Project: UT Date: 2002-12-30 Observers: Faber, Wirth Weather: Data directory: /sdata1002/dmoseng/2002dec30 Seeing: Filename Obs Name PA Lamps Slitmsk Grating Waveln Filter Focus Exp Airmass Comments __________________________________________________________________________________________________________________________________ d1230_0001 0.00 GOSpH3 1200G 7800 OG550 -5003 50 1.41 Focus loop 1200/OG550 d1230_0002 0.00 GOSpH3 1200G 7800 OG550 -6001 50 1.41 Focus loop 1200/OG550 d1230_0003 0.00 GOSpH3 1200G 7800 OG550 -7001 50 1.41 Focus loop 1200/OG550 d1230_0004 0.00 GOSpH3 1200G 7800 OG550 -8001 50 1.41 Focus loop 1200/OG550 d1230_0005 0.00 GOSpH3 1200G 7800 OG550 -9002 50 1.41 Focus loop 1200/OG550 d1230_0006 0.00 GOSpH3 600ZD 7000 GG455 -5002 5 1.41 Focus loop 600/GG455 d1230_0007 0.00 GOSpH3 600ZD 7000 GG455 -6002 5 1.41 Focus loop 600/GG455 d1230_0008 0.00 GOSpH3 600ZD 7000 GG455 -7000 5 1.41 Focus loop 600/GG455 d1230_0009 0.00 GOSpH3 600ZD 7000 GG455 -8001 5 1.41 Focus loop 600/GG455 d1230_0010 0.00 GOSpH3 600ZD 7000 GG455 -9001 5 1.41 Focus loop 600/GG455 d1230_0011 0.00 GOSpH3 600ZD 7000 GG455 -10003 5 1.41 Focus loop 600/GG455 d1230_0012 0.00 GOSpH3 600ZD 7000 GG455 -11001 5 1.41 Focus loop 600/GG455 d1230_0013 0.00 Dome/Im GOH_X Mirror R -6002 30 1.41 focusloop/ R-band d1230_0014 0.00 Dome/Im GOH_X Mirror R -7002 30 1.41 focusloop/ R-band d1230_0015 0.00 Dome/Im GOH_X Mirror R -8001 30 1.41 focusloop/ R-band d1230_0016 0.00 Dome/Im GOH_X Mirror R -9002 30 1.41 focusloop/ R-band d1230_0017 0.00 Dome/Im GOH_X Mirror R -10002 30 1.41 focusloop/ R-band d1230_0018 G191B2B 180.00 None 1200G 6999 GG455 -8001 50 1.61 G191B2B standard star; 1200-line d1230_0019 G191B2B 180.00 None 1200G 7999 OG550 -7752 50 1.60 G191B2B standard star; 1200-line d1230_0020 G191B2B 180.00 None 600ZD 6500 GG455 -8251 30 1.58 G191B2B standard star; 600-line d1230_0021 G191B2B 180.00 None 600ZD 7500 OG550 -7751 30 1.57 G191B2B standard star; 600-line d1230_0022 4207.W 297.50 4207.W 1200G 521 R -7803 20 1.06 4207.W align d1230_0023 4207.W 297.47 4207.W 1200G 521 R -7803 20 1.06 4207.W align d1230_0024 4207.W 297.48 4207.W 600ZD 7000 GG455 -8001 1200 1.06 4207.W; spectral; 600-line d1230_0025 4207.W 297.47 4207.W 1200G 521 GG455 -8001 20 1.07 Alignment check d1230_0026 4207.W 297.47 4207.W 600ZD 7000 GG455 -8001 1200 1.07 4207.W; spectral; 600-line d1230_0027 4207.W 297.48 4207.W 600ZD 7000 GG455 -8001 1200 1.09 4207.W; spectral; 600-line d1230_0028 4207.W 297.48 4207.W 1200G 7800 OG550 -7752 1200 1.13 4207.W; spectral; 1200-line d1230_0029 4207.W 297.47 4207.W 1200G 521 OG550 -7752 20 1.17 Alignment check d1230_0030 4207.W 297.50 4207.W 1200G 521 OG550 -7752 20 1.19 Alignment check d1230_0031 4207.W 297.50 4207.W 1200G 7800 OG550 -7752 1200 1.19 4207.W; spectral; 1200-line d1230_0032 4207.W 297.50 4207.W 1200G 7800 OG550 -7752 1200 1.26 4207.W; spectral; 1200-line d1230_0033 G191B2B -90.00 None 1200G 6999 