| Keywords from the DEICCD library |
| DEICCD.ABFREQ | antiblooming-frequency | integer |
| DEICCD.ABORTEX | abort-exposure | logical |
| DEICCD.ADDFRAME | add-frame-numbers | logical |
| DEICCD.AMPLIST | DEPRECATED-readout-amplifiers | array of integers[4] |
| DEICCD.AMPMODE | amplifier-readout-mode | enumerated integer |
| DEICCD.ANNOUNCE | announce | ascii string |
| DEICCD.ANTIBLM | antiblooming | logical |
| DEICCD.AUTOERAS | automatic-erase | logical |
| DEICCD.AUTOPANE | use-panes-to-set-window | enumerated integer |
| DEICCD.AUTOREAD | automatic-readout | logical |
| DEICCD.AUTOSHUT | automatic-shutter | logical |
| DEICCD.BINNING | binning | array of integers[2] |
| DEICCD.CCDBCAST | ccd-music-broadcasts | array of integers[12] |
| DEICCD.CCDGAIN | ccd-gain | logical |
| DEICCD.CCDPSIZE | CCD-physical-size | array of integers[4] |
| DEICCD.CCDSPEED | ccd-readout-speed | enumerated integer |
| DEICCD.CSHUTTER | camera-shutter | logical |
| DEICCD.DARKTIME | dark-time | real number |
| DEICCD.DATE | exposure-begin | integer |
| DEICCD.DATE | exposure-end | integer |
| DEICCD.DETECTOR | detector | ascii string |
| DEICCD.DETLSIZE | detector-logical-size | array of integers[4] |
| DEICCD.DEWARID | dewar-id | integer |
| DEICCD.DFORM | disk-file-format | ascii string |
| DEICCD.DISKFREE | readout-directory-free-space | real number |
| DEICCD.DISKFREP | readout-directory-free-percent | real number |
| DEICCD.DISKIMGS | readout-directory-disk-images | real number |
| DEICCD.DISKLIST | readout-directory-list | ascii string |
| DEICCD.DWRN2LV | ccd-dewar-nitrogen-level | real number |
| DEICCD.DWRN2LVM | ccd-dewar-nitrogen-level-map | array of real numbers[5] |
| DEICCD.DWRN2LVR | ccd-dewar-nitrogen-level-raw | integer |
| DEICCD.ELAPTIME | elapsed-time | integer |
| DEICCD.ERASECNT | erase-count | integer |
| DEICCD.ERASEIP | erase-in-progress | logical |
| DEICCD.ERASLINE | erase-line | logical |
| DEICCD.EXPOSE | start-exposure | logical |
| DEICCD.EXPOSIP | exposure-in-progress | logical |
| DEICCD.EXPTIME | exposure-time | real number |
| DEICCD.FCOMMENT | frame_comments | ascii string |
| DEICCD.FCSCORRX | FCS-X-correlation | real number |
| DEICCD.FCSCORRY | FCS-Y-correlation | real number |
| DEICCD.FCSERR | FCS-error-number | integer |
| DEICCD.FCSMODE | flexure-compensation-system-mode | enumerated integer |
| DEICCD.FCSMSG | flexure-compensation-system-message | ascii string |
| DEICCD.FCSRAD | FCS-accumulated-max-radius | real number |
| DEICCD.FCSSTA | flexure-compensation-system-status | enumerated integer |
| DEICCD.FLUSHMOD | flush-mode | enumerated integer |
| DEICCD.FRAMENO | frame-number | integer |
| DEICCD.ICOMMENT | instrument_comments | ascii string |
| DEICCD.IMSHMID | image-shared-mem-id | integer |
| DEICCD.IMSHMNI | image-shared-mem-num-ixhdu | integer |
| DEICCD.IMSHMSZ | image-shared-mem-size | integer |
| DEICCD.INFOMCFG | infoman_config_file_s | ascii string |
| DEICCD.INFOMCLK | infoman_clock | integer |
| DEICCD.INFOMDMP | infoman_dump_data | logical |
| DEICCD.INFOMDWM | infopatcher_do_what_i_mean | ascii string |
| DEICCD.INFOMHOM | infoman_host | ascii string |
| DEICCD.INFOMLOG | infoman_log | ascii string |
| DEICCD.INFOMMSG | infoman_message | ascii string |
| DEICCD.INFOMPID | infoman_pid | integer |
| DEICCD.INFOMSRV | infoman_server_s | ascii string |
| DEICCD.INFOMTRF | infoman_traffic_id | ascii string |
| DEICCD.INSTRUME | instrument | ascii string |
| DEICCD.KEEPPREP | keep-prescan-pixels | logical |
| DEICCD.LASTROWS | last-amp-rows-received | array of integers[2] |
| DEICCD.LFRAMENO | last-frame-number | integer |
| DEICCD.LTODISK | last-to-disk | logical |
| DEICCD.MOSMODE | mosiac-readout-mode | enumerated integer |
| DEICCD.MPPMODE | mpp-readout-mode | logical |
| DEICCD.NSUBINT | number-of-subintegrations | integer |
| DEICCD.NUMAMPS | DEPRECATED-number-of-amplifiers | integer |
| DEICCD.NVIDINP | number-of-video-inputs | integer |
| DEICCD.OBJECT | object | ascii string |
| DEICCD.OBSERVER | observer | ascii string |
| DEICCD.OBSTYPE | obstype | ascii string |
| DEICCD.OUTDIR | readout-directory | ascii string |
| DEICCD.OUTFILE | readout-filename | ascii string |
| DEICCD.OVRFLUSH | postscan-flush-lines | integer |
| DEICCD.PANE | pane | array of integers[4] |
| DEICCD.PANE1 | pane-1 | array of integers[4] |
| DEICCD.PANE10 | pane-10 | array of integers[4] |
| DEICCD.PANE11 | pane-11 | array of integers[4] |
| DEICCD.PANE12 | pane-12 | array of integers[4] |
| DEICCD.PANE13 | pane-13 | array of integers[4] |
| DEICCD.PANE14 | pane-14 | array of integers[4] |
| DEICCD.PANE15 | pane-15 | array of integers[4] |
| DEICCD.PANE16 | pane-16 | array of integers[4] |
| DEICCD.PANE2 | pane-2 | array of integers[4] |
| DEICCD.PANE3 | pane-3 | array of integers[4] |
| DEICCD.PANE4 | pane-4 | array of integers[4] |
| DEICCD.PANE5 | pane-5 | array of integers[4] |
| DEICCD.PANE6 | pane-6 | array of integers[4] |
| DEICCD.PANE7 | pane-7 | array of integers[4] |
| DEICCD.PANE8 | pane-8 | array of integers[4] |
| DEICCD.PANE9 | pane-9 | array of integers[4] |
| DEICCD.PANEFITS | pane-fits-hdu-format | enumerated integer |
| DEICCD.PANELIST | readout-pane-list | integer bit-mask |
| DEICCD.PANERROR | pane-error-list | integer bit-mask |
| DEICCD.PAUSE | pause-exposure | logical |
| DEICCD.PAUSEIP | pause-in-progress | logical |
| DEICCD.POSTLINE | postscan-lines | integer |
| DEICCD.POSTPIX | postscan-pixels | integer |
| DEICCD.PRECOL | prescan-columns | integer |
| DEICCD.PREFLUSH | prescan-flush-lines | integer |
| DEICCD.PRELINE | prescan-lines | integer |
| DEICCD.PREROW | prescan-rows | integer |
| DEICCD.PWRBLKR1 | ccd-dewar-heater-1-voltage-raw | integer |
| DEICCD.PWRBLKR2 | ccd-dewar-heater-2-voltage-raw | integer |
| DEICCD.PWRBLKR3 | ccd-dewar-heater-3-voltage-raw | integer |
| DEICCD.PWRBLKR4 | ccd-dewar-heater-4-voltage-raw | integer |
| DEICCD.PWRBLKR5 | ccd-dewar-heater-5-voltage-raw | integer |
| DEICCD.PWRBLKR6 | ccd-dewar-heater-6-voltage-raw | integer |
| DEICCD.PWRBLKR7 | ccd-dewar-heater-7-voltage-raw | integer |
| DEICCD.PWRBLKR8 | ccd-dewar-heater-8-voltage-raw | integer |
| DEICCD.PWRBLOK1 | ccd-dewar-heater-1-voltage | real number |
| DEICCD.PWRBLOK2 | ccd-dewar-heater-2-voltage | real number |
| DEICCD.PWRBLOK3 | ccd-dewar-heater-3-voltage | real number |
| DEICCD.PWRBLOK4 | ccd-dewar-heater-4-voltage | real number |
| DEICCD.PWRBLOK5 | ccd-dewar-heater-5-voltage | real number |
| DEICCD.PWRBLOK6 | ccd-dewar-heater-6-voltage | real number |
| DEICCD.PWRBLOK7 | ccd-dewar-heater-7-voltage | real number |
| DEICCD.PWRBLOK8 | ccd-dewar-heater-8-voltage | real number |
| DEICCD.PWRBLOKM | ccd-dewar-heater-voltage-map | array of real numbers[5] |
| DEICCD.RCOMMENT | run_comments | ascii string |
| DEICCD.RESN2LV | ccd-reservoir-nitrogen-level | real number |
| DEICCD.RESN2LVM | ccd-reservoir-nitrogen-level-map | array of real numbers[5] |
| DEICCD.RESN2LVR | ccd-reservoir-nitrogen-level-raw | integer |
| DEICCD.RESUME | resume-exposure | logical |
| DEICCD.ROWSHFT | row-shift-per-subintegrations | integer |
| DEICCD.RSERV | writing-server-memory | logical |
| DEICCD.SHBLCLTM | shutter-blade-closing-time | real number |
| DEICCD.SHBLOPTM | shutter-blade-opening-time | real number |
| DEICCD.SHCLOCNT | shutter-closing-count | integer |
| DEICCD.SHLATCLO | shutter-latency-on-closing | real number |
| DEICCD.SHLATOPN | shutter-latency-on-opening | real number |
| DEICCD.SHOPNCNT | shutter-opening-count | integer |
| DEICCD.SHUTSTAT | shutter-status | enumerated integer |
| DEICCD.SHUTTER | shutter | logical |
| DEICCD.STOPEX | stop-exposure | logical |
| DEICCD.SYNOPFMT | format_for_SYNOPSIS | ascii string |
| DEICCD.SYNOPSIS | synopsis_of_FITS_keywords | ascii string |
| DEICCD.TEMPDET | detector-avg-temperature | real number |
| DEICCD.TEMPDET1 | detector-1-temperature | real number |
| DEICCD.TEMPDET2 | detector-2-temperature | real number |
| DEICCD.TEMPDET3 | detector-3-temperature | real number |
| DEICCD.TEMPDET4 | detector-4-temperature | real number |
| DEICCD.TEMPDET5 | detector-5-temperature | real number |
| DEICCD.TEMPDET6 | detector-6-temperature | real number |
| DEICCD.TEMPDET7 | detector-7-temperature | real number |
| DEICCD.TEMPDET8 | detector-8-temperature | real number |
| DEICCD.TEMPDETM | detector-temperature-map | array of real numbers[5] |
| DEICCD.TEMPDETR | detector-avg-temperature-raw | integer |
| DEICCD.TEMPSET | ccd-desired-dewar-temperature | real number |
| DEICCD.TEMPSETM | ccd-desired-dewar-temperature-map | array of real numbers[5] |
| DEICCD.TEMPSETR | ccd-desired-dewar-temperature-raw | integer |
| DEICCD.TMPDET1M | detector-1-temperature-map | array of real numbers[5] |
| DEICCD.TMPDET2M | detector-2-temperature-map | array of real numbers[5] |
| DEICCD.TMPDET3M | detector-3-temperature-map | array of real numbers[5] |
| DEICCD.TMPDET4M | detector-4-temperature-map | array of real numbers[5] |
| DEICCD.TMPDET5M | detector-5-temperature-map | array of real numbers[5] |
| DEICCD.TMPDET6M | detector-6-temperature-map | array of real numbers[5] |
| DEICCD.TMPDET7M | detector-7-temperature-map | array of real numbers[5] |
| DEICCD.TMPDET8M | detector-8-temperature-map | array of real numbers[5] |
| DEICCD.TMPDETR1 | detector-1-temperature-raw | integer |
| DEICCD.TMPDETR2 | detector-2-temperature-raw | integer |
| DEICCD.TMPDETR3 | detector-3-temperature-raw | integer |
