4500.00 0. 4502.44 0. 4504.89 0. 4507.33 0. 4509.77 0. 4512.22 0. 4514.66 0. 4517.10 0. 4519.54 0. 4521.99 0. 4524.43 0. 4526.87 0. 4529.32 0. 4531.76 0. 4534.20 0. 4536.65 0. 4539.09 0. 4541.53 0. 4543.97 0. 4546.42 0. 4548.86 0. 4551.30 0. 4553.75 0. 4556.19 0. 4558.63 0. 4561.08 0. 4563.52 0. 4565.96 0. 4568.40 0. 4570.85 0. 4573.29 0. 4575.73 0. 4578.18 0. 4580.62 0. 4583.06 0. 4585.51 0. 4587.95 0. 4590.39 0. 4592.83 0. 4595.28 0. 4597.72 0. 4600.16 0. 4602.61 0. 4605.05 0. 4607.49 0. 4609.94 0. 4612.38 0. 4614.82 0. 4617.26 0. 4619.71 0. 4622.15 0. 4624.59 0. 4627.04 0. 4629.48 0. 4631.92 0. 4634.37 0. 4636.81 0. 4639.25 0. 4641.69 0. 4644.14 0. 4646.58 0. 4649.02 0. 4651.47 0. 4653.91 0. 4656.35 0. 4658.80 0. 4661.24 0. 4663.68 0. 4666.12 0. 4668.57 0. 4671.01 0. 4673.45 0. 4675.90 0. 4678.34 0. 4680.78 0. 4683.23 0. 4685.67 0. 4688.11 0. 4690.55 0. 4693.00 0. 4695.44 0. 4697.88 0. 4700.33 0. 4702.77 0. 4705.21 0. 4707.66 0. 4710.10 0. 4712.54 0. 4714.98 0. 4717.43 0. 4719.87 0. 4722.31 0. 4724.76 0. 4727.20 0. 4729.64 0. 4732.09 0. 4734.53 0. 4736.97 0. 4739.41 0. 4741.86 0. 4744.30 0. 4746.74 0. 4749.19 0. 4751.63 0. 4754.07 0. 4756.52 0. 4758.96 0. 4761.40 0. 4763.84 0. 4766.29 0. 4768.73 0. 4771.17 0. 4773.62 0. 4776.06 0. 4778.50 0. 4780.95 0. 4783.39 0. 4785.83 0. 4788.27 0. 4790.72 0. 4793.16 0. 4795.60 0. 4798.05 0. 4800.49 0. 4802.93 0. 4805.38 0. 4807.82 0. 4810.26 0. 4812.70 0. 4815.15 0. 4817.59 0. 4820.03 0. 4822.48 0. 4824.92 0. 4827.36 0. 4829.81 0. 4832.25 0. 4834.69 0. 4837.13 0. 4839.58 0. 4842.02 0. 4844.46 0. 4846.91 0. 4849.35 0. 4851.79 0. 4854.24 0. 4856.68 0. 4859.12 0. 4861.56 0. 4864.01 0. 4866.45 0. 4868.89 0. 4871.34 0. 4873.78 0. 4876.22 0. 4878.67 0. 4881.11 0. 4883.55 0. 4885.99 0. 4888.44 0. 4890.88 0. 4893.32 0. 4895.77 0. 4898.21 0. 4900.65 0. 4903.10 0. 4905.54 0. 4907.98 0. 4910.42 0. 4912.87 0. 4915.31 0. 4917.75 0. 4920.20 0. 4922.64 0. 4925.08 0. 4927.53 0. 4929.97 0. 4932.41 0. 4934.85 0. 4937.30 0. 4939.74 0. 4942.18 0. 4944.63 0. 4947.07 0. 4949.51 0. 4951.96 0. 4954.40 0. 4956.84 0. 4959.28 0. 4961.73 0. 4964.17 0. 4966.61 0. 4969.06 0. 4971.50 0. 4973.94 0. 4976.39 0. 4978.83 0. 4981.27 0. 4983.71 0. 4986.16 0. 4988.60 0. 4991.04 0. 4993.49 0. 4995.93 0. 4998.37 0. 5000.82 0. 5003.26 0. 5005.70 0. 5008.14 0. 5010.59 0. 5013.03 0. 5015.47 0. 5017.92 0. 5020.36 0. 5022.80 0. 5025.25 0. 5027.69 0. 5030.13 0. 5032.57 0. 5035.02 0. 5037.46 0. 5039.90 0. 5042.35 0. 5044.79 0. 5047.23 0. 5049.68 0. 5052.12 0. 5054.56 0. 5057.00 0. 5059.45 0. 5061.89 0. 5064.33 0. 5066.78 0. 5069.22 0. 5071.66 0. 5074.11 0. 5076.55 0. 5078.99 0. 5081.43 0. 5083.88 0. 5086.32 0. 5088.76 0. 5091.21 0. 5093.65 0. 5096.09 0. 5098.54 0. 5100.98 0. 5103.42 0. 5105.86 0. 5108.31 0. 5110.75 0. 5113.19 0. 5115.64 0. 5118.08 0. 5120.52 0. 5122.97 0. 5125.41 0. 5127.85 0. 5130.29 0. 5132.74 0. 5135.18 0. 5137.62 0. 5140.07 0. 5142.51 0. 5144.95 0. 5147.40 0. 5149.84 0. 5152.28 0. 5154.72 0. 5157.17 0. 5159.61 0. 5162.05 0. 5164.50 0. 5166.94 0. 5169.38 0. 5171.83 0. 5174.27 0. 5176.71 0. 5179.15 0. 5181.60 0. 5184.04 0. 5186.48 0. 5188.93 0. 5191.37 0. 5193.81 0. 5196.26 0. 5198.70 0. 5201.14 0. 5203.58 0. 5206.03 0. 5208.47 0. 5210.91 0. 5213.36 0. 5215.80 0. 5218.24 0. 5220.69 0. 5223.13 0. 5225.57 0. 5228.01 0. 5230.46 0. 5232.90 0. 5235.34 0. 5237.79 0. 5240.23 0. 5242.67 0. 5245.12 0. 5247.56 0. 5250.00 0. 5252.44 0. 5254.89 0. 5257.33 0. 5259.77 0. 5262.22 0. 5264.66 0. 5267.10 0. 5269.55 0. 5271.99 0. 5274.43 0. 5276.87 0. 5279.32 0. 5281.76 0. 5284.20 0. 5286.65 0. 5289.09 0. 5291.53 0. 5293.98 0. 5296.42 0. 