The following sources provide data on stars which may be suitable for spectrophotometric flux calibrations. Note that most of these stars can be found in the starlist
/kroot/starlists/0000spectraphoto.stds
| Star | RA (2000) |
Dec (2000) |
Spec Type |
V aprox. |
MIN λ | MAX λ | References |
|---|---|---|---|---|---|---|---|
| G158-100 | 00:33:54.3 | -12:07:57 | sdG | 14.89 | 3200 | 9200 | 1 |
| LTT 377 | 00:41:46.6 | -33:39:10 | f | 11.2 | 3200 | 8370 | 4 |
| 92-507 | 00:56:51 | +01:06 | 11.33 | 0.93 | 3850 | 8850 | 3 |
| 92-508 | 00:56:51 | +01:10 | 11.68 | 0.53 | 3850 | 8850 | 3 |
| Feige 11 | 01:04:21.6 | +04:13:37 | sdB | 12.07 | 3850 | 8850 | 3 |
| Hiltner 102 | 01:09:04.9 | +62:47:29 | BO III | 10.35 | 3200 | 8370 | 2 |
| Feige 15 | 01:49:09.4 | +13:33:12 | A1 V | 10.41 | 3200 | 8370 | 2 |
| LTT 1020 | 01:54:49.7 | -27:28:29 | g | 11.5 | 3200 | 8370 | 4 |
| PG 0205+134 | 02:08:03.44 | +13:36:30.9 | sdOB | 14.87 | 3200 | 8100 | 5 |
| PG 0216+032 | 02:19:18.9 | +03:26:53.9 | sdOC | 14.79 | 3200 | 8100 | 5 |
| xi² Cet | 02:28:09.5 | +08:27:36 | B9 III | 4.29 | 3850 | 8850 | 3 |
| Feige 25 | 02:38:37.6 | +05:27:55 | B6 V | 12.01 | 3200 | 8370 | 2 |
| EG 21 | 03:10:30.4 | -68:36:05 | DA | 11.4 | 3200 | 8370 | 4 |
| PG 0310+149 | 03:13:36.95 | +15:06:23.9 | sdO | 15.63 | 3200 | 8100 | 5 |
| LTT 1788 | 03:48:22.2 | -39:08:35 | f | 13.1 | 3200 | 8370 | 4 |
| GD 50 | 03:48:50.0 | -00:58:29 | DA2 | 14.06 | 3850 | 8850 | 1,3 |
| SA95-42 | 03:53:43.7 | -00:04:33 |   | 15.61 | 3200 | 9200 | 1 |
| 95-52 | 03:54:14 | -00:08 | 9.57 | 0.53 | 3850 | 8850 | 3 |
| 95-86 | 03:52:23 | +00:05 | 14.51 | 1.00 | 3850 | 8850 | 3 |
| 95-233 | 03:55:56 | +00:12 | 11.00 | 0.68 | 3850 | 8850 | 3 |
| 95-301 | 03:52:41 | +00:31 | 11.22 | 1.29 | 3850 | 8850 | 3 |
| 95-302 | 03:52:42 | +00:31 | 11.69 | 0.83 | 3850 | 8850 | 3 |
| 95-317 | 03:53:44 | +00:30 | 13.45 | 1.32 | 3850 | 8850 | 3 |
| 95-330 | 03:54:31 | +00:29 | 12.17 | 2.00 | 3850 | 8850 | 3 |
| 95-132 | 03:54:31 | +00:05 | 12.06 | 0.45 | 3850 | 8850 | 3 |
| 95-218 | 03:54:50 | +00:10 | 12.10 | 0.71 | 3850 | 8850 | 3 |
| 95-275 | 03:54:44 | +00:27 | 13.48 | 1.76 | 3850 | 8850 | 3 |
| HZ 4 | 03:55:21.7 | +09:47:18 | DA4 | 14.52 | 3850 | 8850 | 1,3 |
| HD 27836 | 04:24:12.1 | +14:45:30 | G1 V | 7.62 | 3850 | 8850 | 3 |
