The table below lists all of the ESI keywords, together with a brief description, the format of the keyword, and either the Galil controller which handles that keyword, of "CCD" if the CCD controller handles it.
Note that these keywords are in ALPHABETICAL order, not in the order in which they appear in the output from a "show -s esi keywords" command. Also note that only a subset of these keywords is recorded in the FITS image headers.
| Keyword | Description | Format | Controller |
|---|---|---|---|
| ABFREQ | antiblooming-frequency | integer | CCD |
| ABORTEX | abort-exposure | logical | CCD |
| ADDFRAME | add-frame-numbers | logical | CCD |
| AIRPRESS | air-pressure-status | logical | 1 |
| AIRPWPSI | compressed-air-power-psi | real number | 0 |
| AIRPWRAW | compressed-air-power-raw | real number | 0 |
| AMPLIST | readout-amplifiers | array of integers[4] | CCD |
| ANTIBLM | antiblooming | logical | CCD |
| APMSKCAL | aperture-mask-calibration | logical | 0 |
| APMSKDMP | aperture-mask-dump | logical | 0 |
| APMSKENC | aperture-mask-motor-encoder-position | integer | 0 |
| APMSKERR | aperture-mask-error-number | integer | 0 |
| APMSKLCK | aperture-mask-lock | ascii string | 0 |
| APMSKMOD | aperture-mask-control-mode | enumerated integer | 0 |
| APMSKMSG | aperture-mask-message | ascii string | 0 |
| APMSKNAM | middle-wheel | ascii string | 0 |
| APMSKORD | aperture-mask-ordinal-position | integer | 0 |
| APMSKRAW | aperture-mask-raw-position | integer | 0 |
| APMSKREN | aperture-mask-stage-encoder-signal-quality | real number | 0 |
| APMSKSPD | aperture-mask-speed | integer | 0 |
| APMSKSTA | aperture-mask-status | enumerated integer | 0 |
| APMSKTOR | aperture-mask-torque | real number | 0 |
| APMSKTRG | aperture-mask-raw-position-target | integer | 0 |
| APMSKTSP | aperture-mask-speed-target | integer | 0 |
| APMSKVAL | aperture-mask-value | real number | 0 |
| APMSKVEL | aperture-mask-velocity | real number | 0 |
| APMSKVRB | aperture-mask-verbose-messages | logical | 0 |
| AUTOERAS | automatic-erase | logical | CCD |
| AUTOREAD | automatic-readout | logical | CCD |
| AUTOSHUT | automatic-shutter | logical | CCD |
| BINNING | binning | array of integers[2] | CCD |
| CCDBCAST | ccd-music-broadcasts | array of integers[10] | CCD |
| CCDGAIN | ccd-gain | logical | CCD |
| CCDSPEED | ccd-readout-speed | enumerated integer | CCD |
| COLL1CAL | collimator-actuator-1-calibration | logical | 0 |
| COLL1DMP | collimator-actuator-1-dump | logical | 0 |
| COLL1ENC | collimator-actuator-1-motor-encoder-position | integer | 0 |
| COLL1ERR | collimator-actuator-1-error-number | integer | 0 |
| COLL1FIP | collimator-actuator-1-fiducial-light-sensor | logical | 0 |
| COLL1FOP | collimator-actuator-1-fiducial-light-source | logical | 0 |
| COLL1LCK | collimator-actuator-1-lock | ascii string | 0 |
| COLL1LIM | collimator-actuator-1-limits | enumerated integer | 0 |
| COLL1MOD | collimator-actuator-1-control-mode | enumerated integer | 0 |
| COLL1MSG | collimator-actuator-1-message | ascii string | 0 |
| COLL1NAM | collimator-actuator-1-named-position | ascii string | 0 |
| COLL1ORD | collimator-actuator-1-ordinal-position | integer | 0 |
| COLL1RAW | collimator-actuator-1-raw-position | integer | 0 |
| COLL1REN | collimator-actuator-1-stage-encoder-signal-quality | real number | 0 |
| COLL1SPD | collimator-actuator-1-speed | integer | 0 |
| COLL1STA | collimator-actuator-1-status | enumerated integer | 0 |
| COLL1TOR | collimator-actuator-1-torque | real number | 0 |
