SIMPLE = T / Tape is in Fits format BITPIX = 32 / Bits per pixel NAXIS = 2 / Number of axes NAXIS1 = 1024 / Number of pixels in axis 1 NAXIS2 = 1024 / Number of pixels in axis 2 BSCALE = 1.00000 / Scaling factor BZERO = 0.00000 / Scaling zero-point OUTDIR = '/sdata903/nirc2eng/2009oct01/ ' / Original directory ROOTNAME= 'n ' / File prefix FRAMENO = 17 / Frame number FILENAME= 'n0017.fits ' / Original File name TELESCOP= 'Keck II ' / Telescope OBSERVER= 'Djorgovski ' / Observer OBJECT = 'mars 14:30 ' / Object name COMMENT = ' ' / Comment ITIME = 0.181 / Integration time per coadd EXPSTART= '14:31:28.157 ' / Exposure start time (UT) EXPSTOP = '14:31:29.183 ' / Exposure stop time (UT) COADDS = 1 / Number of coadds SAMPMODE= 2 / 1=Single; 2=CDS; 3=MCDS DETBIAS = 450 / Detector bias setting (0-4096) MULTISAM= 16 / Number of multiple reads Q1OFFSET= 3172 / Aladdin Quadrant 1 preamp offset Q2OFFSET= 3183 / Aladdin Quadrant 2 preamp offset Q3OFFSET= 3180 / Aladdin Quadrant 3 preamp offset Q4OFFSET= 3183 / Aladdin Quadrant 4 preamp offset GAIN = 4 / Detector Gain Setting PREOFF = 400 / Preamp Offset Voltage SAMPRATE= 200 / Pixel rate in kps IMAGETYP= 'data ' / SLITMM = 1.22911 / SLITNAME= 'none ' / SLITTILT= 0.00000 / CAMDIST = 260.60501 / camera slider's distance from CAMNAME = 'narrow ' / camera slider's named position CAMRAW = 260605 / camera slider's encoder positi CENWAVE = 2.12450 / central wavelength of passband MINWAVE = 1.94900 / minimum wavelength of passband MAXWAVE = 2.30000 / maximum wavelength of passband EFFWAVE = 2.12450 / effective wavelength of passba FWIANGL = 129.20041 / inner filter wheel's angular p FWINAME = 'Kp ' / inner filter wheel's named pos FWINUM = 7 / FWIRAW = 135889 / inner filter wheel's encoder p FWOANGL = 329.19842 / outer filter wheel's angular p FWONAME = 'clear ' / outer filter wheel's named pos FWONUM = 17 / FWORAW = 191444 / outer filter wheel's encoder p FILTER = 'Kp + clear ' / composite filter name (both wh GRSDIST = 132.04849 / grism slider's distance from h GRSNAME = 'clear ' / grism slider's named position GRSRAW = 264097 / grism slider's encoder positio PMSANGL = 296.69397 / pupil wheel's angular position PMSNAME = 'largehex ' / pupil wheel's named position PMSRAW = 182415 / pupil wheel's encoder position PMRANGL = 103.31549 / pupil drive's angular position PSIDIST = 4.51793 / Inner preslit's distance from PSINAME = 'mfov_center ' / Inner preslit's named position PSIRAW = 34517 / Inner preslit's encoder positi PSODIST = 4.46963 / Outer preslit's distance from PSONAME = 'nfov_center ' / Outer preslit's named position PSORAW = 34148 / Outer preslit's encoder positi SHRDIST = 0.03600 / Shutter's distance from home ( SHRNAME = 'open ' / Shutter's named position SHRRAW = 72 / shutter's encoder position SLSDIST = 254.36150 / slit slide's distance from hom SLSNAME = 'clear ' / slit slide's named position SLSRAW = 508723 / slit slide's encoder position SLMDIST = 179.93750 / slit mask's distance from home SLMNAME = 'narrow_clear ' / slit mask's named position SLMRAW = 359875 / slit mask's encoder position AODELAY = 0 / Delay after AO locks UTC = '14:31:28.40 ' / coordinated universal time (h) AIRMASS = 1.27263 / air mass (1.27) AXESTAT = 'tracking ' / axes control status AZ = 78.63586 / telescope azimuth (78.64 deg) CALOCAL = 0.01439 / collimation azimuth local (51. CELOCAL = -0.01524 / collimation elevation local (- CURRINST= 'NIRC2 ' / current instrument DATE-OBS= '2009-10-01 ' / universal date of observation DCSSTAT = 'standby ' / drive and control status DEC = 22.42094 / telescope declination (+22:25: DECOFF = 0.00000 / declination offset (0.0 arcsec DOMEPOSN= 78.61500 / dome azimuth (78.61 deg) DOMESTAT= 'tracking ' / dome status EL = 51.75059 / telescope elevation (51.75 deg EQUINOX = 2000.00000 / telescope equinox (2000.0) FOCALSTN= 'lnas (left nasmyth)' / focal station GUIDWAVE= '0.630 ' / guidestar wavelength (microns) HA = -41.10703 / telescope hour angle (+21:15:3 INSTANGL= 0.70000 / porg to instrument angle (0.7 INSTFLIP= 'no ' / porg to instrument y flip LST = '04:51:24.58 ' / local apparent sidereal time ( MJD-OBS = 55105.60519 / modified julian date of observ PARANG = -86.03442 / parallactic angle astrometric PARANTEL= -86.02808 / parallactic angle telescope (- DRA = 