Bases: KPFTranslatorFunction
Script which configures the instrument for Acquisition step.
- Sets target parameters
- Sets FIU mode
- Executes Slew Cal
This must have arguments as input, either from a file using the -f
command
line tool, or passed in from the execution engine.
:OB: dict
A fully specified science observing block (OB).
Source code in kpf/scripts/ConfigureForAcquisition.py
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98 | class ConfigureForAcquisition(KPFTranslatorFunction):
'''Script which configures the instrument for Acquisition step.
- Sets target parameters
- Sets FIU mode
- Executes Slew Cal
This must have arguments as input, either from a file using the `-f` command
line tool, or passed in from the execution engine.
ARGS:
=====
:OB: `dict` A fully specified science observing block (OB).
'''
@classmethod
@obey_scriptrun
def pre_condition(cls, OB, logger, cfg):
check_input(OB, 'Template_Name', allowed_values=['kpf_sci'])
check_input(OB, 'Template_Version', version_check=True, value_min='0.5')
# Check Slewcals
kpfconfig = ktl.cache('kpfconfig')
if kpfconfig['SLEWCALREQ'].read(binary=True) is True:
slewcal_argsfile = Path(kpfconfig['SLEWCALFILE'].read())
if slewcal_argsfile.exists() is False:
raise FailedPreCondition(f"Slew cal file {slewcal_argsfile} does not exist")
@classmethod
def perform(cls, OB, logger, cfg):
log.info('-------------------------')
log.info(f"Running {cls.__name__}")
for key in OB:
if key not in ['SEQ_Observations']:
log.debug(f" {key}: {OB[key]}")
else:
log.debug(f" {key}:")
for entry in OB[key]:
log.debug(f" {entry}")
log.info('-------------------------')
kpfconfig = ktl.cache('kpfconfig')
kpf_expmeter = ktl.cache('kpf_expmeter')
# Set Octagon
kpfconfig = ktl.cache('kpfconfig')
calsource = kpfconfig['SIMULCALSOURCE'].read()
octagon = ktl.cache('kpfcal', 'OCTAGON').read()
log.debug(f"Current OCTAGON = {octagon}, desired = {calsource}")
if octagon != calsource:
log.info(f"Set CalSource/Octagon: {calsource}")
SetCalSource.execute({'CalSource': calsource, 'wait': False})
## Execute Slew Cal if Requested
if kpfconfig['SLEWCALREQ'].read(binary=True) is True:
slewcal_argsfile = Path(kpfconfig['SLEWCALFILE'].read())
log.info(f"Beginning Slew Cal")
log.debug(f"Using: {slewcal_argsfile}")
with open(slewcal_argsfile, 'r') as file:
slewcal_OB = yaml.safe_load(file)
slewcal_args = slewcal_OB.get('SEQ_Calibrations')[0]
slewcal_args['Template_Name'] = 'kpf_slewcal'
slewcal_args['Template_Version'] = '0.5'
slewcal_args['TriggerCaHK'] = OB['TriggerCaHK']
slewcal_args['TriggerGreen'] = OB['TriggerGreen']
slewcal_args['TriggerRed'] = OB['TriggerRed']
ExecuteSlewCal.execute(slewcal_args)
log.info('Slew cal complete. Resetting SLEWCALREQ')
kpfconfig['SLEWCALREQ'].write('No')
# Set FIU Mode
log.info('Setting FIU mode to Observing')
ConfigureFIU.execute({'mode': 'Observing', 'wait': False})
# Set Target Parameters from OB
SetTargetInfo.execute(OB)
@classmethod
def post_condition(cls, OB, logger, cfg):