| COLL1TRG | collimator-actuator-1-raw-position-target | integer | 0 |
| COLL1TSP | collimator-actuator-1-speed-target | integer | 0 |
| COLL1VAL | collimator-actuator-1-value | real number | 0 |
| COLL1VEL | collimator-actuator-1-velocity | real number | 0 |
| COLL1VRB | collimator-actuator-1-verbose-messages | logical | 0 |
| COLL2CAL | collimator-actuator-2-calibration | logical | 0 |
| COLL2DMP | collimator-actuator-2-dump | logical | 0 |
| COLL2ENC | collimator-actuator-2-motor-encoder-position | integer | 0 |
| COLL2ERR | collimator-actuator-2-error-number | integer | 0 |
| COLL2FIP | collimator-actuator-2-fiducial-light-sensor | logical | 0 |
| COLL2FOP | collimator-actuator-2-fiducial-light-source | logical | 0 |
| COLL2LCK | collimator-actuator-2-lock | ascii string | 0 |
| COLL2LIM | collimator-actuator-2-limits | enumerated integer | 0 |
| COLL2MOD | collimator-actuator-2-control-mode | enumerated integer | 0 |
| COLL2MSG | collimator-actuator-2-message | ascii string | 0 |
| COLL2NAM | collimator-actuator-2-named-position | ascii string | 0 |
| COLL2ORD | collimator-actuator-2-ordinal-position | integer | 0 |
| COLL2RAW | collimator-actuator-2-raw-position | integer | 0 |
| COLL2REN | collimator-actuator-2-stage-encoder-signal-quality | real number | 0 |
| COLL2SPD | collimator-actuator-2-speed | integer | 0 |
| COLL2STA | collimator-actuator-2-status | enumerated integer | 0 |
| COLL2TOR | collimator-actuator-2-torque | real number | 0 |
| COLL2TRG | collimator-actuator-2-raw-position-target | integer | 0 |
| COLL2TSP | collimator-actuator-2-speed-target | integer | 0 |
| COLL2VAL | collimator-actuator-2-value | real number | 0 |
| COLL2VEL | collimator-actuator-2-velocity | real number | 0 |
| COLL2VRB | collimator-actuator-2-verbose-messages | logical | 0 |
| COLL3CAL | collimator-actuator-3-calibration | logical | 0 |
| COLL3DMP | collimator-actuator-3-dump | logical | 0 |
| COLL3ENC | collimator-actuator-3-motor-encoder-position | integer | 0 |
| COLL3ERR | collimator-actuator-3-error-number | integer | 0 |
| COLL3FIP | collimator-actuator-3-fiducial-light-sensor | logical | 0 |
| COLL3FOP | collimator-actuator-3-fiducial-light-source | logical | 0 |
| COLL3LCK | collimator-actuator-3-lock | ascii string | 0 |
| COLL3LIM | collimator-actuator-3-limits | enumerated integer | 0 |
| COLL3MOD | collimator-actuator-3-control-mode | enumerated integer | 0 |
| COLL3MSG | collimator-actuator-3-message | ascii string | 0 |
| COLL3NAM | collimator-actuator-3-named-position | ascii string | 0 |
| COLL3ORD | collimator-actuator-3-ordinal-position | integer | 0 |
| COLL3RAW | collimator-actuator-3-raw-position | integer | 0 |
| COLL3REN | collimator-actuator-3-stage-encoder-signal-quality | real number | 0 |
| COLL3SPD | collimator-actuator-3-speed | integer | 0 |
| COLL3STA | collimator-actuator-3-status | enumerated integer | 0 |
| COLL3TOR | collimator-actuator-3-torque | real number | 0 |
| COLL3TRG | collimator-actuator-3-raw-position-target | integer | 0 |
| COLL3TSP | collimator-actuator-3-speed-target | integer | 0 |
| COLL3VAL | collimator-actuator-3-value | real number | 0 |
| COLL3VEL | collimator-actuator-3-velocity | real number | 0 |
| COLL3VRB | collimator-actuator-3-verbose-messages | logical | 0 |
| COLLDMP | collimator-dump | logical | 0 |
| COLLERR | collimator-error-number | integer | 0 |
| COLLFLX1 | collimator-flexure-compensation-offset-actuator-1 | integer | 0 |
| COLLFLX2 | collimator-flexure-compensation-offset-actuator-2 | integer | 0 |
