Minimum Integration Time for NIRC2 Subarrays
The table below shows the minimum integration time available for CDS mode readout of various subarrays on NIRC2. It assumes a samprate of 250 kHz. Horizontally are listed the sizes in X, and vertically we have sizes in Y. A hyphen indicates that the subarray is not legal. A number gives the minimum integration time in millisec.
|
N(x), number of columns |
32 |
64 |
96 |
128 |
160 |
192 |
224 |
256 |
288 |
320 |
352 |
384 |
416 |
448 |
480 |
512 |
544 |
576 |
608 |
640 |
672 |
704 |
736 |
768 |
800 |
832 |
864 |
896 |
928 |
960 |
992 |
1024 |
N(y) |
8 |
- |
- |
- |
- |
- |
- |
- |
2.5 |
- |
- |
- |
- |
- |
- |
- |
2.5 |
- |
- |
- |
- |
- |
- |
- |
2.5 |
- |
- |
- |
- |
- |
- |
- |
2.56 |
16 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
2.5 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
3.67 |
24 |
- |
- |
- |
2.5 |
- |
- |
- |
2.5 |
- |
- |
- |
2.5 |
- |
- |
- |
2.96 |
- |
- |
- |
3.41 |
- |
- |
- |
3.87 |
- |
- |
- |
4.33 |
- |
- |
- |
4.78 |
32 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
3.61 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
5.9 |
40 |
- |
- |
- |
- |
- |
- |
- |
2.9 |
- |
- |
- |
- |
- |
- |
- |
4.27 |
- |
- |
- |
- |
- |
- |
- |
5.64 |
- |
- |
- |
- |
- |
- |
- |
7.01 |
48 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
4.92 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
8.12 |
56 |
- |
2.5 |
- |
2.84 |
- |
3.3 |
- |
3.75 |
- |
4.21 |
- |
4.67 |
- |
5.12 |
- |
5.58 |
- |
6.04 |
- |
6.5 |
- |
6.95 |
- |
7.41 |
- |
7.87 |
- |
8.32 |
- |
8.78 |
- |
9.24 |
64 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
6.24 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
10.35 |
72 |
- |
- |
- |
- |
- |
- |
- |
4.61 |
- |
- |
- |
- |
- |
- |
- |
6.89 |
- |
- |
- |
- |
- |
- |
- |
9.18 |
- |
- |
- |
- |
- |
- |
- |
11.46 |
80 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
7.55 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
12.58 |
88 |
- |
- |
- |
4.1 |
- |
- |
- |
5.47 |
- |
- |
- |
6.84 |
- |
- |
- |
8.21 |
- |
- |
- |
9.58 |
- |
- |
- |
10.95 |
- |
- |
- |
12.32 |
- |
- |
- |
13.69 |
96 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
8.86 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
14.8 |
104 |
- |
- |
- |
- |
- |
- |
- |
6.32 |
- |
- |
- |
- |
- |
- |
- |
9.52 |
- |
- |
- |
- |
- |
- |
- |
12.72 |
- |
- |
- |
- |
- |
- |
- |
15.92 |
112 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
10.18 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
17.03 |
120 |
3.98 |
4.44 |
4.89 |
5.35 |
5.81 |
6.26 |
6.72 |
7.18 |
7.64 |
8.09 |
8.55 |
9.01 |
9.46 |
9.92 |
10.38 |
10.83 |
11.29 |
11.75 |
12.2 |
12.66 |
13.12 |
13.58 |
14.03 |
14.49 |
14.95 |
15.4 |
15.86 |
16.32 |
16.77 |
17.23 |
17.69 |
18.15 |
128 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
11.49 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
19.26 |
136 |
- |
- |
- |
- |
- |
- |
- |
8.03 |
- |
- |
- |
- |
- |
- |
- |
12.15 |
- |
- |
- |
- |
- |
- |
- |
16.26 |
- |
- |
- |
- |
- |
- |
- |
20.37 |
144 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
12.8 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
21.49 |
152 |
- |
- |
- |
6.61 |
- |
- |
- |
8.89 |
- |
- |
- |
11.18 |
- |
- |
- |
13.46 |
- |
- |
- |
15.74 |
- |
- |
- |