| HZ 14 | 04:41:01.5 | +10:59:41.3 | dA | 14.01 | 3200 | 8100 | 5 |
| HZ 15 | 04:40:39.3 | +08:40:46 | B5 | 12.59 | 3200 | 8370 | 2 |
| 96-736 | 04:52:35 | +00:22 | 11.92 | 0.44 | 3850 | 8850 | 3 |
| 96-737 | 04:52:35 | +00:22 | 11.72 | 1.33 | 3850 | 8850 | 3 |
| G191B2B | 05:05:30.3 | +52:49:54 | DA0 | 11.78 | 3850 | 8850 | 1,3,5, 6 |
| LTT 2415 | 05:56:24.3 | -27:51:26 | - | 12.2 | 3200 | 8370 | 4 |
| LTT 2511 see Note |
06:16:14.2 | -59:12:23 | a | 13.9 | 3200 | 8370 | 4 |
| Hiltner 600 | 06:45:13.40 | +02:08:14.1 | B1V | 10.45 | 3200 | 10300 | 5, 6, 2 |
| 98-600 | 06:51:45 | -00:26 | 11.11 | 0.57 | 3850 | 8850 | 3 |
| 98-607 | 06:51:48 | -00:26 | 11.15 | 0.16 | 3850 | 8850 | 3 |
| 98-613 | 06:51:49 | -00:27 | 11.81 | 0.17 | 3850 | 8850 | 3 |
| 98-632 | 06:51:55 | -00:26 | 11.54 | 0.15 | 3850 | 8850 | 3 |
| L745-46A | 07:40:19.6 | -17:24:42 | DF | 13.0 | 3200 | 8370 | 4 |
| G193-74 | 07:53:27.4 | +52:29:36 | DC | 15.70 | 3200 | 9200 | 1 |
| 99-6 | 07:53:33 | -00:50 | 11.05 | 1.26 | 3850 | 8850 | 3 |
| 99-8 | 07:53:34 | -00:52 | 11.53 | 0.76 | 3850 | 8850 | 3 |
| 99-12 | 07:53:42 | -00:49 | 12.37 | 0.46 | 3850 | 8850 | 3 |
| 99-14 | 07:53:45 | -00:49 | 12.54 | 0.88 | 3850 | 8850 | 3 |
| BD+75° 325 | 08:10:49.3 | +74:57:57 | O5p | 9.54 | 3200 | 9200 | 1 |
| BD+08° 2015 | 08:15:42.4 | +07:37:14 | G2: V | 10.39 | 3200 | 8370 | 2 |
| PG 0823+546 | 08:26:50.4 | +54:28:05.6 | sdOC | 14.36 | 3200 | 10300 | 5,6 |
| LTT 3218 | 08:41:33.6 | -32:56:54 | DA | 11.8 | 3200 | 8370 | 4 |
| PG 0846+249 | 08:49:04.7 | +24:45:15.6 | DA1 | 16.94 | 3200 | 8100 | 5 |
| PG 0918+029 | 09:21:27.8 | +02:46:06 | ... | 13.33 | 3850 | 8850 | 3 |
| PG 0934+554 | 09:38:19.9 | +55:05:42.7 | sdO | 12.16 | 3200 | 8100 | 5 |
| PG 0939+262 | 09:42:51.16 | +26:00:57.5 | DA1 | 14.89 | 3200 | 8100 | 5 |
| 101-88 | 09:54:42 | -00:52 | 11.25 | 0.97 | 3850 | 8850 | 3 |
| 101-207 | 09:59:10 | -00:55 | 12.42 | 0.52 | 3850 | 8850 | 3 |
| 101-327 | 09:56:09 | -00:26 | 13.44 | 1.16 | 3850 | 8850 | 3 |
| 101-329 | 09:56:19 | -00:26 | 11.99 | 0.64 | 3850 | 8850 | 3 |
| 101-330 | 09:56:21 | -00:27 | 13.72 | 0.58 | 3850 | 8850 | 3 |
| 101-363 | 09:58:19 | -00:26 | 9.87 | 0.26 | 3850 | 8850 | 3 |
| 101-429 | 09:57:32 | -00:18 | 13.50 | 0.98 | 3850 | 8850 | 3 |