| COLLFLX3 | collimator-flexure-compensation-offset-actuator-3 | integer | 0 |
| COLLFOC | collimator-focus | real number | 0 |
| COLLFOCR | focus | integer | 0 |
| COLLFOCT | collimator-focus-target | integer | 0 |
| COLLMODE | collimator-control-mode | enumerated integer | 0 |
| COLLMSG | collimator-message | ascii string | 0 |
| COLLOFF1 | collimator-offset-error-actuator-1 | integer | 0 |
| COLLOFF2 | collimator-offset-error-actuator-2 | integer | 0 |
| COLLOFF3 | collimator-offset-error-actuator-3 | integer | 0 |
| COLLSTAT | collimator-control-status | enumerated integer | 0 |
| COLLUSR1 | collimator-user-offset-actuator-1 | integer | 0 |
| COLLUSR2 | collimator-user-offset-actuator-2 | integer | 0 |
| COLLUSR3 | collimator-user-offset-actuator-3 | integer | 0 |
| COLLVRB | collimator-verbose-messages | enumerated integer | 0 |
| COOLFLOW | external-coolant-flow | logical | 0 |
| COOLPRES | external-coolant-pressure | logical | 0 |
| CSHUTTER | camera-shutter | logical | CCD |
| CTRL0BEK | controller-0-bekins | enumerated integer | 0 |
| CTRL0CLK | controller-0-clock | integer | 0 |
| CTRL0DMP | controller-0-dump | logical | 0 |
| CTRL0MOD | controller-0-control-mode | enumerated integer | 0 |
| CTRL0MON | controller-0-monitor | enumerated integer | 0 |
| CTRL0UHL | controller-0-uhaul | enumerated integer | 0 |
| CTRL1BEK | controller-1-bekins | enumerated integer | 1 |
| CTRL1CLK | controller-1-clock | integer | 1 |
| CTRL1DMP | controller-1-dump | logical | 1 |
| CTRL1MOD | controller-1-control-mode | enumerated integer | 1 |
| CTRL1MON | controller-1-monitor | enumerated integer | 1 |
| CTRL1UHL | controller-1-uhaul | enumerated integer | 1 |
| CTRLFAN0 | controller-0-electronics-fans | logical | 0 |
| CTRLFAN1 | controller-1-electronics-fans | logical | 1 |
| DATALINE | data-lines | integer | CCD |
| DATAPIX | data-pixels | integer | CCD |
| DETECTOR | detector | ascii string | CCD |
| DEWARID | dewar-id | integer | CCD |
| DFORM | disk-file-format | ascii string | CCD |
| DISP0CFG | dispatcher-0-config-time-stamp | ascii string | 0 |
| DISP0HOM | dispatcher-0-host-machine | ascii string | 0 |
| DISP0LOG | dispatcher-0-log-filename | ascii string | 0 |
| DISP0MOD | dispatcher-0-control-mode | enumerated integer | 0 |
| DISP0PID | dispatcher-0-process-id | integer | 0 |
| DISP1CFG | dispatcher-1-config-time-stamp | ascii string | 1 |
| DISP1HOM | dispatcher-1-host-machine | ascii string | 1 |
| DISP1LOG | dispatcher-1-log-filename | ascii string | 1 |
| DISP1MOD | dispatcher-1-control-mode | enumerated integer | 1 |
| DISP1PID | dispatcher-1-process-id | integer | 1 |
| DWFILCAL | dewar-filter-calibration | logical | 0 |
| DWFILDMP | xxx-xxx-dump | logical | 0 |
| DWFILENC | dewar-filter-motor-encoder-position | integer | 0 |
| DWFILERR | dewar-filter-error-number | integer | 0 |
| DWFILLCK | dewar-filter-lock | ascii string | 0 |
| DWFILMOD | dewar-filter-control-mode | enumerated integer | 0 |
| DWFILMSG | dewar-filter-message | ascii string | 0 |
| DWFILNAM | lower-wheel | ascii string | 0 |
| DWFILORD | dewar-filter-ordinal-position | integer | 0 |
| DWFILRAW | dewar-filter-raw-position | integer | 0 |
| DWFILREN | dewar-filter-stage-encoder-signal-quality | real number | 0 |
| DWFILSPD | dewar-filter-speed | integer | 0 |
| DWFILSTA | dewar-filter-status | enumerated integer | 0 |
| DWFILTOR | dewar-filter-torque | real number | 0 |
| DWFILTRG | dewar-filter-raw-position-target | integer | 0 |
| DWFILTSP | dewar-filter-speed-target | integer | 0 |