GG455 -8001 50 1.19 G191B2B standard; 1200-line d1230_0034 G191B2B -90.00 None 1200G 7999 OG550 -8001 50 1.19 G191B2B standard; 1200-line d1230_0035 G191B2B -90.00 None 600ZD 6500 GG455 -8000 50 1.19 G191B2B standard; 600-line d1230_0036 G191B2B -90.00 None 600ZD 7500 OG550 -8002 50 1.19 G191B2B standard; 600-line d1230_0037 n2437a 146.00 n2437a 1200G 521 R -8200 5 1.38 n2437a; align d1230_0038 n2437a 145.98 n2437a 1200G 521 R -8200 5 1.36 n2437a; align d1230_0039 n2437a 145.98 n2437a 1200G 521 R -8200 20 1.35 n2437a; align d1230_0040 n2437a 145.98 n2437a 1200G 521 V -8400 20 1.33 n2437a; align d1230_0041 n2437a 145.98 n2437a 1200G 521 V -8901 20 1.32 n2437a; align d1230_0042 n2437a 145.99 n2437a 1200G 521 I -8002 20 1.32 n2437a d1230_0043 n2437a 145.98 n2437a 1200G 521 I -8501 20 1.30 n2437a d1230_0044 n2437a 145.98 n2437a 1200G 521 R -8201 20 1.30 n2437a d1230_0045 n2437a 145.98 None 1200G 521 R -8201 20 1.29 n2437a d1230_0046 n2437a 145.99 None 1200G 521 V -8401 20 1.29 n2437a d1230_0047 n2437a 145.98 None 1200G 521 V -8901 20 1.28 n2437a d1230_0048 n2437a 145.98 None 1200G 521 I -8001 20 1.27 n2437a d1230_0049 n2437a 145.98 None 1200G 521 I -8501 20 1.27 n2437a d1230_0050 n2437a 145.98 GOH_X 1200G 521 R -8201 60 1.26 Sky through GOH_X d1230_0051 n2437a 145.98 GOH_X Mirror R -8200 60 1.25 Sky through GOH_X d1230_0052 n2437a 145.98 GOH_X Mirror V -8401 60 1.25 Sky through GOH_X d1230_0053 n2437a 145.98 GOH_X Mirror V -8901 60 1.25 Sky through GOH_X d1230_0054 n2437a 145.98 GOH_X Mirror I -8001 60 1.25 Sky through GOH_X d1230_0055 n2437a 145.98 GOH_X Mirror I -8501 60 1.24 Sky through GOH_X d1230_0056 n2437a 145.98 GOH_X Mirror R -7801 60 1.24 Sky through GOH_X d1230_0057 n2437a 145.99 GOH_X Mirror I -8900 60 1.24 Sky through GOH_X d1230_0058 n2437b -34.00 n2437b Mirror R -8200 5 1.23 n2347b align d1230_0059 n2437b -34.00 n2437b Mirror R -8200 5 1.23 n2347b align d1230_0060 n2437b 46.00 n2437b Mirror R -8200 5 1.22 n2347b align d1230_0061 n2437b -34.00 n2437b Mirror R -8200 5 1.22 n2347b align d1230_0062 n2437b -34.02 n2437b Mirror R -8200 5 1.22 n2347b align d1230_0063 n2437b -34.02 n2437b Mirror R -8200 5 1.22 n2347b align d1230_0064 n2437b -34.02 n2437b Mirror R -8200 20 1.22 n2347b d1230_0065 n2437b -34.02 n2437b Mirror V -8402 20 1.22 n2347b d1230_0066 n2437b -34.02 n2437b Mirror V -8901 20 1.22 n2347b d1230_0067 n2437b -34.02 n2437b Mirror I -8101 20 1.22 n2347b d1230_0068 n2437b -34.02 n2437b Mirror I -8501 20 1.22 n2347b d1230_0069 n2437b -34.02 None Mirror R -8202 20 1.22 n2347b; mask out d1230_0070 n2437b -34.02 None Mirror V -8401 20 1.22 n2347b; mask out d1230_0071 n2437b -34.02 None Mirror V -9285 20 1.22 n2347b; mask out d1230_0072 n2437b -34.02 None Mirror I -8001 20 1.22 n2347b; mask out d1230_0073 n2437b -34.02 None Mirror I -8500 20 1.22 n2347b; mask out d1230_0074 n2437b -34.02 GOH_X Mirror R -8202 60 1.22 Sky through GOH_X d1230_0075 n2437b -34.02 GOH_X Mirror