18.03 |
- |
- |
- |
20.31 |
- |
- |
- |
22.6 |
160 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
14.12 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
23.71 |
168 |
- |
- |
- |
- |
- |
- |
- |
9.75 |
- |
- |
- |
- |
- |
- |
- |
14.77 |
- |
- |
- |
- |
- |
- |
- |
19.8 |
- |
- |
- |
- |
- |
- |
- |
24.83 |
176 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
15.43 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
25.94 |
184 |
- |
6.49 |
- |
7.86 |
- |
9.23 |
- |
10.6 |
- |
11.97 |
- |
13.34 |
- |
14.72 |
- |
16.09 |
- |
17.46 |
- |
18.83 |
- |
20.2 |
- |
21.57 |
- |
22.94 |
- |
24.31 |
- |
25.68 |
- |
27.05 |
192 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
16.74 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
28.17 |
200 |
- |
- |
- |
- |
- |
- |
- |
11.46 |
- |
- |
- |
- |
- |
- |
- |
17.4 |
- |
- |
- |
- |
- |
- |
- |
23.34 |
- |
- |
- |
- |
- |
- |
- |
29.28 |
208 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
18.06 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
30.39 |
216 |
- |
- |
- |
9.12 |
- |
- |
- |
12.31 |
- |
- |
- |
15.51 |
- |
- |
- |
18.71 |
- |
- |
- |
21.91 |
- |
- |
- |
25.11 |
- |
- |
- |
28.31 |
- |
- |
- |
31.51 |
224 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
19.37 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
32.62 |
232 |
- |
- |
- |
- |
- |
- |
- |
13.17 |
- |
- |
- |
- |
- |
- |
- |
20.03 |
- |
- |
- |
- |
- |
- |
- |
26.88 |
- |
- |
- |
- |
- |
- |
- |
33.73 |
240 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
20.68 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
34.85 |
248 |
7.63 |
8.54 |
9.46 |
10.37 |
11.29 |
12.2 |
13.11 |
14.03 |
14.94 |
15.86 |
16.77 |
17.68 |
18.6 |
19.51 |
20.42 |
21.34 |
22.25 |
23.17 |
24.08 |
24.99 |
25.91 |
26.82 |
27.74 |
28.65 |
29.56 |
30.48 |
31.39 |
32.31 |
33.22 |
34.13 |
35.05 |
35.96 |
256 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
22 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
37.07 |
264 |
- |
- |
- |
- |
- |
- |
- |
14.88 |
- |
- |
- |
- |
- |
- |
- |
22.65 |
- |
- |
- |
- |
- |
- |
- |
30.42 |
- |
- |
- |
- |
- |
- |
- |
38.19 |
272 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
23.31 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
39.3 |
280 |
- |
- |
- |
11.63 |
- |
- |
- |
15.74 |
- |
- |
- |
19.85 |
- |
- |
- |
23.96 |
- |
- |
- |
28.08 |
- |
- |
- |
32.19 |
- |
- |
- |
36.3 |
- |
- |
- |
40.42 |
288 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
24.62 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
41.53 |
296 |
- |
- |
- |
- |
- |
- |
- |
16.6 |
- |
- |
- |
- |
- |
- |
- |
25.28 |
- |
- |
- |
- |
- |
- |
- |
33.96 |
- |
- |
- |
- |
- |
- |
- |
42.64 |
304 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
25.93 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
43.76 |
312 |
- |
10.6 |
- |
12.88 |
- |
15.17 |
- |
17.45 |
- |
19.74 |
- |
22.02 |
- |
24.31 |
- |
26.59 |
- |
28.88 |
- |
31.16 |
- |
33.45 |
- |
35.73 |
- |
38.01 |
- |
40.3 |
- |
42.58 |
- |
44.87 |
320 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
27.25 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
45.98 |
328 |
- |
- |
- |
- |
- |
- |
- |
18.31 |
- |
- |
- |
- |
- |
- |
- |
27.9 |
- |
- |
- |
- |
- |
- |
- |
37.5 |
- |
- |
- |
- |
- |
- |
- |