| DWFILVAL | dewar-filter-value | real number | 0 |
| DWFILVEL | dewar-filter-velocity | real number | 0 |
| DWFILVRB | dewar-filter-verbose-messages | logical | 0 |
| DWINDOW | desired-window | array of integers[5] | CCD |
| DWRMANF | dewar-manual-fill | logical | CCD |
| DWRN2LV | ccd-dewar-nitrogen-level | real number | CCD |
| DWRN2LVM | ccd-dewar-nitrogen-level-map | array of real numbers[5] | CCD |
| DWRN2LVR | ccd-dewar-nitrogen-level-raw | integer | CCD |
| ELAPTIME | elapsed-time | integer | CCD |
| ERASECNT | erase-count | integer | CCD |
| ERASEIP | erase-in-progress | logical | CCD |
| ERASLINE | erase-line | logical | CCD |
| EXPOSE | start-exposure | logical | CCD |
| EXPOSIP | exposure-in-progress | logical | CCD |
| FCOMMENT | frame_comments | ascii string | CCD |
| FRAMENO | frame-number | integer | CCD |
| HATCHDMP | hatch-dump | logical | 1 |
| HATCHERR | hatch-error-number | integer | 1 |
| HATCHLCK | hatch-lock | ascii string | 1 |
| HATCHMSG | hatch-message | ascii string | 1 |
| HATCHPOS | hatch-position | enumerated integer | 1 |
| HATCHSTA | hatch-status | enumerated integer | 1 |
| HATCHTRG | hatch-target | enumerated integer | 1 |
| HATCHVRB | hatch-verbose-messages | logical | 1 |
| ICOMMENT | instrument_comments | ascii string | CCD |
| IMFLTBRK | image-flat-shuttle-brake | logical | 1 |
| IMFLTCAL | image-flat-shuttle-calibration | logical | 1 |
| IMFLTDMP | image-flat-shuttle-dump | logical | 1 |
| IMFLTERR | image-flat-shuttle-error-number | integer | 1 |
| IMFLTLCK | image-flat-shuttle-lock | ascii string | 1 |
| IMFLTLIM | image-flat-shuttle-limits | enumerated integer | 1 |
| IMFLTMOD | image-flat-shuttle-control-mode | enumerated integer | 1 |
| IMFLTMSG | image-flat-shuttle-message | ascii string | 1 |
| IMFLTNAM | imaging-flat | ascii string | 1 |
| IMFLTORD | image-flat-shuttle-ordinal-position | integer | 1 |
| IMFLTRAW | image-flat-shuttle-raw-position | integer | 1 |
| IMFLTSPD | image-flat-shuttle-speed | integer | 1 |
| IMFLTSTA | image-flat-shuttle-status | enumerated integer | 1 |
| IMFLTTOR | image-flat-shuttle-torque | real number | 1 |
| IMFLTTRG | image-flat-shuttle-raw-position-target | integer | 1 |
| IMFLTTSP | image-flat-shuttle-speed-target | integer | 1 |
| IMFLTVAL | image-flat-shuttle-value | real number | 1 |
| IMFLTVEL | image-flat-shuttle-velocity | real number | 1 |
| IMFLTVRB | image-flat-shuttle-verbose-messages | logical | 1 |
| INSTRUME | instrument | ascii string | CCD |
| IONCURMA | ion-pump-current-milliamps | real number | 0 |
| IONCURRA | ion-pump-current-raw | real number | 0 |
| IONPUMP | ion-pump | enumerated integer | 0 |
| KEEPPREP | keep-prescan-pixels | logical | CCD |
| KILLPOW0 | kill-ac-power-0 | logical | 0 |
| KILLPOW1 | kill-ac-power-1 | logical | 1 |
| LAMPAR1 | lamp-argon-1 | logical | 1 |
| LAMPAR2 | lamp-argon-2 | logical | 1 |
| LAMPCU1 | lamp-copper-1 | logical | 1 |
| LAMPCU2 | lamp-copper-2 | logical | 1 |
| LAMPFAN | lamp-fan | logical | 1 |
| LAMPNE1 | lamp-neon-1 | logical | 1 |
| LAMPNE2 | lamp-neon-2 | logical | 1 |
| LAMPQTZ1 | lamp-quartz-1 | logical | 1 |
| LDFLTBRK | low-dispersion-flat-shuttle-brake | logical | 1 |
| LDFLTCAL | low-dispersion-flat-shuttle-calibration | logical | 1 |
| LDFLTDMP | low-dispersion-flat-shuttle-dump | logical | 1 |
| LDFLTERR | low-dispersion-flat-shuttle-error-number | integer | 1 |
| LDFLTFIP | low-dispersion-flat-shuttle-fiducial-light-sensor | logical | 1 |
| LDFLTFOP | low-dispersion-flat-shuttle-fiducial-light-source | logical | 1 |
