KECK NEAR INFRARED CAMERA PARTS LIST |
|
|
PART NUMBER |
DESCRIPTION |
|
|
0079 |
FINAL ASSEMBLY |
001002 |
ELECTRONIC BOX ASSEMBLY |
002001 |
SHAFT PIN SUBASSEMBLY |
002002 |
HOLDING BAR SUBASSEMBLY |
003002 |
WINDOW-BAFFLE ASSEMBLY |
005002 |
MIRROR ASSEMBLY |
007001 |
DRIVE SHAFT ASSEMBLY |
007002 |
DRIVE SHAFT ASSEMBLY |
007004 |
FILTER WHEEL DRIVE MECHANISM ASSEMBLY |
008001 |
SPRING SUPPORT ASSEMBLY |
008002 |
WHEEL SUPPORT ASSEMBLY |
008005 |
SPRING SUPPORT ASSEMBLY |
008007 |
SLIT DRIVE SUBASSEMBLY |
008008 |
SLIT DRIVE SUBASSEMBLY |
008010 |
FILTER DRIVE SUBASSEMBLY |
009000 |
MIRR.BAFF.PRISM ASSEMBLY |
009003 |
TERTIARY MIRROR ASSEMBLY |
010002 |
DEWAR ASSEMBLY |
011002 |
LENS-DETECTOR ASSEMBLY |
011002-1 |
LENS-DETECTOR ASSEMBLY(BACK-UP) |
012002 |
STEPPER MOTOR ASSEMBLY |
013002 |
FILTER WHEEL ASSEMBLY |
014002 |
SLIT MECHANISM |
016000 |
HANDLING FIXTURE FRAME |
016002 |
HANDLING FIXTURE ASSEMBLY |
016003 |
LOADING ASSEMBLY |
016004 |
END PROTECTOR BEAM |
017001 |
DESICCANT HOLDER ASSEMBLY |
020002 |
FILTER DIA.3/4 |
021002 |
FILTER WHEEL 6",20 POSITIONS |
021002-1 |
FILTER WHEEL G",GRISM POSITION |
022003 |
FILTER WHEEL COVER |
025004 |
SLIT #1 5 SLOTS |
025005 |
SLIT #2 ONE SLOT |
025004-1 |
SLIT #1 5 SLOTS(WITH CUTOUT) |
025006 |
SLIT MASK |
026001 |
PUPIL 8MM |
030004 |
PARABOLIC MIRROR |
030005 |
TERTIARY MIRROR, FLAT |
031002 |
WINDOW, DIA.5X8mm,CaF2 |
032003 |
PRISM-REFLECTOR |
032004 |
GRISM, 120 GROOVE |
032005 |
GRISM BASE, SAPPHIRE |
032006 |
GRISM, 60 GROOVE |
032007 |
GRISM, 150 GROOVE |
033003 |
BI-CONVEX LENS |
033004 |
MENISCUS LENS |
033005 |
MENISCUS LENS |
033006 |
MENISCUS LENS |
033007 |
BI-CONVEX LENS |
033008 |
MENISCUS LENS |
033009 |
MENISCUS LENS |
040004 |
BAFFLE, G-10 SH 6" |
040011 |
BAFFLE |
040012 |
BAFFLE, G10 & SS SH |
040013 |
WINDOW BAFFLE |
040014 |
BAFFLE FOR LENS BARREL |
040015 |
BAFFLE FOR MULTI-JAW |
040016 |
BAFFLE |
040019 |
BAFFLE FOR COUPLING |
040019-1 |
BAFFLE FOR COUPLING |
040020 |
BAFFLE |
040020-1 |
BAFFLE |
040022 |
SHIELD CABLE BAFFLE |
040025 |
EMITTER BAFFLE |
040026 |
BAFFLE FOR LENS MOUNTING |
040028 |
BAFFLE |
040029 |
BAFFLE |
040030 |
BAFFLE, DETECTOR MTG BLOCK |
041006 |
BAFFLE PLATE, COLD SURFACE |
041010 |
MAIN BAFFLE FIN |
041014 |
FIN, BACK |
041005 |
FIN, FRONT |
042002 |
MAIN BAFFLE BRACKET |
043003 |
MOUNTING RING |
050004 |
ADJUSTABLE MIRROR MOUNTING,NEWPORT GM-2 |
050005 |
MIRROR MOUNTING |
050010 |
MIRROR HOLDER |
050011 |
SIDE MIRROR SUPPORT |
051002 |
MIRROR MOUNTING FRAME |
052010 |
