# NOTE: this version of the linelist has been modified # to (a) exclude all lines with intensity less than 10 # and (b) combine all P1/P2 pairs of unresolved lines. # Combined lines are indentified below as 'blend' and # the listed wavelengths are the simple average of the # two components. The command used to modify the # linelist was: # awk -f lowd_ir_ohlines.awk ir_ohlines.dat > lowd_ir_ohlines.dat # GDW 2001-Jan-08 #----------------------------------------------------------------------- # This file contains most of the night sky OH lines. # All the lines belonging to the sequence Delta V=2 to 5, up # to V'=9 are included. All the levels with the rotational quantum # number J lower than or equal to 16.5 have been considered. # # The different columns contain the following data : # # 1: Wavelengths in vacuum (Angstroms) # 2: Theoretical intensity, in relative units proportional to the # flux of photons. The absolute flux is arbitrary. # # These data have been computed by Philippe Rousselot (Observatory # of Besancon, France). The computations are based on the energy levels # published by Abrams et al., 1994 (Ap.J. Suppl. Seris 93, 351-395) # and on the transition probabilities published by Mies, 1974 (J. # of Mol. Spec. 53, 150-188). The upper relative populations have # been computed by assuming a Boltzmann distribution with a rotational # temperature equal to 190 K and a vibrational temperature equal to # 9000 K. These values are approximate and the resulting relative # intensities should be regarded as indicative. The accuracy of # the wavelengths is of the order of a few hundredth of Angstroms. # # If you have any questions or comments concerning this list you # can send an E-mail to philippe@obs-besancon.fr. # # If you use this list for your work and puslish it, please refer to: # Rousselot et al., 2000, A & A, in press # 7915.885 1.663e+01 blend 7966.841 1.236e+01 blend 7995.531 1.351e+01 blend 8290.881 1.165e+01 blend 8301.177 1.356e+01 blend 8346.896 3.437e+01 blend 8355.162 1.283e+01 blend 8401.478 2.518e+01 blend 8432.491 2.790e+01 blend 8467.684 1.975e+01 blend 8507.178 1.036e+01 blend 8763.720 1.042e+01 blend 8770.320 1.821e+01 blend 8780.744 2.049e+01 blend 8829.519 5.045e+01 blend 8838.864 1.932e+01 blend 8870.018 1.091e+01 blend 8888.289 3.664e+01 blend 8905.559 1.439e+01 blend 8922.084 4.140e+01 blend 8945.851 1.208e+01 blend 8960.543 3.020e+01 blend 9003.817 1.647e+01 blend 9309.925 1.499e+01 blend 9315.901 2.493e+01 blend 9326.287 2.699e+01 blend 9378.533 6.468e+01 blend 9389.284 2.545e+01 blend 9422.314 1.388e+01 blend 9442.240 4.656e+01 blend 9461.123 1.862e+01 blend 9479.454 5.379e+01 blend 9505.422 1.609e+01 blend 9521.966 4.057e+01 blend 9555.155 1.027e+01 blend 9569.963 2.313e+01 blend 9623.604 1.040e+01 blend 9684.900 1.524e+01 blend 9701.998 3.179e+01 blend 9714.370 1.320e+01 blend 9722.497 4.080e+01 blend 9740.761 1.485e+01 blend 9792.100 1.203e+01 blend 9793.803 1.102e+02 blend 9802.357 3.812e+01 blend 9814.675 1.203e+01 blend 9851.185 2.438e+01 