47.1 |
336 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
28.56 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
48.21 |
344 |
- |
- |
- |
14.14 |
- |
- |
- |
19.16 |
- |
- |
- |
24.19 |
- |
- |
- |
29.22 |
- |
- |
- |
34.24 |
- |
- |
- |
39.27 |
- |
- |
- |
44.3 |
- |
- |
- |
49.32 |
352 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
29.87 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
50.44 |
360 |
- |
- |
- |
- |
- |
- |
- |
20.02 |
- |
- |
- |
- |
- |
- |
- |
30.53 |
- |
- |
- |
- |
- |
- |
- |
41.04 |
- |
- |
- |
- |
- |
- |
- |
51.55 |
368 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31.19 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
52.66 |
376 |
11.28 |
12.65 |
14.02 |
15.39 |
16.76 |
18.13 |
19.51 |
20.88 |
22.25 |
23.62 |
24.99 |
26.36 |
27.73 |
29.1 |
30.47 |
31.84 |
33.21 |
34.59 |
35.96 |
37.33 |
38.7 |
40.07 |
41.44 |
42.81 |
44.18 |
45.55 |
46.92 |
48.29 |
49.66 |
51.04 |
52.41 |
53.78 |
384 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
32.5 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
54.89 |
392 |
- |
- |
- |
- |
- |
- |
- |
21.73 |
- |
- |
- |
- |
- |
- |
- |
33.16 |
- |
- |
- |
- |
- |
- |
- |
44.58 |
- |
- |
- |
- |
- |
- |
- |
56 |
400 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
33.81 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
57.12 |
408 |
- |
- |
- |
16.65 |
- |
- |
- |
22.59 |
- |
- |
- |
28.53 |
- |
- |
- |
34.47 |
- |
- |
- |
40.41 |
- |
- |
- |
46.35 |
- |
- |
- |
52.29 |
- |
- |
- |
58.23 |
416 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
35.13 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
59.34 |
424 |
- |
- |
- |
- |
- |
- |
- |
23.44 |
- |
- |
- |
- |
- |
- |
- |
35.78 |
- |
- |
- |
- |
- |
- |
- |
48.12 |
- |
- |
- |
- |
- |
- |
- |
60.46 |
432 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
36.44 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
61.57 |
440 |
- |
14.7 |
- |
17.9 |
- |
21.1 |
- |
24.3 |
- |
27.5 |
- |
30.7 |
- |
33.9 |
- |
37.1 |
- |
40.29 |
- |
43.49 |
- |
46.69 |
- |
49.89 |
- |
53.09 |
- |
56.29 |
- |
59.49 |
- |
62.69 |
448 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
37.75 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
63.8 |
456 |
- |
- |
- |
- |
- |
- |
- |
25.16 |
- |
- |
- |
- |
- |
- |
- |
38.41 |
- |
- |
- |
- |
- |
- |
- |
51.66 |
- |
- |
- |
- |
- |
- |
- |
64.91 |
464 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
39.07 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
66.03 |
472 |
- |
- |
- |
19.16 |
- |
- |
- |
26.01 |
- |
- |
- |
32.87 |
- |
- |
- |
39.72 |
- |
- |
- |
46.58 |
- |
- |
- |
53.43 |
- |
- |
- |
60.28 |
- |
- |
- |
67.14 |
480 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
40.38 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
68.25 |
488 |
- |
- |
- |
- |
- |
- |
- |
26.87 |
- |
- |
- |
- |
- |
- |
- |
41.03 |
- |
- |
- |
- |
- |
- |
- |
55.2 |
- |
- |
- |
- |
- |
- |
- |
69.37 |
496 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
41.69 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
70.48 |
504 |
14.93 |
16.76 |
18.59 |
20.41 |
22.24 |
24.07 |
25.9 |
27.73 |
29.55 |
31.38 |
33.21 |
35.04 |
36.86 |
38.69 |
40.52 |
42.35 |
44.18 |
46 |
47.83 |
49.66 |
51.49 |
53.32 |
55.14 |
56.97 |
58.8 |
60.63 |
62.45 |