V -8401 60 1.22 Sky through GOH_X d1230_0076 n2437b -34.02 GOH_X Mirror V -8901 60 1.22 Sky through GOH_X d1230_0077 n2437b -34.02 GOH_X Mirror I -8102 60 1.22 Sky through GOH_X d1230_0078 n2437b -34.02 GOH_X Mirror I -8502 60 1.22 Sky through GOH_X d1230_0079 n2437b -34.02 None Mirror OG550 -7752 60 1.22 Test exposure with OG550 d1230_0080 n2437b -34.02 None Mirror R -8200 60 1.23 Test exposure with R d1230_0081 Feige 34 180.00 None 1200G 6999 GG455 -8002 50 1.23 Feige 34 = Standard; 1200 l/mm + GG455 d1230_0082 Feige 34 180.00 None 1200G 7999 OG550 -7752 50 1.23 Feige 34 = Standard; 1200 l/mm + OG 550 d1230_0083 Feige 34 180.00 None 600ZD 6500 GG455 -8251 50 1.22 Feige 34 = Standard; 600 l/mm + GG 455 d1230_0084 Feige 34 180.00 None 600ZD 7500 OG550 -7752 50 1.21 Feige 34 = Standard; 600 l/mm +OG550 d1230_0085 GOODS-NORTH 315.00 None Mirror R -8200 300 1.74 GOODS-N : direct : R-band d1230_0086 GOODS-NORTH 315.00 None Mirror R -8200 300 1.69 Mosaic position (1,1) filter R d1230_0087 GOODS-NORTH 315.00 None Mirror R -8201 300 1.66 Mosaic position (1,2) filter R d1230_0088 GOODS-NORTH 315.00 None Mirror R -8201 300 1.63 Mosaic position (1,3) filter R d1230_0089 GOODS-NORTH 315.00 None Mirror R -8201 300 1.60 Mosaic position (1,4) filter R d1230_0090 GOODS-NORTH 315.00 None Mirror R -8201 300 1.58 Mosaic position (1,5) filter R d1230_0091 GOODS-NORTH 315.00 None Mirror R -8201 300 1.56 Mosaic position (1,6) filter R d1230_0092 GOODS-NORTH 315.00 None Mirror R -8201 300 1.54 Mosaic position (1,7) filter R d1230_0093 GOODS-NORTH 315.00 None Mirror R -8202 300 1.52 Mosaic position (1,8) filter R d1230_0094 GOODS-NORTH 315.00 GOH_X Mirror R -8202 60 1.50 GOODS-N : GOH_X calibration d1230_0095 GOODS-NORTH 405.00 None Mirror R -8203 300 1.48 Mosaic position (1,1) filter R d1230_0096 GOODS-NORTH 405.00 None Mirror R -8203 300 1.46 Mosaic position (1,2) filter R d1230_0097 GOODS-NORTH 405.00 None Mirror R -8204 300 1.45 Mosaic position (1,3) filter R d1230_0098 GOODS-NORTH 405.00 None Mirror R -8203 300 1.43 Mosaic position (1,4) filter R d1230_0099 GOODS-NORTH 405.00 None Mirror R -8204 300 1.42 Mosaic position (1,5) filter R d1230_0100 GOODS-NORTH 405.00 GOH_X Mirror R -8204 60 1.41 GOODS-N : GOH_X calibration d1230_0101 HORIZON STOW 405.00 Dome/Sp 4207.W 600ZD 7000 GG455 -8002 90 1.41 Dome flat field; 4207.W; 600-line d1230_0102 HORIZON STOW 405.00 Dome/Sp 4207.W 600ZD 7000 GG455 -8002 90 1.41 Dome flat field; 4207.W; 600-line d1230_0103 HORIZON STOW 405.00 Dome/Sp 4207.W 600ZD 7000 GG455 -8002 90 1.41 Dome flat field; 4207.W; 600-line d1230_0104 HORIZON STOW 405.00 Dome/Sp 4207.W 1200G 7800 OG550 -7754 150 1.41 Dome flat field; 4207.W; 1200-line d1230_0105 HORIZON STOW 405.00 Dome/Sp 4207.W 1200G 7800 OG550 -7754 150 1.41 Dome flat field; 4207.W; 1200-line d1230_0106 HORIZON STOW 405.00 Dome/Sp 4207.W 1200G 7800 OG550 -7754 150 1.41 Dome flat field; 4207.W; 1200-line d1230_0107 HORIZON