60 | class ShutdownTipTilt(KPFTranslatorFunction):
'''Shutdown the tip tilt system by setting the control mode to open loop
and setting the target values in X and Y to 0.
KTL Keywords Used:
- `kpffiu.TTXSRV`
- `kpffiu.TTYSRV`
- `kpffiu.TTXVAX`
- `kpffiu.TTYVAX`
- `kpfguide.TIPTILT_CONTROL`
- `kpfguide.TIPTILT_CALC`
- `kpfguide.TIPTILT_HOME`
'''
@classmethod
def pre_condition(cls, args, logger, cfg):
pass
@classmethod
def perform(cls, args, logger, cfg):
kpfguide = ktl.cache('kpfguide')
kpffiu = ktl.cache('kpffiu')
xopen = kpffiu['TTXSRV'].read() == 'Open'
yopen = kpffiu['TTYSRV'].read() == 'Open'
if xopen and yopen:
# No actions needed
return
elif xopen == False and yopen == False:
# Both axis are in closed loop mode
# Shut down tip tilt activity and park mirror before opening loops
kpfguide['TIPTILT_CONTROL'].write('Inactive')
kpfguide['TIPTILT_CALC'].write('Inactive')
tthome = ktl.cache('kpfguide', 'TIPTILT_HOME')
home = tthome.read(binary=True)
log.debug(f'Sending Tip tilt mirror to home: {home[0]} {home[1]}')
kpffiu['TTXVAX'].write(home[0])
kpffiu['TTYVAX'].write(home[1])
log.debug('Opening tip tilt mirror servo loops')
kpffiu['TTXSRV'].write('open')
kpffiu['TTYSRV'].write('open')
else:
# We're in a mixed state, just open the loops
log.debug('Opening tip tilt mirror servo loops')
kpffiu['TTXSRV'].write('open')
kpffiu['TTYSRV'].write('open')
@classmethod
def post_condition(cls, args, logger, cfg):
timeout = cfg.getfloat('times', 'tip_tilt_move_time', fallback=0.1)
success1 = ktl.waitFor('($kpffiu.TTXSRV == open)', timeout=timeout)
success2 = ktl.waitFor('($kpffiu.TTYSRV == open)', timeout=timeout)
if success1 == False or success2 == False:
raise FailedPostCondition(f'TT[X and/or Y]SRV did not open')
|