SetReadModeNormal

Bases: KPFFunction

Configure both detectors to normal read mode by changing the ACF files they are using.

KTL Keywords Used:

  • kpfgreen.ACFFILE
  • kpfgreen.ACF
  • kpfred.ACFFILE
  • kpfred.ACF

Functions Called:

  • kpf.spectrograph.QueryReadMode
  • kpf.utils.SendEmail
Source code in kpf/spectrograph/SetReadModeNormal.py
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
class SetReadModeNormal(KPFFunction):
    '''Configure both detectors to normal read mode by changing the ACF files
    they are using.

    KTL Keywords Used:

    - `kpfgreen.ACFFILE`
    - `kpfgreen.ACF`
    - `kpfred.ACFFILE`
    - `kpfred.ACF`

    Functions Called:

    - `kpf.spectrograph.QueryReadMode`
    - `kpf.utils.SendEmail`
    '''
    @classmethod
    def pre_condition(cls, args):
        pass

    @classmethod
    def perform(cls, args):
        green_mode, red_mode = QueryReadMode.execute({})
        if green_mode != 'normal':
            msg = f'Setting Green CCD read mode normal'
            log.info(msg)
            # Email to kpf_info
            try:
                SendEmail.execute({'Subject': msg, 'Message': msg})
            except Exception as email_err:
                log.error(f'Sending email failed')
                log.error(email_err)
            kpfgreen = ktl.cache('kpfgreen')
            green_normal_file = cfg.get('acf_files', 'green_normal')
            green_ACFFILE = Path(kpfgreen['ACFFILE'].read()).stem
            if green_ACFFILE != green_normal_file:
                kpfgreen['ACF'].write(green_normal_file)
            time.sleep(1)
        if red_mode != 'normal':
            msg = f'Setting Red CCD read mode normal'
            log.info(msg)
            # Email to kpf_info
            try:
                SendEmail.execute({'Subject': msg, 'Message': msg})
            except Exception as email_err:
                log.error(f'Sending email failed')
                log.error(email_err)
            kpfred = ktl.cache('kpfred')
            red_normal_file = cfg.get('acf_files', 'red_normal')
            red_ACFFILE = Path(kpfred['ACFFILE'].read()).stem
            if red_ACFFILE != red_normal_file:
                kpfred['ACF'].write(red_normal_file)
            time.sleep(1)

    @classmethod
    def post_condition(cls, args):
        green_mode, red_mode = QueryReadMode.execute({})
        if green_mode != "normal":
            raise FailedToReachDestination(green_mode, "normal")
        if red_mode != "normal":
            raise FailedToReachDestination(red_mode, "normal")