osirisPause -- pauses osirisTakeDataset after current SPEC exposure
NAME
osirisPause -- pauses osirisTakeDataset after current SPEC exposure
osirisPause - OSIRIS library of scripts
SYNOPSIS
osirisPause [-t #] [-m]
DESCRIPTION
this script is intended to be called by the OSIRIS Dataset Execution
Client (ODEC) in order to pause the current dataset after the current
SPEC exposure finishes. it sets the appropriate keyword in the OSIRIS
Global Server (OGS) to trigger this behavior and sends a message
acknowledging receipt of the abort to the observer.
OPTIONS
-t #
ID number to attach to all script generated errors, warnings, and
questions that are passed to the OGS. The ID number is separated
from the rest of the message with a ";".
-m
simulate calls to RPC servers. during simulated calls, the
command is echoed (instead of being executed).
EXAMPLES
osirisPause -t 123
Pause the current dataset and attach "123" to all messages to OGS
ENVIRONMENT VARIABLES
none
FILES
none
SERVERS & KEYWORDS
service = osiris
keywords: scriptwait, scriptwarn
SCRIPTS CALLED
help, syncheck
EXIT STATUS
0 - normal exit, no error
1 - script aborted by an interrupt
2 - syncheck error
3 - error parsing command line input
SEE ALSO
???
See Also
The shell script osirisPause
OSIRIS script index
Go to:
OSIRIS Home Page -
Instruments Home Page -
Keck Home Page
Last modified: Fri Feb 18 02:51:29 2022