| DEICCD.TMPDETR4 | detector-4-temperature-raw | integer |
| DEICCD.TMPDETR5 | detector-5-temperature-raw | integer |
| DEICCD.TMPDETR6 | detector-6-temperature-raw | integer |
| DEICCD.TMPDETR7 | detector-7-temperature-raw | integer |
| DEICCD.TMPDETR8 | detector-8-temperature-raw | integer |
| DEICCD.TODISK | to-disk | logical |
| DEICCD.TTIME | total-time | integer |
| DEICCD.UTB15VEN | ccd-15-volts-enable | logical |
| DEICCD.UTB30VEN | ccd-30-volts-enable | logical |
| DEICCD.UTBFANS | ccd-controller-fans | logical |
| DEICCD.UTBM15V | ccd-minus-15-volts | real number |
| DEICCD.UTBM15VM | ccd-minus-15-volts-map | array of real numbers[5] |
| DEICCD.UTBM15VR | ccd-minus-15-volts-raw | integer |
| DEICCD.UTBN2FIL | ccd-liquid-n2-pressure-valve | logical |
| DEICCD.UTBN2HTR | ccd-liquid-n2-reservoir-heater | logical |
| DEICCD.UTBP15V | ccd-plus-15-volts | real number |
| DEICCD.UTBP15VM | ccd-plus-15-volts-map | array of real numbers[5] |
| DEICCD.UTBP15VR | ccd-plus-15-volts-raw | integer |
| DEICCD.UTBP30V | ccd-plus-30-volts | real number |
| DEICCD.UTBP30VM | ccd-plus-30-volts-map | array of real numbers[5] |
| DEICCD.UTBP30VR | ccd-plus-30-volts-raw | integer |
| DEICCD.UTBP5V | ccd-plus-5-volts | real number |
| DEICCD.UTBP5VM | ccd-plus-5-volts-map | array of real numbers[5] |
| DEICCD.UTBP5VR | ccd-plus-5-volts-raw | integer |
| DEICCD.UTBTEMP | ccd-utility-board-temperature | real number |
| DEICCD.UTBTEMPM | ccd-utility-board-temperature-map | array of real numbers[5] |
| DEICCD.UTBTEMPR | ccd-utility-board-temperature-raw | integer |
| DEICCD.UTBTMPS | ccd-desired-utility-board-temperature | real number |
| DEICCD.UTBTMPSM | ccd-desired-utility-board-temperature-map | array of real numbers[5] |
| DEICCD.UTBTMPSR | ccd-desired-utility-board-temperature-raw | integer |
| DEICCD.VIDINP1 | video-input-1-id | integer |
| DEICCD.VIDINP10 | video-input-10-id | integer |
| DEICCD.VIDINP11 | video-input-11-id | integer |
| DEICCD.VIDINP12 | video-input-12-id | integer |
| DEICCD.VIDINP13 | video-input-13-id | integer |
| DEICCD.VIDINP14 | video-input-14-id | integer |
| DEICCD.VIDINP15 | video-input-15-id | integer |
| DEICCD.VIDINP16 | video-input-16-id | integer |
| DEICCD.VIDINP2 | video-input-2-id | integer |
| DEICCD.VIDINP3 | video-input-3-id | integer |
| DEICCD.VIDINP4 | video-input-4-id | integer |
| DEICCD.VIDINP5 | video-input-5-id | integer |
| DEICCD.VIDINP6 | video-input-6-id | integer |
| DEICCD.VIDINP7 | video-input-7-id | integer |
| DEICCD.VIDINP8 | video-input-8-id | integer |
| DEICCD.VIDINP9 | video-input-9-id | integer |
| DEICCD.VIDOFF1 | vidoff-1 | integer |
| DEICCD.VIDOFF10 | vidoff-10 | integer |
| DEICCD.VIDOFF11 | vidoff-11 | integer |
| DEICCD.VIDOFF12 | vidoff-12 | integer |
| DEICCD.VIDOFF13 | vidoff-13 | integer |
| DEICCD.VIDOFF14 | vidoff-14 | integer |
| DEICCD.VIDOFF15 | vidoff-15 | integer |
| DEICCD.VIDOFF16 | vidoff-16 | integer |
| DEICCD.VIDOFF2 | vidoff-2 | integer |
| DEICCD.VIDOFF3 | vidoff-3 | integer |
| DEICCD.VIDOFF4 | vidoff-4 | integer |
| DEICCD.VIDOFF5 | vidoff-5 | integer |
| DEICCD.VIDOFF6 | vidoff-6 | integer |
| DEICCD.VIDOFF7 | vidoff-7 | integer |
| DEICCD.VIDOFF8 | vidoff-8 | integer |
| DEICCD.VIDOFF9 | vidoff-9 | integer |
| DEICCD.WCRATE | writing-crate-memory | logical |
| DEICCD.WDISK | writing-disk | logical |
| DEICCD.WINDOW | window | array of integers[5] |
| DEICCD.WSERV | writing-lickserv2 | logical |
| Keywords from the DEIMOT library |
| DEIMOT.AIRPRESS | air-pressure-status | logical |
| DEIMOT.APPERROR | ancillary-script-error | ascii string |
| DEIMOT.BARGNCFG | slitmask-bar-code-reader-configuration | ascii string |
| DEIMOT.BARGNERR | ?? | integer
|
| DEIMOT.BARGNGET | slitmask-bar-code | ascii string |
| DEIMOT.C1AIN04 | controller-1-analog-input-4 | real number |
| DEIMOT.C1AIN05 | controller-1-analog-input-5 | real number |
| DEIMOT.C1AIN06 | controller-1-analog-input-6 | real number |
| DEIMOT.C1AIN07 | controller-1-analog-input-7 | real number |
| DEIMOT.C1AIN1B | controller-1-analog-mux-input-1b | real number |
| DEIMOT.C1AIN2A | controller-1-analog-mux-input-2a | real number |
| DEIMOT.C1AIN2B | controller-1-analog-mux-input-2b | real number |
| DEIMOT.C1AIN3A | controller-1-analog-mux-input-3a | real number |
| DEIMOT.C1AIN3B | controller-1-analog-mux-input-3b | real number |
| DEIMOT.C1AIN4A | controller-1-analog-mux-input-4a | real number |
| DEIMOT.C1AIN4B | controller-1-analog-mux-input-4b | real number |
| DEIMOT.C1AIN4C | controller-1-analog-mux-input-4c | real number |
| DEIMOT.C1AIN5A | controller-1-analog-mux-input-5a | real number |
| DEIMOT.C1AIN5B | controller-1-analog-mux-input-5b | real number |
| DEIMOT.C1AIN6A | controller-1-analog-mux-input-6a | real number |
| DEIMOT.C1AIN6B | controller-1-analog-mux-input-6b | real number |
| DEIMOT.C1AIN7A | controller-1-analog-mux-input-7a | real number |
| DEIMOT.C1AIN7B | controller-1-analog-mux-input-7b | real number |
| DEIMOT.C1AIN8A | controller-1-analog-mux-input-8a | real number |
| DEIMOT.C1AIN8B | controller-1-analog-mux-input-8b | real number |
| DEIMOT.C1AMUXL1 | controller-1-mux-line-1 | real number |
| DEIMOT.C1AMUXL2 | controller-1-mux-line-2 | real number |
| DEIMOT.C1AMUXL3 | controller-1-mux-line-3 | real number |
| DEIMOT.C1AMUXS0 | controller-1-mux-select-0 | logical |
| DEIMOT.C1AMUXS1 | controller-1-mux-select-1 | logical |
| DEIMOT.C1AMUXS2 | controller-1-mux-select-2 | logical |
| DEIMOT.C1DIN03 | controller-1-digital-input-3 | logical |
| DEIMOT.C1DIN04 | controller-1-digital-input-4 | logical |
| DEIMOT.C1DIN05 | controller-1-digital-input-5 | logical |
| DEIMOT.C1DIN06 | controller-1-digital-input-6 | logical |
| DEIMOT.C1DIN07 | controller-1-digital-input-7 | logical |
| DEIMOT.C1DIN08 | controller-1-digital-input-8 | logical |
| DEIMOT.C1DIN12 | controller-1-digital-input-12 | logical |
| DEIMOT.C1DIN13 | controller-1-digital-input-13 | logical |
| DEIMOT.C1DIN14 | controller-1-digital-input-14 | logical |
| DEIMOT.C1DIN15 | controller-1-digital-input-15 | logical |
| DEIMOT.C1DIN16 | controller-1-digital-input-16 | logical |
| DEIMOT.C1DIN17 | controller-1-digital-input-17 | logical |
| DEIMOT.C1DIN18 | controller-1-digital-input-18 | logical |
| DEIMOT.C1DIN19 | controller-1-digital-input-19 | logical |
| DEIMOT.C1DIN20 | controller-1-digital-input-20 | logical |
| DEIMOT.C1DIN21 | controller-1-digital-input-21 | logical |
| DEIMOT.C1DIN22 | controller-1-digital-input-22 | logical |
| DEIMOT.C1DIN23 | controller-1-digital-input-23 | logical |
| DEIMOT.C1DIN24 | controller-1-digital-input-24 | logical |
| DEIMOT.C1DIN52 | controller-1-digital-input-52 | logical |
| DEIMOT.C1DIN53 | controller-1-digital-input-53 | logical |
| DEIMOT.C1DIN54 | controller-1-digital-input-54 | logical |
| DEIMOT.C1DIN55 | controller-1-digital-input-55 | logical |
| DEIMOT.C1DIN56 | controller-1-digital-input-56 | logical |
| DEIMOT.C1DIN58 | controller-1-digital-input-58 | logical |
| DEIMOT.C1DIN59 | controller-1-digital-input-59 | logical |
| DEIMOT.C1DIN60 | controller-1-digital-input-60 | logical |
| DEIMOT.C1DIN61 | controller-1-digital-input-61 | logical |
| DEIMOT.C1DIN62 | controller-1-digital-input-62 | logical |
| DEIMOT.C1DIN63 | controller-1-digital-input-63 | logical |
| DEIMOT.C1DIN64 | controller-1-digital-input-64 | logical |
| DEIMOT.C1DIN65 | controller-1-digital-input-65 | logical |
| DEIMOT.C1DIN66 | controller-1-digital-input-66 | logical |
| DEIMOT.C1DIN67 | controller-1-digital-input-67 | logical |
| DEIMOT.C1DIN85 | controller-1-digital-input-85 | logical |
| DEIMOT.C1DIN86 | controller-1-digital-input-86 | logical |
| DEIMOT.C1DIN87 | controller-1-digital-input-87 | logical |
| DEIMOT.C1DIN90 | controller-1-digital-input-90 | logical |
| DEIMOT.C1DIN91 | controller-1-digital-input-91 | logical |
| DEIMOT.C1DIN92 | controller-1-digital-input-92 | logical |
| DEIMOT.C1DIN93 | controller-1-digital-input-93 | logical |
| DEIMOT.C1DIN94 | controller-1-digital-input-94 | logical |
| DEIMOT.C1DIN95 | controller-1-digital-input-95 | logical |
| DEIMOT.C1DIN96 | controller-1-digital-input-96 | logical |
| DEIMOT.C1DOUT03 | controller-1-digital-output-3 | logical |
| DEIMOT.C1DOUT04 | controller-1-digital-output-4 | logical |
| DEIMOT.C1DOUT08 | controller-1-digital-output-8 | logical |
| DEIMOT.C1DOUT12 | controller-1-digital-output-12 | logical |
| DEIMOT.C1DOUT13 | controller-1-digital-output-13 | logical |
| DEIMOT.C1DOUT14 | controller-1-digital-output-14 | logical |
| DEIMOT.C1DOUT15 | controller-1-digital-output-15 | logical |
| DEIMOT.C1DOUT16 | controller-1-digital-output-16 | logical |
| DEIMOT.C1DOUT26 | controller-1-digital-output-26 | logical |
| DEIMOT.C1DOUT42 | controller-1-digital-output-42 | logical |
| DEIMOT.C1DOUT43 | controller-1-digital-output-43 | logical |
| DEIMOT.C2AIN04 | controller-2-analog-input-4 | real number |
| DEIMOT.C2AIN05 | controller-2-analog-input-5 | real number |
| DEIMOT.C2AIN06 | controller-2-analog-input-6 | real number |
| DEIMOT.C2AIN07 | controller-2-analog-input-7 | real number |
| DEIMOT.C2AIN1B | controller-2-analog-mux-input-1b | real number |
| DEIMOT.C2AIN2B | controller-2-analog-mux-input-2b | real number |
| DEIMOT.C2AIN3A | controller-2-analog-mux-input-3a | real number |
| DEIMOT.C2AIN3B | controller-2-analog-mux-input-3b | real number |
| DEIMOT.C2AIN4A | controller-2-analog-mux-input-4a | real number |