| 101-431 | 09:57:37 | -00:18 | 13.68 | 1.25 | 3850 | 8850 | 3 |
| GD 108 | 10:00:47.3 | -07:33:31 | sdB? | 13.56 | 3200 | 9200 | 1,3 |
| LTT 3864 | 10:32:13.8 | -35:37:42 | f | 12.1 | 3200 | 8370 | 4 |
| G162-66 | 10:33:43.6 | -11:41:42 | DA2 | 13.01 | 3850 | 8850 | 3 |
| PG 1034+001 | 10:37:04.0 | -00:08:20 | DO | 13.23 | 3850 | 8850 | 3 |
| Feige 34 | 10:39:36.7 | +43:06:10 | DO | 11.18 | 3200 | 10300 | 1,3,5,6 |
| HD 93521 | 10:48:23.5 | +37:34:13 | O9Vp | 7.04 | 3200 | 9200 | 1 |
| HD 93521 | 10:48:23.4 | +37:34:13 | O9 Vp | 7.04 | 3850 | 8850 | 3 |
| G163-50 | 11:07:59.3 | -05:09:10 | DA4 | 13.06 | 3850 | 8850 | 3 |
| G163-51 | 11:08:06.3 | -05:13:27 | M6 V | 12.58 | 3850 | 8850 | 3 |
| PG 1121+145 | 11:24:15.9 | +14:13:48.8 | DA1 | 16.97 | 3200 | 8100 | 5 |
| GD 140 | 11:37:05.28 | +29:47:50.3 | DA2 | 12.50 | 3200 | 10300 | 5,6 |
| EG 81 | 11:37:26.79 | +14:10:21.2 | sdO | 13.30 | 3200 | 8100 | 5 |
| theta Crt | 11:36:41.0 | -09:48:08 | B9.5 Vn | 4.70 | 3850 | 8850 | 3 |
| LTT 4364 | 11:45:36.6 | -64:50:24 | C_2 | 11.5 | 3200 | 8370 | 4 |
| Feige 56 | 12:06:47.2 | +11:40:13 | B5p | 11.11 | 3200 | 8370 | 2 |
| HZ 21 | 12:13:56.3 | +32:56:26 | DO2 | 14.68 | 3850 | 8850 | 1, 3 |
| LTT 4816 | 12:38:50.7 | -49:47:58 | DA | 13.8 | 3200 | 8370 | 4 |
| Feige 66 | 12:37:23.6 | +25:04:00 | sdO | 10.50 | 3200 | 10300 | 1,3,5,6 |
| Feige 67 | 12:41:51.8 | +17:31:20 | sdO | 11.81 | 3200 | 10300 | 1,3,5,6 |
| 104-335 | 12:42:22 | -00:33 | 11.67 | 0.62 | 3850 | 8850 | 3 |
| 104-337 | 12:42:28 | -00:34 | 11.22 | 0.77 | 3850 | 8850 | 3 |
| 104-428 | 12:41:41 | -00:26 | 12.63 | 0.99 | 3850 | 8850 | 3 |
| 104-439 | 12:42:13 | -00:30 | 11.33 | 0.79 | 3850 | 8850 | 3 |
| 104-453 | 12:42:46 | -00:26 | 12.24 | 0.77 | 3850 | 8850 | 3 |
| 104-454 | 12:42:53 | -00:26 | 11.94 | 0.75 | 3850 | 8850 | 3 |
| 104-460 | 12:43:03 | -00:28 | 12.89 | 1.29 | 3850 | 8850 | 3 |
| G60-54 | 13:00:09.5 | +03:28:56 | DC | 15.81 | 3200 | 9200 | 1 |
| HZ 44 | 13:23:35.4 | +36:08:00 | sdO | 11.66 | 3200 | 9200 | 1, 3, 5, 6 |
| PG 1323-086 | 13:25:39.4 | -08:49:18 | sdB-O | 13.48 | 3850 | 8850 | 3 |
| Grw+70 5824 | 13:38:51.8 | +70:17:08 | DA3 | 12.77 | 3200 | 9200 | 1 |
| 105-595 | 13:39:58 | -00:29 | 11.62 | 0.69 | 3850 | 8850 | 3 |