64.28 |
66.11 |
67.94 |
69.77 |
71.59 |
512 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
43 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
72.71 |
520 |
- |
- |
- |
- |
- |
- |
- |
28.58 |
- |
- |
- |
- |
- |
- |
- |
43.66 |
- |
- |
- |
- |
- |
- |
- |
58.74 |
- |
- |
- |
- |
- |
- |
- |
73.82 |
528 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
44.32 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
74.93 |
536 |
- |
- |
- |
21.67 |
- |
- |
- |
29.44 |
- |
- |
- |
37.21 |
- |
- |
- |
44.97 |
- |
- |
- |
52.74 |
- |
- |
- |
60.51 |
- |
- |
- |
68.28 |
- |
- |
- |
76.05 |
544 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
45.63 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
77.16 |
552 |
- |
- |
- |
- |
- |
- |
- |
30.29 |
- |
- |
- |
- |
- |
- |
- |
46.29 |
- |
- |
- |
- |
- |
- |
- |
62.28 |
- |
- |
- |
- |
- |
- |
- |
78.27 |
560 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
46.94 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
79.39 |
568 |
- |
18.81 |
- |
22.92 |
- |
27.04 |
- |
31.15 |
- |
35.26 |
- |
39.38 |
- |
43.49 |
- |
47.6 |
- |
51.71 |
- |
55.83 |
- |
59.94 |
- |
64.05 |
- |
68.16 |
- |
72.28 |
- |
76.39 |
- |
80.5 |
576 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
48.26 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
81.61 |
584 |
- |
- |
- |
- |
- |
- |
- |
32.01 |
- |
- |
- |
- |
- |
- |
- |
48.91 |
- |
- |
- |
- |
- |
- |
- |
65.82 |
- |
- |
- |
- |
- |
- |
- |
82.73 |
592 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
49.57 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
83.84 |
600 |
- |
- |
- |
24.18 |
- |
- |
- |
32.86 |
- |
- |
- |
41.54 |
- |
- |
- |
50.23 |
- |
- |
- |
58.91 |
- |
- |
- |
67.59 |
- |
- |
- |
76.27 |
- |
- |
- |
84.96 |
608 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
50.88 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
86.07 |
616 |
- |
- |
- |
- |
- |
- |
- |
33.72 |
- |
- |
- |
- |
- |
- |
- |
51.54 |
- |
- |
- |
- |
- |
- |
- |
69.36 |
- |
- |
- |
- |
- |
- |
- |
87.18 |
624 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
52.2 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
88.3 |
632 |
18.58 |
20.87 |
23.15 |
25.44 |
27.72 |
30 |
32.29 |
34.57 |
36.86 |
39.14 |
41.43 |
43.71 |
46 |
48.28 |
50.57 |
52.85 |
55.14 |
57.42 |
59.71 |
61.99 |
64.28 |
66.56 |
68.85 |
71.13 |
73.42 |
75.7 |
77.99 |
80.27 |
82.56 |
84.84 |
87.12 |
89.41 |
640 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
53.51 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
90.52 |
648 |
- |
- |
- |
- |
- |
- |
- |
35.43 |
- |
- |
- |
- |
- |
- |
- |
54.17 |
- |
- |
- |
- |
- |
- |
- |
72.9 |
- |
- |
- |
- |
- |
- |
- |
91.64 |
656 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
54.82 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
92.75 |
664 |
- |
- |
- |
26.69 |
- |
- |
- |
36.29 |
- |
- |
- |
45.88 |
- |
- |
- |
55.48 |
- |
- |
- |
65.08 |
- |
- |
- |
74.67 |
- |
- |
- |
84.27 |
- |
- |
- |
93.86 |
672 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
56.14 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
94.98 |
680 |
- |
- |
- |
- |
- |
- |
- |
37.14 |
- |
- |
- |
- |
- |
- |
- |
56.79 |
- |
- |
- |
- |
- |
- |
- |
76.44 |
- |
- |
- |
- |
- |
- |
- |
96.09 |