| DEIMOT.C2AIN4B | controller-2-analog-mux-input-4b | real number |
| DEIMOT.C2AIN4C | controller-2-analog-mux-input-4c | real number |
| DEIMOT.C2AIN5A | controller-2-analog-mux-input-5a | real number |
| DEIMOT.C2AIN5B | controller-2-analog-mux-input-5b | real number |
| DEIMOT.C2AIN5C | controller-2-analog-mux-input-5c | real number |
| DEIMOT.C2AIN6A | controller-2-analog-mux-input-6a | real number |
| DEIMOT.C2AIN6B | controller-2-analog-mux-input-6b | real number |
| DEIMOT.C2AIN6C | controller-2-analog-mux-input-6c | real number |
| DEIMOT.C2AIN7A | controller-2-analog-mux-input-7a | real number |
| DEIMOT.C2AIN7B | controller-2-analog-mux-input-7b | real number |
| DEIMOT.C2AIN8A | controller-2-analog-mux-input-8a | real number |
| DEIMOT.C2AIN8B | controller-2-analog-mux-input-8b | real number |
| DEIMOT.C2AIN8C | controller-2-analog-mux-input-8c | real number |
| DEIMOT.C2AMUXL1 | controller-2-mux-line-1 | real number |
| DEIMOT.C2AMUXL2 | controller-2-mux-line-2 | real number |
| DEIMOT.C2AMUXL3 | controller-2-mux-line-3 | real number |
| DEIMOT.C2AMUXS0 | controller-2-mux-select-0 | logical |
| DEIMOT.C2AMUXS1 | controller-2-mux-select-1 | logical |
| DEIMOT.C2AMUXS2 | controller-2-mux-select-2 | logical |
| DEIMOT.C2DIN05 | controller-2-digital-input-5 | logical |
| DEIMOT.C2DIN06 | controller-2-digital-input-6 | logical |
| DEIMOT.C2DIN07 | controller-2-digital-input-7 | logical |
| DEIMOT.C2DIN08 | controller-2-digital-input-8 | logical |
| DEIMOT.C2DIN10 | controller-2-digital-input-10 | logical |
| DEIMOT.C2DIN11 | controller-2-digital-input-11 | logical |
| DEIMOT.C2DIN12 | controller-2-digital-input-12 | logical |
| DEIMOT.C2DIN13 | controller-2-digital-input-13 | logical |
| DEIMOT.C2DIN14 | controller-2-digital-input-14 | logical |
| DEIMOT.C2DIN15 | controller-2-digital-input-15 | logical |
| DEIMOT.C2DIN16 | controller-2-digital-input-16 | logical |
| DEIMOT.C2DIN17 | controller-2-digital-input-17 | logical |
| DEIMOT.C2DIN18 | controller-2-digital-input-18 | logical |
| DEIMOT.C2DIN19 | controller-2-digital-input-19 | logical |
| DEIMOT.C2DIN20 | controller-2-digital-input-20 | logical |
| DEIMOT.C2DIN21 | controller-2-digital-input-21 | logical |
| DEIMOT.C2DIN22 | controller-2-digital-input-22 | logical |
| DEIMOT.C2DIN23 | controller-2-digital-input-23 | logical |
| DEIMOT.C2DIN24 | controller-2-digital-input-24 | logical |
| DEIMOT.C2DIN68 | controller-2-digital-input-68 | logical |
| DEIMOT.C2DIN85 | controller-2-digital-input-85 | logical |
| DEIMOT.C2DIN86 | controller-2-digital-input-86 | logical |
| DEIMOT.C2DOUT08 | controller-2-digital-output-8 | logical |
| DEIMOT.C2DOUT10 | controller-2-digital-output-10 | logical |
| DEIMOT.C2DOUT11 | controller-2-digital-output-11 | logical |
| DEIMOT.C2DOUT12 | controller-2-digital-output-12 | logical |
| DEIMOT.C2DOUT13 | controller-2-digital-output-13 | logical |
| DEIMOT.C2DOUT14 | controller-2-digital-output-14 | logical |
| DEIMOT.C2DOUT15 | controller-2-digital-output-15 | logical |
| DEIMOT.C2DOUT16 | controller-2-digital-output-16 | logical |
| DEIMOT.COOLFAN | electronics-ring-coolant-fan-power | logical |
| DEIMOT.CTRL1BEK | controller-1-bekins | enumerated integer |
| DEIMOT.CTRL1CLK | controller-1-clock | integer |
| DEIMOT.CTRL1DMP | controller-1-dump | logical |
| DEIMOT.CTRL1MOD | controller-1-control-mode | enumerated integer |
| DEIMOT.CTRL1MON | controller-1-monitor | enumerated integer |
| DEIMOT.CTRL1UHL | controller-1-uhaul | enumerated integer |
| DEIMOT.CTRL1VER | controller-1-version | ascii string |
| DEIMOT.CTRL2BEK | controller-2-bekins | enumerated integer |
| DEIMOT.CTRL2CLK | controller-2-clock | integer |
| DEIMOT.CTRL2DMP | controller-2-dump | logical |
| DEIMOT.CTRL2MOD | controller-2-control-mode | enumerated integer |
| DEIMOT.CTRL2MON | controller-2-monitor | enumerated integer |
| DEIMOT.CTRL2UHL | controller-2-uhaul | enumerated integer |
| DEIMOT.CTRL2VER | controller-2-version | ascii string |
| DEIMOT.CTRL3CLK | controller-3-clock | integer |
| DEIMOT.CTRL3VER | controller-3-version | ascii string |
| DEIMOT.CTRL4CLK | controller-4-clock | integer |
| DEIMOT.CTRL4VER | controller-4-version | ascii string |
| DEIMOT.CTRL5CLK | controller-5-clock | integer |
| DEIMOT.CTRL5VER | controller-5-version | ascii string |
| DEIMOT.CTRL7CLK | controller-7-clock | integer |
| DEIMOT.CTRL7VER | controller-7-version | ascii string |
| DEIMOT.DISP1CFG | dispatcher-1-config-time-stamp | ascii string |
| DEIMOT.DISP1DMP | dispatcher-1-dump | logical |
| DEIMOT.DISP1DSK | dispatcher-1-disk-space | integer |
| DEIMOT.DISP1HOM | dispatcher-1-host-machine | ascii string |
| DEIMOT.DISP1LOG | dispatcher-1-log-filename | ascii string |
| DEIMOT.DISP1MOD | dispatcher-1-control-mode | enumerated integer |
| DEIMOT.DISP1MSG | dispatcher-1-message | ascii string |
| DEIMOT.DISP1PID | dispatcher-1-process-id | integer |
| DEIMOT.DISP2CFG | dispatcher-2-config-time-stamp | ascii string |
| DEIMOT.DISP2DMP | dispatcher-2-dump | logical |
| DEIMOT.DISP2DSK | dispatcher-2-disk-space | integer |
| DEIMOT.DISP2HOM | dispatcher-2-host-machine | ascii string |
| DEIMOT.DISP2LOG | dispatcher-2-log-filename | ascii string |
| DEIMOT.DISP2MOD | dispatcher-2-control-mode | enumerated integer |
| DEIMOT.DISP2MSG | dispatcher-2-message | ascii string |
| DEIMOT.DISP2PID | dispatcher-2-process-id | integer |
| DEIMOT.DISP3DMP | dispatcher-3-dump | logical |
| DEIMOT.DISP3DWM | dispatcher-3-DWIM | ascii string |
| DEIMOT.DISP3HOM | dispatcher-3-host-machine | ascii string |
| DEIMOT.DISP3LOG | dispatcher-3-log-file | ascii string |
| DEIMOT.DISP3MSG | dispatcher-3-message | ascii string |
| DEIMOT.DISP3PID | dispatcher-3-process-id | integer |
| DEIMOT.DISP4DMP | dispatcher-4-dump | logical |
| DEIMOT.DISP4DWM | dispatcher-4-DWIM | ascii string |
| DEIMOT.DISP4HOM | dispatcher-4-host-machine | ascii string |
| DEIMOT.DISP4LOG | dispatcher-4-log-file | ascii string |
| DEIMOT.DISP4MSG | dispatcher-4-message | ascii string |
| DEIMOT.DISP4PID | dispatcher-4-process-id | integer |
| DEIMOT.DISP5DMP | dispatcher-5-dump | logical |
| DEIMOT.DISP5DWM | dispatcher-5-DWIM | ascii string |
| DEIMOT.DISP5HOM | dispatcher-5-host-machine | ascii string |
| DEIMOT.DISP5LOG | dispatcher-5-log-file | ascii string |
| DEIMOT.DISP5MSG | dispatcher-5-message | ascii string |
| DEIMOT.DISP5PID | dispatcher-5-process-id | integer |
| DEIMOT.DISP7DMP | dispatcher-7-dump | logical |
| DEIMOT.DISP7DWM | dispatcher-7-DWIM | ascii string |
| DEIMOT.DISP7HOM | dispatcher-7-host-machine | ascii string |
| DEIMOT.DISP7LOG | dispatcher-7-log-file | ascii string |
| DEIMOT.DISP7MSG | dispatcher-7-message | ascii string |
| DEIMOT.DISP7PID | dispatcher-7-process-id | integer |
| DEIMOT.DREMBARS | dremel-barcode-list | ascii string |
| DEIMOT.DREMCMIT | dremel-commit-status | ascii string |
| DEIMOT.DREMELDO | dremel-command | ascii string |
| DEIMOT.DREMEROR | dremel-error-message | ascii string |
| DEIMOT.DREMESAG | dremel-message | ascii string |
| DEIMOT.DREMEVNT | dremel-last-event | ascii string |
| DEIMOT.DREMFITS | dremel-fits-status | ascii string |
| DEIMOT.DREMJAMS | dremel-jammed-slots | ascii string |
| DEIMOT.DREMPOPS | dremel-populated-slots | ascii string |
| DEIMOT.DREMPTYS | dremel-empty-slots | ascii string |
| DEIMOT.DREMSCAN | dremel-scan-status | ascii string |
| DEIMOT.DREMSTAT | dremel-status | ascii string |
| DEIMOT.DREMTICK | dremel-heartbeat | integer |
| DEIMOT.DREMUBAR | dremel-user-bar-list | ascii string |
| DEIMOT.DWFHATCH | dewar-filter-hatch | logical |
| DEIMOT.DWFILCAL | dewar-filter-calibration | logical |
| DEIMOT.DWFILDMP | dewar-filter-dump | logical |
| DEIMOT.DWFILERR | dewar-filter-error-number | integer |
| DEIMOT.DWFILFIP | dewar-filter-fiducial-light-sensor | logical |
| DEIMOT.DWFILFOP | dewar-filter-fiducial-light-source | logical |
| DEIMOT.DWFILLCK | dewar-filter-lock | ascii string |
| DEIMOT.DWFILMOD | dewar-filter-control-mode | enumerated integer |
| DEIMOT.DWFILMSG | dewar-filter-message | ascii string |
| DEIMOT.DWFILNAM | dewar-filter-named-position | ascii string |
| DEIMOT.DWFILORD | dewar-filter-ordinal-position | integer |
| DEIMOT.DWFILRAW | dewar-filter-raw-position | integer |
| DEIMOT.DWFILSPD | dewar-filter-speed | integer |
| DEIMOT.DWFILSTA | dewar-filter-status | enumerated integer |
| DEIMOT.DWFILTOR | dewar-filter-torque | real number |
| DEIMOT.DWFILTRG | dewar-filter-raw-position-target | integer |
| DEIMOT.DWFILTSP | dewar-filter-speed-target | integer |
| DEIMOT.DWFILVAL | dewar-filter-value | real number |
| DEIMOT.DWFILVEL | dewar-filter-velocity | real number |
| DEIMOT.DWFILVRB | dewar-filter-verbose-messages | logical |
| DEIMOT.DWFIPLED | dewar-filter-in-unload-position-led | logical |
| DEIMOT.DWFMVLED | dewar-filter-moving-led | logical |
| DEIMOT.DWFOCCAL | dewar-focus-calibration | logical |
| DEIMOT.DWFOCDMP | dewar-focus-dump | logical |
| DEIMOT.DWFOCERR | dewar-focus-error-number | integer |
| DEIMOT.DWFOCFIP | dewar-focus-fiducial-light-sensor | logical |
| DEIMOT.DWFOCFOP | dewar-focus-fiducial-light-source | logical |
| DEIMOT.DWFOCLCK | dewar-focus-lock | ascii string |
| DEIMOT.DWFOCLIM | dewar-focus-limits | enumerated integer |
| DEIMOT.DWFOCMOD | dewar-focus-control-mode | enumerated integer |
| DEIMOT.DWFOCMSG | dewar-focus-message | ascii string |