STOW 405.00 Dome/Sp 4207.W 1200G 7800 OG550 -7754 20 1.41 Dome flat field; 4207.W; 1200-line d1230_0108 HORIZON STOW 405.00 Dome/Im None 1200G 7749 OG550 -7754 20 1.41 Archival slitless dome flat field; 1200-line d1230_0109 HORIZON STOW 405.00 Dome/Im None 1200G 7749 OG550 -7754 20 1.41 Archival slitless dome flat field; 1200-line d1230_0110 HORIZON STOW 405.00 Dome/Im None 1200G 7749 OG550 -7754 20 1.41 Archival slitless dome flat field; 1200-line d1230_0111 HORIZON STOW 405.00 Dome/Im None 1200G 6599 BAL12 -7751 20 1.41 Archival slitless dome flat field; 1200-line d1230_0112 HORIZON STOW 405.00 Dome/Im None 1200G 6599 BAL12 -7751 20 1.41 Archival slitless dome flat field; 1200-line d1230_0113 HORIZON STOW 405.00 Dome/Im None 1200G 6599 BAL12 -7751 20 1.41 Archival slitless dome flat field; 1200-line d1230_0114 HORIZON STOW 405.00 Dome/Sp 4207.W 600ZD 7000 GG455 -8000 15 1.41 Dome flat; 4207.W; 600-line d1230_0115 HORIZON STOW 405.00 Dome/Im GOH_X Mirror I -5002 10 1.41 Dome through focus; I band d1230_0116 HORIZON STOW 405.00 Dome/Im GOH_X Mirror I -6001 10 1.41 Dome through focus; I band d1230_0117 HORIZON STOW 405.00 Dome/Im GOH_X Mirror I -7002 10 1.41 Dome through focus; I band d1230_0118 HORIZON STOW 405.00 Dome/Im GOH_X Mirror I -8001 10 1.41 Dome through focus; I band d1230_0119 HORIZON STOW 405.00 Dome/Im GOH_X Mirror I -9002 10 1.41 Dome through focus; I band d1230_0120 HORIZON STOW 405.00 Dome/Im GOH_X Mirror I -10002 10 1.41 Dome through focus; I band d1230_0121 HORIZON STOW 405.00 Dome/Im GOH_X Mirror I -11002 10 1.41 Dome through focus; I band d1230_0122 HORIZON STOW 405.00 Dome/Sp GOH_X Mirror V -5004 2 1.41 Dome through focus; V band d1230_0123 HORIZON STOW 405.00 Dome/Sp GOH_X Mirror V -6002 2 1.41 Dome through focus; V band d1230_0124 HORIZON STOW 405.00 Dome/Sp GOH_X Mirror V -7002 2 1.41 Dome through focus; V band d1230_0125 HORIZON STOW 405.00 Dome/Sp GOH_X Mirror V -8002 2 1.41 Dome through focus; V band d1230_0126 HORIZON STOW 405.00 Dome/Sp GOH_X Mirror V -9001 2 1.41 Dome through focus; V band d1230_0127 HORIZON STOW 405.00 Dome/Sp GOH_X Mirror V -10001 2 1.41 Dome through focus; V band d1230_0128 HORIZON STOW 405.00 Dome/Sp GOH_X Mirror V -11001 2 1.41 Dome through focus; V band d1230_0129 HORIZON STOW 405.00 KrXeArNeDome/Sp 4207.W 1200G 7800 OG550 -7751 1 1.41 Internal arc; NAKX; 4207.W; 1200-line d1230_0130 HORIZON STOW 405.00 XeHgNeCd 4207.W 600ZD 7000 GG455 -8001 2 1.41 Internal arc; NHCX; 4207.W; 600-line d1230_0131 HORIZON STOW 405.00 Xe 4207.W 600ZD 7000 GG455 -8001 100 1.41 Internal arc; Xe; 4207.W; 600-line d1230_0132 HORIZON STOW 405.00 Qz 4207.W 600ZD 7000 GG455 -8001 6 1.41 Internal flat; Qz; 4207.W; 600-line d1230_0133 HORIZON STOW 405.00 Qz 4207.W 600ZD 7000 GG455 -8001 6 1.41 Internal flat; Qz; 4207.W; 600-line d1230_0134 HORIZON STOW 405.00 Qz 4207.W 600ZD 7000 GG455 -8001 6 1.41 Internal flat; Qz; 4207.W; 600-line d1230_0135 HORIZON STOW 