osirisAutoRamp -- configure exposure based on itime
NAME
osirisAutoRamp -- configure exposure based on itime
OSIRIS library of scripts
SYNOPSIS
osirisAutoRamp mode [-t #] [-m] itimeInSeconds
DESCRIPTION
Determines optimal exposure ramp (configuration) based on the
the integration time passed in as a float in seconds. It then
sets the appropriate keywords: itime, sampmode, groups, reads.
Currently, the algorithm is as follows:
- MCDS will be used always.
- The maximum number of read pairs that fit within the integration time
will be used up to the limit of 64.
This script assumes full frames. Read time obtained from server
(readtime keyword).
OPTIONS
mode
specfies detector, "SPEC" or "IMAG".
itimeInSeconds
specifies integration time seconds as a float
-t NUM
ID number to attach to all script generated errors, warnings, and
questions that are passed to the OGS. The ID number is separated
from the rest of the message with a ";".
-m
simulate the exposure - do not actually set keywords.
during simulated mode the setting of keywords will be
echoed to the screen.
EXAMPLES
osirisAutoRamp IMAG 5.7 -m
Takes 3 simulated IMAG exposures
FILES
none
SEE ALSO
???
See Also
The shell script osirisAutoRamp