| DEIMOT.DWFOCNAM | dewar-focus-named-position | ascii string |
| DEIMOT.DWFOCORD | dewar-focus-ordinal-position | integer |
| DEIMOT.DWFOCRAW | dewar-focus-raw-position | integer |
| DEIMOT.DWFOCSPD | dewar-focus-speed | integer |
| DEIMOT.DWFOCSTA | dewar-focus-status | enumerated integer |
| DEIMOT.DWFOCTOR | dewar-focus-torque | real number |
| DEIMOT.DWFOCTRG | dewar-focus-raw-position-target | integer |
| DEIMOT.DWFOCTSP | dewar-focus-speed-target | integer |
| DEIMOT.DWFOCVAL | dewar-focus-value | real number |
| DEIMOT.DWFOCVEL | dewar-focus-velocity | real number |
| DEIMOT.DWFOCVRB | dewar-focus-verbose-messages | logical |
| DEIMOT.DWFREQ0 | dewar-filter-manual-control-request-button-bit-0 | logical |
| DEIMOT.DWFREQ1 | dewar-filter-manual-control-request-button-bit-1 | logical |
| DEIMOT.DWFREQ2 | dewar-filter-manual-control-request-button-bit-2 | logical |
| DEIMOT.DWFSBUT | dewar-filter-manual-control-stop-button | logical |
| DEIMOT.DWHATCH1 | dewar-hatch-1 | logical |
| DEIMOT.DWHATCH2 | dewar-hatch-2 | logical |
| DEIMOT.DWXL8CAL | dewar-translation-calibration | logical |
| DEIMOT.DWXL8DMP | dewar-translation-dump | logical |
| DEIMOT.DWXL8ERR | dewar-translation-error-number | integer |
| DEIMOT.DWXL8FIP | dewar-translation-fiducial-light-sensor | logical |
| DEIMOT.DWXL8FOP | dewar-translation-fiducial-light-source | logical |
| DEIMOT.DWXL8LCK | dewar-translation-lock | ascii string |
| DEIMOT.DWXL8LIM | dewar-translation-limits | enumerated integer |
| DEIMOT.DWXL8MOD | dewar-translation-control-mode | enumerated integer |
| DEIMOT.DWXL8MSG | dewar-translation-message | ascii string |
| DEIMOT.DWXL8NAM | dewar-translation-named-position | ascii string |
| DEIMOT.DWXL8ORD | dewar-translation-ordinal-position | integer |
| DEIMOT.DWXL8RAW | dewar-translation-raw-position | integer |
| DEIMOT.DWXL8SPD | dewar-translation-speed | integer |
| DEIMOT.DWXL8STA | dewar-translation-status | enumerated integer |
| DEIMOT.DWXL8TOR | dewar-translation-torque | real number |
| DEIMOT.DWXL8TRG | dewar-translation-raw-position-target | integer |
| DEIMOT.DWXL8TSP | dewar-translation-speed-target | integer |
| DEIMOT.DWXL8VAL | dewar-translation-value | real number |
| DEIMOT.DWXL8VEL | dewar-translation-velocity | real number |
| DEIMOT.DWXL8VRB | dewar-translation-verbose-messages | logical |
| DEIMOT.FLAMP1 | flexure-compensation-system-lamp-1 | logical |
| DEIMOT.FLAMP2 | flexure-compensation-system-lamp-2 | logical |
| DEIMOT.FLAMP3 | flexure-compensation-system-lamp-3 | logical |
| DEIMOT.FLAMPDMP | fcs-lamp-dump | logical |
| DEIMOT.FLAMPERR | fcs-lamps-error-number | integer |
| DEIMOT.FLAMPLIS | fcs-lamps-inventory | ascii string |
| DEIMOT.FLAMPMSG | fcs-lamps-message | ascii string |
| DEIMOT.FLAMPOFF | fcs-lamps-off | ascii string |
| DEIMOT.FLAMPON | fcs-lamps-on | ascii string |
| DEIMOT.FLAMPS | fcs-lamps-lit | ascii string |
| DEIMOT.FOCUSDIF | focus-offset-position-error | real number |
| DEIMOT.FOCUSDMP | focus-dump | logical |
| DEIMOT.FOCUSERR | focus-error-number | integer |
| DEIMOT.FOCUSMOD | focus-control-mode | enumerated integer |
| DEIMOT.FOCUSMSG | focus-message | ascii string |
| DEIMOT.FOCUSOFF | focus-offset | real number |
| DEIMOT.FOCUSRAW | focus-raw | integer |
| DEIMOT.FOCUSRIF | focus-offset-raw-position-error | integer |
| DEIMOT.FOCUSROF | focus-raw-offset | integer |
| DEIMOT.FOCUSRUS | focus-raw-user-offset | integer |
| DEIMOT.FOCUSSTA | focus-control-status | enumerated integer |
| DEIMOT.FOCUSTOF | focus-target-offset | integer |
| DEIMOT.FOCUSTRG | focus-target | integer |
| DEIMOT.FOCUSTUS | focus-target-user-offset | integer |
| DEIMOT.FOCUSUSR | focus-user-offset | real number |
| DEIMOT.FOCUSVAL | focus-value | real number |
| DEIMOT.FOCUSVRB | focus-verbose-messages | logical |
| DEIMOT.G1TLTCAL | grating-1-tilt-calibration | logical |
| DEIMOT.G1TLTDMP | grating-1-tilt-dump | logical |
| DEIMOT.G1TLTENC | grating-1-tilt-motor-encoder-position | integer |
| DEIMOT.G1TLTERR | grating-1-tilt-error-number | integer |
| DEIMOT.G1TLTFIP | grating-1-tilt-fiducial-light-sensor | logical |
| DEIMOT.G1TLTFOP | grating-1-tilt-fiducial-light-source | logical |
| DEIMOT.G1TLTLCK | grating-1-tilt-lock | ascii string |
| DEIMOT.G1TLTLIM | grating-1-tilt-limits | enumerated integer |
| DEIMOT.G1TLTMOD | grating-1-tilt-control-mode | enumerated integer |
| DEIMOT.G1TLTMSG | grating-1-tilt-message | ascii string |
| DEIMOT.G1TLTNAM | grating-1-tilt-named-position | ascii string |
| DEIMOT.G1TLTNOM | grating-1-tilt-nominal-position | integer |
| DEIMOT.G1TLTOFF | grating-1-tilt-nominal-offset | integer |
| DEIMOT.G1TLTORD | grating-1-tilt-ordinal-position | integer |
| DEIMOT.G1TLTRAW | grating-1-tilt-raw-position | integer |
| DEIMOT.G1TLTSPD | grating-1-tilt-speed | integer |
| DEIMOT.G1TLTSTA | grating-1-tilt-status | enumerated integer |
| DEIMOT.G1TLTTOR | grating-1-tilt-torque | real number |
| DEIMOT.G1TLTTRG | grating-1-tilt-raw-position-target | integer |
| DEIMOT.G1TLTTSP | grating-1-tilt-speed-target | integer |
| DEIMOT.G1TLTVAL | grating-1-tilt-value | real number |
| DEIMOT.G1TLTVRB | grating-1-tilt-verbose-messages | logical |
| DEIMOT.G1TLTWAV | grating-1-tilt-wavelength | real number |
| DEIMOT.G3TLTCAL | grating-3-tilt-calibration | logical |
| DEIMOT.G3TLTDMP | grating-3-tilt-dump | logical |
| DEIMOT.G3TLTENC | grating-3-tilt-motor-encoder-position | integer |
| DEIMOT.G3TLTERR | grating-3-tilt-error-number | integer |
| DEIMOT.G3TLTFIP | grating-3-tilt-fiducial-light-sensor | logical |
| DEIMOT.G3TLTFOP | grating-3-tilt-fiducial-light-source | logical |
| DEIMOT.G3TLTLCK | grating-3-tilt-lock | ascii string |
| DEIMOT.G3TLTLIM | grating-3-tilt-limits | enumerated integer |
| DEIMOT.G3TLTMOD | grating-3-tilt-control-mode | enumerated integer |
| DEIMOT.G3TLTMSG | grating-3-tilt-message | ascii string |
| DEIMOT.G3TLTNAM | grating-3-tilt-named-position | ascii string |
| DEIMOT.G3TLTNOM | grating-3-tilt-nominal-position | integer |
| DEIMOT.G3TLTOFF | grating-3-tilt-nominal-offset | integer |
| DEIMOT.G3TLTORD | grating-3-tilt-ordinal-position | integer |
| DEIMOT.G3TLTRAW | grating-3-tilt-raw-position | integer |
| DEIMOT.G3TLTSPD | grating-3-tilt-speed | integer |
| DEIMOT.G3TLTSTA | grating-3-tilt-status | enumerated integer |
| DEIMOT.G3TLTTOR | grating-3-tilt-torque | real number |
| DEIMOT.G3TLTTRG | grating-3-tilt-raw-position-target | integer |
| DEIMOT.G3TLTTSP | grating-3-tilt-speed-target | integer |
| DEIMOT.G3TLTVAL | grating-3-tilt-value | real number |
| DEIMOT.G3TLTVRB | grating-3-tilt-verbose-messages | logical |
| DEIMOT.G3TLTWAV | grating-3-tilt-wavelength | real number |
| DEIMOT.G4TLTCAL | grating-4-tilt-calibration | logical |
| DEIMOT.G4TLTDMP | grating-4-tilt-dump | logical |
| DEIMOT.G4TLTENC | grating-4-tilt-motor-encoder-position | integer |
| DEIMOT.G4TLTERR | grating-4-tilt-error-number | integer |
| DEIMOT.G4TLTFIP | grating-4-tilt-fiducial-light-sensor | logical |
| DEIMOT.G4TLTFOP | grating-4-tilt-fiducial-light-source | logical |
| DEIMOT.G4TLTLCK | grating-4-tilt-lock | ascii string |
| DEIMOT.G4TLTLIM | grating-4-tilt-limits | enumerated integer |
| DEIMOT.G4TLTMOD | grating-4-tilt-control-mode | enumerated integer |
| DEIMOT.G4TLTMSG | grating-4-tilt-message | ascii string |
| DEIMOT.G4TLTNAM | grating-4-tilt-named-position | ascii string |
| DEIMOT.G4TLTNOM | grating-4-tilt-nominal-position | integer |
| DEIMOT.G4TLTOFF | grating-4-tilt-nominal-offset | integer |
| DEIMOT.G4TLTORD | grating-4-tilt-ordinal-position | integer |
| DEIMOT.G4TLTRAW | grating-4-tilt-raw-position | integer |
| DEIMOT.G4TLTSPD | grating-4-tilt-speed | integer |
| DEIMOT.G4TLTSTA | grating-4-tilt-status | enumerated integer |
| DEIMOT.G4TLTTOR | grating-4-tilt-torque | real number |
| DEIMOT.G4TLTTRG | grating-4-tilt-raw-position-target | integer |
| DEIMOT.G4TLTTSP | grating-4-tilt-speed-target | integer |
| DEIMOT.G4TLTVAL | grating-4-tilt-value | real number |
| DEIMOT.G4TLTVRB | grating-4-tilt-verbose-messages | logical |
| DEIMOT.G4TLTWAV | grating-4-tilt-wavelength | real number |
| DEIMOT.GCLP1DMP | grating-clamp-1-dump | logical |
| DEIMOT.GCLP1ERR | grating-clamp-1-error-number | integer |
| DEIMOT.GCLP1LCK | grating-clamp-1-lock | ascii string |
| DEIMOT.GCLP1MSG | grating-clamp-1-message | ascii string |
| DEIMOT.GCLP1POS | grating-clamp-1-position | enumerated integer |
| DEIMOT.GCLP1STA | grating-clamp-1-status | enumerated integer |
| DEIMOT.GCLP1TRG | grating-clamp-1-target | enumerated integer |
| DEIMOT.GCLP1VRB | grating-clamp-1-verbose-messages | logical |
| DEIMOT.GCLP2DMP | grating-clamp-2-dump | logical |
| DEIMOT.GCLP2ERR | grating-clamp-2-error-number | integer |
| DEIMOT.GCLP2LCK | grating-clamp-2-lock | ascii string |
| DEIMOT.GCLP2MSG | grating-clamp-2-message | ascii string |
| DEIMOT.GCLP2POS | grating-clamp-2-position | enumerated integer |
| DEIMOT.GCLP2STA | grating-clamp-2-status | enumerated integer |
| DEIMOT.GCLP2TRG | grating-clamp-2-target | enumerated integer |
| DEIMOT.GCLP2VRB | grating-clamp-2-verbose-messages | logical |
| DEIMOT.GCLP4DMP | grating-clamp-4-dump | logical |
| DEIMOT.GCLP4ERR | grating-clamp-4-error-number | integer |
| DEIMOT.GCLP4LCK | grating-clamp-4-lock | ascii string |
| DEIMOT.GCLP4MSG | grating-clamp-4-message | ascii string |
| DEIMOT.GCLP4POS | grating-clamp-4-position | enumerated integer |