405.00 Qz 4207.W 1200G 7800 OG550 -7752 12 1.41 Internal flat; Qz; 4207.W; 1200-line d1230_0136 HORIZON STOW 405.00 Qz 4207.W 1200G 7800 OG550 -7752 12 1.41 Internal flat; Qz; 4207.W; 1200-line d1230_0137 HORIZON STOW 405.00 Qz 4207.W 1200G 7800 OG550 -7752 12 1.41 Internal flat; Qz; 4207.W; 1200-line d1230_0138 HORIZON STOW 405.00 GOSpH3 1200G 7800 BAL12 -5002 50 1.41 Dome; through focus; 1200-line + BAL12 d1230_0139 HORIZON STOW 405.00 GOSpH3 1200G 7800 BAL12 -6002 50 1.41 Dome; through focus; 1200-line + BAL12 d1230_0140 HORIZON STOW 405.00 GOSpH3 1200G 7800 BAL12 -7002 50 1.41 Dome; through focus; 1200-line + BAL12 d1230_0141 HORIZON STOW 405.00 GOSpH3 1200G 7800 BAL12 -8001 50 1.41 Dome; through focus; 1200-line + BAL12 d1230_0142 HORIZON STOW 405.00 GOSpH3 1200G 7800 BAL12 -9002 50 1.41 Dome; through focus; 1200-line + BAL12 d1230_0143 HORIZON STOW 405.00 GOSpH3 1200G 7800 BAL12 -10001 50 1.41 Dome; through focus; 1200-line + BAL12 d1230_0144 HORIZON STOW 405.00 GOSpH3 1200G 7800 BAL12 -11002 50 1.41 Dome; through focus; 1200-line + BAL12 d1230_0145 HORIZON STOW 405.00 GOSpH3 1200G 7800 GG400 -5002 50 1.41 Dome; through focus; 1200-line + GG400 d1230_0146 HORIZON STOW 405.00 GOSpH3 1200G 7800 GG400 -6000 50 1.41 Dome; through focus; 1200-line + GG400 d1230_0147 HORIZON STOW 405.00 GOSpH3 1200G 7800 GG400 -7001 50 1.41 Dome; through focus; 1200-line + GG400 d1230_0148 HORIZON STOW 405.00 GOSpH3 1200G 7800 GG400 -8001 50 1.41 Dome; through focus; 1200-line + GG400 d1230_0149 HORIZON STOW 405.00 GOSpH3 1200G 7800 GG400 -9004 50 1.41 Dome; through focus; 1200-line + GG400 d1230_0150 HORIZON STOW 405.00 GOSpH3 1200G 7800 GG400 -10002 50 1.41 Dome; through focus; 1200-line + GG400 d1230_0151 HORIZON STOW 405.00 GOSpH3 1200G 7800 GG400 -11002 50 1.41 Dome; through focus; 1200-line + GG400 d1230_0152 HORIZON STOW 405.00 GOSpH3 600ZD 7000 GG400 -6002 7 1.41 Dome; through focus; 600-line + GG400 d1230_0153 HORIZON STOW 405.00 GOSpH3 600ZD 7000 GG400 -7002 7 1.41 Dome; through focus; 600-line + GG400 d1230_0154 HORIZON STOW 405.00 GOSpH3 600ZD 7000 GG400 -8002 7 1.41 Dome; through focus; 600-line + GG400 d1230_0155 HORIZON STOW 405.00 GOSpH3 600ZD 7000 GG400 -9002 7 1.41 Dome; through focus; 600-line + GG400 d1230_0156 HORIZON STOW 405.00 GOSpH3 600ZD 7000 GG400 -10002 7 1.41 Dome; through focus; 600-line + GG400 d1230_0157 HORIZON STOW 405.00 GOSpH3 600ZD 7000 BAL12 -6003 7 1.41 Dome; through focus; 600-line + BAL12 d1230_0158 HORIZON STOW 405.00 GOSpH3 600ZD 7000 BAL12 -7002 7 1.41 Dome; through focus; 600-line + BAL12 d1230_0159 HORIZON STOW 405.00 GOSpH3 600ZD 7000 BAL12 -8002 7 1.41 Dome; through focus; 600-line + BAL12 d1230_0160 HORIZON STOW 405.00 GOSpH3 600ZD 7000 BAL12 -9003 7 1.41 Dome; through focus; 600-line + BAL12 d1230_0161 HORIZON STOW 405.00 GOSpH3 600ZD 7000 BAL12 -10000 7 1.41 Dome; through focus; 600-line + BAL12 d1230_0162 HORIZON STOW 405.00 XeHgNeCd GOSpH3 600ZD 