class SetTriggeredDetectors(KPFTranslatorFunction):
'''Selects which cameras will be triggered by setting the
`kpfexpose.TRIG_TARG` keyword value.
ARGS:
=====
:TriggerRed: `bool` Trigger the Red detector? (default=False)
:TriggerGreen: `bool` Trigger the Green detector? (default=False)
:TriggerCaHK: `bool` Trigger the CaH&K detector? (default=False)
:TriggerExpMeter: `bool` Trigger the ExpMeter detector? (default=False)
'''
@classmethod
def pre_condition(cls, args, logger, cfg):
pass
@classmethod
def perform(cls, args, logger, cfg):
kpfconfig = ktl.cache('kpfconfig')
detector_list = []
if args.get('TriggerRed', False) is True:
if kpfconfig['RED_ENABLED'].read(binary=True) == False:
log.warning(f'Red detector is not enabled')
else:
detector_list.append('Red')
if args.get('TriggerGreen', False) is True:
if kpfconfig['GREEN_ENABLED'].read(binary=True) == False:
log.warning(f'Green detector is not enabled')
else:
detector_list.append('Green')
if args.get('TriggerCaHK', False) is True:
if kpfconfig['CA_HK_ENABLED'].read(binary=True) == False:
log.warning(f'Ca HK detector is not enabled')
else:
detector_list.append('Ca_HK')
if args.get('TriggerExpMeter', False) is True:
if kpfconfig['EXPMETER_ENABLED'].read(binary=True) == False:
log.warning(f'ExpMeter detector is not enabled')
else:
detector_list.append('ExpMeter')
if args.get('TriggerGuide', False) is True:
detector_list.append('Guide')
detectors_string = ','.join(detector_list)
log.debug(f"Setting triggered detectors to '{detectors_string}'")
kpfexpose = ktl.cache('kpfexpose')
kpfexpose['TRIG_TARG'].write(detectors_string)
shim_time = cfg.getfloat('times', 'kpfexpose_shim_time', fallback=0.1)
sleep(shim_time)
@classmethod
def post_condition(cls, args, logger, cfg):
kpfconfig = ktl.cache('kpfconfig')
kpfexpose = ktl.cache('kpfexpose')
timeshim = cfg.getfloat('times', 'kpfexpose_shim_time', fallback=0.1)
sleep(timeshim)
detectors = kpfexpose['TRIG_TARG'].read()
detector_list = detectors.split(',')
detector_names = [('Red', 'TriggerRed'),
('Green', 'TriggerGreen'),
('Ca_HK', 'TriggerCaHK'),
('ExpMeter', 'TriggerExpMeter'),
# ('Guide', 'TriggerGuide'),
]
# Don't check on guide because there is no enabled keyword for it
for detector in detector_names:
detector_status = detector[0] in detector_list
enabled = kpfconfig[f'{detector[0].upper()}_ENABLED'].read(binary=True)
detector_target = args.get(detector[1], False) and enabled
if detector_target != detector_status:
raise FailedToReachDestination(detector_status, detector_target)
@classmethod
def add_cmdline_args(cls, parser, cfg=None):
parser.add_argument("--Red", "--red", "-r",
dest="TriggerRed",
default=False, action="store_true",
help="Trigger the Red detector during exposure?")
parser.add_argument("--Green", "--green", "-g",
dest="TriggerGreen",
default=False, action="store_true",
help="Trigger the Green detector during exposure?")
parser.add_argument("--CaHK", "--HK", "--cahk", "--hk",
dest="TriggerCaHK",
default=False, action="store_true",
help="Trigger the CaHK detector during exposure?")
parser.add_argument("--ExpMeter", "--expmeter", "--EM", "--em",
dest="TriggerExpMeter",
default=False, action="store_true",
help="Trigger the ExpMeter detector during exposure?")
parser.add_argument("--Guide", "--Guider", "--guide", "--guider", "--CRED2",
dest="TriggerGuide",
default=False, action="store_true",
help="Trigger the Guider detector during exposure?")
return super().add_cmdline_args(parser, cfg)