wfready -- checks and waits for detector to be ready before starting exposure
NAME
wfready -- checks and waits for detector to be ready before starting exposure
WFREADY - OSIRIS library of scripts
SYNOPSIS
wfready mode [-t #]
DESCRIPTION
waits for SPEC or IMAG detector to be ready to start a new exposure
(by monitoring sready or iready keyword) and then exits.
if waiting period exceeds a threshold, then wfready times out and exits
with an error code.
OPTIONS
mode
specifies detector, can be "SPEC" or "IMAG"
-t NUM
ID number to attach to all script generated errors, warnings, and
questions that are passed to the OGS. The ID number is separated
from the rest of the message with a ";".
EXAMPLES
wfready imag
Waits for IMAG detector to be ready
ENIVIRONMENT VARIABLES
none
FILES
none
SERVERS & KEYWORDS
service = osiris
keywords: sready/iready
SCRIPTS CALLED
help, syncheck
EXIT STATUS
0 - normal exit, no error
1 - script aborted by an interrupt
2 - syncheck error
3 - error parsing command line input
4 - time out error
SEE ALSO
???