', type=str,
help='The CRED2 file to retrieve stars for')
return super().add_cmdline_args(parser, cfg)