blend 9874.844 8.159e+01 blend 9897.458 3.006e+01 blend 9917.390 8.429e+01 blend 9944.370 2.197e+01 blend 9944.919 1.065e+01 blend 9947.989 2.247e+01 blend 9949.236 3.465e+01 blend 9959.307 3.600e+01 blend 9959.383 1.358e+01 blend 9964.662 5.412e+01 blend 9975.083 1.255e+01 blend 10002.737 1.169e+01 blend 10015.555 8.356e+01 blend 10016.731 2.494e+01 blend 10028.200 3.386e+01 blend 10046.266 1.324e+01 blend 10063.472 1.780e+01 blend 10085.231 5.957e+01 blend 10106.374 2.430e+01 blend 10126.784 7.049e+01 blend 10155.755 2.167e+01 blend 10161.266 1.763e+01 blend 10174.488 5.508e+01 blend 10174.898 4.820e+01 blend 10183.825 2.222e+01 blend 10192.499 9.538e+01 blend 10205.844 3.912e+01 blend 10211.576 1.446e+01 blend 10213.851 1.179e+02 blend 10228.587 3.291e+01 blend 10233.464 4.245e+01 blend 10287.588 3.340e+01 blend 10288.921 1.571e+01 solo 10289.458 3.077e+02 blend 10289.670 1.571e+01 solo 10295.345 1.005e+01 blend 10298.845 1.093e+02 blend 10312.344 3.568e+01 blend 10330.129 1.002e+01 blend 10350.127 6.729e+01 blend 10375.720 2.246e+02 blend 10399.386 8.414e+01 blend 10421.218 2.370e+02 blend 10453.365 6.458e+01 blend 10471.831 1.568e+02 blend 10512.012 3.492e+01 blend 10527.657 7.527e+01 blend 10575.401 1.393e+01 blend 10588.762 2.737e+01 blend 10700.044 3.086e+01 blend 10706.409 1.548e+01 blend 10713.681 8.003e+01 blend 10723.351 3.654e+01 blend 10731.714 1.517e+02 blend 10746.152 6.168e+01 blend 10753.920 1.815e+02 blend 10775.059 6.487e+01 blend 10832.257 4.993e+01 blend 10834.289 4.629e+02 blend 10840.781 1.518e+01 blend 10844.693 1.686e+02 blend 10859.628 5.691e+01 blend 10879.288 1.666e+01 blend 10898.680 1.005e+02 blend 10926.430 3.360e+02 blend 10951.349 1.277e+02 blend 10975.331 3.619e+02 blend 11009.293 1.008e+02 blend 11029.815 2.469e+02 blend 11072.457 5.668e+01 blend 11090.019 1.235e+02 blend 11140.912 2.379e+01 blend 11156.034 4.720e+01 blend 11227.947 1.405e+01 blend 11291.166 1.400e+01 blend 11299.441 4.452e+01 blend 11306.335 2.209e+01 blend 11312.851 1.093e+02 blend 11323.366 4.939e+01 blend 11331.193 1.982e+02 blend 11346.886 7.987e+01 blend 11354.235 2.293e+02 blend 11377.136 8.142e+01 blend 11437.764 6.131e+01 blend 11439.940 5.719e+02 blend 11447.236 1.888e+01 blend 11451.604 2.137e+02 blend 11468.326 7.471e+01 blend 11490.320 2.286e+01 blend 11508.616 1.234e+02 blend 11538.791 4.132e+02 blend 11565.249 1.596e+02 blend 11591.684 4.551e+02 blend 11627.846 1.297e+02 blend 11650.746 3.207e+02 blend 11696.348 7.601e+01 blend 11716.151 1.673e+02 blend 11770.827 3.362e+01 blend 11788.029 6.745e+01 blend 11851.443 1.149e+01 blend 11866.503 2.140e+01 blend 11968.862 1.986e+01 blend 11973.556 1.051e+01 blend 11975.834 5.912e+01 blend 11983.323 2.902e+01 blend 11988.647 1.373e+02 blend 12000.141 6.139e+01 blend 12007.078 2.382e+02 blend 12024.246 9.507e+01 blend 12030.885 2.661e+02 blend 12055.878 9.391e+01 blend 12120.387 6.920e+01 blend 12122.640 6.490e+02 blend 12131.067 2.157e+01 blend 12135.923 2.489e+02 blend 12154.935 9.020e+01 blend 12179.923 