5298.86 0. 5301.30 0. 5303.75 0. 5306.19 0. 5308.63 0. 5311.08 0. 5313.52 0. 5315.96 0. 5318.41 0. 5320.85 0. 5323.29 0. 5325.73 0. 5328.18 0. 5330.62 0. 5333.06 0. 5335.51 0. 5337.95 0. 5340.39 0. 5342.84 0. 5345.28 0. 5347.72 0. 5350.16 0. 5352.61 0. 5355.05 0. 5357.49 0. 5359.94 0. 5362.38 0. 5364.82 0. 5367.27 0. 5369.71 0. 5372.15 0. 5374.59 0. 5377.04 0. 5379.48 0. 5381.92 0. 5384.37 0. 5386.81 0. 5389.25 0. 5391.70 0. 5394.14 0. 5396.58 0. 5399.02 0. 5401.47 0. 5403.91 0. 5406.35 0. 5408.80 0. 5411.24 0. 5413.68 0. 5416.13 0. 5418.57 0. 5421.01 0. 5423.45 0. 5425.90 0. 5428.34 0. 5430.78 0. 5433.23 0. 5435.67 0. 5438.11 0. 5440.56 0. 5443.00 0. 5445.44 0. 5447.88 0. 5450.33 0. 5452.77 0. 5455.21 0. 5457.66 0. 5460.10 0. 5462.54 0. 5464.99 0. 5467.43 0. 5469.87 0. 5472.31 0. 5474.76 0. 5477.20 0. 5479.64 0. 5482.09 0. 5484.53 0. 5486.97 0. 5489.42 0. 5491.86 0. 5494.30 0. 5496.74 0. 5499.19 0. 5501.63 0. 5504.07 0. 5506.52 0. 5508.96 0. 5511.40 0. 5513.85 0. 5516.29 0. 5518.73 0. 5521.17 0. 5523.62 0. 5526.06 0. 5528.50 0. 5530.95 0. 5533.39 0. 5535.83 0. 5538.28 0. 5540.72 0. 5543.16 0. 5545.60 0. 5548.05 0. 5550.49 0. 5552.93 0. 5555.38 0. 5557.82 0. 5560.26 0. 5562.71 0. 5565.15 0. 5567.59 0. 5570.03 0. 5572.48 0. 5574.92 0. 5577.36 0. 5579.81 0. 5582.25 0. 5584.69 0. 5587.14 0. 5589.58 0. 5592.02 0. 5594.46 0. 5596.91 0. 5599.35 0. 5601.79 0. 5604.24 0. 5606.68 0. 5609.12 0. 5611.57 0. 5614.01 0. 5616.45 0. 5618.89 0. 5621.34 0. 5623.78 0. 5626.22 0. 5628.67 0. 5631.11 0. 5633.55 0. 5636.00 0. 5638.44 0. 5640.88 0. 5643.32 0. 5645.77 0. 5648.21 0. 5650.65 0. 5653.10 0. 5655.54 0. 5657.98 0. 5660.43 0. 5662.87 0. 5665.31 0. 5667.75 0. 5670.20 0. 5672.64 0. 5675.08 0. 5677.53 0. 5679.97 0. 5682.41 0. 5684.86 0. 5687.30 0. 5689.74 0. 5692.18 0. 5694.63 0. 5697.07 0. 5699.51 0. 5701.96 0. 5704.40 0. 5706.84 0. 5709.29 0. 5711.73 0. 5714.17 0. 5716.61 0. 5719.06 0. 5721.50 0. 5723.94 0. 5726.39 0. 5728.83 0. 5731.27 0. 5733.72 0. 5736.16 0. 5738.60 0. 5741.05 0. 5743.49 0. 5745.93 0. 5748.37 0. 5750.82 0. 5753.26 0. 5755.70 0. 5758.15 0. 5760.59 0. 5763.03 0. 5765.48 0. 5767.92 2.850266E-8 5770.36 -2.034713E-7 5772.80 3.673639E-7 5775.25 2.923143E-5 5777.69 -1.053453E-4 5780.13 1.504182E-4 5782.58 0.005980029 5785.02 0.009248798 5787.46 0.009094762 5789.91 0.009026653 5792.35 0.009048637 5794.79 0.009008511 5797.23 0.0089763 5799.68 0.009031899 5802.12 0.009004073 5804.56 0.008982699 5807.01 0.00901354 5809.45 0.00899909 5811.89 0.008960064 5814.34 0.008957623 5816.78 0.009003539 5819.22 0.009003079 5821.66 0.008940878 5824.11 0.008941587 5826.55 0.008903293 5828.99 0.008921413 5831.44 0.008955148 5833.88 0.008959021 5836.32 0.008944378 5838.77 0.00892351 5841.21 0.008976448 5843.65 0.009044 5846.09 0.009047703 5848.54 0.009009786 5850.98 0.008995914 5853.42 0.009002003 5855.87 0.009025268 5858.31 0.009012006 5860.75 0.009030968 5863.20 0.009064641 5865.64 0.009086065 5868.08 0.009099951 5870.52 0.009034649 5872.97 0.009090183 5875.41 0.009129985 5877.85 0.009127294 5880.30 0.009150904 5882.74 0.009134864 5885.18 0.009148735 5887.63 0.009247581 5890.07 0.00919535 5892.51 0.009185172 5894.95 0.009189202 5897.40 0.009158602 5899.84 0.009220537 5902.28 0.009259667 5904.73 0.009333839 5907.17 0.009350002 5909.61 0.009382596 5912.06 0.00938142 5914.50 0.009386023 5916.94 0.009445796 5919.38 0.009487838 5921.83 0.009516341 5924.27 0.009589158 5926.71 0.009581988 5929.16 0.009601414 5931.60 0.009672232 5934.04 0.009716547 5936.49 0.009709159 5938.93 0.009718437 5941.37 0.00974078 5943.81 0.009729223 5946.26 0.009767237 5948.70 0.009883033 