| LDFLTLCK | low-dispersion-flat-shuttle-lock | ascii string | 1 |
| LDFLTLIM | low-dispersion-flat-shuttle-limits | enumerated integer | 1 |
| LDFLTMOD | low-dispersion-flat-shuttle-control-mode | enumerated integer | 1 |
| LDFLTMSG | low-dispersion-flat-shuttle-message | ascii string | 1 |
| LDFLTNAM | low-dispersion-flat | ascii string | 1 |
| LDFLTORD | low-dispersion-flat-shuttle-ordinal-position | integer | 1 |
| LDFLTRAW | low-dispersion-flat-shuttle-raw-position | integer | 1 |
| LDFLTSPD | low-dispersion-flat-shuttle-speed | integer | 1 |
| LDFLTSTA | low-dispersion-flat-shuttle-status | enumerated integer | 1 |
| LDFLTTOR | low-dispersion-flat-shuttle-torque | real number | 1 |
| LDFLTTRG | low-dispersion-flat-shuttle-raw-position-target | integer | 1 |
| LDFLTTSP | low-dispersion-flat-shuttle-speed-target | integer | 1 |
| LDFLTVAL | low-dispersion-flat-shuttle-value | real number | 1 |
| LDFLTVEL | low-dispersion-flat-shuttle-velocity | real number | 1 |
| LDFLTVRB | low-dispersion-flat-shuttle-verbose-messages | logical | 1 |
| LFRAMENO | last-frame-number | integer | CCD |
| LTODISK | last-to-disk | logical | CCD |
| MANU0CON | controller-0-manual-control-switch-state | logical | 0 |
| MANU1CON | controller-1-manual-control-switch-state | logical | 1 |
| MPPMODE | mpp-readout-mode | logical | CCD |
| NSUBINT | number-of-subintegrations | integer | CCD |
| NUMAMPS | number-of-readout-amplifiers | integer | CCD |
| OBJECT | object | ascii string | CCD |
| OBSERVER | observer | ascii string | CCD |
| OBSTYPE | obstype | ascii string | CCD |
| OUTDIR | readout-directory | ascii string | CCD |
| OUTFILE | readout-filename | ascii string | CCD |
| OVRFLUSH | postscan-flush-lines | integer | CCD |
| PAUSE | pause-exposure | logical | CCD |
| PAUSEIP | pause-in-progress | logical | CCD |
| POSTLINE | postscan-lines | integer | CCD |
| POSTPIX | postscan-pixels | integer | CCD |
| POW05S0V | motor-controller-0-electronics-5-volt-power-supply-voltage | real number | 0 |
| POW05S1V | motor-controller-1-electronics-5-volt-power-supply-voltage | real number | 1 |
| POW12S0R | motor-controller-0-electronics-12-volt-power-raw | real number | 0 |
| POW12S1R | motor-controller-1-electronics-12-volt-power-raw | real number | 1 |
| POW28S0R | motor-controller-0-electronics-28-volt-power-raw | real number | 0 |
| POW28S0V | motor-controller-0-electronics-28-volt-power-supply-voltage | real number | 0 |
| POW28S1R | motor-controller-1-electronics-28-volt-power-raw | real number | 1 |
| POW28S1V | motor-controller-1-electronics-28-volt-power-supply-voltage | real number | 1 |
| PREFLUSH | prescan-flush-lines | integer | CCD |
| PRELINE | prescan-lines | integer | CCD |
| PREPIX | prescan-pixels | integer | CCD |
| PRISMBRK | prism-shuttle-brake | logical | 1 |
| PRISMCAL | prism-shuttle-calibration | logical | 1 |
| PRISMDMP | prism-shuttle-dump | logical | 1 |
| PRISMERR | prism-shuttle-error-number | integer | 1 |
| PRISMFIP | prism-shuttle-fiducial-light-sensor | logical | 1 |
| PRISMFOP | prism-shuttle-fiducial-light-source | logical | 1 |
| PRISMLCK | prism-shuttle-lock | ascii string | 1 |
| PRISMLIM | prism-shuttle-limits | enumerated integer | 1 |
| PRISMMOD | prism-shuttle-control-mode | enumerated integer | 1 |
| PRISMMSG | prism-shuttle-message | ascii string | 1 |
| PRISMNAM | moving-prism | ascii string | 1 |
| PRISMORD | prism-shuttle-ordinal-position | integer | 1 |
| PRISMRAW | prism-shuttle-raw-position | integer | 1 |
| PRISMSPD | prism-shuttle-speed | integer | 1 |
