JHKL photometric standards used at MSSSO (see PASP, 106, 508).

Mount Stromlo and Siding Spring Observatories Near-IR Photometric Standards
Star RA(2000) Dec(2000) m(a) m(d) Sp. Type V K J-K H-K K-L
      (s/yr) ("/yr)            
Y 5817 00h 05m 24.4s -37° 21' 26" 0.4733 -2.337 M4 V 8.63 4.529 0.753 0.214 0.172
HR 33 00h 11m 15.8s -15° 28' 05" -0.0056 -0.264 F7 V 4.89 3.646 0.290 0.034 0.018
HR 77 00h 20m 04.2s -64° 52' 30" 0.3685 1.167 F9 V 4.23 2.832 0.334 0.039 0.021
Y 392 01h 52m 49.0s -22° 26' 06" 0.0598 0.004 M1 V 8.7 5.223 0.838 0.168 0.110
HR 612 02h 04m 29.4s -29° 17' 49" 0.0008 0.010 B9.5pSi 4.69 5.073 -0.101 -0.049 -0.040
HR 740 02h 32m 05.1s -15° 14' 41" -0.0053 -0.117 F4 IV 4.75 3.589 0.270 0.033 0.013
HR 818 02h 45m 06.1s -18° 34' 21" 0.0229 0.042 F6 V 4.47 3.344 0.251 0.040 0.009
Y 642 03h 06m 26.7s 01° 57' 57" 0.0245 -0.897 M0 V 9.10 5.674 0.804 0.140 0.078
Y 1181 05h 11m 40.5s -45° 01' 16" 0.6156 -5.734 M0 V 8.86 5.073 0.745 0.224 0.187
Y 1255 05h 31m 27.3s -03° 40' 39" 0.0506 -2.103 M1 V 7.98 3.886 0.889 0.189 0.120
HR 1983 05h 44m 27.8s -22° 26' 54" -0.0212 -0.373 F6 V 3.60 2.419 0.270 0.031 0.004
HR 2015 05h 44m 46.5s -65° 44' 08" -0.0042 0.007 A7 V 4.35 3.723 0.135 0.026 0.012
HR 2020 05h 47m 17.1s -51° 03' 59" 0.0005 0.087 A5 V 3.85 3.489 0.069 0.012 0.013
HR 2085 05h 56m 24.2s -14° 10' 04" -0.0034 0.136 F1 III 3.71 2.908 0.172 0.027 0.010
HR 2451 06h 37m 45.6s -43° 11' 45" -0.0006 -0.005 B8 III 3.17 3.381 -0.051 -0.023 -0.010
HR 3314 08h 25m 39.6s -03° 54' 23" -0.0047 -0.027 A0 V 3.90 3.930 -0.016 -0.008 -0.021
Y 2267 09h 31m 19.6s -13° 29' 18" 0.0500 0.059 M4 V 10.04 5.554 0.847 0.243 0.185
HR 3842 09h 38m 01.4s -43° 11' 27" 0.0022 -0.035 G8 II 5.50 3.409 0.538 0.084 0.055
HR 3871 09h 44m 12.1s -27° 46' 10" -0.0037 0.030 A8 V 4.79 3.255 0.440 0.072 0.038
V 569 10h 12m 17.6s -03° 44' 43" -0.0105 -0.232 M2 V 9.30 5.034 0.869 0.222 0.142
HR 4102 10h 24m 23.7s -74° 01' 54" -0.0044 -0.031 F2 IV 4.00 3.140 0.186 0.026 0.004
HR 4450 11h 33m 00.1s -31° 51' 27" -0.0162 -0.042 G7 III 3.54 1.448 0.548 0.087 0.058
HR 4638 12h 11m 39.1s -52° 22' 06" -0.0038 -0.019 B3 V 3.96 4.449 -0.125 -0.052 -0.052
HR 4773 12h 32m 28.0s -72° 07' 58" -0.0104 -0.009 B5 V 3.87 4.303 -0.122 -0.050 -0.054
HR 4802 12h 37m 42.1s -48° 32' 28" -0.0187 -0.008 A2 V 3.86 3.710 0.035 0.010 0.004
Y 2951 12h 50m 43.5s -00° 46' 05" -0.0029 -0.395 M0 V 8.51 4.957 0.832 0.160 0.073