MIRROR HOLDER |
051013 |
TERTIARY BOX COVER |
052003 |
MIRROR HOLDER |
060004 |
PRISMHOLDER-LEFT |
060005 |
GRISM HOLDER |
060006 |
GRISM HOLDER |
060010 |
PRISM HOLDER-BAFFLE |
070002 |
WINDOW COVER |
071001 |
WINDOW HOLDER |
080003 |
LENS HOLDER, EXTERIOR |
080004 |
LENS BARREL |
080005 |
LENS HOLDER MOUNTING |
080006 |
LENS BARREL |
081002 |
LENS RETAINER |
099001 |
OPTICAL LAYOUT |
1OOOOO |
SPECIAL SHAFT |
100130-2 |
SHAFT DIA .125 |
100130-3 |
SHAFT .686X1/8~.098 |
100130-4 |
.72L SHAFT 1/8&.098 |
100131 |
SHAFT DIA.125 |
100131-1 |
SHAFT 1/8X1.5L SS |
100131-2 |
1/8X1.35 SHAFT S.S. |
100131-4 |
0.125 SHAFT 2.588 LG |
100131-5 |
SHAFT 1/8X1.6 |
100131-8 |
SHAFT, DIA. 0.125 |
100131-13 |
V SHAFT DIA. 1/8X3.6L |
100132 |
SHAFT 1/8 |
100134 |
CAM SHAFT .125&.098X.685 |
100134-1 |
SHAFT .098&.125 DIA. |
100188 |
SHAFT, DIA. 0.1875 |
100191 |
SHAFT 3/16 X 4.625 |
100250 |
SHAFT DIA .25X2.624 |
100625 |
SHAFT, DIA.5/8 |
101130 |
SHAFT G-10 1/8X8 |
101131 |
G10 SHAFT 1/8 DIA.X1.250 |
101131-1 |
G-10 GLASS CLOTH SHAFT, 21.5" LHE DAMP |
101131-2 |
G-10 GLASS CLOTH SHAFT, 34.5" LN2 DAMP |
102220 |
SHAFT ADAPTER-MOD |
102290 |
SHAFT ADAPTER, 1/8 TO #4-40 THD. |
11OOO1 |
PLATE |
110001-1 |
PLATE |
110002 |
COLD PLATE |
111017 |
MOUNTING PLATE, DIA. 11.062 |
111018 |
MOUNTING PLATE, DIA. 11.450 |
111019 |
MOUNTING PLATE |
111020 |
MOUNTING PLATE |
111027 |
MOUNTING BLOCK |
111027-1 |
MOUNTING BLOCK |
111028 |
MTG PLATE, STEPPER |
111029 |
MTG PLATE,TERTIARY |
111030 |
MOUNTING PLATE |
111031 |
MTG PLATE,MIRROR MOUNT |
111032 |
CONNECTOR PLATE 1/8 |
111033 |
SIDE PLATE 3/32 |
111034 |
FEED THRU MTG |
111035 |
FACE PLATE, STEPPER |
111036 |
BASE PLATE |
111037 |
DEWAR MTG WASHER PLATE |
111043 |
E-BOX BOTTOM PLATE |
111043-1 |
E-BOX BOTTOM PLATE |
111044 |
E-BOX FRONT PLATE |
111044-1 |
E-BOX FRONT PLATE |
111045 |
E-BOX REAR PLATE |
111045-1 |
E-BOX REAR PLATE |
111046 |
E-BOX SIDE PLATE |
111046-1 |
E-BOX SIDE PLATE |
111046-2 |
E-BOX SIDE PLATE |
112001 |
MOUNTING BLOCK |
112002 |
MOUNTING BLOCK |
112008 |
H.MOUNTING BLOCK |
112014 |
BEARING MOUNTING BLOCK |
112015 |
MTG BK 1.25X.5X.5 |
112016 |
MTG BLOCK,GEARMOTOR |
112017 |
MTG BLOCK, DETECTOR |
112019 |
EMITTER BLOCK |
112020 |
WEDGE BLOCK |
112021 |
WEDGE BLOCK |
112022 |
WEDGE BLOCK |
112022-1 |
WEDGE BLOCK |
112023 |
CENTER BLOCK |
112024 |
CONNECTOR MTG BLOCK |
112025 |
CONNECTOR BLOCK |
112026 |
DEWAR CENTER BLOCK |
112027 |
SUPPORT BLOCK |
112027-1 |
SUPPORT BLOCK |
112028 |
MOUNTING BLOCK |
112029 |
DETECTOR-LENS MOUNTING BLOCK |