| PRISMSTA | prism-shuttle-status | enumerated integer | 1 |
| PRISMTOR | prism-shuttle-torque | real number | 1 |
| PRISMTRG | prism-shuttle-raw-position-target | integer | 1 |
| PRISMTSP | prism-shuttle-speed-target | integer | 1 |
| PRISMVAL | prism-shuttle-value | real number | 1 |
| PRISMVEL | prism-shuttle-velocity | real number | 1 |
| PRISMVRB | prism-shuttle-verbose-messages | logical | 1 |
| PWINDOW | physical-window | array of integers[5] | CCD |
| PWRBLOK | ccd-dewar-heater-voltage | real number | CCD |
| PWRBLOKM | ccd-dewar-heater-voltage-map | array of real numbers[5] | CCD |
| PWRBLOKR | ccd-dewar-heater-voltage-raw | integer | CCD |
| RCOMMENT | run_comments | ascii string | CCD |
| RESN2LV | ccd-reservoir-nitrogen-level | real number | CCD |
| RESN2LVM | ccd-reservoir-nitrogen-level-map | array of real numbers[5] | CCD |
| RESN2LVR | ccd-reservoir-nitrogen-level-raw | integer | CCD |
| RESUME | resume-exposure | logical | CCD |
| ROWSHFT | row-shift-per-subintegrations | integer | CCD |
| SHUTSTAT | shutter-status | enumerated integer | CCD |
| SHUTTER | shutter | logical | CCD |
| SLMSKCAL | slitmask-calibration | logical | 0 |
| SLMSKDMP | slitmask-dump | logical | 0 |
| SLMSKENC | slitmask-motor-encoder-position | integer | 0 |
| SLMSKERR | slitmask-error-number | integer | 0 |
| SLMSKLCK | slitmask-lock | ascii string | 0 |
| SLMSKMOD | slitmask-control-mode | enumerated integer | 0 |
| SLMSKMSG | slitmask-message | ascii string | 0 |
| SLMSKNAM | slit-wheel | ascii string | 0 |
| SLMSKORD | slitmask-ordinal-position | integer | 0 |
| SLMSKRAW | slitmask-raw-position | integer | 0 |
| SLMSKREN | slitmask-stage-encoder-signal-quality | real number | 0 |
| SLMSKSPD | slitmask-speed | integer | 0 |
| SLMSKSTA | slitmask-status | enumerated integer | 0 |
| SLMSKTOR | slitmask-torque | real number | 0 |
| SLMSKTRG | slitmask-raw-position-target | integer | 0 |
| SLMSKTSP | slitmask-speed-target | integer | 0 |
| SLMSKVAL | slitmask-value | real number | 0 |
| SLMSKVEL | slitmask-velocity | real number | 0 |
| SLMSKVRB | slitmask-verbose-messages | logical | 0 |
| STOPEX | stop-exposure | logical | CCD |
| SYNOPFMT | format_for_SYNOPSIS | ascii string | CCD |
| SYNOPSIS | synopsis_of_FITS_keywords | ascii string | CCD |
| TAPEDEV | tape-device | ascii string | CCD |
| TEMPDET | detector-temperature | real number | CCD |
| TEMPDETM | detector-temperature-map | array of real numbers[5] | CCD |
| TEMPDETR | detector-temperature-raw | integer | CCD |
| TEMPSET | ccd-desired-dewar-temperature | real number | CCD |
| TEMPSETM | ccd-desired-dewar-temperature-map | array of real numbers[5] | CCD |
| TEMPSETR | ccd-desired-dewar-temperature-raw | integer | CCD |
| TMPBOX0C | motor-controller-0-electronics-box-temperature-celsius | real number | 0 |
| TMPBOX0F | motor-controller-0-electronics-box-temperature-fahrenheit | real number | 0 |
| TMPBOX0R | motor-controller-0-electronics-box-temperature-raw | real number | 0 |
| TMPBOX1C | motor-controller-1-electronics-box-temperature-celsius | real number | 1 |
| TMPBOX1F | motor-controller-1-electronics-box-temperature-fahrenheit | real number | 1 |
| TMPBOX1R | motor-controller-1-electronics-box-temperature-raw | real number | 1 |
| TMPCAMC | camera-exterior-temperature-celsius | real number | 0 |
| TMPCAMF | camera-exterior-temperature-fahrenheit | real number | 0 |
| TMPCAMR | camera-exterior-temperature-raw | real number | 0 |
| TMPCIN0C | motor-controller-0-coolant-in-temperature-celsius | real number | 0 |