5951.14 0.009915131 5953.59 0.009890378 5956.03 0.009939048 5958.47 0.009973032 5960.92 0.01003236 5963.36 0.01007763 5965.80 0.01012036 5968.24 0.01014008 5970.69 0.01014879 5973.13 0.01021011 5975.57 0.01021916 5978.02 0.01025372 5980.46 0.01033774 5982.90 0.01038624 5985.35 0.01038744 5987.79 0.01043099 5990.23 0.01049909 5992.67 0.01051897 5995.12 0.01066393 5997.56 0.01089606 6000.00 0.01077813 6002.45 0.01062231 6004.89 0.01072646 6007.33 0.01078348 6009.78 0.01080175 6012.22 0.01082761 6014.66 0.01089923 6017.10 0.0109586 6019.55 0.01097754 6021.99 0.01102526 6024.43 0.01107217 6026.88 0.01112797 6029.32 0.01119492 6031.76 0.01120983 6034.21 0.01123047 6036.65 0.01125898 6039.09 0.01126249 6041.53 0.01128456 6043.98 0.01132577 6046.42 0.01137306 6048.86 0.01142674 6051.31 0.01148246 6053.75 0.01157473 6056.19 0.01159056 6058.64 0.01163471 6061.08 0.01165071 6063.52 0.01168417 6065.96 0.01170239 6068.41 0.01178129 6070.85 0.01182451 6073.29 0.01184083 6075.74 0.01192577 6078.18 0.01195752 6080.62 0.01196407 6083.07 0.01206297 6085.51 0.01216625 6087.95 0.01211657 6090.39 0.01211284 6092.84 0.01221272 6095.28 0.01230593 6097.72 0.01239798 6100.17 0.01242134 6102.61 0.01239608 6105.05 0.01242992 6107.50 0.01254783 6109.94 0.01261115 6112.38 0.0126387 6114.82 0.01271979 6117.27 0.01274981 6119.71 0.01281338 6122.15 0.01284606 6124.60 0.01290745 6127.04 0.0129215 6129.48 0.01296082 6131.93 0.01296966 6134.37 0.01306475 6136.81 0.01320045 6139.25 0.0132974 6141.70 0.01336747 6144.14 0.01339556 6146.58 0.01341144 6149.03 0.01353664 6151.47 0.01361514 6153.91 0.01375803 6156.36 0.01388721 6158.80 0.01440389 6161.24 0.01762235 6163.68 0.02257267 6166.13 0.02214516 6168.57 0.01759097 6171.01 0.01533226 6173.46 0.01462387 6175.90 0.01449434 6178.34 0.01457892 6180.79 0.01478664 6183.23 0.01480147 6185.67 0.01484601 6188.11 0.01495168 6190.56 0.01502614 6193.00 0.01510475 6195.44 0.01530943 6197.89 0.01552448 6200.33 0.01554556 6202.77 0.01562605 6205.22 0.01577463 6207.66 0.01596852 6210.10 0.01609718 6212.54 0.01621112 6214.99 0.01637441 6217.43 0.016559 6219.87 0.01670325 6222.32 0.01684406 6224.76 0.01700563 6227.20 0.0172478 6229.65 0.01744673 6232.09 0.017516 6234.53 0.01772147 6236.97 0.01790451 6239.42 0.01809399 6241.86 0.01832406 6244.30 0.01853928 6246.75 0.01874606 6249.19 0.01904173 6251.63 0.0192112 6254.08 0.01953913 6256.52 0.01981187 6258.96 0.02001161 6261.40 0.02030995 6263.85 0.02047984 6266.29 0.02068377 6268.73 0.02094049 6271.18 0.02119097 6273.62 0.021501 6276.06 0.02184145 6278.51 0.02209963 6280.95 0.02249371 6283.39 0.02285624 6285.83 0.02315166 6288.28 0.02346732 6290.72 0.02382713 6293.16 0.02411941 6295.61 0.02446754 6298.05 0.02495244 6300.49 0.02531964 6302.94 0.02566791 6305.38 0.02609939 6307.82 0.02659116 6310.26 0.02690953 6312.71 0.02740098 6315.15 0.02795384 6317.59 0.02842585 6320.04 0.02887311 6322.48 0.0292614 6324.92 0.02981661 6327.37 0.0304139 6329.81 0.03090229 6332.25 0.03141537 6334.69 0.03198354 6337.14 0.03253982 6339.58 0.0330529 6342.02 0.03379775 6344.47 0.03450875 6346.91 0.03511313 6349.35 0.03571809 6351.80 0.03635197 6354.24 0.03698314 6356.68 0.03772592 6359.12 0.03838501 6361.57 0.03900982 6364.01 0.03976556 6366.45 0.04052 6368.90 0.04132381 6371.34 0.042082 6373.78 0.04293953 6376.23 0.04377063 6378.67 0.04444651 6381.11 0.04516367 6383.55 0.04599402 6386.00 0.04689446 6388.44 0.04761498 6390.88 0.04850501 6393.33 0.04942127 6395.77 0.05014232 6398.21 0.05105599 6400.66 0.05196429 6403.10 0.05288282 6405.54 0.05372643 6407.98 0.05469457 6410.43 0.05568931 6412.87 0.05655721 6415.31 