2.888e+01 blend 12196.386 1.394e+02 blend 12229.294 4.670e+02 blend 12257.729 1.834e+02 blend 12286.988 5.263e+02 blend 12325.913 1.536e+02 blend 12351.597 3.833e+02 blend 12400.878 9.385e+01 blend 12423.347 2.089e+02 blend 12482.708 4.380e+01 blend 12502.417 8.888e+01 blend 12571.579 1.598e+01 blend 12588.979 3.009e+01 blend 12747.959 2.671e+01 blend 12752.797 7.436e+01 blend 12752.995 1.398e+01 blend 12760.993 3.609e+01 blend 12764.418 1.633e+02 blend 12777.100 7.224e+01 blend 12782.567 2.706e+02 blend 12801.543 1.071e+02 blend 12806.984 2.920e+02 blend 12834.564 1.025e+02 blend 12903.533 7.391e+01 blend 12905.711 6.964e+02 blend 12915.800 2.333e+01 blend 12921.132 2.743e+02 blend 12943.176 1.031e+02 blend 12972.127 3.460e+01 blend 12985.646 1.490e+02 blend 13008.234 1.010e+01 blend 13021.635 4.994e+02 blend 13052.740 1.997e+02 blend 13085.264 5.764e+02 blend 13127.822 1.725e+02 blend 13156.793 4.344e+02 blend 13210.848 1.100e+02 blend 13236.516 2.476e+02 blend 13301.917 5.423e+01 blend 13324.683 1.114e+02 blend 13401.247 2.114e+01 blend 13421.535 4.030e+01 blend 13527.336 1.186e+01 blend 13664.103 3.348e+01 blend 13665.451 8.711e+01 blend 13669.549 1.733e+01 blend 13671.122 1.047e+01 blend 13674.536 4.183e+01 blend 13674.888 1.807e+02 blend 13689.090 7.921e+01 blend 13692.115 2.862e+02 blend 13713.422 1.124e+02 blend 13716.835 2.983e+02 blend 13747.764 1.043e+02 blend 13821.960 7.369e+01 blend 13823.761 6.967e+02 blend 13836.390 2.356e+01 blend 13842.113 2.821e+02 blend 13860.266 1.025e+01 blend 13868.320 1.101e+02 blend 13902.718 3.878e+01 blend 13911.548 1.489e+02 blend 13945.629 1.201e+01 blend 13951.010 4.988e+02 blend 13985.895 2.035e+02 blend 14007.896 2.868e+01 blend 14018.044 1.597e+01 blend 14022.226 5.906e+02 blend 14044.573 1.186e+02 blend 14058.865 6.137e+01 blend 14069.797 1.815e+02 blend 14086.711 3.630e+02 blend 14102.697 4.615e+02 blend 14107.007 1.710e+02 blend 14134.002 7.872e+02 blend 14162.960 3.295e+02 blend 14163.235 1.211e+02 blend 14186.057 1.045e+03 blend 14192.812 2.756e+02 blend 14227.201 3.823e+02 blend 14266.356 6.322e+01 blend 14292.924 1.314e+02 blend 14342.005 3.163e+02 blend 14344.442 2.877e+03 blend 14352.271 9.237e+01 blend 14356.719 9.728e+02 blend 14369.083 3.375e+01 blend 14374.414 2.963e+02 blend 14379.438 2.641e+01 blend 14392.188 1.079e+01 blend 14397.753 7.599e+01 blend 14403.382 5.097e+01 blend 14426.905 1.598e+01 blend 14469.109 6.416e+02 blend 14518.961 2.138e+03 blend 14524.566 1.626e+01 blend 14563.983 7.779e+02 blend 14604.833 2.166e+03 blend 14665.068 5.650e+02 blend 14670.644 1.138e+01 blend 14698.437 1.349e+03 blend 14702.242 5.811e+01 blend 14713.306 3.210e+01 blend 14740.015 2.260e+02 blend 14755.589 1.159e+02 blend 14772.383 2.823e+02 blend 14783.736 6.571e+02 blend 14799.832 5.974e+02 blend 14805.789 3.069e+02 blend 14833.093 1.367e+03 blend 14864.397 5.680e+02 blend 14886.165 1.018e+02 blend 14887.699 1.759e+03 blend 14909.027 1.961e+02 blend 14931.883 6.400e+02 blend 15006.737 2.715e+01 blend 15026.056 4.861e+01 