| TMPCIN0F | motor-controller-0-coolant-in-temperature-fahrenheit | real number | 0 |
| TMPCIN0R | motor-controller-0-coolant-in-temperature-raw | real number | 0 |
| TMPCIN1C | motor-controller-1-coolant-in-temperature-celsius | real number | 1 |
| TMPCIN1F | motor-controller-1-coolant-in-temperature-fahrenheit | real number | 1 |
| TMPCIN1R | motor-controller-1-coolant-in-temperature-raw | real number | 1 |
| TMPCOLLC | collimator-temperature-celsius | real number | 0 |
| TMPCOLLF | motor-controller-0-collimator-temperature-fahrenheit | real number | 0 |
| TMPCOLLR | collimator-temperature-raw | real number | 0 |
| TMPCOU0C | motor-controller-0-coolant-out-temperature-celsius | real number | 0 |
| TMPCOU0F | motor-controller-0-coolant-out-temperature-fahrenheit | real number | 0 |
| TMPCOU0R | motor-controller-0-coolant-out-temperature-raw | real number | 0 |
| TMPCOU1C | motor-controller-1-coolant-out-temperature-celsius | real number | 1 |
| TMPCOU1F | motor-controller-1-coolant-out-temperature-fahrenheit | real number | 1 |
| TMPCOU1R | motor-controller-1-coolant-out-temperature-raw | real number | 1 |
| TMPELE0C | motor-controller-0-electronics-temperature-celsius | real number | 0 |
| TMPELE0F | motor-ontroller-0-electronics-temperature-fahrenheit | real number | 0 |
| TMPELE0R | motor-controller-0-electronics-temperature-raw | real number | 0 |
| TMPELE1C | motor-controller-1-electronics-temperature-celsius | real number | 1 |
| TMPELE1F | motor-controller-1-electronics-temperature-fahrenheit | real number | 1 |
| TMPELE1R | motor-controller-1-electronics-temperature-raw | real number | 1 |
| TMPEXTC | spectrograph-exterior-temperature-celsius | real number | 1 |
| TMPEXTF | spectrograph-exterior-temperature-fahrenheit | real number | 1 |
| TMPEXTR | spectrograph-exterior-temperature-raw | real number | 1 |
| TMPFRM1C | frame-1-temperature-celsius | real number | 1 |
| TMPFRM1F | frame-1-temperature-fahrenheit | real number | 1 |
| TMPFRM1R | frame-1-temperature-raw | real number | 1 |
| TMPFRM2C | frame-2-temperature-celsius | real number | 0 |
| TMPFRM2F | frame-2-temperature-fahrenheit | real number | 0 |
| TMPFRM2R | frame-2-temperature-raw | real number | 0 |
| TMPINTC | spectrograph-interior-temperature-celsius | real number | 0 |
| TMPINTF | spectrograph-interior-temperature-fahrenheit | real number | 0 |
| TMPINTR | spectrograph-interior-temperature-raw | real number | 0 |
| TMPLAMPC | calibration-lamp-temperature-celsius | real number | 1 |
| TMPLAMPF | calibration-lamp-temperature-fahrenheit | real number | 1 |
| TMPLAMPR | calibration-lamp-temperature-raw | real number | 1 |
| TMPOSSC | oss-temperature-celsius | real number | 1 |
| TMPOSSF | oss-temperature-fahrenheit | real number | 1 |
| TMPOSSR | oss-temperature-raw | real number | 1 |
| TMPPRSMC | prism-temperature-celsius | real number | 1 |
| TMPPRSMF | prism-temperature-fahrenheit | real number | 1 |
| TMPPRSMR | prism-temperature-raw | real number | 1 |
| TODISK | to-disk | logical | CCD |
| TOTAPE | to-tape | logical | CCD |
| TTIME | total-time | integer | CCD |
| TVFILCAL | tv-filter-calibration | logical | 0 |
| TVFILDMP | tv-filter-dump | logical | 0 |
| TVFILERR | tv-filter-error-number | integer | 0 |
| TVFILFIP | tv-filter-fiducial-light-sensor | logical | 0 |
| TVFILFOP | tv-filter-fiducial-light-source | logical | 0 |
| TVFILLCK | tv-filter-lock | ascii string | 0 |
| TVFILMOD | tv-filter-control-mode | enumerated integer | 0 |
| TVFILMSG | tv-filter-message | ascii string | 0 |
