wfao -- waits for AO loops to close
NAME
wfao -- waits for AO loops to close
OSIRIS library of scripts
SYNOPSIS
wfao [-noask] [-t #]
DESCRIPTION
waits for the AO tip/tilt and deformable mirror loops to close.
Note that the behavior is controllable through the keywords:
WFTT wait for tip-tilt
WFDM wait for deformable mirror
WFDAR offload DAR (differential atmospheric refraction) moves
OPTIONS
-noask
if this flag is given, wfao will not ask the user whether to
continue if a waitfor timeout is reached - it will simply exit
with an error code
-t NUM
ID number to attach to all script generated errors, warnings, and
questions that are passed to the OGS. The ID number is separated
from the rest of the message with a ";". ID number is needed for
use with the ODEC, not needed if used from the command line.
EXAMPLES
wfao -t 123456
ENVIRONMENT VARIABLES
none
FILES
none
SERVERS & KEYWORDS
service = osiris
keywords: wftt, wfdm, wfdar, AOTTOFLD, aodelay,
script...
service = ao
keywords: dtclxoff, dtclyoff, aowfslav, obfmgoim, aodtstat,
aodmstat, obwfstst,
SCRIPTS CALLED
help, syncheck
EXIT STATUS
0 - normal exit, no error
1 - script aborted by an interrupt
2 - syncheck error
3 - error accessing servers
4 - error with a wf flag
5 - timed out waiting for
SEE ALSO
???
See Also
The shell script wfao
OSIRIS script index
Go to:
OSIRIS Home Page -
Instruments Home Page -
Keck Home Page
Last modified: Wed Apr 28 03:39:12 2021