0.05745123 6417.76 0.05840904 6420.20 0.05929194 6422.64 0.0602578 6425.09 0.0613305 6427.53 0.06223429 6429.97 0.06302916 6432.41 0.06396457 6434.86 0.0650426 6437.30 0.06605671 6439.74 0.06702644 6442.19 0.06789407 6444.63 0.06869575 6447.07 0.06968818 6449.52 0.07074357 6451.96 0.07169676 6454.40 0.0727416 6456.84 0.07382081 6459.29 0.0748444 6461.73 0.07563956 6464.17 0.07642608 6466.62 0.07773969 6469.06 0.07881533 6471.50 0.07962348 6473.95 0.08042501 6476.39 0.08141274 6478.83 0.08223792 6481.27 0.08303384 6483.72 0.08402152 6486.16 0.08501609 6488.60 0.08598848 6491.05 0.08690669 6493.49 0.08777164 6495.93 0.08871575 6498.38 0.08957025 6500.82 0.09040038 6503.26 0.09134655 6505.70 0.09214098 6508.15 0.09321181 6510.59 0.0942819 6513.03 0.0950091 6515.48 0.09583945 6517.92 0.09662207 6520.36 0.09770891 6522.81 0.09858327 6525.25 0.09953339 6527.69 0.1005786 6530.13 0.1013591 6532.58 0.1022045 6535.02 0.1030384 6537.46 0.1039029 6539.91 0.1049359 6542.35 0.1060809 6544.79 0.1068863 6547.24 0.1076561 6549.68 0.1086562 6552.12 0.109716 6554.56 0.1108269 6557.01 0.1119051 6559.45 0.1129056 6561.89 0.1138989 6564.34 0.1150065 6566.78 0.1161785 6569.22 0.1173179 6571.67 0.1183616 6574.11 0.1192092 6576.55 0.1204853 6578.99 0.1219119 6581.44 0.1228843 6583.88 0.1240556 6586.32 0.1253365 6588.77 0.1264879 6591.21 0.1278953 6593.65 0.1292482 6596.10 0.1306189 6598.54 0.1321281 6600.98 0.1332983 6603.42 0.1346767 6605.87 0.1363637 6608.31 0.1380187 6610.75 0.139599 6613.20 0.1411096 6615.64 0.1427787 6618.08 0.1445174 6620.53 0.1463314 6622.97 0.1481674 6625.41 0.1498782 6627.85 0.1514547 6630.30 0.1534353 6632.74 0.155658 6635.18 0.1574737 6637.63 0.1594411 6640.07 0.1617194 6642.51 0.1639099 6644.96 0.1660965 6647.40 0.1684433 6649.84 0.1705509 6652.28 0.1729315 6654.73 0.1757077 6657.17 0.1781943 6659.61 0.1807097 6662.06 0.1832475 6664.50 0.1861363 6666.94 0.1889827 6669.39 0.1916789 6671.83 0.1947431 6674.27 0.1978436 6676.71 0.200856 6679.16 0.2042421 6681.60 0.2075281 6684.04 0.2106412 6686.49 0.2141801 6688.93 0.217796 6691.37 0.2215365 6693.82 0.2251554 6696.26 0.229016 6698.70 0.2329623 6701.14 0.2369167 6703.59 0.2409904 6706.03 0.2451846 6708.47 0.2497483 6710.92 0.2540753 6713.36 0.2585702 6715.80 0.263033 6718.25 0.2678648 6720.69 0.2728259 6723.13 0.2776992 6725.57 0.2830855 6728.02 0.2883238 6730.46 0.2935684 6732.90 0.299191 6735.35 0.3047683 6737.79 0.3100987 6740.23 0.3161822 6742.68 0.3222274 6745.12 0.328452 6747.56 0.3346154 6750.00 0.3410876 6752.45 0.3474432 6754.89 0.3539833 6757.33 0.3604566 6759.78 0.3672964 6762.22 0.3742144 6764.66 0.3816684 6767.11 0.3894242 6769.55 0.3968921 6771.99 0.4040856 6774.43 0.4116572 6776.88 0.4197605 6779.32 0.427555 6781.76 0.4358322 6784.21 0.4438027 6786.65 0.4520275 6789.09 0.4600525 6791.54 0.4686632 6793.98 0.4771259 6796.42 0.4855084 6798.86 0.4945332 6801.31 0.5037774 6803.75 0.512679 6806.19 0.5216042 6808.64 0.5303103 6811.08 0.5393445 6813.52 0.5484006 6815.97 0.557525 6818.41 0.5667889 6820.85 0.5761672 6823.29 0.5853643 6825.74 0.5942352 6828.18 0.6035799 6830.62 0.6129008 6833.07 0.6218711 6835.51 0.6311503 6837.95 0.6404543 6840.40 0.6495863 6842.84 0.6586865 6845.28 0.667475 6847.72 0.6763475 6850.17 0.6853666 6852.61 0.6937143 6855.05 0.7019662 6857.50 0.7105371 6859.94 0.7186366 6862.38 0.7268521 6864.83 0.7352697 6867.27 0.7427573 6869.71 0.7503313 6872.15 0.7583711 6874.60 0.7655941 6877.04 0.7722911 6879.48 0.7790502 6881.93 0.786391 6884.37 0.7937549 6886.81 0.7997698 6889.26 0.8053677 6891.70 0.8117202 6894.14 0.8171805 6896.58 0.8224778 6899.03 0.8283097 