7000 GG455 -6002 2 1.41 Internal through focus; NHCX; 600-line + GG455 d1230_0163 HORIZON STOW 405.00 XeHgNeCd GOSpH3 600ZD 7000 GG455 -7001 2 1.41 Internal through focus; NHCX; 600-line + GG455 d1230_0164 HORIZON STOW 405.00 XeHgNeCd GOSpH3 600ZD 7000 GG455 -8003 2 1.41 Internal through focus; NHCX; 600-line + GG455 d1230_0165 HORIZON STOW 405.00 XeHgNeCd GOSpH3 600ZD 7000 GG455 -9002 2 1.41 Internal through focus; NHCX; 600-line + GG455 d1230_0166 HORIZON STOW 405.00 XeHgNeCd GOSpH3 600ZD 7000 GG455 -10001 2 1.41 Internal through focus; NHCX; 600-line + GG455 d1230_0167 HORIZON STOW 405.00 KrXeArNe GOSpH3 1200G 7800 OG550 -6002 1 1.41 Internal through focus; NHCX; 600-line + OG550 d1230_0168 HORIZON STOW 405.00 KrXeArNe GOSpH3 1200G 7800 OG550 -7001 1 1.41 Internal through focus; NHCX; 600-line + OG550 d1230_0169 HORIZON STOW 405.00 KrXeArNe GOSpH3 1200G 7800 OG550 -8001 1 1.41 Internal through focus; NHCX; 600-line + OG550 d1230_0170 HORIZON STOW 405.00 KrXeArNe GOSpH3 1200G 7800 OG550 -9001 1 1.41 Internal through focus; NHCX; 600-line + OG550 d1230_0171 HORIZON STOW 405.00 KrXeArNe GOSpH3 1200G 7800 OG550 -10002 1 1.41 Internal through focus; NHCX; 600-line + OG550 d1230_0172 HORIZON STOW 405.00 Hg GOH_X Mirror R -6003 1 1.41 Internal through focus; R-band d1230_0173 HORIZON STOW 405.00 Hg GOH_X Mirror R -7001 1 1.41 Internal through focus; R-band d1230_0174 HORIZON STOW 405.00 Hg GOH_X Mirror R -8001 1 1.41 Internal through focus; R-band d1230_0175 HORIZON STOW 405.00 Hg GOH_X Mirror R -9003 1 1.41 Internal through focus; R-band d1230_0176 HORIZON STOW 405.00 Hg GOH_X Mirror R -10002 1 1.41 Internal through focus; R-band d1230_0177 HORIZON STOW 405.00 Ne GOH_X Mirror V -6003 5 1.41 Internal through focus; V-band d1230_0178 HORIZON STOW 405.00 Ne GOH_X Mirror V -7000 5 1.41 Internal through focus; V-band d1230_0179 HORIZON STOW 405.00 Ne GOH_X Mirror V -8001 5 1.41 Internal through focus; V-band d1230_0180 HORIZON STOW 405.00 Ne GOH_X Mirror V -9003 5 1.41 Internal through focus; V-band d1230_0181 HORIZON STOW 405.00 Ne GOH_X Mirror V -10002 5 1.41 Internal through focus; V-band d1230_0182 HORIZON STOW 405.00 Ne GOH_X Mirror I -6006 2 1.41 Internal through focus; I-band d1230_0183 HORIZON STOW 405.00 Ne GOH_X Mirror I -7003 2 1.41 Internal through focus; I-band d1230_0184 HORIZON STOW 405.00 Ne GOH_X Mirror I -8001 2 1.41 Internal through focus; I-band d1230_0185 HORIZON STOW 405.00 Ne GOH_X Mirror I -9002 2 1.41 Internal through focus; I-band d1230_0186 HORIZON STOW 405.00 Ne GOH_X Mirror I -10001 2 1.41 Internal through focus; I-band d1230_0187 HORIZON STOW 405.00 GOH_X 1200G 7800 BAL12 -8000 10 1.41 Archival gratefop exposure d1230_0188 HORIZON STOW 405.00 GOH_X 1200G 7800 BAL12 -8000 10 1.41 Archival gratefop exposure d1230_0189 HORIZON STOW 405.00 GOH_X 1200G 7800 BAL12 -8000 10 1.41 Archival gratefop exposure foo -0.00 Hg 4207.W 1200G 521 R -7800 1 1.41 xbox alignment check