IR Atmospheric
Absorption Plot
SPEC Filters |
Filter |
Wheel &
Position |
Central
Wavelength (nm) |
Bandwidth
(nm) |
Cut-On
Wavelength (nm) |
Cut-Off
Wavelength (nm) |
Transmission
Average/Peak (%) |
Datafile |
Zbb |
SFW Pos #1 |
1089.5 |
218.8 |
980.1 |
1198.9 |
83.8 / 93.9 |
txt |
Jbb |
SFW Pos #2 |
1309.7 |
260.1 |
1179.7 |
1439.8 |
78.9 / 86.2 |
txt |
Hbb |
SFW Pos #3 |
1637.9 |
329.5 |
1473.1 |
1802.6 |
92.6 / 96.3 |
txt |
Kbb |
SFW Pos #4 |
2172.8 |
415.7 |
1964.9 |
2380.7 |
85.5 / 92.3 |
txt |
Narrow Band |
Zn2 |
SFW Pos #5 |
1044.5 |
51.3 |
1018.9 |
1070.1 |
69.8 / 76.3 |
txt |
Zn3 |
SFW Pos #6 |
1086.7 |
52.6 |
1060.4 |
1113.0 |
71.6 / 82.9 |
txt |
Zn4 |
SFW Pos #7 |
1130.5 |
54.6 |
1103.2 |
1157.8 |
77.6 / 84.8 |
txt |
Zn5 |
SFW Pos #8 |
1176.2 |
56.3 |
1148.0 |
1204.3 |
72.8 / 79.7 |
txt |
Jn1 |
SFW Pos #9 |
1202.8 |
58.4 |
1173.6 |
1232.0 |
77.8 / 82.9 |
txt |
Jn2 |
SFW Pos #10 |
1258.3 |
60.8 |
1227.9 |
1288.7 |
78.0 / 86.7 |
txt |
Jn3 |
SFW Pos #11 |
1306.9 |
64.5 |
1274.7 |
1339.2 |
84.2 / 91.3 |
txt |
Jn4 |
SFW Pos #12 |
1356.3 |
65.8 |
1323.4 |
1389.2 |
82.3 / 91.1 |
txt |
Hn1 |
SFW Pos #13 |
1503.3 |
74.7 |
1466.0 |
1540.7 |
80.9 / 84.9 |
txt |
Hn2 |
SFW Pos #14 |
1570.8 |
77.6 |
1532.0 |
1609.5 |
75.2 / 84.3 |
txt |
Hn3 |
SFW Pos #15 |
1634.8 |
81.4 |
1594.1 |
1675.5 |
79.5 / 84.3 |
txt |
Hn4 |
SFW Pos #16 |
1694.1 |
84.9 |
1651.6 |
1736.6 |
83.3 / 90.7 |
txt |
Hn5 |
SFW Pos #17 |
1764.4 |
86.1 |
1721.4 |
1807.5 |
74.8 / 86.5 |
txt |
Kn1 |
SFW Pos #18 |
2004.8 |
100.1 |
1954.8 |
2054.9 |
85.1 / 91.7 |
txt |
Kn2 |
SFW Pos #19 |
2088.4 |
104.5 |
2036.2 |
2140.7 |
83.4 / 94.0 |
txt |
Kn3 |
SFW Pos #20 |
2175.4 |
108.0 |
2121.3 |
2229.4 |
83.8 / 91.4 |
txt |
Kn4 |
SFW Pos #21 |
2263.8 |
112.6 |
2207.5 |
2320.1 |
75.0 / 84.7 |
txt |
Kn5 |
SFW Pos #22 |
2349.9 |
116.5 |
2291.7 |
2408.2 |
79.5 / 90.7 |
txt |
IMAG Filters |
Filter |
Wheel &
Position |
Central
Wavelength (nm) |
Bandwidth
(nm) |
Cut-On
Wavelength (nm) |
Cut-Off
Wavelength (nm) |
Transmission
Average/Peak (%) |
Datafile |
Zbb |
IF2 Pos #1 |
1091.5 |
220.3 |
981.4 |
1201.6 |
82.1 / 93.0 |
txt |
Jbb |
IF2 Pos #2 |
1309.4 |
259.8 |
1179.5 |
1439.4 |
79.2 / 86.6 |
txt |
Hbb |
IF2 Pos #3 |
1638.3 |
329.2 |
1473.7 |
1802.9 |
92.6 / 96.3 |
txt |
Kbb |
IF2 Pos #4 |
2171.7 |
415.6 |
1963.9 |
2379.5 |
86.9 / 93.9 |
txt |
Narrow Band |
Zn3 |
IF1 Pos #1 |
1086.8 |
52.5 |
1060.6 |
1113.1 |
71.5 / 82.9 |
txt |
Jn1 |
IF1 Pos #2 |
1202.9 |
58.5 |
1173.7 |
1232.2 |
77.7 / 82.5 |
txt |
Jn2 |
IF1 Pos #3 |
1258.1 |
60.8 |
1227.7 |
1288.5 |
78.2 / 86.5 |
txt |
Jn3 |
IF1 Pos #4 |
1306.0 |
64.3 |
1273.8 |
1338.1 |
84.6 / 92.1 |
txt |
Hn1 |
IF1 Pos #5 |
1503.7 |
74.7 |
1466.4 |
1541.1 |
80.9 / 85.2 |
txt |
Hn2 |
IF1 Pos #6 |
1570.0 |
77.5 |
1531.3 |
1608.8 |
76.6 / 85.5 |
txt |
Hn3 |
IF1 Pos #7 |
1635.1 |
81.4 |
1594.4 |
1675.8 |
79.5 / 84.3 |
txt |
Hn4 |
IF1 Pos #8 |
1695.1 |
84.9 |
1652.6 |
1737.5 |
82.7 / 91.6 |
txt |
Hn5 |
IF1 Pos #9 |
1764.2 |
86.1 |
1721.1 |
1807.2 |
75.0 / 87.0 |
txt |
Kn1 |
IF2 Pos #5 |
2004.4 |
100.2 |
1954.3 |
2054.5 |
84.7 / 91.1 |
txt |
Kn2 |
IF2 Pos #6 |
2090.5 |
104.7 |
2038.1 |
2142.9 |
83.2 / 93.7 |
txt |
Kn3 |
IF2 Pos #7 |
2175.6 |
108.1 |
2121.6 |
2229.7 |
84.1 / 91.6 |
txt |
Kn4 |
IF2 Pos #8 |
2264.8 |
112.4 |
2208.6 |
2321.0 |
75.1 / 84.8 |
txt |
Kn5 |
IF2 Pos #9 |
2349.8 |
116.4 |
2291.6 |
2408.0 |
79.4 / 90.8 |
txt |