| DEIMOT.GCLP4STA | grating-clamp-4-status | enumerated integer |
| DEIMOT.GCLP4TRG | grating-clamp-4-target | enumerated integer |
| DEIMOT.GCLP4VRB | grating-clamp-4-verbose-messages | logical |
| DEIMOT.GCLP5DMP | grating-clamp-5-dump | logical |
| DEIMOT.GCLP5ERR | grating-clamp-5-error-number | integer |
| DEIMOT.GCLP5LCK | grating-clamp-5-lock | ascii string |
| DEIMOT.GCLP5MSG | grating-clamp-5-message | ascii string |
| DEIMOT.GCLP5POS | grating-clamp-5-position | enumerated integer |
| DEIMOT.GCLP5STA | grating-clamp-5-status | enumerated integer |
| DEIMOT.GCLP5TRG | grating-clamp-5-target | enumerated integer |
| DEIMOT.GCLP5VRB | grating-clamp-5-verbose-messages | logical |
| DEIMOT.GRATEDMP | grating-dump | logical |
| DEIMOT.GRATEERR | grating-error-number | integer |
| DEIMOT.GRATEFOP | grating-slider-prm-tab-fiducial-light-source | logical |
| DEIMOT.GRATELCK | grating-lock | ascii string |
| DEIMOT.GRATEMSG | grating-message | ascii string |
| DEIMOT.GRATENAM | grating-named-position | ascii string |
| DEIMOT.GRATEPIN | grating-pin | logical |
| DEIMOT.GRATEPOS | grating-position | integer |
| DEIMOT.GRATERUL | grating-ruling | integer |
| DEIMOT.GRATESTA | grating-status | enumerated integer |
| DEIMOT.GRATETRG | grating-target | integer |
| DEIMOT.GRATEVRB | grating-verbose-messages | logical |
| DEIMOT.GRATLIN1 | grating-lines-slider-1 | integer |
| DEIMOT.GRATLIN2 | grating-lines-slider-2 | integer |
| DEIMOT.GRATLIN3 | grating-lines-slider-3 | integer |
| DEIMOT.GRATLIN4 | grating-lines-slider-4 | integer |
| DEIMOT.GRATOFF1 | grating-prm-offset-1 | integer |
| DEIMOT.GRATOFF2 | grating-prm-offset-2 | integer |
| DEIMOT.GRATOFF3 | grating-prm-offset-3 | integer |
| DEIMOT.GRATOFF4 | grating-prm-offset-4 | integer |
| DEIMOT.GRATTAB1 | grating-prm-tab-position-1 | integer |
| DEIMOT.GRATTAB2 | grating-prm-tab-position-2 | integer |
| DEIMOT.GRATTAB3 | grating-prm-tab-position-3 | integer |
| DEIMOT.GRATTAB4 | grating-prm-tab-position-4 | integer |
| DEIMOT.GRHATCH1 | grating-hatch-1 | logical |
| DEIMOT.GRHATCH2 | grating-hatch-2 | logical |
| DEIMOT.GRIPLED1 | grating-system-in-unload-position-led-1 | logical |
| DEIMOT.GRIPLED2 | grating-system-in-unload-position-led-2 | logical |
| DEIMOT.GRMVLED | grating-system-moving-led | logical |
| DEIMOT.GRSELCAL | grating-selector-calibration | logical |
| DEIMOT.GRSELDMP | grating-selector-dump | logical |
| DEIMOT.GRSELERR | grating-selector-error-number | integer |
| DEIMOT.GRSELFIP | grating-selector-fiducial-light-sensor | logical |
| DEIMOT.GRSELFOP | grating-selector-fiducial-light-source | logical |
| DEIMOT.GRSELLCK | grating-selector-lock | ascii string |
| DEIMOT.GRSELLIM | grating-selector-limits | enumerated integer |
| DEIMOT.GRSELMOD | grating-selector-control-mode | enumerated integer |
| DEIMOT.GRSELMSG | grating-selector-message | ascii string |
| DEIMOT.GRSELNAM | grating-selector-named-position | ascii string |
| DEIMOT.GRSELORD | grating-selector-ordinal-position | integer |
| DEIMOT.GRSELRAW | grating-selector-raw-position | integer |
| DEIMOT.GRSELSPD | grating-selector-speed | integer |
| DEIMOT.GRSELSTA | grating-selector-status | enumerated integer |
| DEIMOT.GRSELTOR | grating-selector-torque | real number |
| DEIMOT.GRSELTRG | grating-selector-raw-position-target | integer |
| DEIMOT.GRSELTSP | grating-selector-speed-target | integer |
| DEIMOT.GRSELVAL | grating-selector-value | real number |
| DEIMOT.GRSELVEL | grating-selector-velocity | real number |
| DEIMOT.GRSELVRB | grating-selector-verbose-messages | logical |
| DEIMOT.GRT1BUT | manual-control-unload-grating-1-button | logical |
| DEIMOT.GRT3BUT | manual-control-unload-grating-3-button | logical |
| DEIMOT.GRT4BUT | manual-control-unload-grating-4-button | logical |
| DEIMOT.GRTSBUT | grating-manual-control-stop-button | logical |
| DEIMOT.HATCHDMP | hatch-dump | logical |
| DEIMOT.HATCHERR | hatch-error-number | integer |
| DEIMOT.HATCHLCK | hatch-lock | ascii string |
| DEIMOT.HATCHMSG | hatch-message | ascii string |
| DEIMOT.HATCHPOS | hatch-position | enumerated integer |
| DEIMOT.HATCHSTA | hatch-status | enumerated integer |
| DEIMOT.HATCHTRG | hatch-target | enumerated integer |
| DEIMOT.HATCHVRB | hatch-verbose-messages | logical |
| DEIMOT.HPLOGPER | ?? | integer
|
| DEIMOT.HPLOGSCN | HP-sensor-scan | logical |
| DEIMOT.HPLOGTIM | ?? | ascii string
|
| DEIMOT.ION1UAMP | dewar-ion-pump-current-microamps | real number |
| DEIMOT.ION1VOLT | dewar-ion-pump-current-signal-voltage | real number |
| DEIMOT.ION2UAMP | vessel-ion-pump-current-microamps | real number |
| DEIMOT.ION2VOLT | vessel-ion-pump-current-signal-voltage | real number |
| DEIMOT.IONPUMP1 | dewar-ion-pump-state | enumerated integer |
| DEIMOT.IONPUMP2 | vessel-ion-pump-state | enumerated integer |
| DEIMOT.KILLPOW | kill-ac-power-to-ring | logical |
| DEIMOT.LAMP1 | lamp-1 | logical |
| DEIMOT.LAMP2 | lamp-2 | logical |
| DEIMOT.LAMP3 | lamp-3 | logical |
| DEIMOT.LAMP4 | lamp-4 | logical |
| DEIMOT.LAMP5 | lamp-5 | logical |
| DEIMOT.LAMP6 | lamp-6 | logical |
| DEIMOT.LAMP7 | lamp-7 | logical |
| DEIMOT.LAMP8 | lamp-8 | logical |
| DEIMOT.LAMPDMP | lamp-dump | logical |
| DEIMOT.LAMPERR | comparison-lamps-error-number | integer |
| DEIMOT.LAMPLIST | comparison-lamps-inventory | ascii string |
| DEIMOT.LAMPLOCK | lamp-interlock | logical |
| DEIMOT.LAMPMSG | comparison-lamps-message | ascii string |
| DEIMOT.LAMPOFF | comparison-lamps-off | ascii string |
| DEIMOT.LAMPON | comparison-lamps-on | ascii string |
| DEIMOT.LAMPS | comparison-lamps-lit | ascii string |
| DEIMOT.MAN1FBUT | controller-1-manual-control-forward-button | logical |
| DEIMOT.MAN1FLED | manual-paddle-1-forward-limit-led | logical |
| DEIMOT.MAN1MLED | manual-paddle-1-moving-led | logical |
| DEIMOT.MAN1MOD0 | controller-1-manual-control-mode-bit-0 | logical |
| DEIMOT.MAN1MOD1 | controller-1-manual-control-mode-bit-1 | logical |
| DEIMOT.MAN1MOD2 | controller-1-manual-control-mode-bit-2 | logical |
| DEIMOT.MAN1RBUT | controller-1-manual-control-reverse-button | logical |
| DEIMOT.MAN1RLED | manual-paddle-1-reverse-limit-led | logical |
| DEIMOT.MAN1SBUT | controller-1-manual-control-stop-button | logical |
| DEIMOT.MAN1SEL0 | controller-1-manual-control-select-bit-0 | logical |
| DEIMOT.MAN1SEL1 | controller-1-manual-control-select-bit-1 | logical |
| DEIMOT.MAN1SEL2 | controller-1-manual-control-select-bit-2 | logical |
| DEIMOT.MAN1TGL1 | controller-1-manual-control-toggle-bit-1 | logical |
| DEIMOT.MAN1TGL2 | controller-1-manual-control-toggle-bit-2 | logical |
| DEIMOT.MAN2FBUT | controller-2-manual-control-forward-button | logical |
| DEIMOT.MAN2FLED | manual-paddle-2-forward-limit-led | logical |
| DEIMOT.MAN2MLED | manual-paddle-2-moving-led | logical |
| DEIMOT.MAN2MOD0 | controller-2-manual-control-mode-bit-0 | logical |
| DEIMOT.MAN2MOD1 | controller-2-manual-control-mode-bit-1 | logical |
| DEIMOT.MAN2MOD2 | controller-2-manual-control-mode-bit-2 | logical |
| DEIMOT.MAN2RBUT | controller-2-manual-control-reverse-button | logical |
| DEIMOT.MAN2RLED | manual-paddle-2-reverse-limit-led | logical |
| DEIMOT.MAN2SBUT | controller-2-manual-control-stop-button | logical |
| DEIMOT.MAN2SEL0 | controller-2-manual-control-select-bit-0 | logical |
| DEIMOT.MAN2SEL1 | controller-2-manual-control-select-bit-1 | logical |
| DEIMOT.MAN2SEL2 | controller-2-manual-control-select-bit-2 | logical |
| DEIMOT.MAN2TGL1 | controller-2-manual-control-toggle-bit-1 | logical |
| DEIMOT.MAN2TGL2 | controller-2-manual-control-toggle-bit-2 | logical |
| DEIMOT.MANHATCH | man-hatch | logical |
| DEIMOT.MANU1CON | controller-1-manual-control-switch-state | logical |
| DEIMOT.MANU2CON | controller-2-manual-control-switch-state | logical |
| DEIMOT.MSKBAR10 | slitmask-barcode-10 | ascii string |
| DEIMOT.MSKBAR11 | slitmask-barcode-11 | ascii string |
| DEIMOT.MSKBAR12 | slitmask-barcode-12 | ascii string |
| DEIMOT.MSKBAR2 | slitmask-barcode-2 | ascii string |
| DEIMOT.MSKBAR3 | slitmask-barcode-3 | ascii string |
| DEIMOT.MSKBAR4 | slitmask-barcode-4 | ascii string |
| DEIMOT.MSKBAR5 | slitmask-barcode-5 | ascii string |
| DEIMOT.MSKBAR6 | slitmask-barcode-6 | ascii string |
| DEIMOT.MSKBAR7 | slitmask-barcode-7 | ascii string |
| DEIMOT.MSKBAR8 | slitmask-barcode-8 | ascii string |
| DEIMOT.MSKBAR9 | slitmask-barcode-9 | ascii string |
| DEIMOT.POW05S1V | motor-controller-1-electronics-5-volt-power-supply-voltage | real number |
| DEIMOT.POW05S2V | motor-controller-2-electronics-5-volt-power-supply-voltage | real number |
| DEIMOT.POW12S1R | motor-controller-1-electronics-12-volt-power-raw | real number |
| DEIMOT.POW12S2R | motor-controller-2-electronics-12-volt-power-raw | real number |
| DEIMOT.POW28S1R | motor-controller-1-electronics-28-volt-power-raw | real number |
| DEIMOT.POW28S1V | motor-controller-1-electronics-28-volt-power-supply-voltage | real number |
| DEIMOT.POW28S2R | motor-controller-2-electronics-28-volt-power-raw | real number |
| DEIMOT.POW28S2V | motor-controller-1-electronics-28-volt-power-supply-voltage | real number |
| DEIMOT.SLARMDMP | slitmask-arm-dump | logical |
| DEIMOT.SLARMERR | slitmask-arm-error-number | integer |
| DEIMOT.SLARMLCK | slitmask-arm-lock | ascii string |
| DEIMOT.SLARMMSG | slitmask-arm-message | ascii string |
| DEIMOT.SLARMPOS | slitmask-arm-position | enumerated integer |
| DEIMOT.SLARMSTA | slitmask-arm-status | enumerated integer |