112031 |
SPACER BLOCK, 2.4" |
112036 |
SPACER BLOCK |
112046 |
MTG. BLOCK,PIPE CLAMP |
112057 |
SPACER BLOCK, PHENOLIC |
112058 |
HEATER MOUNTING BLOCK |
113002-2 |
STOP FOR SLIT .5"L |
113002-3 |
STOP FOR SLIT .15"L |
113010 |
STEPPER MOUNTING SPACER |
113011 |
MOUNTING BRACKE |
113013 |
V. MTG. BRACKET |
113014 |
ELEC. MTG. BRACKET |
113015 |
SLIT MECHANISM MOUNTING BRACKET |
113016 |
DEWAR LOADING GUARD |
113017 |
MOUNTING BRACKET |
113018 |
MTG. BRACKET,PIPE CLAMP |
114002 |
ADAPTOR SLIT MOUNT |
114004 |
ADAPTOR BLOCK |
114005 |
ADAPTOR BLOCK |
115001 |
MOUNTING COVER |
115006 |
TERTIARY BOX |
115008 |
CONNECTOR BOX |
115009 |
CONNECTOR BOX COVER |
115010 |
DIE CAST BLACK BOX,POMONA 3754 |
115011 |
FEED THRU COVER |
115012 |
READOUT CHIP COVER |
115013 |
CONNECTOR COVER PLATE |
115013-1 |
CONNECTOR COVER PLATE |
115014 |
DUST COVER |
115015 |
BOX COVER FOR 115010 |
115016 |
PROTECTING BOX FOR STEPPER ASSEMBLY |
115017 |
PROTECTING BOX FOR STEPPER ASSEMBLY |
115018 |
PROTECTING COVER |
115021 |
E-BOX COVER |
115021-1 |
E-BOX COVER |
115023 |
GEAR COVER |
115025 |
HEATER COVER PLATE |
116002 |
DETECTOR MTG. BASE |
117004 |
CAM LEVER ARM |
117006 |
DEWAR LOADING BEAM |
117006-1 |
LOADING BEAM |
117008 |
DEWAR GUARD |
117008-1 |
DEWAR GUARD |
117009 |
CLIP BAR, CONNECTOR |
117010 |
PC BOARD GUARD, RELAY BOARD |
118002 |
STEPPER MTG. SPACER |
118003 |
HOLDING BAR |
118003-1 |
HOLDING BAR |
118004 |
BAR END |
119001 |
DESICCANT HOLDER |
119002 |
STEPPER FEED THRU |
120001 |
ROLLER, WHEEL SUPPORT |
121002 |
CAM OFF CENTER .054 |
121003 |
SWITCH ACTUATING CAM |
130002 |
SPUR GEAR 96PITCH,WM BERG P96510-48 |
130003 |
SPUR GEAR 120P, DYNACO 666-20S-P2 |
130004 |
FILTER WH SPUR GEAR |
131002 |
96 PITCH BEVEL 3/8 P |
131002-1 |
96 PITCH BEVEL 3/4 P |
131003 |
72 PITCH BEVEL GEAR SET 3:4 |
132001 |
RACK 120P 5" LG, PIC AG160-5 SP |
133001 |
HELICAL GEAR,64P,20N |
133002 |
WORM GEAR,1OP, 40N, CASE IRON |
133003 |
WORM,1OP, 1.25PD,1-5/8 FACE |
150022 |
WAFER SPRING COUPLING,BERG C020-4 |
150122 |
MULTI JAW CPL 17/32,BERG CM3-1 |
150201 |
SLIP COUPLING, BERG JJ-l |
150301 |
TELESCOPE UNIV. COUPLING,BERG UJT-5 |
150302 |
TELESCOPE UNIV. COUPLING,BERG UJT-3 |
150401 |
HELI-CAL 3035-4-4 COUPLING |
160400 |
SPLIT TYPE CLAMP, PIC L4-3 |
160402 |
SPLIT HUB CLAMP CS |
160403 |
ROUND CABLE CLAMP |
160404 |
PIPE CLAMP |
160405 |
PIPE CLAMP |
170001 |
32DP NO SLIP PULLEY, PIC FD6-40 |
170002 |
CRANE SLINGS, NYLON, MMC8864T61 |
171001 |
HAND WHEEL, MMC6021K42 |
200002 |
UPPER DEWAR CASE OCTAGON |
