StagePMACMotorStageNegative LimitPositive LimitInternal UnitsStageNegative LimitPositive LimitUser Units
Afmp1mtr6Afm-53600016000encoder_countsAfm-134.0004.000millimeters
Afsp1mtr7Afs-139000140500encoder_countsAfs-139.000140.500millimeters
Fsm1xp3mtr5Fsm1x-8000080000encoder_countsFsm1x-22.45922.459degrees
Fsm1yp3mtr6Fsm1y-3500070000encoder_countsFsm1y-9.82619.652degrees
Fsm2xp3mtr7Fsm2x-2000083000encoder_countsFsm2x-5.61423.302degrees
Fsm2yp3mtr8Fsm2y-6000050000encoder_countsFsm2y-16.84414.037degrees
Fssp3mtr3Fss-659327355894encoder_countsFss-32.96617.794millimeters
Lbsxp4mtr1Lbsx-6000028500encoder_countsLbsx-6000028500encoder_counts
Lbsyp4mtr2Lbsy-27500065700encoder_countsLbsy-13.7503.285millimeters
Rotp0mtr1Rot00encoder_countsRot00degrees
Sodp1mtr5Sod-5790002000encoder_countsSod-144.7500.500millimeters
Sfpxp0mtr2Sfpx-3924044760encoder_countsSfpx-3924044760encoder_counts
Sfpyp0mtr3Sfpy-3725046750encoder_countsSfpy-37.25046.750millimeters
Sfpzp0mtr4Sfpz-2598750encoder_countsSfpz-.02598.750millimeters
Sfdp4mtr3Sfd00encoder_countsSfd00millimeters
Sndp0mtr6Snd00encoder_countsSnd00degrees
Sfwp1mtr4Sfw-40640encoder_countsSfw-10.282164.524degrees
Ttdp4mtr7Ttd00encoder_countsTtd00millimeters
Ttfp4mtr8Ttf00encoder_countsTtf00encoder_counts
Tssxp4mtr4Tssx-570000640000encoder_countsTssx-570000640000encoder_counts
Tssyp4mtr5Tssy-160000870000encoder_countsTssy-160000870000encoder_counts
Tsszp4mtr6Tssz-300000175000encoder_countsTssz-300000175000encoder_counts
Wcsp3mtr4Wcs-524346483encoder_countsWcs-5.24346.483millimeters
Fcsp1mtr1Fcs-8700279000encoder_countsFcs-8.700279.000millimeters
Wlsrp0mtr5Wlsr-776100170000encoder_countsWlsr-776100170000encoder_counts
Wlsxp3mtr1Wlsx-3627613543encoder_countsWlsx-1.8130.677millimeters
Wlsyp3mtr2Wlsy-4913553416encoder_countsWlsy-2.4562.670millimeters
Wndp0mtr5Wnd-776100170000encoder_countsWnd-38.8058.500millimeters
Wpsp1mtr2Wps-4972388712encoder_countsWps-2.4864.435millimeters

K2 AO Bench Stages

StagePMACMotorStageNegative LimitPositive LimitInternal UnitsStageNegative LimitPositive LimitUser Units
Afmp4mtr2Afm-1000580000encoder_countsAfm-0.250145.000millimeters
Afsp4mtr3Afs-140500140500encoder_countsAfs-140.500140.500millimeters
Dfbp0mtr7Dfb-7200178400encoder_countsDfb-1.80044.600millimeters
Fsm1xp3mtr5Fsm1x-13100051000encoder_countsFsm1x-36.77814.318degrees
Fsm1yp3mtr6Fsm1y-9000052000encoder_countsFsm1y-25.26714.598degrees
Fsm2xp3mtr7Fsm2x-75000105000encoder_countsFsm2x-21.05629.478degrees
Fsm2yp3mtr8Fsm2y-6200058000encoder_countsFsm2y-17.40616.283degrees
Fssp3mtr3Fss-569496461179encoder_countsFss-28.47423.058millimeters
Ismp0mtr5Ism00encoder_countsIsm00millimeters
Lbsxp1mtr7Lbsx-3000100000encoder_countsLbsx-0.1505.000millimeters
Lbsyp1mtr8Lbsy-3000250000encoder_countsLbsy-0.15012.500millimeters
Rotp0mtr1Rot00encoder_countsRot00degrees
Sodp4mtr1Sod-17000570000encoder_countsSod-4.250142.500millimeters
Sfpxp0mtr2Sfpx-3290032900encoder_countsSfpx-3290032900encoder_counts
Sfpyp0mtr3Sfpy-4770032900encoder_countsSfpy-47.70032.900millimeters
Sfpzp0mtr4Sfpz-10098750encoder_countsSfpz-0.10098.750millimeters
Sfdp0mtr8Sfd-570007000encoder_countsSfd-2.8500.350millimeters
Sndp4mtr7Snd00encoder_countsSnd00degrees
Ofmp4mtr8Ofm-121000124000encoder_countsOfm-30.25031.000millimeters
Sfwp1mtr3Sfw-401400encoder_countsSfw-10.282359.897degrees
Tssxp4mtr4Tssx-3840040200encoder_countsTssx-3840040200encoder_counts
Tssyp4mtr5Tssy-3640073500encoder_countsTssy-3640073500encoder_counts
Tsszp4mtr6Tssz-4020047200encoder_countsTssz-4020047200encoder_counts
Wcsp3mtr4Wcs-2400052800encoder_countsWcs-24.00052.800millimeters
Wlsrp0mtr5Wlsr00encoder_countsWlsr00encoder_counts
Wlsxp3mtr1Wlsx-191826984encoder_countsWlsx-.0951.349millimeters
Wlsyp3mtr2Wlsy-4854754515encoder_countsWlsy-2.4272.725millimeters
Wndp0mtr6Wnd-900000100000encoder_countsWnd-45.0005.000millimeters
Wpsp1mtr2Wps-6351992500encoder_countsWps-3.1754.625millimeters
Last modified: 05/24/2025 15:37
Send questions or comments to:AO Support

The information on this page is the property of the W. M. Keck Observatory. The contents of this page or any part thereof shall not be copied or otherwise reproduced or transferred to other documents or used or disclosed to others for any purpose other than observing support at the W. M. Keck Observatory and the subsequent analysis and publication of scientific data obtained from observations conducted at the W. M. Keck Observatory. All rights reserved. © W. M. Keck Observatory.