688 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
57.45 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
97.2 |
696 |
- |
22.92 |
- |
27.95 |
- |
32.97 |
- |
38 |
- |
43.03 |
- |
48.05 |
- |
53.08 |
- |
58.11 |
- |
63.13 |
- |
68.16 |
- |
73.18 |
- |
78.21 |
- |
83.24 |
- |
88.26 |
- |
93.29 |
- |
98.32 |
704 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
58.76 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
99.43 |
712 |
- |
- |
- |
- |
- |
- |
- |
38.85 |
- |
- |
- |
- |
- |
- |
- |
59.42 |
- |
- |
- |
- |
- |
- |
- |
79.98 |
- |
- |
- |
- |
- |
- |
- |
100.54 |
720 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
60.07 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
101.66 |
728 |
- |
- |
- |
29.2 |
- |
- |
- |
39.71 |
- |
- |
- |
50.22 |
- |
- |
- |
60.73 |
- |
- |
- |
71.24 |
- |
- |
- |
81.75 |
- |
- |
- |
92.26 |
- |
- |
- |
102.77 |
736 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
61.39 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
103.89 |
744 |
- |
- |
- |
- |
- |
- |
- |
40.57 |
- |
- |
- |
- |
- |
- |
- |
62.04 |
- |
- |
- |
- |
- |
- |
- |
83.52 |
- |
- |
- |
- |
- |
- |
- |
105 |
752 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
62.7 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
106.11 |
760 |
22.23 |
24.97 |
27.71 |
30.46 |
33.2 |
35.94 |
38.68 |
41.42 |
44.17 |
46.91 |
49.65 |
52.39 |
55.13 |
57.87 |
60.62 |
63.36 |
66.1 |
68.84 |
71.58 |
74.32 |
77.07 |
79.81 |
82.55 |
85.29 |
88.03 |
90.77 |
93.52 |
96.26 |
99 |
101.74 |
104.48 |
107.23 |
768 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
64.01 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
108.34 |
776 |
- |
- |
- |
- |
- |
- |
- |
42.28 |
- |
- |
- |
- |
- |
- |
- |
64.67 |
- |
- |
- |
- |
- |
- |
- |
87.06 |
- |
- |
- |
- |
- |
- |
- |
109.45 |
784 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
65.33 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
110.57 |
792 |
- |
- |
- |
31.71 |
- |
- |
- |
43.14 |
- |
- |
- |
54.56 |
- |
- |
- |
65.98 |
- |
- |
- |
77.41 |
- |
- |
- |
88.83 |
- |
- |
- |
100.26 |
- |
- |
- |
111.68 |
800 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
66.64 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
112.79 |
808 |
- |
- |
- |
- |
- |
- |
- |
43.99 |
- |
- |
- |
- |
- |
- |
- |
67.3 |
- |
- |
- |
- |
- |
- |
- |
90.6 |
- |
- |
- |
- |
- |
- |
- |
113.91 |
816 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
67.95 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
115.02 |
824 |
- |
27.03 |
- |
32.97 |
- |
38.91 |
- |
44.85 |
- |
50.79 |
- |
56.73 |
- |
62.67 |
- |
68.61 |
- |
74.55 |
- |
80.49 |
- |
86.43 |
- |
92.37 |
- |
98.31 |
- |
104.25 |
- |
110.19 |
- |
116.13 |
832 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
69.27 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
117.25 |
840 |
- |
- |
- |
- |
- |
- |
- |
45.7 |
- |
- |
- |
- |
- |
- |
- |
69.92 |
- |
- |
- |
- |
- |
- |
- |
94.14 |
- |
- |
- |
- |
- |
- |
- |
118.36 |
848 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
70.58 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
119.47 |
856 |
- |
- |
- |
34.22 |
- |
- |
- |
46.56 |
- |
- |
- |
58.9 |
- |
- |
- |
71.24 |
- |
- |
- |
83.57 |
- |
- |
- |
95.91 |
- |
- |
- |
108.25 |
- |
- |
- |
120.59 |