| TVFILNAM | tv-filter-named-position | ascii string | 0 |
| TVFILORD | tv-filter-ordinal-position | integer | 0 |
| TVFILRAW | tv-filter-raw-position | integer | 0 |
| TVFILSPD | tv-filter-speed | integer | 0 |
| TVFILSTA | tv-filter-status | enumerated integer | 0 |
| TVFILTOR | tv-filter-torque | real number | 0 |
| TVFILTRG | tv-filter-raw-position-target | integer | 0 |
| TVFILTSP | tv-filter-speed-target | integer | 0 |
| TVFILVAL | tv-filter-value | real number | 0 |
| TVFILVEL | tv-filter-velocity | real number | 0 |
| TVFILVRB | tv-filter-verbose-messages | logical | 0 |
| TVFOCCAL | tv-focus-calibration | logical | 0 |
| TVFOCDMP | tv-focus-dump | logical | 0 |
| TVFOCERR | tv-focus-error-number | integer | 0 |
| TVFOCFIP | tv-focus-fiducial-light-sensor | logical | 0 |
| TVFOCFOP | tv-focus-fiducial-light-source | logical | 0 |
| TVFOCLCK | tv-focus-lock | ascii string | 0 |
| TVFOCLIM | tv-focus-limits | enumerated integer | 0 |
| TVFOCMOD | tv-focus-control-mode | enumerated integer | 0 |
| TVFOCMSG | tv-focus-message | ascii string | 0 |
| TVFOCNAM | tv-focus-named-position | ascii string | 0 |
| TVFOCORD | tv-focus-ordinal-position | integer | 0 |
| TVFOCRAW | tv-focus-raw-position | integer | 0 |
| TVFOCSPD | tv-focus-speed | integer | 0 |
| TVFOCSTA | tv-focus-status | enumerated integer | 0 |
| TVFOCTOR | tv-focus-torque | real number | 0 |
| TVFOCTRG | tv-focus-raw-position-target | integer | 0 |
| TVFOCTSP | tv-focus-speed-target | integer | 0 |
| TVFOCVAL | tv-focus-value | real number | 0 |
| TVFOCVEL | tv-focus-velocity | real number | 0 |
| TVFOCVRB | tv-focus-verbose-messages | logical | 0 |
| TVPOWER | TVPOWER | logical | 0 |
| UTB15VEN | ccd-15-volts-enable | logical | CCD |
| UTB30VEN | ccd-30-volts-enable | logical | CCD |
| UTBFANS | ccd-controller-fans | logical | CCD |
| UTBM15V | ccd-minus-15-volts | real number | CCD |
| UTBM15VM | ccd-minus-15-volts-map | array of real numbers[5] | CCD |
| UTBM15VR | ccd-minus-15-volts-raw | integer | CCD |
| UTBN2FIL | ccd-liquid-n2-pressure-valve | logical | CCD |
| UTBN2HTR | ccd-liquid-n2-reservoir-heater | logical | CCD |
| UTBP15V | ccd-plus-15-volts | real number | CCD |
| UTBP15VM | ccd-plus-15-volts-map | array of real numbers[5] | CCD |
| UTBP15VR | ccd-plus-15-volts-raw | integer | CCD |
| UTBP30V | ccd-plus-30-volts | real number | CCD |
| UTBP30VM | ccd-plus-30-volts-map | array of real numbers[5] | CCD |
| UTBP30VR | ccd-plus-30-volts-raw | integer | CCD |
| UTBP5V | ccd-plus-5-volts | real number | CCD |
| UTBP5VM | ccd-plus-5-volts-map | array of real numbers[5] | CCD |
| UTBP5VR | ccd-plus-5-volts-raw | integer | CCD |
| UTBTEMP | ccd-utility-board-temperature | real number | CCD |
| UTBTEMPM | ccd-utility-board-temperature-map | array of real numbers[5] | CCD |
| UTBTEMPR | ccd-utility-board-temperature-raw | integer | CCD |
| UTBTMPS | ccd-desired-utility-board-temperature | real number | CCD |
| UTBTMPSM | ccd-desired-utility-board-temperature-map | array of real numbers[5] | CCD |
| UTBTMPSR | ccd-desired-utility-board-temperature-raw | integer | CCD |
| VOFFSET0 | video-offset-amplifier-0 | integer | CCD |
| VOFFSET1 | video-offset-amplifier-1 | integer | CCD |
| VOFFSET2 | video-offset-amplifier-2 | integer | CCD |
| VOFFSET3 | video-offset-amplifier-3 | integer | CCD |
| WCRATE | writing-crate-memory | logical | CCD |
| WDISK | writing-disk | logical | CCD |
| WINDOW | window | array of integers[5] | CCD |
| XFLIP | camera-x-flip | logical | CCD |