Filter Reports
The table below shows the filters installed in OSIRIS. The table is split up into two sections,
one for the Spectrometer portion of OSIRIS (SPEC), and one for the Imager portion (IMAG). The
Central Wavelength, Bandwidth, Cut-On/Cut-Off Wavelengths, and Transmission data listed in this
table are based on the 50% transmission points. All data are for filters
at
operational temperature (77K).
IR Atmospheric
Absorption Plot
Original Filter Complement
SPEC Filters |
Filter |
SFW Pos |
Central
Wavelength (nm) |
Bandwidth
(nm) |
Cut-On
Wavelength (nm) |
Cut-Off
Wavelength (nm) |
Transmission
Average/Peak (%) |
Datafile |
Kcb |
0 |
2172.8 |
415.7 |
1964.9 |
2380.7 |
85.5 / 92.3 |
txt |
Zbb |
1 |
1089.5 |
218.8 |
980.1 |
1198.9 |
83.8 / 93.9 |
txt |
Jbb |
2 |
1309.7 |
260.1 |
1179.7 |
1439.8 |
78.9 / 86.2 |
txt |
Hbb |
3 |
1637.9 |
329.5 |
1473.1 |
1802.6 |
92.6 / 96.3 |
txt |
Kbb |
4 |
2172.8 |
415.7 |
1964.9 |
2380.7 |
85.5 / 92.3 |
txt |
Narrow Band |
Jn4 |
5 |
1356.3 |
65.8 |
1323.4 |
1389.2 |
82.3 / 91.1 |
txt |
Kc3 |
6 |
2175.4 |
108.0 |
2121.3 |
2229.4 |
83.8 / 91.4 |
txt |
Zn4 |
7 |
1130.5 |
54.6 |
1103.2 |
1157.8 |
77.6 / 84.8 |
txt |
Kn1 |
8 |
2004.8 |
100.1 |
1954.8 |
2054.9 |
85.1 / 91.7 |
txt |
Jn1 |
9 |
1202.8 |
58.4 |
1173.6 |
1232.0 |
77.8 / 82.9 |
txt |
Jn2 |
10 |
1258.3 |
60.8 |
1227.9 |
1288.7 |
78.0 / 86.7 |
txt |
Jn3 |
11 |
1306.9 |
64.5 |
1274.7 |
1339.2 |
84.2 / 91.3 |
txt |
Kc4 |
12 |
2263.8 |
112.6 |
2207.5 |
2320.1 |
75.0 / 84.7 |
txt |
Hn1 |
13 |
1503.3 |
74.7 |
1466.0 |
1540.7 |
80.9 / 84.9 |
txt |
Hn2 |
14 |
1570.8 |
77.6 |
1532.0 |
1609.5 |
75.2 / 84.3 |
txt |
Hn3 |
15 |
1634.8 |
81.4 |
1594.1 |
1675.5 |
79.5 / 84.3 |
txt |
Hn4 |
16 |
1694.1 |
84.9 |
1651.6 |
1736.6 |
83.3 / 90.7 |
txt |
Hn5 |
17 |
1764.4 |
86.1 |
1721.4 |
1807.5 |
74.8 / 86.5 |
txt |
Kc5 |
18 |
2349.9 |
116.5 |
2291.7 |
2408.2 |
79.5 / 90.7 |
txt |
Kn2 |
19 |
2088.4 |
104.5 |
2036.2 |
2140.7 |
83.4 / 94.0 |
txt |
Kn3 |
20 |
2175.4 |
108.0 |
2121.3 |
2229.4 |
83.8 / 91.4 |
txt |
Kn4 |
21 |
2263.8 |
112.6 |
2207.5 |
2320.1 |
75.0 / 84.7 |
txt |
Kn5 |
22 |
2349.9 |
116.5 |
2291.7 |
2408.2 |
79.5 / 90.7 |
txt |
Drk |
23 |
|
|
|
|
|
|
Original Filter Complement
IMAG Filters |
Name |
Type |
Wheel |
Position |