| 105-599 | 13:40:03 | -00:28 | 11.70 | 0.62 | 3850 | 8850 | 3 |
| 105-600 | 13:40:15 | -00:29 | 11.84 | 0.56 | 3850 | 8850 | 3 |
| CD-22° 3927 | 14:11:46.3 | -33:03:15 | A0 | 10.4 | 3200 | 8370 | 4 |
| Feige 92 | 14:11:31.868 | +50:07:04.14 | Bp | 11.62 | 3200 | 8370 | 2 |
| Feige 98 | 14:38:15.8 | +27:29:33 | B7 | 11.84 | 3200 | 8370 | 2 |
| LTT 6248 | 15:38:59.8 | -28:35:34 | a | 11.8 | 3200 | 8370 | 4 |
| 107-351 | 15:38:46 | -00:32 | 12.34 | 0.56 | 3850 | 8850 | 3 |
| 107-365 | 15:39:29 | -00:30 | 11.60 | 1.10 | 3850 | 8850 | 3 |
| 107-452 | 15:38:37 | -00:23 | 11.04 | 1.07 | 3850 | 8850 | 3 |
| 107-456 | 15:38:43 | -00:20 | 12.92 | 0.92 | 3850 | 8850 | 3 |
| 107-465 | 15:39:20 | -00:27 | 11.60 | 0.55 | 3850 | 8850 | 3 |
| 107-469 | 15:39:39 | -00:27 | 12.17 | 0.58 | 3850 | 8850 | 3 |
| 107-568 | 15:37:53 | -00:17 | 13.05 | 1.15 | 3850 | 8850 | 3 |
| 107-596 | 15:39:03 | -00:14 | 11.39 | 0.56 | 3850 | 8850 | 3 |
| 107-601 | 15:39:14 | -00:13 | 14.65 | 1.41 | 3850 | 8850 | 3 |
| 107-602 | 15:39:19 | -00:15 | 12.12 | 0.99 | 3850 | 8850 | 3 |
| 107-619 | 15:39:51 | -00:18 | 12.12 | 0.62 | 3850 | 8850 | 3 |
| 107-626 | 15:40:06 | -00:17 | 13.47 | 1.00 | 3850 | 8850 | 3 |
| 107-627 | 15:40:08 | -00:17 | 13.35 | 0.78 | 3850 | 8850 | 3 |
| 107-990 | 15:38:00 | +02:19 | 9.56 | 0.49 | 3850 | 8850 | 3 |
| PG 1545+035 | 15:48:24.25 | +03:22:54.0 | sdOB | 14.34 | 3200 | 8100 | 5 |
| BD+33° 2642 | 15:51:59.0 | +32:57:01 | B2 IV | 10.81 | 3850 | 8850 | 2, 3 |
| G153-41 | 16:17:55.4 | -15:35:47 | DA2 | 13.42 | 3850 | 8850 | 3 |
| EG 274 | 16:23:33.7 | -39:13:48 | DA | 11.0 | 3200 | 8370 | 4 |
| G138-31 | 16:27:53.6 | +09:12:24 | DA7 | 16.14 | 3200 | 9200 | 1 |
| 108-468 | 16:36:54 | -00:33 | 12.07 | 0.69 | 3850 | 8850 | 3 |
| 108-475 | 16:37:00 | -00:35 | 11.31 | 1.38 | 3850 | 8850 | 3 |
| PG 1708+602 | 17:09:15.84 | +60:10:10.5 | sdOC | 13.92 | 3200 | 8100 | 5 |
| Kopff 27 | 17:43:55.8 | +05:24:48 | A3 V | 10.31 | 3200 | 8370 | 2 |
| 109-949 | 17:44:13 | -00:02 | 12.83 | 0.81 | 3850 | 8850 | 3 |
| 109-954 | 17:44:15 | -00:02 | 12.44 | 1.30 | 3850 | 8850 | 3 |
| 109-956 | 17:44:17 | -00:03 | 14.64 | 1.28 | 3850 | 8850 | 3 |
| 109-959 | 17:44:18 | -00:02 | 12.79 | 0.92 | 3850 | 8850 | 3 |
| LTT 7379 | 18:36:26.2 | -44:18:37 | G0 | 10.2 | 3200 | 8370 | 4 |
