OSIRIS
osirisSetTargwave script

osirisSetTargwave -- sets DCS targwave keywords based on filter

NAME

osirisSetTargwave -- sets DCS targwave keywords based on filter

OSIRIS library of scripts



SYNOPSIS

osirisSetTargwave filter [-m]

DESCRIPTION

based on the filter name provided, the script looks up the info for that
filter and sets the DCS targwave keyword. if in NGS mode, the script
then triggers offloading of any resulting DAR (differential atmospheric
refraction). the triggering is not needed if in LGS mode.

OPTIONS

filter
the name of the filter being used

-m
simulate calls to RPC servers. during simulated calls, the
command is echoed (instead of being executed).

EXAMPLES

osirisSetTargwave Kn1
sets DCS targwave to 2.0048

ENVIRONMENT VARIABLES

none

FILES

osirisFilterSpecs.dat

SERVERS & KEYWORDS

service = dcs
keywords: targwave

SCRIPTS CALLED

list of the scripts called by this script, for example:

help, syncheck

EXIT STATUS

0 - normal exit, no error
1 - script aborted by an interrupt
2 - syncheck error
3 - error parsing command line input
other errors...

SEE ALSO

???

See Also

The shell script osirisSetTargwave
OSIRIS script index


Go to: OSIRIS Home Page - Instruments Home Page - Keck Home Page

Last modified: Fri Feb 18 02:51:29 2022