6901.47 0.8333946 6903.91 0.8384199 6906.36 0.8433797 6908.80 0.847465 6911.24 0.8512153 6913.69 0.855422 6916.13 0.8595848 6918.57 0.8634329 6921.01 0.8673989 6923.46 0.8703448 6925.90 0.8728281 6928.34 0.8760435 6930.79 0.8791839 6933.23 0.8823789 6935.67 0.8842 6938.12 0.8860637 6940.56 0.8877953 6943.00 0.8897997 6945.44 0.8919861 6947.89 0.8937072 6950.33 0.8945931 6952.77 0.8961396 6955.22 0.8973135 6957.66 0.8983834 6960.10 0.8990601 6962.55 0.89986 6964.99 0.9006405 6967.43 0.9015372 6969.88 0.9016537 6972.32 0.9018239 6974.76 0.9024901 6977.20 0.9031445 6979.65 0.9035589 6982.09 0.9032316 6984.53 0.9033133 6986.98 0.9032319 6989.42 0.9033238 6991.86 0.9032682 6994.31 0.903101 6996.75 0.9030662 6999.19 0.9025477 7001.63 0.9023978 7004.08 0.9024088 7006.52 0.9018698 7008.96 0.9012806 7011.41 0.9012842 7013.85 0.9013679 7016.29 0.9009836 7018.74 0.9000501 7021.18 0.8997639 7023.62 0.8996516 7026.06 0.8986333 7028.51 0.8981212 7030.95 0.8985255 7033.39 0.8979149 7035.84 0.8972446 7038.28 0.8971444 7040.72 0.8968325 7043.17 0.8965823 7045.61 0.8966088 7048.05 0.8966725 7050.49 0.8960559 7052.94 0.8951648 7055.38 0.8949975 7057.82 0.895463 7060.27 0.8949779 7062.71 0.8943963 7065.15 0.8942305 7067.60 0.8941621 7070.04 0.8934051 7072.48 0.893173 7074.92 0.893548 7077.37 0.8930869 7079.81 0.8926312 7082.25 0.8927323 7084.70 0.8924481 7087.14 0.8919966 7089.58 0.8917124 7092.03 0.891848 7094.47 0.8921466 7096.91 0.8921163 7099.35 0.8916416 7101.80 0.8919013 7104.24 0.8917236 7106.68 0.891181 7109.13 0.8912398 7111.57 0.8913187 7114.01 0.8909575 7116.46 0.8908464 7118.90 0.8913862 7121.34 0.8911279 7123.78 0.890794 7126.23 0.8908354 7128.67 0.8906789 7131.11 0.891297 7133.56 0.8913369 7136.00 0.890436 7138.44 0.8908429 7140.89 0.8904755 7143.33 0.890354 7145.77 0.8903463 7148.21 0.8906129 7150.66 0.8903044 7153.10 0.890465 7155.54 0.8903053 7157.99 0.8904302 7160.43 0.8902437 7162.87 0.8899206 7165.32 0.8905492 7167.76 0.8906879 7170.20 0.8903376 7172.64 0.8897005 7175.09 0.8893473 7177.53 0.8896143 7179.97 0.8894382 7182.42 0.8888049 7184.86 0.8887582 7187.30 0.8884494 7189.75 0.8887675 7192.19 0.8891234 7194.63 0.888599 7197.07 0.8882568 7199.52 0.888045 7201.96 0.8877765 7204.40 0.8875972 7206.85 0.8873457 7209.29 0.8874545 7211.73 0.8871782 7214.18 0.8864105 7216.62 0.8864409 7219.06 0.8862895 7221.50 0.886037 7223.95 0.8861917 7226.39 0.8856551 7228.83 0.8848637 7231.28 0.8845964 7233.72 0.8845133 7236.16 0.8843368 7238.61 0.8843802 7241.05 0.8843925 7243.49 0.8841588 7245.93 0.8836133 7248.38 0.8831335 7250.82 0.8830789 7253.26 0.8828117 7255.71 0.882008 7258.15 0.8816856 7260.59 0.8817287 7263.04 0.881481 7265.48 0.881079 7267.92 0.8807155 7270.36 0.8806825 7272.81 0.8808392 7275.25 0.8806114 7277.69 0.8801211 7280.14 0.8793696 7282.58 0.879207 7285.02 0.879178 7287.47 0.8786014 7289.91 0.8784015 7292.35 0.8778992 7294.79 0.8775309 7297.24 0.8776295 7299.68 0.8773955 7302.12 0.8765122 7304.57 0.8766893 7307.01 0.8758462 7309.45 0.8753742 7311.90 0.875152 7314.34 0.8748083 7316.78 0.8742858 7319.22 0.8743341 7321.67 0.8747597 7324.11 0.8744395 7326.55 0.8740889 7329.00 0.873769 7331.44 0.8734721 7333.88 0.8731762 7336.33 0.8732671 7338.77 0.8731306 7341.21 0.872754 7343.65 0.8725525 7346.10 0.8724575 7348.54 0.8718203 7350.98 0.8719514 7353.43 0.8717798 7355.87 0.871627 7358.31 0.8718927 7360.76 0.8718871 7363.20 0.8714215 7365.64 0.871502 7368.08 0.8716357 7370.53 0.8712817 7372.97 0.8713461 7375.41 0.8713482 7377.86 0.8712859 7380.30 0.8709957 7382.74 0.8707605 7385.19 0.8712911 7387.63 0.8716714 7390.07 0.8714385 7392.51 