SetOutdirs

Bases: KPFFunction

Set output directories for all detectors based on the current date.

Source code in kpf/utils/SetOutdirs.py
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
class SetOutdirs(KPFFunction):
    '''Set output directories for all detectors based on the current date.
    '''
    @classmethod
    def pre_condition(cls, args):
        pass

    @classmethod
    def perform(cls, args):
        log.info(f"SetOutdirs invoked")
        utnow = datetime.utcnow()
        date = utnow-timedelta(days=1)
        date_str = date.strftime('%Y%b%d').lower()
        outdir = Path(f"/s/sdata1701/{os.getlogin()}/{date_str}")
        magiq_outdir = Path(f"/s/sdata1701/kpfguide/{date_str}")
        log.debug(f"base outdir: {outdir}")
        log.debug(f"magiq outdir: {magiq_outdir}")

        if args.get('CRED2', True) is True:
            log.info(f"  Guider OUTDIR = {magiq_outdir}")
            guide_outdir = ktl.cache('kpfguide', 'OUTDIR')
            try:
                guide_outdir.write(f"{magiq_outdir}")
            except Exception as e:
                log.error(f"ERROR setting guider outdir")
                log.error(e)

            log.info(f"  Guider TRIGOUTDIR = {outdir / 'CRED2'}")
            trig_outdir = ktl.cache('kpfguide', 'TRIGOUTDIR')
            try:
                trig_outdir.write(f"{outdir / 'CRED2'}")
            except Exception as e:
                log.error(f"ERROR setting guider TRIGOUTDIR")
                log.error(e)

        kpffvc = ktl.cache('kpffvc')
        if args.get('FVC1', False) is True:
            log.info(f"  FVC1 OUTDIR = {outdir / 'FVC1'}")
            try:
                kpffvc['SCIOUTDIR'].write(f"{outdir / 'FVC1'}")
            except Exception as e:
                log.error(f"ERROR setting SCI FVC outdir")
                log.error(e)

        if args.get('FVC2', False) is True:
            log.info(f"  FVC2 OUTDIR = {outdir / 'FVC2'}")
            try:
                kpffvc['CAHKOUTDIR'].write(f"{outdir / 'FVC2'}")
            except Exception as e:
                log.error(f"ERROR setting CAHK FVC outdir")
                log.error(e)

        if args.get('FVC3', False) is True:
            log.info(f"  FVC3 OUTDIR = {outdir / 'FVC3'}")
            try:
                kpffvc['CALOUTDIR'].write(f"{outdir / 'FVC3'}")
            except Exception as e:
                log.error(f"ERROR setting CAL FVC outdir")
                log.error(e)

        if args.get('FVC4', False) is True:
            log.info(f"  FVC4 OUTDIR = {outdir / 'FVC4'}")
            try:
                kpffvc['EXTOUTDIR'].write(f"{outdir / 'FVC4'}")
            except Exception as e:
                log.error(f"ERROR setting EXT FVC outdir")
                log.error(e)

        if args.get('ExpMeter', True) is True:
            expmeter_outdir = outdir / 'ExpMeter'
            log.info(f"  ExpMeter DATADIR = {expmeter_outdir}")
            kpf_expmeter_outdir = ktl.cache('kpf_expmeter', 'DATADIR')
            try:
                kpf_expmeter_outdir.write(f"{expmeter_outdir}")
            except Exception as e:
                log.error(f"ERROR setting ExpMeter outdir")
                log.error(e)

        if args.get('CaHK', True) is True:
            cahk_outdir = outdir / 'CaHK'
            log.info(f"  CaHK RECORDDIR = {cahk_outdir}")
            kpf_hk_outdir = ktl.cache('kpf_hk', 'RECORDDIR')
            try:
                kpf_hk_outdir.write(f"{cahk_outdir}")
            except Exception as e:
                log.error(f"ERROR setting CaHK outdir")
                log.error(e)