blend 15052.866 5.187e+02 blend 15055.550 4.751e+03 blend 15063.998 1.533e+02 blend 15068.968 1.646e+03 blend 15082.254 5.734e+01 blend 15088.276 5.183e+02 blend 15107.382 1.902e+01 blend 15113.725 1.387e+02 blend 15145.498 3.073e+01 blend 15187.140 1.054e+03 blend 15240.954 3.521e+03 blend 15287.789 1.301e+03 blend 15332.403 3.645e+03 blend 15395.335 9.728e+02 blend 15430.163 1.614e+01 blend 15432.156 2.343e+03 blend 15462.125 7.674e+01 blend 15474.212 4.203e+01 blend 15500.864 2.809e+02 blend 15509.769 5.063e+02 blend 15517.873 1.428e+02 blend 15540.328 1.082e+03 blend 15546.141 7.763e+02 blend 15570.159 3.595e+02 blend 15597.631 1.551e+03 blend 15630.972 1.922e+02 solo 15631.561 6.395e+02 blend 15631.677 1.922e+02 solo 15654.953 1.934e+03 blend 15656.963 3.739e+02 blend 15702.539 7.003e+02 blend 15760.328 5.454e+01 blend 15782.127 9.854e+01 blend 15830.335 5.574e+02 blend 15833.272 5.138e+03 blend 15842.504 1.667e+02 blend 15848.061 1.825e+03 blend 15862.489 6.387e+01 blend 15869.307 5.944e+02 blend 15890.034 2.198e+01 blend 15896.477 1.174e+01 solo 15897.288 1.661e+02 blend 15897.794 1.174e+01 solo 15915.922 2.001e+01 blend 15932.211 3.879e+01 blend 15972.596 1.136e+03 blend 16030.832 3.806e+03 blend 16079.753 1.429e+03 blend 16128.609 4.033e+03 blend 16194.615 1.102e+03 blend 16235.376 2.679e+03 blend 16270.319 1.922e+01 blend 16279.727 1.108e+01 blend 16302.279 8.526e+01 blend 16315.516 4.629e+01 blend 16317.162 5.978e+02 blend 16341.755 2.940e+02 blend 16351.302 1.291e+03 blend 16360.386 1.482e+02 blend 16388.492 7.731e+02 blend 16414.737 3.550e+02 blend 16442.156 1.484e+03 blend 16447.616 2.393e+02 blend 16476.483 4.703e+02 blend 16479.061 6.076e+02 blend 16502.365 1.796e+03 blend 16553.815 6.473e+02 blend 16586.323 7.235e+01 blend 16611.023 1.326e+02 blend 16689.201 5.062e+02 blend 16692.380 4.696e+03 blend 16702.639 1.532e+02 blend 16708.852 1.709e+03 blend 16724.739 6.009e+01 blend 16732.480 5.758e+02 blend 16733.660 1.677e+01 blend 16753.832 2.885e+01 solo 16755.245 2.145e+01 blend 16756.299 2.885e+01 solo 16763.573 1.679e+02 blend 16802.368 4.132e+01 blend 16840.482 1.035e+03 blend 16903.679 3.479e+03 blend 16955.078 1.327e+03 blend 17008.757 3.773e+03 blend 17078.370 1.054e+03 blend 17123.659 2.590e+03 blend 17210.319 5.965e+02 blend 17211.664 2.022e+01 blend 17221.991 1.156e+01 blend 17243.039 8.379e+01 blend 17248.623 1.302e+03 blend 17257.607 4.511e+01 blend 17282.868 2.726e+02 blend 17303.370 1.362e+02 blend 17330.869 6.828e+02 blend 17351.152 2.516e+02 blend 17359.686 3.110e+02 blend 17383.806 4.998e+02 blend 17386.696 1.261e+03 blend 17427.045 5.127e+02 blend 17449.967 1.482e+03 blend 17501.229 8.102e+01 blend 17505.897 5.319e+02 blend 17529.364 1.494e+02 blend 17649.854 4.095e+02 blend 17653.222 3.821e+03 blend 17660.965 2.021e+01 blend 17664.881 1.254e+02 blend 17671.812 1.425e+03 blend 17685.493 3.512e+01 blend 17689.636 5.032e+01 blend 17698.442 4.967e+02 blend 17723.861 1.861e+01 blend 17733.455 1.512e+02 blend 17777.130 3.921e+01 blend 17811.475 