0.8713961 7394.96 0.8714938 7397.40 0.8713257 7399.84 0.871743 7402.29 0.8720798 7404.73 0.8719752 7407.17 0.8721169 7409.62 0.871873 7412.06 0.8720745 7414.50 0.8721337 7416.94 0.8720258 7419.39 0.8725105 7421.83 0.8722476 7424.27 0.8723749 7426.72 0.872436 7429.16 0.8723949 7431.60 0.8730822 7434.05 0.8738081 7436.49 0.8735096 7438.93 0.8731371 7441.37 0.8734269 7443.82 0.8740509 7446.26 0.8741574 7448.70 0.874084 7451.15 0.8748719 7453.59 0.8753123 7456.03 0.8755618 7458.48 0.8755769 7460.92 0.875969 7463.36 0.875849 7465.80 0.8762234 7468.25 0.8766883 7470.69 0.8772327 7473.13 0.8770933 7475.58 0.8771948 7478.02 0.8774914 7480.46 0.877721 7482.91 0.8783752 7485.35 0.8790429 7487.79 0.8797265 7490.23 0.8800033 7492.68 0.8794521 7495.12 0.8795087 7497.56 0.8798366 7500.01 0.8798547 7502.45 0.8804126 7504.89 0.8810802 7507.34 0.8812184 7509.78 0.8809082 7512.22 0.881506 7514.66 0.8821709 7517.11 0.8822827 7519.55 0.8823124 7521.99 0.8830594 7524.44 0.8831402 7526.88 0.8831557 7529.32 0.8835397 7531.77 0.8834236 7534.21 0.8836275 7536.65 0.8837404 7539.09 0.8842705 7541.54 0.8848015 7543.98 0.8850365 7546.42 0.885291 7548.87 0.88528 7551.31 0.8857489 7553.75 0.8863422 7556.20 0.8863171 7558.64 0.8860217 7561.08 0.8862472 7563.52 0.8870897 7565.97 0.8876249 7568.41 0.8875194 7570.85 0.8874853 7573.30 0.8876872 7575.74 0.8880838 7578.18 0.8879873 7580.63 0.8876366 7583.07 0.888065 7585.51 0.8883084 7587.95 0.8886229 7590.40 0.8890125 7592.84 0.8891934 7595.28 0.8894989 7597.73 0.8895628 7600.17 0.8898441 7602.61 0.8897216 7605.06 0.8897301 7607.50 0.8904476 7609.94 0.8907251 7612.38 0.8911109 7614.83 0.890847 7617.27 0.8905238 7619.71 0.8907492 7622.16 0.8915786 7624.60 0.8915283 7627.04 0.891866 7629.49 0.8911338 7631.93 0.89129 7634.37 0.8913266 7636.81 0.8914431 7639.26 0.8914813 7641.70 0.8911998 7644.14 0.8909529 7646.59 0.8916478 7649.03 0.8920658 7651.47 0.8918665 7653.92 0.8921868 7656.36 0.8930345 7658.80 0.893135 7661.24 0.8931122 7663.69 0.8922254 7666.13 0.8918175 7668.57 0.8917153 7671.02 0.8922232 7673.46 0.8927028 7675.90 0.8928652 7678.35 0.8931009 7680.79 0.8931111 7683.23 0.8927451 7685.67 0.8924158 7688.12 0.892355 7690.56 0.8924935 7693.00 0.8929332 7695.45 0.8931047 7697.89 0.8929809 7700.33 0.8928648 7702.78 0.8931854 7705.22 0.8935453 7707.66 0.8932929 7710.10 0.8932242 7712.55 0.8935605 7714.99 0.8931571 7717.43 0.8933641 7719.88 0.8931879 7722.32 0.8924665 7724.76 0.8929523 7727.21 0.8931612 7729.65 0.8933781 7732.09 0.8937604 7734.53 0.8930994 7736.98 0.8927905 7739.42 0.892798 7741.86 0.8927533 7744.31 0.8935206 7746.75 0.8934225 7749.19 0.8928401 7751.64 0.8929526 7754.08 0.8936114 7756.52 0.8941047 7758.96 0.8936126 7761.41 0.8931397 7763.85 0.8928142 7766.29 0.8929327 7768.74 0.8923597 7771.18 0.8925706 7773.62 0.8931119 7776.07 0.8932028 7778.51 0.8928378 7780.95 0.8929201 7783.39 0.893638 7785.84 0.8941837 7788.28 0.8944604 7790.72 0.8943152 7793.17 0.8942533 7795.61 0.8941209 7798.05 0.8940759 7800.50 0.8940582 7802.94 0.8936599 7805.38 0.8935194 7807.82 0.8934149 7810.27 0.8928515 7812.71 0.8937334 7815.15 0.8933253 7817.60 0.8931468 7820.04 0.8934519 7822.48 0.8942817 7824.93 0.8946965 7827.37 0.8942962 7829.81 0.894769 7832.25 0.8942071 7834.70 0.894289 7837.14 0.8946054 7839.58 0.8944624 7842.03 0.8950683 7844.47 0.8955423 7846.91 0.895881 7849.36 0.896603 7851.80 0.8961762 7854.24 0.8954926 7856.68 0.8961281 7859.13 0.8960449 7861.57 0.8954868 7864.01 0.8952988 7866.46 0.8954266 7868.90 0.8957508 7871.34 0.8962867 7873.79 0.8963378 7876.23 0.8962546 7878.67 0.8965265 7881.11 0.8973199 7883.56 0.8977504 