        if args.get('Green', True) is True:
            green_outdir = outdir / 'Green'
            log.info(f"  Green FITSDIR = {green_outdir}")
            kpfgreen_outdir = ktl.cache('kpfgreen', 'FITSDIR')
            try:
                kpfgreen_outdir.write(f"{green_outdir}")
            except Exception as e:
                log.error(f"ERROR setting Green outdir")
                log.error(e)

        if args.get('Red', True) is True:
            red_outdir = outdir / 'Red'
            log.info(f"  Red FITSDIR = {red_outdir}")
            kpfred_outdir = ktl.cache('kpfred', 'FITSDIR')
            try:
                kpfred_outdir.write(f"{red_outdir}")
            except Exception as e:
                log.error(f"ERROR setting Red outdir")
                log.error(e)

        if args.get('L0', True) is True:
            L0_outdir = outdir / 'L0'
            log.info(f"  kpfasemble OUTDIR = {L0_outdir}")
            kpfassemble_outdir = ktl.cache('kpfassemble', 'OUTDIR')
            try:
                kpfassemble_outdir.write(f"{L0_outdir}")
            except Exception as e:
                log.error(f"ERROR setting kpfasemble outdir")
                log.error(e)

    @classmethod
    def post_condition(cls, args):
        utnow = datetime.utcnow()
        date = utnow-timedelta(days=1)
        date_str = date.strftime('%Y%b%d').lower()
        outdir = Path(f"/s/sdata1701/{os.getlogin()}/{date_str}")
        tests = []
        if args.get('CRED2', True) is True:
            expr = f"$kpfguide.OUTDIR == '/s/sdata1701/kpfguide'"
            success = ktl.waitFor(expr, timeout=5)
            tests.append(success)
        if args.get('CRED2', True) is True:
            expr = f"$kpfguide.TRIGOUTDIR == '{outdir}/CRED2'"
            success = ktl.waitFor(expr, timeout=5)
            tests.append(success)
        if args.get('FVC1', False) is True:
            expr = f"$kpffvc.SCIOUTDIR == '{outdir}/FVC1'"
            success = ktl.waitFor(expr, timeout=5)
            tests.append(success)
        if args.get('FVC2', False) is True:
            expr = f"$kpffvc.CAHKOUTDIR == '{outdir}/FVC2'"
            success = ktl.waitFor(expr, timeout=5)
            tests.append(success)
        if args.get('FVC3', False) is True:
            expr = f"$kpffvc.CALOUTDIR == '{outdir}/FVC3'"
            success = ktl.waitFor(expr, timeout=5)
            tests.append(success)
        if args.get('FVC4', False) is True:
            expr = f"$kpffvc.EXTOUTDIR == '{outdir}/FVC4'"
            success = ktl.waitFor(expr, timeout=5)
            tests.append(success)
        if args.get('ExpMeter', True) is True:
            expr = f"$kpf_expmeter.DATADIR == '{outdir}/ExpMeter'"
            success = ktl.waitFor(expr, timeout=5)
            tests.append(success)
        if args.get('CaHK', True) is True:
            expr = f"$kpf_hk.RECORDDIR == '{outdir}/CaHK'"
            success = ktl.waitFor(expr, timeout=5)
            tests.append(success)
        if args.get('Green', True) is True:
            expr = f"$kpfgreen.FITSDIR == '{outdir}/Green'"
            success = ktl.waitFor(expr, timeout=5)
            tests.append(success)
        if args.get('Red', True) is True:
            expr = f"$kpfred.FITSDIR == '{outdir}/Red'"
            success = ktl.waitFor(expr, timeout=5)
            tests.append(success)
        if args.get('L0', True) is True:
            expr = f"$kpfassemble.OUTDIR == '{outdir}/L0'"
            success = ktl.waitFor(expr, timeout=5)
            tests.append(success)

        return np.all(np.array(tests))