| DEIMOT.SLARMTRG | slitmask-arm-target | enumerated integer |
| DEIMOT.SLARMVRB | slitmask-arm-verbose-messages | logical |
| DEIMOT.SLBARCFG | slitmask-bar-code-reader-configuration | ascii string |
| DEIMOT.SLBARCMD | slitmask-bar-code-reader-command | ascii string |
| DEIMOT.SLBARERR | ?? | integer
|
| DEIMOT.SLBARGET | slitmask-bar-code | ascii string |
| DEIMOT.SLBARRSP | slitmask-bar-code-reader-response | ascii string |
| DEIMOT.SLBARSCN | slitmask-bar-code-scan | logical |
| DEIMOT.SLMHATCH | slitmask-hatch | logical |
| DEIMOT.SLMIPLED | slitmask-system-in-unload-position-led | logical |
| DEIMOT.SLMMVLED | slitmask-system-moving-led | logical |
| DEIMOT.SLMSBUT | slitmask-manual-control-stop-button | logical |
| DEIMOT.SLMSKALI | slitmasks-aligned-fiducial | logical |
| DEIMOT.SLMSKAT1 | slitmask-at-place-1-fiducial | logical |
| DEIMOT.SLMSKAT2 | slitmask-at-place-2-fiducial | logical |
| DEIMOT.SLMSKBAR | slitmask-barcode | ascii string |
| DEIMOT.SLMSKCAS | slitmask-cassette-door-state | logical |
| DEIMOT.SLMSKCMB | slitmask-misaligned-fiducial | logical |
| DEIMOT.SLMSKDMP | slitmask-dump | logical |
| DEIMOT.SLMSKEND | slitmask-at-end-of-travel-fiducial | logical |
| DEIMOT.SLMSKERR | slitmask-error-number | integer |
| DEIMOT.SLMSKFOO | slitmask-foot-state | logical |
| DEIMOT.SLMSKFOP | slitmask-position-fiducial-light-source | logical |
| DEIMOT.SLMSKLCK | slitmask-lock | ascii string |
| DEIMOT.SLMSKLOC | slitmask-location | enumerated integer |
| DEIMOT.SLMSKMAL | slitmask-misaligned | logical |
| DEIMOT.SLMSKMSG | slitmask-message | ascii string |
| DEIMOT.SLMSKNAM | slitmask-named-position | ascii string |
| DEIMOT.SLMSKPOS | slitmask-position | integer |
| DEIMOT.SLMSKSTA | slitmask-status | enumerated integer |
| DEIMOT.SLMSKTRG | slitmask-target | integer |
| DEIMOT.SLMSKVRB | slitmask-verbose-messages | logical |
| DEIMOT.SLMULBUT | slitmask-manual-control-unload-button | logical |
| DEIMOT.SLSELCAL | slitmask-selector-calibration | logical |
| DEIMOT.SLSELDMP | slitmask-selector-dump | logical |
| DEIMOT.SLSELERR | slitmask-selector-error-number | integer |
| DEIMOT.SLSELFIP | slitmask-selector-fiducial-light-sensor | logical |
| DEIMOT.SLSELFOP | slitmask-selector-fiducial-light-source | logical |
| DEIMOT.SLSELLCK | slitmask-selector-lock | ascii string |
| DEIMOT.SLSELLIM | slitmask-selector-limits | enumerated integer |
| DEIMOT.SLSELMOD | slitmask-selector-control-mode | enumerated integer |
| DEIMOT.SLSELMSG | slitmask-selector-message | ascii string |
| DEIMOT.SLSELNAM | slitmask-selector-named-position | ascii string |
| DEIMOT.SLSELORD | slitmask-selector-ordinal-position | integer |
| DEIMOT.SLSELRAW | slitmask-selector-raw-position | integer |
| DEIMOT.SLSELSPD | slitmask-selector-speed | integer |
| DEIMOT.SLSELSTA | slitmask-selector-status | enumerated integer |
| DEIMOT.SLSELTOR | slitmask-selector-torque | real number |
| DEIMOT.SLSELTRG | slitmask-selector-raw-position-target | integer |
| DEIMOT.SLSELTSP | slitmask-selector-speed-target | integer |
| DEIMOT.SLSELVAL | slitmask-selector-value | real number |
| DEIMOT.SLSELVEL | slitmask-selector-velocity | real number |
| DEIMOT.SLSELVRB | slitmask-selector-verbose-messages | logical |
| DEIMOT.TBAR1RAW | ?? | real number
|
| DEIMOT.TBAR1VAL | ?? | real number
|
| DEIMOT.TBAR2RAW | ?? | real number
|
| DEIMOT.TBAR2VAL | ?? | real number
|
| DEIMOT.TBAR3RAW | ?? | real number
|
| DEIMOT.TBAR3VAL | ?? | real number
|
| DEIMOT.TBAR4RAW | ?? | real number
|
| DEIMOT.TBAR4VAL | ?? | real number
|
| DEIMOT.TBAR5RAW | ?? | real number
|
| DEIMOT.TBAR5VAL | ?? | real number
|
| DEIMOT.TBAR6RAW | ?? | real number
|
| DEIMOT.TBAR6VAL | ?? | real number
|
| DEIMOT.TBAR7RAW | ?? | real number
|
| DEIMOT.TBAR7VAL | ?? | real number
|
| DEIMOT.TBAR8RAW | ?? | real number
|
| DEIMOT.TBAR8VAL | ?? | real number
|
| DEIMOT.TCAM1RAW | ?? | real number
|
| DEIMOT.TCAM1VAL | ?? | real number
|
| DEIMOT.TCAM2RAW | ?? | real number
|
| DEIMOT.TCAM2VAL | ?? | real number
|
| DEIMOT.TCAM3RAW | ?? | real number
|
| DEIMOT.TCAM3VAL | ?? | real number
|
| DEIMOT.TCAM4RAW | ?? | real number
|
| DEIMOT.TCAM4VAL | ?? | real number
|
| DEIMOT.TCAM5RAW | ?? | real number
|
| DEIMOT.TCAM5VAL | ?? | real number
|
| DEIMOT.TCAM6RAW | ?? | real number
|
| DEIMOT.TCAM6VAL | ?? | real number
|
| DEIMOT.TCAM7RAW | ?? | real number
|
| DEIMOT.TCAM7VAL | ?? | real number
|
| DEIMOT.TCAM8RAW | ?? | real number
|
| DEIMOT.TCAM8VAL | ?? | real number
|
| DEIMOT.TDIS1RAW | ?? | real number
|
| DEIMOT.TDIS1VAL | ?? | real number
|
| DEIMOT.TDIS2RAW | ?? | real number
|
| DEIMOT.TDIS2VAL | ?? | real number
|
| DEIMOT.TDIS3RAW | ?? | real number
|
| DEIMOT.TDIS3VAL | ?? | real number
|
| DEIMOT.TDIS4RAW | ?? | real number
|
| DEIMOT.TDIS4VAL | ?? | real number
|
| DEIMOT.TDIS5RAW | ?? | real number
|
| DEIMOT.TDIS5VAL | ?? | real number
|
| DEIMOT.TDIS6RAW | ?? | real number
|
| DEIMOT.TDIS6VAL | ?? | real number
|
| DEIMOT.TDIS7RAW | ?? | real number
|
| DEIMOT.TDIS7VAL | ?? | real number
|
| DEIMOT.TDIS8RAW | ?? | real number
|
| DEIMOT.TDIS8VAL | ?? | real number
|
| DEIMOT.TGRA1RAW | ?? | real number
|
| DEIMOT.TGRA1VAL | ?? | real number
|
| DEIMOT.TGRA2RAW | ?? | real number
|
| DEIMOT.TGRA2VAL | ?? | real number
|
| DEIMOT.TGRA3RAW | ?? | real number
|
| DEIMOT.TGRA3VAL | ?? | real number
|
| DEIMOT.TMIRRCMD | direct-piezo-command | ascii string |
| DEIMOT.TMIRRERR | tent-mirror-error-number | ascii string |
| DEIMOT.TMIRRLCK | tent-mirror-translation-lock | ascii string |
| DEIMOT.TMIRRMSG | tent-mirror-translation-message | ascii string |
| DEIMOT.TMIRRNAM | tent-mirror-translation-named-position | ascii string |
| DEIMOT.TMIRRORD | tent-mirror-translation-ordinal-position | integer |
| DEIMOT.TMIRRRAW | tent-mirror-translation-raw-position | integer |
| DEIMOT.TMIRRSTA | tent-mirror-status | enumerated integer |
| DEIMOT.TMIRRTRG | tent-mirror-translation-raw-position-target | integer |
| DEIMOT.TMIRRVAL | tent-mirror-translation-value | real number |
| DEIMOT.TMIRRVER | piezo-version-ID | ascii string |
| DEIMOT.TMIRRVRB | tent-mirror-verbose-messages | logical |
| DEIMOT.TMPBOX1C | electronics-ring-temperature-1-celsius | real number |
| DEIMOT.TMPBOX1F | electronics-ring-temperature-1-fahrenheit | real number |
| DEIMOT.TMPBOX1R | electronics-ring-temperature-1-raw | real number |
| DEIMOT.TMPBOX2C | electronics-ring-temperature-2-celsius | real number |
| DEIMOT.TMPBOX2F | electronics-ring-temperature-2-fahrenheit | real number |
| DEIMOT.TMPBOX2R | electronics-ring-temperature-2-raw | real number |
| DEIMOT.TMPCOOLC | coolant-temperature-celsius | real number |
| DEIMOT.TMPCOOLF | coolant-temperature-fahrenheit | real number |
| DEIMOT.TMPCOOLR | coolant-temperature-raw | real number |
| DEIMOT.TMPELE1C | motor-controller-1-electronics-temperature-celsius | real number |
| DEIMOT.TMPELE1F | motor-controller-1-electronics-temperature-fahrenheit | real number |
| DEIMOT.TMPELE1R | motor-controller-1-electronics-temperature-raw | real number |
| DEIMOT.TMPELE2C | motor-controller-2-electronics-temperature-celsius | real number |
| DEIMOT.TMPELE2F | motor-controller-2-electronics-temperature-fahrenheit | real number |
| DEIMOT.TMPELE2R | motor-controller-2-electronics-temperature-raw | real number |
| DEIMOT.TMPTVCOC | pxl-camera-coolant-temperature-celsius | real number |
| DEIMOT.TMPTVCOF | pxl-camera-coolant-temperature-fahrenheit | real number |
| DEIMOT.TMPTVCOR | pxl-camera-coolant-temperature-raw | real number |
| DEIMOT.TVA2SPOW | tv-a2i-to-scsi-power | logical |
| DEIMOT.TVCAMPOW | tv-camera-power | logical |
| DEIMOT.TVCOFLOW | pxl-camera-coolant-flow | logical |
| DEIMOT.TVFILCAL | tv-filter-calibration | logical |
| DEIMOT.TVFILDMP | tv-filter-dump | logical |
| DEIMOT.TVFILERR | tv-filter-error-number | integer |
| DEIMOT.TVFILFIP | tv-filter-fiducial-light-sensor | logical |
| DEIMOT.TVFILFOP | tv-filter-fiducial-light-source | logical |
| DEIMOT.TVFILLCK | tv-filter-lock | ascii string |
| DEIMOT.TVFILMOD | tv-filter-control-mode | enumerated integer |
| DEIMOT.TVFILMSG | tv-filter-message | ascii string |
| DEIMOT.TVFILNAM | tv-filter-named-position | ascii string |
| DEIMOT.TVFILORD | tv-filter-ordinal-position | integer |
| DEIMOT.TVFILRAW | tv-filter-raw-position | integer |
| DEIMOT.TVFILSPD | tv-filter-speed | integer |
| DEIMOT.TVFILSTA | tv-filter-status | enumerated integer |
| DEIMOT.TVFILTOR | tv-filter-torque | real number |
| DEIMOT.TVFILTRG | tv-filter-raw-position-target | integer |
| DEIMOT.TVFILTSP | tv-filter-speed-target | integer |
| DEIMOT.TVFILVAL | tv-filter-value | real number |
| DEIMOT.TVFILVEL | tv-filter-velocity | real number |
| DEIMOT.TVFILVRB | tv-filter-verbose-messages | logical |
| DEIMOT.TVFOCCAL | tv-focus-calibration | logical |
| DEIMOT.TVFOCDMP | tv-focus-dump | logical |
| DEIMOT.TVFOCERR | tv-focus-error-number | integer |
| DEIMOT.TVFOCFIP | tv-focus-fiducial-light-sensor | logical |
| DEIMOT.TVFOCFOP | tv-focus-fiducial-light-source | logical |
| DEIMOT.TVFOCLCK | tv-focus-lock | ascii string |
| DEIMOT.TVFOCLIM | tv-focus-limits | enumerated integer |
| DEIMOT.TVFOCMOD | tv-focus-control-mode | enumerated integer |
| DEIMOT.TVFOCMSG | tv-focus-message | ascii string |
| DEIMOT.TVFOCNAM | tv-focus-named-position | ascii string |
| DEIMOT.TVFOCORD | tv-focus-ordinal-position | integer |