0.00000 / diff ra rate (0.000000 seconds DDEC = 0.00000 / diff decl rate (0.0000000 arcs DTRACK = 'disabled ' / differential tracking enabled RA = 113.81079 / telescope right ascension (07: RAOFF = 0.00000 / right ascension offset (0.0 ar ROTCALAN= 0.00000 / rotator calibration angle (0.0 ROTMODE = 'position angle ' / rotator tracking mode ROTPDEST= -221.52141 / rotator physical destination ( ROTPPOSN= -221.53301 / rotator physical position (-22 ROTDEST = 0.70000 / rotator user destination (0.70 ROTPOSN = 0.70000 / rotator user position (0.70 de ROTREFAN= 0.00000 / rotator reference angle (0.00 SECFOCUS= 0.00085 / secondary mirror focus raw (0. SECTHETX= '-98.8 ' / secondary mirror thetax (arcse SECTHETY= '-240.9 ' / secondary mirror thetay (arcse TARGNAME= 'mars 14:30 ' / target name TARGWAVE= '2.124 ' / target wavelength (microns) TELESCOP= 'Keck II ' / telescope name TELFOCUS= 0.00106 / telescope focus compensated (1 TUBETEMP= 0.81410 / tube temperature (0.81 degC) AOOPSMOD= '0 ' / AO General Ops Mode FITS AODMSTAT= 'open ' / AO deformable mirror loop stat AODTSTAT= 'open ' / AO downlink tip/tilt loop stat AOTTMODE= 'closed ' / AO tip/tilt offloading mode AOAOAMED= '41362 ' / AO WFC AOA camera median light AOLBFWHM= '2.163931 ' / AO LBWFS avg fwhm WSFRRT = '1400 ' / Frame rate for WFS cam (Hz) DMGAIN = '0.500 ' / Set DM loop gain DMMRFN = '1Oct0003.mr ' / Name of DM reconstructor file DTGAIN = '0.300 ' / Set TT loop gain AOWFC0 = '-1.989000 ' / AO WFS focus stage FSM coeffic AOFCNGFO= '-0.001983 ' / AO FC NGS Focus Calc Value (m) AOFCLGFO= '0.198827 ' / AO FC LGS pregain focus calc v AOFCLBFO= '0.000000 ' / AO FC LBWFS pregain focus calc AOFCNGCT= 'ON ' / AO FC NGS control AOFCLGCT= 'OFF ' / AO FC LGS control AOFCLBCT= 'OFF ' / AO FC LBWFS control AOFCSALT= '88000 ' / AO FC sodium alt preset (m) AOFOMODE= 'closed ' / AO focus offloading mode AOTSDAR = 'false ' / AO TSS_USE_DAR? AODRDTEN= '0.0 ' / AO DAR DTT CTRLOFF ENABLE AODRENA = '1.0 ' / AO DAR_ENABLE/DISABLE AOTSZ = '38.613 ' / AO tip/tilt sensor stage Z pos AOTSX = '-1.371 ' / AO tip/tilt sensor stage X pos AOTSY = '4.046 ' / AO tip/tilt sensor stage Y pos OBTSNAME= 'noName ' / Named position control for TSS OBTSX = '-3.85 ' / User value of TSS x axis (mm) OBTSY = '31.36 ' / User value of TSS y axis (mm) OBTSZ = '38.61 ' / User value of TSS z axis (mm) AOLPMOVE= 'false ' / AO LSP MOVE ENABLE LGRMSWF = '300.0 ' / LGSAO RMS WF Residual LSAMPPWR= '0.000000 ' / Amp Power (watts) LSPROP = 'no ' / Laser Propagating AOFMX = '-0.88 ' / AO field steering mirrors X po AOFMY = '3.32 ' / AO field steering mirrors Y po OBFMXIM = '3.320 ' / Image plane x motion for FSM ( OBFMYIM = '-0.880 ' / Image plane y motion for FSM ( OBFMXPU = '0.00 ' / Pupil plane x motion for FSM ( OBFMYPU = '0.00 ' / Pupil plane y motion for FSM ( OBFMDREN= '0.000000 ' / FSM Coordinated move use dar o OBFSNAME= '2.4 ' / Named position control for FSS OBIMNAME= 'out ' / Named position control for ISM OBLBNAME= 'noName ' / Named position control for LBS OBAMNAME= 'mirror ' / Named position control for AFM OBRT = '-110.7635 ' / User value of ROT (deg) OBSDNAME= 'beamSplitter ' / Named position control for SOD OBSFX = '-119.00 ' / User value of SFP x axis (mm) OBSFY = '-0.00 ' / User value of SFP y axis (mm) OBSFZ = '0.00 ' / User value of SFP z axis (mm) OBSI = '-1.50 ' / User value of SFD (mm) OBSFNAME= 'telescope ' / Named position control for SFP OBSNNAME= 'block ' / Named position control for SND OBWCNAME= '2.4 ' / Named position control for WCS OBWFSTST= 'INPOS ' / State of FCS as string OBWLNAME= '2.4 ' / Named position control for WLS OBWPNAME= 'ngs ' / Named position control for WPS OBWNNAME= 'open ' / Named position control for WND OBSWSTA = 'off ' / White light power status OBSWNAME= 'BLOCK ' / Named position control for SFW OBWF = '-1.988 ' / User value of FCS (mm) WSSMPRG = '2 ' / WFS_SciMeas program (0) WSSMREP = '216 ' / WFS SciMeas repetitions (incre WSSMGN = '1 ' / WFS gain (0) WSCNORFN= '24NIRC2-N2x2.cog ' / Name of origin vec file WCDTSTAT= 'OPEN ' / Status of down tt loop WCDMSTAT= 'OPEN ' / Status of DM loop WCUTSTAT= 'OPEN ' / Status of utt loop DTCLP = 'CLOSE ' / OPEN/CLOSE TT CLMP ctrl loop UTCLP = 'OPEN ' / OPEN/CLOSE TT CLMP ctrl loop UTGAIN = '0.000 ' / Set TT loop gain END