200003 |
LOWER DEWARCASE ROUND |
201001 |
DEWAR TOP COVER |
201003 |
DEWAR BOTTOM PLATE |
202001 |
LHE CAN |
202002 |
LN2 CAN |
203001 |
DEWAR SHIELD |
203002 |
LN2 CAN SUPPORT G-10 |
203003 |
LHE CAN SUPPORT,G-10 |
203100 |
DEWAR SHIELD COVER |
204001 |
DEWAR PUMP VALVE |
204005 |
PUP OFF, CIRCLE SEAL |
204007 |
PIPE FITTING AT WINDOW |
204008 |
PIPE NIPPLE, 1/4 TO 1/8 |
204009 |
CHECK VALVE, CIRCLE SEAL119-A-1PP |
204010 |
FEMALE RUN TEE,SWAGELOK A-600-3TFT |
204011 |
TUBE ADAPTOR,SWAGELOK A-6-TA-1-2 |
204012 |
PLUG,SWAGELOK A-600-P |
204013 |
REDUCER,SWAGELOK A-200-R-6 |
204014 |
NUT,SWAGELOK SS-602-1, 3/8 TUBE |
204015 |
POROUS METAL PRESSURE SNUBBER, CHEMIQUIP 12S-C, 1.1X1/2HEX |
204016 |
METAL FLOAT,SEYMOUR-SHERIDAN 57000-2 |
204017 |
STREET ELBOW, CAJON SS-2-SE, 1/8NPT |
204018 |
COUPLING,HANSEN LL1-ST11 |
204019 |
HEX NIPPLE, CAJON SS-2-HE, 1/8NPT |
205001 |
HELIUM FILL |
205002 |
NITROGEN FILL |
205003 |
LHE VENT TUBE |
205004 |
LN2 VENT TUBE |
205005 |
LN2 LEVEL PROBE |
205006 |
LHE LEVEL PROBE |
205007 |
FILL TUBE SUPPORT |
205008 |
LHE FILL TUBE |
205009 |
LN2 FILL TUBE |
210001 |
STAINLESS PIPE 1/8 DIA. |
300002 |
CIRCUIT BOARD |
301002 |
CHIP CARRIER ASSEMBLY, SBRC INSB |
305001 |
STEPPER MOTOR DRIVING SCHEMATIC |
310002 |
CHIP CARRIER SOCKET,TEXT 268-4963 |
350001 |
BRAID SHIELD CABLE |
380001 |
MICRO SWITCH 11SM1-T |
380501 |
SWITCH ACTUATOR JS-2 |
400002 |
STEPPER SIZE23 1.54L,ORIENTAL PH264-E1.5 |
400100 |
GEAR MOTOR,PLANETARY,GLOBAL 168A237-5 |
440002 |
INSULATOR, G-10 |
450001 |
WIRE CLOTH, MMC 9226 W312 |
460001 |
PERFORATED SHEET, MMC9232T12 |
460002 |
PERFORATED SHEET, MMC9232T12 |
500012 |
PAN HD. SCREW 0-80 |
500204 |
#2-56X1/2 HEX SOCKET CAP SCREW |
500207 |
#2-56X7/8 SCREW,CAP,HEX SOCKET HEAD |
500208 |
#2-56X1 SCREW,CAP,HEX SOCKET HEAD |
500490 |
HEX SOCKET CAP SCREW #4-40X3/16 |
500530 |
1/2X13X2.75 HEX SOCKET SCREW |
501691 |
#6-80 SET SCREW SPECIAL |
501692 |
SET SCREW #6-80 |
502012 |
NUT, 1/2-13 |
503003 |
FILTER WHEEL HANDLE |
504006 |
KNURL NUT |
504007 |
KNURL NUT |
505904 |
CAPTIVE SCREW #2-56, SHIELD COVER |
505906 |
1/2-13X4.5 CAPTIVE SCREW |
505907 |
CAPTIVE SCREW #8-32, TERTIARY MTG |
505908 |
CAPTIVE SCREW #4-40, TERTIARY BOX MTG |
506001 |
SPRING PLUNGER, #8-32 X 5/8,VLIER NNS-51 |
507912 |
EYE BOLT,1/2-13,S.S,SHOULDER |
601001-4 |
SPACER .291X1/8X3/16 |
601001-5 |
SPACER .078X1/8X3/16 |
601001-6 |
SPACER .040X1/8X3/16 |
601001-7 |
SPACER 1/8 |
601007 |
.126X.148X1.129L SPACER |
601007-1 |
SPACER .126X.148X.06 |
601008 |