864 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
71.89 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
121.7 |
872 |
- |
- |
- |
- |
- |
- |
- |
47.42 |
- |
- |
- |
- |
- |
- |
- |
72.55 |
- |
- |
- |
- |
- |
- |
- |
97.68 |
- |
- |
- |
- |
- |
- |
- |
122.81 |
880 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
73.21 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
123.93 |
888 |
25.88 |
29.08 |
32.28 |
35.48 |
38.68 |
41.87 |
45.07 |
48.27 |
51.47 |
54.67 |
57.87 |
61.07 |
64.27 |
67.46 |
70.66 |
73.86 |
77.06 |
80.26 |
83.46 |
86.66 |
89.86 |
93.05 |
96.25 |
99.45 |
102.65 |
105.85 |
109.05 |
112.25 |
115.45 |
118.64 |
121.84 |
125.04 |
896 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
74.52 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
126.16 |
904 |
- |
- |
- |
- |
- |
- |
- |
49.13 |
- |
- |
- |
- |
- |
- |
- |
75.18 |
- |
- |
- |
- |
- |
- |
- |
101.22 |
- |
- |
- |
- |
- |
- |
- |
127.27 |
912 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
75.83 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
128.38 |
920 |
- |
- |
- |
36.73 |
- |
- |
- |
49.98 |
- |
- |
- |
63.24 |
- |
- |
- |
76.49 |
- |
- |
- |
89.74 |
- |
- |
- |
102.99 |
- |
- |
- |
116.24 |
- |
- |
- |
129.5 |
928 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
77.14 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
130.61 |
936 |
- |
- |
- |
- |
- |
- |
- |
50.84 |
- |
- |
- |
- |
- |
- |
- |
77.8 |
- |
- |
- |
- |
- |
- |
- |
104.76 |
- |
- |
- |
- |
- |
- |
- |
131.72 |
944 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
78.46 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
132.84 |
952 |
- |
31.13 |
- |
37.99 |
- |
44.84 |
- |
51.7 |
- |
58.55 |
- |
65.41 |
- |
72.26 |
- |
79.11 |
- |
85.97 |
- |
92.82 |
- |
99.68 |
- |
106.53 |
- |
113.39 |
- |
120.24 |
- |
127.1 |
- |
133.95 |
960 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
79.77 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
135.06 |
968 |
- |
- |
- |
- |
- |
- |
- |
52.55 |
- |
- |
- |
- |
- |
- |
- |
80.43 |
- |
- |
- |
- |
- |
- |
- |
108.3 |
- |
- |
- |
- |
- |
- |
- |
136.18 |
976 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
81.08 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
137.29 |
984 |
- |
- |
- |
39.24 |
- |
- |
- |
53.41 |
- |
- |
- |
67.57 |
- |
- |
- |
81.74 |
- |
- |
- |
95.91 |
- |
- |
- |
110.07 |
- |
- |
- |
124.24 |
- |
- |
- |
138.4 |
992 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
82.4 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
139.52 |
1000 |
- |
- |
- |
- |
- |
- |
- |
54.27 |
- |
- |
- |
- |
- |
- |
- |
83.05 |
- |
- |
- |
- |
- |
- |
- |
111.84 |
- |
- |
- |
- |
- |
- |
- |
140.63 |
1008 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
83.71 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
141.74 |
1016 |
29.53 |
33.19 |
36.84 |
40.5 |
44.15 |
47.81 |
51.47 |
55.12 |
58.78 |
62.43 |
66.09 |
69.74 |
73.4 |
77.06 |
80.71 |
84.37 |
88.02 |
91.68 |
95.33 |
98.99 |
102.65 |
106.3 |
109.96 |
113.61 |
117.27 |
120.92 |
124.58 |
128.23 |
131.89 |
135.55 |
139.2 |
142.86 |
1024 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
85.02 |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
143.97 |
Last Updated on 3/28/01
By Robert W. Goodrich
Email: rgoodrich@keck.hawaii.edu