| DEIMOT.TVFOCRAW | tv-focus-raw-position | integer |
| DEIMOT.TVFOCSPD | tv-focus-speed | integer |
| DEIMOT.TVFOCSTA | tv-focus-status | enumerated integer |
| DEIMOT.TVFOCTOR | tv-focus-torque | real number |
| DEIMOT.TVFOCTRG | tv-focus-raw-position-target | integer |
| DEIMOT.TVFOCTSP | tv-focus-speed-target | integer |
| DEIMOT.TVFOCVAL | tv-focus-value | real number |
| DEIMOT.TVFOCVEL | tv-focus-velocity | real number |
| DEIMOT.TVFOCVRB | tv-focus-verbose-messages | logical |
| DEIMOT.TVPOWDMP | tv-camera-system-power-dump | logical |
| DEIMOT.TVPOWERR | tv-camera-system-power-error-number | integer |
| DEIMOT.TVPOWLCK | tv-camera-system-power-lock | ascii string |
| DEIMOT.TVPOWMSG | tv-camera-system-power-message | ascii string |
| DEIMOT.TVPOWSET | tv-camera-system-power-setting | logical |
| DEIMOT.TVPOWSTA | tv-camera-system-power-status | enumerated integer |
| DEIMOT.TVPOWTRG | tv-camera-system-power-target | logical |
| DEIMOT.TVPOWVRB | tv-camera-system-power-verbose-messages | logical |
| DEIMOT.TVS2FPOW | tv-scsi-to-fiber-power | logical |
| Keywords from the DEIROT library |
| DEIROT.AIRPRESS | cradle-air-pressure-status | logical |
| DEIROT.BAYBFAN | cradle-bays-a-and-b-fans | logical |
| DEIROT.BAYCFAN | cradle-bays-c-and-d-fans | logical |
| DEIROT.COOLFLOW | cradle-coolant-flow | logical |
| DEIROT.DISP6BAZ | rotator-motionalarm-bit | ascii string |
| DEIROT.DISP6BCI | rotator-broadcast-interval | integer |
| DEIROT.DISP6BTI | rotator-fast-broadcast-time | integer |
| DEIROT.DISP6BUZ | rotator-movewarn-bit | ascii string |
| DEIROT.DISP6DBG | rotator-debug-level | integer |
| DEIROT.DISP6DMP | dispatcher-6-dump | ascii string |
| DEIROT.DISP6DWIM | dispatcher-6-do-what-i-mean | ascii string |
| DEIROT.DISP6LOG | rotator-log-file | ascii string |
| DEIROT.DISP6LTO | rotator-fastlog-timeout | integer |
| DEIROT.DISP6LVL | rotator-log-level | integer |
| DEIROT.DISP6RTI | rotator-run-track-invocations | integer |
| DEIROT.DISP6RTL | rotator-run-track-late-calls | integer |
| DEIROT.DISP6RTV | rotator-convert-raw-to-val | real number |
| DEIROT.DISP6SNDOK | rotator-sounds-ok | logical |
| DEIROT.DISP6SUF | rotator-logfile-suffix-and-trigger | integer |
| DEIROT.DISP6VTR | rotator-convert-val-to-raw | real number |
| DEIROT.POW05V | rotation-controller-electronics-5-volt-power-supply-voltage | real number |
| DEIROT.POW12R | rotation-controller-electronics-12-volt-power-raw | real number |
| DEIROT.POW48R | rotation-controller-electronics-48-volt-power-raw | real number |
| DEIROT.POW48V | rotation-controller-electronics-48-volt-power-supply-voltage | real number |
| DEIROT.ROTA1FIM | rotator-renishaw1-latch-findindex | integer |
| DEIROT.ROTA1GOF | rotator-renishaw1-gap-offset | integer |
| DEIROT.ROTA1HM | rotator-renishaw1-latch-home | integer |
| DEIROT.ROTA1IOF | rotator-renishaw1-index-offset | integer |
| DEIROT.ROTA1LTA | rotator-renishaw1-latched-raw | integer |
| DEIROT.ROTA1LTM | rotator-renishaw1-latched-modulo | integer |
| DEIROT.ROTA1QBT | rotator-ren1-quality-below-thresh | integer |
| DEIROT.ROTA1QOF | rotator-renishaw1-quality-offset | integer |
| DEIROT.ROTA1RAW | rotator-renishaw1-raw | integer |
| DEIROT.ROTA1REN | rotation-stage-encoder1-signal-quality | real number |
| DEIROT.ROTA1TOF | rotator-renishaw1-total-offset | integer |
| DEIROT.ROTA2FIM | rotator-renishaw2-latch-findindex | integer |
| DEIROT.ROTA2GOF | rotator-renishaw2-gap-offset | integer |
| DEIROT.ROTA2HM | rotator-renishaw2-latch-home | integer |
| DEIROT.ROTA2IOF | rotator-renishaw2-index-offset | integer |
| DEIROT.ROTA2LTA | rotator-renishaw2-latched-raw | integer |
| DEIROT.ROTA2LTM | rotator-renishaw2-latched-modulo | integer |
| DEIROT.ROTA2QBT | rotator-ren2-quality-below-thresh | integer |
| DEIROT.ROTA2QOF | rotator-renishaw2-quality-offset | integer |
| DEIROT.ROTA2RAW | rotator-renishaw2-raw | integer |
| DEIROT.ROTA2REN | rotation-stage-encoder2-signal-quality | real number |
| DEIROT.ROTA2TOF | rotator-renishaw2-total-offset | integer |
| DEIROT.ROTAMMAX | rotator-max-galil-position-error | real number |
| DEIROT.ROTAMMIN | rotator-min-galil-position-error | real number |
| DEIROT.ROTAMRMS | rotator-rms-galil-position-error | real number |
| DEIROT.ROTATALG | rotator-algorithm | enumerated integer |
| DEIROT.ROTATATL | rotator-at-torque-limit | integer |
| DEIROT.ROTATBRK | rotator-band-brake | logical |
| DEIROT.ROTATBYP | rotator-computer-control-bypass | logical |
| DEIROT.ROTATCAL | rotator-calibration | logical |
| DEIROT.ROTATCAP | rotator-high-speed-capture | integer |
| DEIROT.ROTATCLK | rotator-sample-clock | integer |
| DEIROT.ROTATCMT | rotator-comment | ascii string |
| DEIROT.ROTATCON | rotator-control | logical |
| DEIROT.ROTATDCI | rotator-DEIMOS-is-currinst | logical |
| DEIROT.ROTATDCS | rotator-dcs-control-permission | logical |
| DEIROT.ROTATDDR | rotator-diff-of-diffs-ren-ren | integer |
| DEIROT.ROTATDEM | rotator-dcs-roterrs-mirror | ascii string |
| DEIROT.ROTATDIS | rotator-rotation-disabled | logical |
| DEIROT.ROTATDRM | rotator-dcs-rotstat-mirror | enumerated integer bit-mask |
| DEIROT.ROTATDRR | rotator-difference-ren-ren | integer |
| DEIROT.ROTATEMS | rotator-estop | logical |
| DEIROT.ROTATENC | rotator-motor-encoder-position | integer |
| DEIROT.ROTATERR | rotator-modify-error-number | integer |
| DEIROT.ROTATEST | rotator-encoder-status | enumerated integer |
| DEIROT.ROTATFIM | rotator-find-index-motor | logical |
| DEIROT.ROTATFIP | rotator-fiducial-light-sensor | logical |
| DEIROT.ROTATFOP | rotator-fiducial-light-source | logical |
| DEIROT.ROTATHLK | rotator-hardware-lockout | logical |
| DEIROT.ROTATLCK | rotator-motion-keyword-lockout | ascii string |
| DEIROT.ROTATLIM | rotator-limits | enumerated integer |
| DEIROT.ROTATLIN | rotator-value-linear | real number |
| DEIROT.ROTATLOW | rotator-in-lowerhalf | logical |
| DEIROT.ROTATMAX | rotator-max-tracking-error | real number |
| DEIROT.ROTATMIN | rotator-min-tracking-error | real number |
| DEIROT.ROTATMOD | rotator-control-mode | enumerated integer |
| DEIROT.ROTATMSG | rotator-message | ascii string |
| DEIROT.ROTATMSP | rotator-pos-mode-speed | integer |
| DEIROT.ROTATNAM | rotator-named-position | ascii string |
| DEIROT.ROTATNRR | rotator-numchanges-ren-ren | integer |
| DEIROT.ROTATNRS | rotator-rms-duration | integer |
| DEIROT.ROTATNSJ | rotator-number-samples-jumped | integer |
| DEIROT.ROTATOE | rotator-galil-off-on-error | integer |
| DEIROT.ROTATORD | rotator-ordinal-position | integer |
| DEIROT.ROTATPOW | rotator-motor-power | logical |
| DEIROT.ROTATRAW | rotator-raw-position | integer |
| DEIROT.ROTATRCL | rotator-remote-control-lockout | logical |
| DEIROT.ROTATREH | rotator-rehome | logical |
| DEIROT.ROTATREL | rotator-relative-move | integer |
| DEIROT.ROTATRMS | rotator-rms-tracking-error | real number |
| DEIROT.ROTATSC | rotator-galil-stopcode | enumerated integer |
| DEIROT.ROTATSEC | rotator-secondary-limit | logical |
| DEIROT.ROTATSJM | rotator-sample-jump | integer |
| DEIROT.ROTATSPD | rotator-galil-speed | integer |
| DEIROT.ROTATST | rotator-galil-stopcode-and-status | ascii string |
| DEIROT.ROTATSTA | rotator-status | enumerated integer |
| DEIROT.ROTATSTQ | rotator-smoothed-torque | real number |
| DEIROT.ROTATSVE | rotator-smoothed-galil-velocity | real number |
| DEIROT.ROTATTAG | rotator-tag | ascii string |
| DEIROT.ROTATTAQ | rotator-time-acquiring | integer |
| DEIROT.ROTATTBL | rotator-interpolation-table | enumerated integer |
| DEIROT.ROTATTER | rotator-raw-position-err | integer |
| DEIROT.ROTATTOR | rotator-torque | real number |
| DEIROT.ROTATTRG | rotator-raw-position-target | integer |
| DEIROT.ROTATTRK | rotator-tracking | logical |
| DEIROT.ROTATTSE | rotator-time-settling | integer |
| DEIROT.ROTATTSH | rotator-time-since-homed | integer |
| DEIROT.ROTATTSL | rotator-time-slewing | integer |
| DEIROT.ROTATTSP | rotator-speed-target | integer |
| DEIROT.ROTATTST | rotator-test | enumerated integer |
| DEIROT.ROTATTTK | rotator-time-tracking | integer |
| DEIROT.ROTATTVA | rotator-value-target | real number |
| DEIROT.ROTATTVE | rotator-velocity-target | real number |
| DEIROT.ROTATVAL | rotator-value | real number |
| DEIROT.ROTATVEL | rotator-galil-velocity | real number |
| DEIROT.ROTATVER | rotator-derived-encoder-velocity | real number |
| DEIROT.ROTATVEV | rotator-derived-velocity | real number |
| DEIROT.SOUNDNAM | rotator-sound-name | ascii string |
| DEIROT.SOUNDVOL | rotator-sound-volume | integer |
| DEIROT.TMPBAYBC | bay-b-enclosure-temperature-celsius | real number |
| DEIROT.TMPBAYBR | bay-b-enclosure-temperature-raw | real number |
| DEIROT.TMPBAYCC | bay-c-enclosure-temperature-celsius | real number |
| DEIROT.TMPBAYCR | bay-c-enclosure-temperature-raw | real number |
| DEIROT.TMPCINC | coolant-in-temperature-celsius | real number |
| DEIROT.TMPCINR | coolant-in-temperature-raw | real number |
| DEIROT.TMPCOUTC | coolant-out-temperature-celsius | real number |
| DEIROT.TMPCOUTR | coolant-out-temperature-raw | real number |
| DEIROT.TMPELECC | roto-controller-temperature-celsius | real number |
| DEIROT.TMPELECR | roto-controller-temperature-raw | real number |
| Keywords from the DEIFCS library |
| DEIFCS.ABFREQ | antiblooming-frequency | integer |
| DEIFCS.ABORTEX | abort-exposure | logical |
| DEIFCS.ADDFRAME | add-frame-numbers | logical |