8.417e+02 blend 17880.298 2.837e+03 blend 17934.744 1.100e+03 blend 17993.962 3.152e+03 blend 18067.935 9.016e+02 blend 18118.494 2.237e+03 blend 18211.014 5.320e+02 blend 18254.214 1.174e+03 blend 18283.469 1.912e+01 blend 18294.806 1.084e+01 blend 18313.307 7.418e+01 blend 18329.390 3.961e+01 blend 18352.825 2.281e+02 blend 18364.214 2.367e+02 blend 18375.503 1.131e+02 blend 18400.404 4.755e+02 solo 18401.707 5.451e+02 blend 18402.314 4.755e+02 solo 18433.546 2.465e+02 blend 18459.584 9.697e+02 blend 18504.005 3.921e+02 blend 18526.067 1.108e+03 blend 18527.923 8.123e+01 blend 18560.160 1.514e+02 blend 18587.329 3.968e+02 blend 18702.613 2.183e+01 blend 18730.882 3.831e+01 blend 18741.117 3.013e+02 blend 18744.540 2.827e+03 blend 18758.194 9.334e+01 blend 18765.882 1.081e+03 blend 18786.374 3.832e+01 blend 18796.412 3.897e+02 blend 18825.399 1.468e+01 blend 18836.520 1.239e+02 blend 18886.546 3.387e+01 blend 18914.833 6.235e+02 blend 18990.082 2.109e+03 blend 19048.434 8.316e+02 blend 19114.085 2.403e+03 blend 19193.537 7.041e+02 blend 19250.306 1.765e+03 blend 19350.119 4.339e+02 blend 19399.176 9.687e+02 blend 19518.440 2.038e+02 blend 19528.615 1.602e+01 blend 19555.347 5.839e+01 blend 19561.033 4.144e+02 blend 19573.219 3.097e+01 blend 19593.420 1.702e+02 blend 19618.724 8.381e+01 blend 19642.467 3.890e+02 blend 19677.998 1.750e+02 blend 19698.938 7.464e+01 blend 19702.083 6.682e+02 blend 19736.210 1.408e+02 blend 19751.515 2.693e+02 blend 19771.862 7.442e+02 blend 19839.728 2.665e+02 blend 19892.161 2.163e+01 blend 19925.083 3.839e+01 blend 20005.015 2.002e+02 blend 20008.163 1.887e+03 blend 20024.830 6.277e+01 blend 20033.211 7.391e+02 blend 20057.585 2.636e+01 blend 20068.995 2.762e+02 blend 20103.037 1.046e+01 blend 20115.975 9.178e+01 blend 20174.565 2.646e+01 blend 20193.227 4.186e+02 blend 20275.840 1.422e+03 blend 20339.497 5.712e+02 blend 20412.680 1.664e+03 blend 20499.364 5.005e+02 blend 20563.548 1.269e+03 blend 20672.844 3.228e+02 blend 20729.014 7.297e+02 blend 20860.246 1.604e+02 blend 20909.569 3.304e+02 blend 21012.298 1.149e+01 blend 21033.264 3.963e+01 blend 21053.424 2.094e+01 blend 21062.093 6.287e+01 blend 21067.935 1.101e+02 blend 21096.603 5.406e+01 blend 21105.690 1.201e+02 blend 21115.857 2.420e+02 blend 21156.117 1.086e+02 blend 21176.557 4.031e+02 blend 21232.424 1.625e+02 blend 21249.592 4.391e+02 blend 21279.056 1.971e+01 blend 21317.916 3.539e+01 blend 21325.974 1.579e+02 blend 21505.044 1.181e+02 blend 21507.308 1.116e+03 blend 21528.663 3.747e+01 blend 21537.522 4.492e+02 blend 21567.779 1.609e+01 blend 21580.643 1.738e+02 blend 21637.230 6.040e+01 blend 21707.826 1.839e+01 blend 21711.170 2.508e+02 blend 21802.312 8.558e+02 blend 21873.518 3.513e+02 blend 21955.638 1.033e+03 blend 22052.366 3.197e+02 blend 22125.518 8.202e+02 blend 22247.809 2.166e+02 blend 22312.725 4.961e+02 blend 22460.264 1.143e+02 blend 22517.969 2.387e+02 blend 22690.402 4.813e+01 blend 22741.965 9.316e+01 blend 22939.096 1.638e+01 blend 22985.505 2.980e+01 blend