DEIMOS
fcs_tint script

Name

fcs_tint -- set or show the FCS integration time

Purpose

Change the FCS integration time to the specified value by
stopping FCSTRACK, changing the value of the integration time
parameter in the FCS reference file, and restarting FCSTRACK

Usage

fcs_tint [tint]

Arguments

tint = number of seconds to exposure per RFCS integration

Output

If FCSTRACK is restarted, this window will receive copious
amounts of text from the script.

Side effects

If FCSTRACK is running, it is stopped and restarted.

Restrictions

User must have permission to modify the current FCS reference file.

Exit values

0 = normal completion
1 = wrong number of arguments

Example

1) show the current FCS integration time:
fcs_tint

1) set the current FCS integration time to 10 seconds:
fcs_tint 10

See Also

The shell script fcs_tint
DEIMOS script index


Go to: DEIMOS Home Page - Instruments Home Page - Keck Home Page

DEIMOS Master
Last modified: Wed Jun 9 16:30:34 2004