| DEIFCS.AMPLIST | DEPRECATED-readout-amplifiers | array of integers[4] |
| DEIFCS.AMPMODE | amplifier-readout-mode | enumerated integer |
| DEIFCS.ANTIBLM | antiblooming | logical |
| DEIFCS.AUTOERAS | automatic-erase | logical |
| DEIFCS.AUTOREAD | automatic-readout | logical |
| DEIFCS.AUTOSHUT | automatic-shutter | logical |
| DEIFCS.BINNING | binning | array of integers[2] |
| DEIFCS.CCDBCAST | ccd-music-broadcasts | array of integers[10] |
| DEIFCS.CCDGAIN | ccd-gain | logical |
| DEIFCS.CCDPSIZE | CCD-physical-size | array of integers[4] |
| DEIFCS.CCDSPEED | ccd-readout-speed | enumerated integer |
| DEIFCS.CSHUTTER | FCS-lamp-power/shutter | logical |
| DEIFCS.DATE | exposure-begin | integer |
| DEIFCS.DATE | exposure-end | integer |
| DEIFCS.DETECTOR | detector | ascii string |
| DEIFCS.DETLSIZE | detector-logical-size | array of integers[4] |
| DEIFCS.DEWARID | dewar-id | integer |
| DEIFCS.DFORM | disk-file-format | ascii string |
| DEIFCS.DISKFREE | readout-directory-free-space | real number |
| DEIFCS.DISKFREP | readout-directory-free-percent | real number |
| DEIFCS.DISKIMGS | readout-directory-disk-images | real number |
| DEIFCS.DISKLIST | readout-directory-list | ascii string |
| DEIFCS.ELAPTIME | elapsed-time | integer |
| DEIFCS.ERASECNT | erase-count | integer |
| DEIFCS.ERASEIP | erase-in-progress | logical |
| DEIFCS.ERASLINE | erase-line | logical |
| DEIFCS.EXPOSE | start-exposure | logical |
| DEIFCS.EXPOSIP | exposure-in-progress | logical |
| DEIFCS.FCOMMENT | frame_comments | ascii string |
| DEIFCS.FCSADJXM | FCS-adjusted-Xcorr-mean | real number |
| DEIFCS.FCSADJYM | FCS-adjusted-Xcorr-mean | real number |
| DEIFCS.FCSARCHD | FCS-reference-archive | ascii string |
| DEIFCS.FCSBOXX | FCS-X-correction-threshold | real number |
| DEIFCS.FCSBOXY | FCS-Y-correction-threshold | real number |
| DEIFCS.FCSCCNOX | FCS-Xcorrection-conflicts | integer |
| DEIFCS.FCSCCNOY | FCS-Ycorrection-conflicts | integer |
| DEIFCS.FCSCORX1 | FCS-1-X-correction | real number |
| DEIFCS.FCSCORX2 | FCS-2-X-correction | real number |
| DEIFCS.FCSCORXD | FCS-Xcorr-difference | real number |
| DEIFCS.FCSCORXM | FCS-Xcorr-mean | real number |
| DEIFCS.FCSCORY1 | FCS-1-Y-correction | real number |
| DEIFCS.FCSCORY2 | FCS-2-Y-correction | real number |
| DEIFCS.FCSCORYD | FCS-Ycorr-difference | real number |
| DEIFCS.FCSCORYM | FCS-Ycorr-mean | real number |
| DEIFCS.FCSCUSEL | FCS-active-CuAr-lamp | ascii string |
| DEIFCS.FCSDXLIM | FCS-dewar-Xstage-near-limit | logical |
| DEIFCS.FCSERR | FCS-error-number | integer |
| DEIFCS.FCSETMIS | FCS-ttime-mismatch | logical |
| DEIFCS.FCSEXNOX | FCS-Xexcessive | integer |
| DEIFCS.FCSEXNOY | FCS-Yexcessive | integer |
| DEIFCS.FCSFOMIS | FCS-focus-mismatch | logical |
| DEIFCS.FCSFOTO1 | FCS-focus-tolerance-1 | integer |
| DEIFCS.FCSFOTO2 | FCS-focus-tolerance-2 | integer |
| DEIFCS.FCSGTLIM | FCS-grating-tilt-near-limit | logical |
| DEIFCS.FCSHBEAT | FCS-heartbeat | integer |
| DEIFCS.FCSIMGFI | FCS-image-file | ascii string |
| DEIFCS.FCSINTXM | FCS-integrated-mean-X-error | real number |
| DEIFCS.FCSINTYM | FCS-integrated-mean-Y-error | real number |
| DEIFCS.FCSLAMIS | FCS-lamps-mismatch | logical |
| DEIFCS.FCSLOGFI | FCS-logfile | ascii string |
| DEIFCS.FCSMODE | flexure-compensation-system-mode | enumerated integer |
| DEIFCS.FCSMSG | flexure-compensation-system-message | ascii string |
| DEIFCS.FCSNOFIL | FCS-filter-files | integer |
| DEIFCS.FCSNOFOC | FCS-focus-files | integer |
| DEIFCS.FCSNOGRA | FCS-grating-files | integer |
| DEIFCS.FCSNOSLI | FCS-slider-files | integer |
| DEIFCS.FCSNOWAV | FCS-wavelength-files | integer |
| DEIFCS.FCSREFFI | FCS-reference-file | ascii string |
| DEIFCS.FCSRMSX1 | FCS-det1-Xcorrection-rms | real number |
| DEIFCS.FCSRMSX2 | FCS-det2-Xcorrection-rms | real number |
| DEIFCS.FCSRMSXD | FCS-Xcorrection-diff-rms | real number |
| DEIFCS.FCSRMSXM | FCS-Xcorrection-mean-rms | real number |
| DEIFCS.FCSRMSY1 | FCS-det1-Ycorrection-rms | real number |
| DEIFCS.FCSRMSY2 | FCS-det2-Ycorrection-rms | real number |
| DEIFCS.FCSRMSYD | FCS-Ycorrection-diff-rms | real number |
| DEIFCS.FCSRMSYM | FCS-Ycorrection-mean-rms | real number |
| DEIFCS.FCSSKIPS | FCS-skip-counter | integer |
| DEIFCS.FCSSLBAD | FCS-nomask-lockout | logical |
| DEIFCS.FCSSTA | flexure-compensation-system-status | enumerated integer |
| DEIFCS.FCSSTATE | FCS-state | enumerated integer |
| DEIFCS.FCSTASK | flexure-compensation-system-activity | enumerated integer |
| DEIFCS.FCSTMLIM | FCS-tent-mirror-near-limit | logical |
| DEIFCS.FCSTRACK | FCS-tracking-status | enumerated integer |
| DEIFCS.FLUSHMOD | flush-mode | enumerated integer |
| DEIFCS.FRAMENO | frame-number | integer |
| DEIFCS.ICOMMENT | instrument_comments | ascii string |
| DEIFCS.IMSHMID | image-shared-mem-id | integer |
| DEIFCS.IMSHMNI | image-shared-mem-num-ixhdu | integer |
| DEIFCS.IMSHMSZ | image-shared-mem-size | integer |
| DEIFCS.INFOMCFG | infoman_config_file_s | ascii string |
| DEIFCS.INFOMCLK | infoman_clock | integer |
| DEIFCS.INFOMDMP | infoman_dump_data | integer |
| DEIFCS.INFOMHOM | infoman_host | ascii string |
| DEIFCS.INFOMLOG | infoman_log | ascii string |
| DEIFCS.INFOMMSG | infoman_message | ascii string |
| DEIFCS.INFOMPID | infoman_pid | integer |
| DEIFCS.INFOMSRV | infoman_server_s | ascii string |
| DEIFCS.INFOMTRF | infoman_traffic_id | ascii string |
| DEIFCS.INSTRUME | instrument | ascii string |
| DEIFCS.KEEPPREP | keep-prescan-pixels | logical |
| DEIFCS.LASTROWS | last-amp-rows-received | array of integers[2] |
| DEIFCS.LFRAMENO | last-frame-number | integer |
| DEIFCS.LTODISK | last-to-disk | logical |
| DEIFCS.MOSMODE | mosiac-readout-mode | enumerated integer |
| DEIFCS.MPPMODE | mpp-readout-mode | logical |
| DEIFCS.NSUBINT | number-of-subintegrations | integer |
| DEIFCS.NUMAMPS | DEPRECATED-number-of-amplifiers | integer |
| DEIFCS.OBJECT | object | ascii string |
| DEIFCS.OBSERVER | observer | ascii string |
| DEIFCS.OBSTYPE | obstype | ascii string |
| DEIFCS.OUTDIR | readout-directory | ascii string |
| DEIFCS.OUTFILE | readout-filename | ascii string |
| DEIFCS.OVRFLUSH | postscan-flush-lines | integer |
| DEIFCS.PANE | pane | array of integers[4] |
| DEIFCS.PANE1 | pane-1 | array of integers[4] |
| DEIFCS.PANE2 | pane-2 | array of integers[4] |
| DEIFCS.PANE3 | pane-3 | array of integers[4] |
| DEIFCS.PANE4 | pane-4 | array of integers[4] |
| DEIFCS.PANEFITS | pane-fits-hdu-format | enumerated integer |
| DEIFCS.PANELIST | readout-pane-list | integer bit-mask |
| DEIFCS.PANERROR | pane-error-list | integer bit-mask |
| DEIFCS.PAUSE | pause-exposure | logical |
| DEIFCS.PAUSEIP | pause-in-progress | logical |
| DEIFCS.POSTLINE | postscan-lines | integer |
| DEIFCS.POSTPIX | postscan-pixels | integer |
| DEIFCS.PRECOL | prescan-columns | integer |
| DEIFCS.PREFLUSH | prescan-flush-lines | integer |
| DEIFCS.PRELINE | prescan-lines | integer |
| DEIFCS.PREPIX | prescan-pixels | integer |
| DEIFCS.PREROW | prescan-rows | integer |
| DEIFCS.RCOMMENT | run_comments | ascii string |
| DEIFCS.RESUME | resume-exposure | logical |
| DEIFCS.ROWSHFT | row-shift-per-subintegrations | integer |
| DEIFCS.SHUTTER | FCS-LAMP-shutter | logical |
| DEIFCS.STOPEX | stop-exposure | logical |
| DEIFCS.SYNOPFMT | format_for_SYNOPSIS | ascii string |
| DEIFCS.SYNOPSIS | synopsis_of_FITS_keywords | ascii string |
| DEIFCS.TODISK | to-disk | logical |
| DEIFCS.TTIME | total-time | integer |
| DEIFCS.UTB15VEN | ccd-15-volts-enable | logical |
| DEIFCS.UTB30VEN | ccd-30-volts-enable | logical |
| DEIFCS.UTBFANS | ccd-controller-fans | logical |
| DEIFCS.UTBM15V | ccd-minus-15-volts | real number |
| DEIFCS.UTBM15VM | ccd-minus-15-volts-map | array of real numbers[5] |
| DEIFCS.UTBM15VR | ccd-minus-15-volts-raw | integer |
| DEIFCS.UTBN2FIL | ccd-liquid-n2-pressure-valve | logical |
| DEIFCS.UTBN2HTR | ccd-liquid-n2-reservoir-heater | logical |
| DEIFCS.UTBP15V | ccd-plus-15-volts | real number |
| DEIFCS.UTBP15VM | ccd-plus-15-volts-map | array of real numbers[5] |
| DEIFCS.UTBP15VR | ccd-plus-15-volts-raw | integer |
| DEIFCS.UTBP30V | ccd-plus-30-volts | real number |
| DEIFCS.UTBP30VM | ccd-plus-30-volts-map | array of real numbers[5] |
| DEIFCS.UTBP30VR | ccd-plus-30-volts-raw | integer |
| DEIFCS.UTBP5V | ccd-plus-5-volts | real number |
| DEIFCS.UTBP5VM | ccd-plus-5-volts-map | array of real numbers[5] |
| DEIFCS.UTBP5VR | ccd-plus-5-volts-raw | integer |
| DEIFCS.UTBTEMP | ccd-utility-board-temperature | real number |
| DEIFCS.UTBTEMPM | ccd-utility-board-temperature-map | array of real numbers[5] |
| DEIFCS.UTBTEMPR | ccd-utility-board-temperature-raw | integer |
| DEIFCS.UTBTMPS | ccd-desired-utility-board-temperature | real number |
| DEIFCS.UTBTMPSM | ccd-desired-utility-board-temperature-map | array of real numbers[5] |
| DEIFCS.UTBTMPSR | ccd-desired-utility-board-temperature-raw | integer |
| DEIFCS.VIDOFF1 | vidoff-1 | integer |
| DEIFCS.VIDOFF2 | vidoff-2 | integer |
| DEIFCS.VIDOFF3 | vidoff-3 | integer |
| DEIFCS.VIDOFF4 | vidoff-4 | integer |
| DEIFCS.VOFFSET0 | video-offset-amplifier-0 | integer |
| DEIFCS.VOFFSET1 | video-offset-amplifier-1 | integer |
| DEIFCS.VOFFSET2 | video-offset-amplifier-2 | integer |
| DEIFCS.VOFFSET3 | video-offset-amplifier-3 | integer |
| DEIFCS.WCRATE | writing-crate-memory | logical |
| DEIFCS.WDISK | writing-disk | logical |
| DEIFCS.WINDOW | window | array of integers[5] |