HR 4989 13h 14m 14.7s -59° 06' 12" -0.0339 -0.161 F7 IV 4.92 3.684 0.301 0.041 0.008
HR 5028 13h 20m 35.7s -36° 42' 44" -0.0283 -0.089 A2 V 2.75 2.697 0.007 0.000 -0.002
HR 5249 13h 58m 40.7s -44° 48' 13" -0.0024 -0.024 B2 IV-V 3.87 4.509 -0.165 -0.070 -0.065
Y 3269 14h 34m 16.7s -12° 31' 13" -0.0233 0.599 M4 V 11.36 5.986 0.894 0.294 0.230
Y 3375B 14h 57m 26.6s -21° 24' 44" 0.0731 -1.713 M2 V 7.91 3.938 0.859 0.217 0.170
Y 3501 15h 32m 13.1s -41° 16' 35" -0.1022 -1.020 M4 V 9.30 4.792 0.876 0.242 0.186
Y 3746 16h 30m 18.0s -12° 39' 48" -0.0048 -1.173 M4 V 10.10 5.115 0.847 0.273 0.227
HR 6147 16h 31m 08.2s -16° 36' 46" -0.0037 -0.038 G8 IIIa 4.28 2.274 0.506 0.092 0.049
Y 3845 16h 55m 28.9s -08° 20' 10" -0.0542 -0.877 M3eV 8.98 4.420 0.821 0.243 0.199
HR 6378 17h 10m 22.6s -15° 43' 29" 0.0026 0.095 A2 V 2.43 2.275 0.018 0.011 0.006
Y 3958 17h 28m 40.2s -46° 53' 45" 0.0555 -0.876 M4 V 9.36 4.888 0.833 0.247 0.200
Y 3992 17h 37m 03.4s -44° 19' 11" -0.0637 -0.931 M5 11.2 5.658 0.925 0.282 0.240
Y 4338 18h 49m 50.0s -23° 50' 12" 0.0503 -0.207 M4eV 10.95 5.380 0.850 0.293 0.257
HR 7340 19h 21m 40.3s -17° 50' 50" -0.0018 0.024 F0 IV-V 3.93 3.371 0.120 0.026 0.015
Y 4794 20h 13m 53.3s -45° 09' 47" 0.0726 -0.133 M0 V 7.97 4.279 0.830 0.186 0.125
HR 7773 20h 20m 39.7s -12° 45' 33" 0.0011 -0.018 B9.5 V 4.76 4.854 -0.040 -0.006 0.002
Y 4924 20h 42m 18.4s -52° 41' 56" 0.0074 -1.067 K7 V 8.83 5.504 0.803 0.147 0.093
HR 7950 20h 47m 40.5s -09° 29' 45" 0.0022 -0.032 A1 V 3.77 3.697 0.007 0.005 0.016
Y 5117 21h 17m 15.0s -38° 52' 06" -0.2787 -1.153 M0 V 6.67 3.078 0.832 0.162 0.110
Y 5190 21h 33m 34.0s -49° 00' 32" -0.0055 -0.798 M1 V 8.68 4.482 0.822 0.225 0.178
HR 8278 21h 40m 05.4s -16° 39' 45" 0.0131 -0.022 F0p 3.68 3.045 0.128 0.024 0.020
Y 5243 21h 46m 35.9s -57° 42' 11" 0.0120 -0.873 K7 V 8.80 5.464 0.803 0.153 0.085
Y 5358 22h 09m 39.9s -04° 38' 28" 0.0693 -0.027 M3 V 10.12 5.626 0.900 0.249 0.185
Y 5475 22h 38m 33.5s -15° 18' 00" 0.1634 2.236 M6eV 12.18 5.591 0.978 0.364 0.315
Y 5546 22h 53m 17.1s -14° 15' 45" 0.0656 -0.631 M5 V 10.10 5.044 0.896 0.276 0.217
HR 8709 22h 54m 38.9s -15° 49' 15" -0.0029 -0.022 A3 V 3.27 3.067 0.046 0.014 0.010
Y 5572 23h 00m 16.0s -22° 31' 28" -0.0658 0.062 M1 V 7.90 4.486 0.808 0.152 0.093
Y 5584 23h 05m 52.0s -35° 51' 12" 0.5575 1.330 M2 V 7.34 3.382 0.829 0.218 0.162
HR 8848 23h 17m 25.7s -58° 14' 08" -0.0032 0.089 F1 III 3.99 2.967 0.233 0.034 0.021



Last Updated on 6/2/98
By Bob Goodrich