StopTipTilt

Bases: KPFTranslatorFunction

Stop the tip tilt control loop. This uses the ALL_LOOPS keyword to stop all functions including DAR (via DAR_ENABLE), tip tilt calculations (via TIPTILT_CALC), tip tilt control (via TIPTILT_CONTROL), offloading to the telescope (via OFFLOAD_DCS and OFFLOAD).

KTL Keywords Used:

  • kpfguide.TIPTILT_CALC
  • kpfguide.TIPTILT_CONTROL
  • kpfguide.OFFLOAD
  • kpfguide.ALL_LOOPS
Source code in kpf/fiu/StopTipTilt.py
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
class StopTipTilt(KPFTranslatorFunction):
    '''Stop the tip tilt control loop.  This uses the ALL_LOOPS keyword to
    stop all functions including DAR (via DAR_ENABLE), tip tilt calculations
    (via TIPTILT_CALC), tip tilt control (via TIPTILT_CONTROL), offloading to
    the telescope (via OFFLOAD_DCS and OFFLOAD).

    KTL Keywords Used:

    - `kpfguide.TIPTILT_CALC`
    - `kpfguide.TIPTILT_CONTROL`
    - `kpfguide.OFFLOAD`
    - `kpfguide.ALL_LOOPS`
    '''
    @classmethod
    def pre_condition(cls, args, logger, cfg):
        pass

    @classmethod
    def perform(cls, args, logger, cfg):
        kpfguide = ktl.cache('kpfguide')
        kpfguide['ALL_LOOPS'].write('Inactive')

    @classmethod
    def post_condition(cls, args, logger, cfg):
        timeout = cfg.getfloat('times', 'tip_tilt_move_time', fallback=0.1)
        TIPTILT_CALC = ktl.cache('kpfguide', 'TIPTILT_CALC')
        success = TIPTILT_CALC.waitFor("== 'Inactive'")
        if success is False:
            raise FailedToReachDestination(TIPTILT_CALC.read(), 'Inactive')
        TIPTILT_CONTROL = ktl.cache('kpfguide', 'TIPTILT_CONTROL')
        success = TIPTILT_CONTROL.waitFor("== 'Inactive'")
        if success is False:
            raise FailedToReachDestination(TIPTILT_CONTROL.read(), 'Inactive')
        OFFLOAD = ktl.cache('kpfguide', 'OFFLOAD')
        success = OFFLOAD.waitFor("== 'Inactive'")
        if success is False:
            raise FailedToReachDestination(OFFLOAD.read(), 'Inactive')