7886.00 0.89782 7888.44 0.8979961 7890.89 0.8977612 7893.33 0.8972107 7895.77 0.8975715 7898.22 0.8978946 7900.66 0.897846 7903.10 0.8978776 7905.54 0.8973289 7907.99 0.8978698 7910.43 0.8987105 7912.87 0.898719 7915.32 0.8985381 7917.76 0.8980944 7920.20 0.898254 7922.65 0.8984622 7925.09 0.8984718 7927.53 0.8986193 7929.97 0.8989821 7932.42 0.8993763 7934.86 0.8991066 7937.30 0.899245 7939.75 0.8998584 7942.19 0.9003986 7944.63 0.9006608 7947.08 0.9010609 7949.52 0.9014075 7951.96 0.9012893 7954.40 0.9010933 7956.85 0.900644 7959.29 0.9000549 7961.73 0.8999079 7964.18 0.9002483 7966.62 0.9008477 7969.06 0.9010244 7971.51 0.9006478 7973.95 0.9004537 7976.39 0.9004061 7978.83 0.9007999 7981.28 0.9003771 7983.72 0.9010919 7986.16 0.9015252 7988.61 0.901143 7991.05 0.9007295 7993.49 0.900912 7995.94 0.9010876 7998.38 0.9011773 8000.82 0.9005172 8003.26 0.9001399 8005.71 0.9004625 8008.15 0.9003643 8010.59 0.8996876 8013.04 0.9002511 8015.48 0.8998514 8017.92 0.900111 8020.37 0.9011399 8022.81 0.9016504 8025.25 0.9014206 8027.69 0.9004917 8030.14 0.9010311 8032.58 0.901915 8035.02 0.9016128 8037.47 0.9017046 8039.91 0.9008398 8042.35 0.9005988 8044.80 0.9008505 8047.24 0.9009708 8049.68 0.9001534 8052.12 0.8991928 8054.57 0.8994993 8057.01 0.8999915 8059.45 0.9002426 8061.90 0.8996276 8064.34 0.8993427 8066.78 0.8989841 8069.23 0.8984985 8071.67 0.8982655 8074.11 0.8988664 8076.55 0.8998635 8079.00 0.9001181 8081.44 0.8992608 8083.88 0.8993847 8086.33 0.8997911 8088.77 0.8991418 8091.21 0.8985259 8093.66 0.8979116 8096.10 0.8972952 8098.54 0.8966754 8100.98 0.8962901 8103.43 0.8964313 8105.87 0.8963226 8108.31 0.8962302 8110.76 0.8961718 8113.20 0.8963856 8115.64 0.8972398 8118.09 0.8974074 8120.53 0.8970287 8122.97 0.8965852 8125.41 0.8961754 8127.86 0.8949906 8130.30 0.8938518 8132.74 0.8936091 8135.19 0.8935539 8137.63 0.8935415 8140.07 0.8934731 8142.52 0.8939139 8144.96 0.8939349 8147.40 0.8936605 8149.84 0.8935719 8152.29 0.8928868 8154.73 0.8924311 8157.17 0.8921935 8159.62 0.8922704 8162.06 0.8920833 8164.50 0.8913768 8166.95 0.890648 8169.39 0.8902928 8171.83 0.8898463 8174.27 0.8899482 8176.72 0.8902202 8179.16 0.8896046 8181.60 0.8892931 8184.05 0.8890373 8186.49 0.8889073 8188.93 0.8883685 8191.38 0.8888468 8193.82 0.8887987 8196.26 0.8880689 8198.71 0.8879262 8201.15 0.8875742 8203.59 0.8865083 8206.03 0.8861713 8208.48 0.8856439 8210.92 0.8857207 8213.36 0.8852621 8215.81 0.8846977 8218.25 0.8845757 8220.69 0.8847463 8223.14 0.8845589 8225.58 0.8853011 8228.02 0.8856761 8230.46 0.8849078 8232.91 0.8852465 8235.35 0.8853797 8237.79 0.8855935 8240.24 0.885281 8242.68 0.8849564 8245.12 0.8847489 8247.57 0.8847542 8250.01 0.8844132 8252.45 0.8836005 8254.89 0.8825685 8257.34 0.8819789 8259.78 0.8808877 8262.22 0.8802401 8264.67 0.8804649 8267.11 0.879896 8269.55 0.8798311 8272.00 0.8802319 8274.44 0.8800348 8276.88 0.8796663 8279.32 0.8798992 8281.77 0.8807751 8284.21 0.8813646 8286.65 0.8806855 8289.10 0.8796772 8291.54 0.8797754 8293.98 0.8804866 8296.43 0.880533 8298.87 0.8795716 8301.31 0.8788385 8303.75 0.8785939 8306.20 0.8782684 8308.64 0.87797 8311.08 0.8774877 8313.53 0.8768043 8315.97 0.8765965 8318.41 0.8769603 8320.86 0.8780469 8323.30 0.8789665 8325.74 0.8788905 8328.18 0.878556 8330.63 0.8784885 8333.07 0.8786789 8335.51 0.8788368 8337.96 0.8787201 8340.40 0.8779193 8342.84 0.8766705 8345.29 0.8760875 8347.73 0.8763835 8350.17 0.8758481 8352.61 0.8759656 8355.06 0.8773026 8357.50 0.8780728 8359.94 0.8788926 8362.39 0.8790768 8364.83 0.8796971 8367.27 0.8797381 8369.72 0.8793329 8372.16 0.8792263 8374.60 0.8792945 