SPACER .248X1/8X.100 |
601008-1 |
SPACER .685 |
601008-2 |
SPACER .72L |
601009 |
10.9375 OD SPACER |
601010 |
INNER SPACER, 3PCS |
601011 |
LENS SPACER 90 DEG |
601012 |
SPACER 1/4X3/8X.122 |
601013 |
SPACER, DIA.1 & 5/8 |
601014 |
SPACER |
601015 |
BAR SPACER |
601017 |
LENS SPACER |
601018 |
LENS SPACER |
601019 |
LENS SPACER |
601020 |
LENS SPACER |
601021 |
FILTER SPACE |
602010 |
SHIM .01X1/8 ID, PIC B4-4 |
602110 |
SHIM 3/16X1/4X.010 |
602410 |
SHIM .167X1/4X.01 OD |
602501 |
SHIM |
602801 |
SHIM |
602901 |
SHIM 1X.6X.020 THICK |
603004 |
WASHER ID 3/4, OD 1-1/8 |
603501 |
SPHERIC WASHER,CONVEX |
603500 |
SPHERIC WASHER,CONCAVE |
605003 |
BUSHING,WEDGED |
605004 |
BUSHING,PLAIN |
605005 |
SPRING BUSH |
605008 |
SPRING BUSHING, SHIELD COVER |
605009 |
STANDOFF |
610003 |
SPRING POST |
610003-1 |
SPRING POST |
620001 |
EXTERNAL RETAINING RING, 3/4 DIA. |
650901 |
CENTER PIN |
653003 |
SWITCH PUSH ROD |
653004 |
LOCKING PIN, DIA.1/2X4,MMC92384A103 |
680001 |
INSERT, NYLON |
680002 |
MIRROR PAD, ALUMINUM |
680003 |
MIRROR PAD, NYLON 6/6 |
700102 |
EXTENSION SPRING LE026B-002 |
700103 |
EXTENSION SPRING,ASSOC.E0300-055-112S |
700201 |
COMP SPRING, ASSOC.C0088-012-0250S |
700202 |
COMPRESS SPRING, LC063H-14 |
700203 |
COMPRESS SP. ASSOC. C0120-020-0250S |
700204 |
COMP SPRING,ASSOC.C0240-O20-0380S |
702000 |
WAVE SP WASHER,ASSOC. W0183-004-S |
702001 |
WAVE SP WASHER,ASSOC W0242-006-S |
702005 |
WAVE SP WASHER .875,BERG SV-5 |
702202 |
WAVE SPRING WASHER, ASSO W2132-023 |
703001 |
MUSIC WIRE SS. .025D |
750001 |
CONNECTOR, MS3114, SHELL 20 |
750002 |
CONNECTOR, MS3114, SHELL 24 |
750003 |
CONNECTOR M3102-12-10P |
750004 |
CONNECTOR JT02-8-6P |
750005 |
CONNECTOR SHELL 16 |
750007 |
CONNECTOR, MS3112, PT 02-8-3P |
800001 |
BALL BEARING, WM BERG B1-35 |
800003 |
BALL BEARING 1/4X3/8X1/8 |
800011 |
BALL BEARING, WM BERG B1-43S |
800101 |
FLANGE BALL BEARING, WM BERG B2-14 |
800102 |
FLANGED BALL BEARING 3/16X5/16X.109 |
805004 |
LINEAR BALL SLIDE PIC PB05-40 |
805010 |
STATIONARY PT-805004 |
805015 |
LINEAR SLIDE, BOTTOM |
805016 |
LINEAR SLIDE, TOP |
806001 |
FLANGE SLEEVE BEARING, BOSTON FAF 2428-12 |
806002 |
BRONZE BEARING, BOSTON FB1012-5 |
900001 |
O-RING, #244 |
900002 |
O-RING, #246 |
900008 |
O-RING, PARKER 2-010 |
900010 |
O-RING, PARKER 2-016 |
901005 |
LENS ASSEMBLING FIXTURE |
901006 |
SANTA'S BEST GARLAND MINI TRIM,18l1/2" |
901007 |
HEATER, OMEGA CIR10151-120V, 200 W |
902001 |
MULTIDIAL 1.75X1X1 |
903001 |
SHIPPING CONTAINER |
903002 |
FILTER WHEEL CARRYING CASE |
|
|