74 | class SetADCAngles(KPFTranslatorFunction):
'''Quick and dirty code to manually set ADC angles for a notional NULL
position.
KTL Keywords Used:
- `kpffiu.ADC1VAL`
- `kpffiu.ADC2VAL`
'''
@classmethod
def pre_condition(cls, args, logger, cfg):
pass
@classmethod
def perform(cls, args, logger, cfg):
kpffiu = ktl.cache('kpffiu')
el = args.get('EL')
za = 90 - el
ADC_delta = calculate_ADC_delta(za)
log.info(f"ADC Hack: za={za:.1f}, ADC_delta={ADC_delta:.1f}")
# Constants
common_angle = 60
ADC1_offset = -5
ADC2_offset = 5
log.debug(f"ADC Hack: common_angle={common_angle:.1f}")
log.debug(f"ADC Hack: ADC1_offset={ADC1_offset:.1f}")
log.debug(f"ADC Hack: ADC2_offset={ADC2_offset:.1f}")
# Calculations
ADC1 = common_angle + ADC1_offset + za - ADC_delta
ADC2 = common_angle + ADC2_offset - za - ADC_delta
log.info(f"ADC Hack: Writing ADC1VAL={ADC1:.1f}, ADC2VAL={ADC2:.1f}")
kpffiu['ADC1VAL'].write(ADC1)
kpffiu['ADC2VAL'].write(ADC2)
@classmethod
def post_condition(cls, args, logger, cfg):
pass
@classmethod
def add_cmdline_args(cls, parser, cfg=None):
parser.add_argument('EL', type=float,
help="The telescope elevation to use in the calculation")