| 110-499 | 18:43:07 | +00:28 | 11.74 | 0.99 | 3850 | 8850 | 3 |
| 110-502 | 18:43:10 | +00:28 | 12.33 | 2.33 | 3850 | 8850 | 3 |
| 110-503 | 18:43:11 | +00:30 | 11.77 | 0.67 | 3850 | 8850 | 3 |
| 110-506 | 18:43:19 | +00:30 | 11.31 | 0.57 | 3850 | 8850 | 3 |
| 110-507 | 18:43:19 | +00:29 | 12.44 | 1.14 | 3850 | 8850 | 3 |
| 111-1925 | 19:37:29 | +00:25 | 12.39 | 0.40 | 3850 | 8850 | 3 |
| 111-1965 | 19:37:42 | +00:27 | 11.42 | 1.71 | 3850 | 8850 | 3 |
| 111-1969 | 19:37:44 | +00:26 | 10.38 | 1.96 | 3850 | 8850 | 3 |
| 16 Cyg B | 19:41:52.0 | +50:31:03 | G5 V | 6.20 | 3850 | 8850 | 3 |
| BD+25° 3941 | 19:44:26.1 | +26:13:17 | B1.5 V | 10.36 | 3200 | 8370 | 2 |
| BD+40° 4032 | 20:08:24.3 | +41:15:03 | B2 III | 10.45 | 3200 | 8370 | 2 |
| HD 192281 | 20:12:33.14 | +40:16:05.6 | O5f | 7.44 | 3200 | 8100 | 5 |
| LTT 7987 | 20:10:57.1 | -30:13:03 | DA | 12.2 | 3200 | 8370 | 4 |
| Cyg OB2 No.9 | 20:33:10.73 | +41:15:08.0 | O5If | 10.70 | 3200 | 8100 | 5 |
| Wolf 1346 | 20:34:21.88 | +25:03:49.7 | DA | 11.54 | 3200 | 10300 | 5,6 |
| 112-805 | 20:42:46 | +00:16 | 12.09 | 0.15 | 3850 | 8850 | 3 |
| 112-810 | 20:42:50 | +00:17 | 10.58 | 1.16 | 3850 | 8850 | 3 |
| 112-822 | 20:42:55 | +00:15 | 11.55 | 1.03 | 3850 | 8850 | 3 |
| 113-221 | 21:40:36 | +00:21 | 12.07 | 1.03 | 3850 | 8850 | 3 |
| 113-241 | 21:41:09 | +00:26 | 14.35 | 1.34 | 3850 | 8850 | 3 |
| 113-260 | 21:41:48 | +00:24 | 12.41 | 0.51 | 3850 | 8850 | 3 |
| 113-339 | 21:40:56 | +00:28 | 12.25 | 0.57 | 3850 | 8850 | 3 |
| 113-342 | 21:41:00 | +00:28 | 10.88 | 1.02 | 3850 | 8850 | 3 |
| 113-442 | 21:40:40 | +00:45 | 9.62 | 1.16 | 3850 | 8850 | 3 |
| BD +28°4211 see note |
21:51:11.5 | +28:51:49 | sdOp | 10.53 | 3200 | 10300 | 1, 2,3, 5,6 |
| G93-48 | 21:52:25.3 | +02:23:32 | DA3 | 12.74 | 3850 | 8850 | 3 |
| BD+25° 4655 | 21:59:42.0 | +26:25:57 |   |   | 3200 | 9200 | 1 |
| NGC 7293 | 22:29:38.5 | -20:50:13 |   | 13.51 | 3200 | 9200 | 1 |
| LTT 9239 | 22:52:40.9 | -20:35:27 | f | 12.0 | 3200 | 8370 | 1,4 |
| HD 217086 | 22:56:47.09 | +62:43:38.2 | O5 | 7.49 | 3200 | 8100 | 5 |
| LTT 9491 | 23:19:35.2 | -17:05:28 | DC | 14.1 | 3200 | 8370 | 4 |
| Feige 110 | 23:19:58.4 | -05:09:56 | DOp | 11.82 | 3200 | 10300 | 1, 2,3,5,6 |
| GD 248 | 23:26:06.7 | +16:00:21 | DC | 15.09 | 3200 | 9200 | 1 |