Central Wavelength (nm) |
Bandwidth (nm) |
Cut-On Wavelength (nm) |
Cut-Off Wavelength (nm) |
Transmission Average/Peak (%) |
Datafile |
Jn1 |
Filter |
1 |
0 |
1202.9 |
58.5 |
1173.7 |
1232.2 |
77.7 / 82.5 |
txt
|
LAnn |
Pupil |
1 |
1 |
|
|
|
|
|
|
Jn2
|
Filter |
1 |
2 |
1258.1 |
60.8 |
1227.7 |
1288.5 |
78.2 / 86.5 |
txt
|
Jn3
|
Filter |
1 |
3 |
1306.0 |
64.3 |
1273.8 |
1338.1 |
84.6 / 92.1 |
txt
|
SAnn |
Pupil |
1 |
4 |
|
|
|
|
|
|
Hn1
|
Filter |
1 |
5 |
1503.7 |
74.7 |
1466.4 |
1541.1 |
80.9 / 85.2 |
txt
|
Hn2
|
Filter |
1 |
6 |
1570.0 |
77.5 |
1531.3 |
1608.8 |
76.6 / 85.5 |
txt
|
SHex |
Pupil |
1 |
7 |
|
|
|
|
|
|
Hn3
|
Filter |
1 |
8 |
1635.1 |
81.4 |
1594.4 |
1675.8 |
79.5 / 84.3 |
txt
|
Hn4
|
Filter |
1 |
9 |
1695.1 |
84.9 |
1652.6 |
1737.5 |
82.7 / 91.6 |
txt
|
LHex |
Pupil |
1 |
10 |
|
|
|
|
|
|
HAM |
Mask |
1 |
11 |
|
|
|
|
|
|
FeII |
Filter |
1 |
12 |
1647.5 |
26.1 |
1634.4 |
1660.5 |
TBC / 91.7 |
|
Hcont |
Filter |
1 |
13 |
1583.2 |
25.2 |
1570.6 |
1595.8 |
TBC / 90.0 |
|
Open |
Pupil |
1 |
14 |
|
|
|
|
|
|
Zn3
|
Filter |
1 |
15 |
1086.8 |
52.5 |
1060.6 |
1113.1 |
71.5 / 82.9 |
txt
|
Y |
Filter |
2 |
0 |
1025.1 |
96.0 |
977.1 |
1073.1 |
TBC / 90.1 |
|
J |
Filter |
2 |
1 |
1242.9 |
149.9 |
1168.0 |
1317.9 |
TBC / 89.4 |
|
Open |
Pupil |
2 |
2 |
|
|
|
|
|
|
Hbb
|
Filter |
2 |
3 |
1638.3 |
329.2 |
1473.7 |
1802.9 |
92.6 / 96.3 |
txt
|
Kp |
Filter |
2 |
4 |
2114.5 |
307.0 |
1960.9 |
2268.0 |
TBC / 86.7 |
|
Hn5
|
Filter |
2 |
5 |
1764.2 |
86.1 |
1721.1 |
1807.2 |
75.0 / 87.0 |
txt
|
Kn1
|
Filter |
2 |
6 |
2004.4 |
100.2 |
1954.3 |
2054.5 |
84.7 / 91.1 |
txt
|
Kn2
|
Filter |
2 |
7 |
2090.5 |
104.7 |
2038.1 |
2142.9 |
83.2 / 93.7 |
txt
|
Kn3
|
Filter |
2 |
8 |
2175.6 |
108.1 |
2121.6 |
2229.7 |
84.1 / 91.6 |
txt
|
Kn4
|
Filter |
2 |
9 |
2264.8 |
112.4 |
2208.6 |
2321.0 |
75.1 / 84.8 |
txt
|
Kn5
|
Filter |
2 |
10 |
2349.8 |
116.4 |
2291.6 |
2408.0 |
79.4 / 90.8 |
txt
|
BrGamma |
Filter |
2 |
11 |
2169.3 |
29.5 |
2154.5 |
2184.1 |
TBC / 83.0 |
|
Kcont |
Filter |
2 |
12 |
2270.0 |
21.7 |
2259.2 |
2280.8 |
TBC / 68.5 |
|
HeI_B |
Filter |
2 |
13 |
2060.5 |
28.3 |
2046.4 |
2074.7 |
TBC / 88.6 |
|
PV |
Lens |
2 |
14 |
|
|
|
|
|
|
Zbb
|
Filter |
2 |
15 |
1091.5 |
220.3 |
981.4 |
1201.6 |
82.1 / 93.0 |
txt
|