8377.04 0.878049 8379.49 0.8778266 8381.93 0.8768908 8384.37 0.8754119 8386.82 0.8747734 8389.26 0.8747951 8391.70 0.8746879 8394.15 0.8753948 8396.59 0.8765916 8399.03 0.8773286 8401.47 0.8782097 8403.92 0.8784564 8406.36 0.8785323 8408.80 0.8786286 8411.25 0.8778294 8413.69 0.8764206 8416.13 0.8755891 8418.58 0.8762643 8421.02 0.8774466 8423.46 0.8782455 8425.90 0.8785236 8428.35 0.878895 8430.79 0.8790866 8433.23 0.8782522 8435.68 0.8777033 8438.12 0.8779924 8440.56 0.8778323 8443.01 0.8785396 8445.45 0.8787596 8447.89 0.8786125 8450.33 0.8786283 8452.78 0.8780571 8455.22 0.8780738 8457.66 0.8777533 8460.11 0.8780562 8462.55 0.8787087 8464.99 0.8785465 8467.44 0.8783842 8469.88 0.878879 8472.32 0.8790004 8474.76 0.8785276 8477.21 0.8780335 8479.65 0.8777978 8482.09 0.8784838 8484.54 0.8794378 8486.98 0.8801937 8489.42 0.8808224 8491.87 0.8804435 8494.31 0.8808069 8496.75 0.8815793 8499.19 0.8810583 8501.64 0.8815516 8504.08 0.8825531 8506.52 0.8824951 8508.97 0.8828541 8511.41 0.8833906 8513.85 0.8833494 8516.30 0.8838372 8518.74 0.884214 8521.18 0.8840677 8523.62 0.883942 8526.07 0.8836172 8528.51 0.8830726 8530.95 0.8817137 8533.40 0.8797445 8535.84 0.878534 8538.28 0.8787294 8540.73 0.8789018 8543.17 0.8798636 8545.61 0.8810539 8548.05 0.8814483 8550.50 0.8824373 8552.94 0.8825703 8555.38 0.8815101 8557.83 0.8810422 8560.27 0.8796421 8562.71 0.8798026 8565.16 0.8803856 8567.60 0.8809053 8570.04 0.8818761 8572.48 0.8834855 8574.93 0.8839594 8577.37 0.8844839 8579.81 0.8841732 8582.26 0.8835282 8584.70 0.8817782 8587.14 0.8807496 8589.59 0.8807203 8592.03 0.8803078 8594.47 0.879981 8596.91 0.8805192 8599.36 0.8813176 8601.80 0.881438 8604.24 0.8824168 8606.69 0.8835215 8609.13 0.8832858 8611.57 0.8834214 8614.02 0.8844934 8616.46 0.8839632 8618.90 0.8835461 8621.34 0.8833181 8623.79 0.8830275 8626.23 0.8836128 8628.67 0.8827513 8631.12 0.8817843 8633.56 0.881356 8636.00 0.8815584 8638.45 0.880807 8640.89 0.8811129 8643.33 0.8807771 8645.77 0.8802477 8648.22 0.8809827 8650.66 0.8807299 8653.10 0.8802082 8655.55 0.8803471 8657.99 0.8805971 8660.43 0.880407 8662.88 0.8805116 8665.32 0.8810893 8667.76 0.8811501 8670.20 0.8815209 8672.65 0.8816336 8675.09 0.8816487 8677.53 0.881403 8679.98 0.8811021 8682.42 0.881036 8684.86 0.8805894 8687.31 0.8808332 8689.75 0.8807576 8692.19 0.8808526 8694.63 0.88064 8697.08 0.8802129 8699.52 0.8804632 8701.96 0.8809959 8704.41 0.8809147 8706.85 0.8807971 8709.29 0.8804711 8711.74 0.8799514 8714.18 0.8794602 8716.62 0.8794614 8719.06 0.8800502 8721.51 0.8801514 8723.95 0.8791668 8726.39 0.8789647 8728.84 0.8800401 8731.28 0.8805439 8733.72 0.8804452 8736.17 0.8804791 8738.61 0.8807114 8741.05 0.8807405 8743.49 0.8810099 8745.94 0.8812134 8748.38 0.8804716 8750.82 0.8801185 8753.27 0.8801441 8755.71 0.8790246 8758.15 0.8785592 8760.60 0.8792397 8763.04 0.8794867 8765.48 0.8796278 8767.92 0.8794151 8770.37 0.879124 8772.81 0.8797637 8775.25 0.8798832 8777.70 0.8785383 8780.14 0.877486 8782.58 0.8775255 8785.03 0.8777494 8787.47 0.8771608 8789.91 0.8765833 8792.35 0.8769525 8794.80 0.8763809 8797.24 0.8767102 8799.68 0.8767303 8802.13 0.8765177 8804.57 0.8765112 8807.01 0.8768331 8809.46 0.8769325 8811.90 0.877434 8814.34 0.8781847 8816.78 0.8780223 8819.23 0.8775653 8821.67 0.8772258 8824.11 0.8771502 8826.56 0.8763651 8829.00 0.8757352 8831.44 0.8749622 8833.89 0.8749485 8836.33 0.8742749 8838.77 0.8734752 8841.21 0.8737353 8843.66 0.874276 8846.10 0.8737825 8848.54 0.8742417 8850.99 0.8741891 8853.43 0.8741378 8855.87 0.8741544 8858.32 0.8739166 8860.76 0.8739361 8863.20 0.8735756 8865.64 0.8738106