If you need to manually power cycle the crates, the crates for both the science and FCS detectors are located in the K2 computer room (see figure 1 below)
|
|
start_crate s
deimos_dewar_temperature_exit = 1 broadcast_monitor_exit = 1After executing those commands, issue the i command again and verify that the jobs were properly terminated.
< restartto invoke the restart script and verify that it completes without error.
< broadcastand verify that it completes without error.
< dewartempand verify that it completes without error.
< upsand verify that it completes without error.
^]
quit
First, determine what tasks are running: -> i NAME ENTRY TID PRI STATUS PC SP ERRNO DELAY ---------- ------------ -------- --- ---------- -------- -------- ------- ----- tExcTask excTask 3dfe1b8 0 PEND 185940 3dfe0e0 0 0 tLogTask logTask 3dfb840 0 PEND 185940 3dfb778 0 0 tShell shell 3de4788 1 READY 157924 3de4408 30065 0 tRlogind rlogind 3df3770 2 PEND 153f60 3df33b0 0 0 tTelnetd telnetd 3df1848 2 PEND 153f60 3df16e8 0 0 tRlogOutTasrlogOutTask 3ffee28 2 READY 153f60 3ffeca0 0 0 tRlogInTaskrlogInTask 3ddea30 2 READY 153e4c 3dde898 0 0 tWdbTask 14c1c4 3de6f38 3 PEND 153f60 3de6da0 0 0 tNetTask netTask 3df6c38 50 READY 15531c 3df6b70 0 0 tTftpdTask tftpdTask 3deebf0 55 PEND 153f60 3dee428 0 0 ccdClock ccdClock 3c33ed0 90 DELAY 156ed8 3c33e10 0 1 tPortmapd portmapd 3df02b8 100 PEND 153f60 3df0148 16 0 MLOG_STDOUTstart_mlog_s 3c69550 100 PEND 185940 3c69250 0 0 cserv cserv 3c50ca8 100 PEND 153f60 3c50a90 0 0 responder responder 3b3c518 100 PEND 185940 3b3b400 0 0 broad_mon broadcast_mo 3b20800 110 DELAY 156ed8 3b20740 0 35 rccd rccd 3c2a088 150 PEND+T 153f60 3c29ee8 3d0004 14 dewar_temp deimos_dewar 3b1be20 160 DELAY 156ed8 3b1bc78 3d0001 4 value = 0 = 0x0 Next, halt the broad_mon and dewar_temp processes: -> deimos_dewar_temperature_exit = 1 deimos_dewar_temperature_exit = 0x3d1f608: value = 1 = 0x1 -> broadcast_monitor_exit = 1 broadcast_monitor_exit = 0x3b480e8: value = 1 = 0x1 Verify that those processes are gone: -> i NAME ENTRY TID PRI STATUS PC SP ERRNO DELAY ---------- ------------ -------- --- ---------- -------- -------- ------- ----- tExcTask excTask 3dfe1b8 0 PEND 185940 3dfe0e0 0 0 tLogTask logTask 3dfb840 0 PEND 185940 3dfb778 0 0 tShell shell 3de4788 1 READY 157924 3de4408 30065 0 tRlogind rlogind 3df3770 2 PEND 153f60 3df33b0 0 0 tTelnetd telnetd 3df1848 2 PEND 153f60 3df16e8 0 0 tRlogOutTasrlogOutTask 3ffee28 2 READY 153f60 3ffeca0 0 0 tRlogInTaskrlogInTask 3ddea30 2 READY 153e4c 3dde898 0 0 tWdbTask 14c1c4 3de6f38 3 PEND 153f60 3de6da0 0 0 tNetTask netTask 3df6c38 50 READY 15531c 3df6b70 0 0 tTftpdTask tftpdTask 3deebf0 55 PEND 153f60 3dee428 0 0 ccdClock ccdClock 3c33ed0 90 READY 156ed8 3c33e10 0 0 tPortmapd portmapd 3df02b8 100 PEND 153f60 3df0148 16 0 MLOG_STDOUTstart_mlog_s 3c69550 100 PEND 185940 3c69250 0 0 cserv cserv 3c50ca8 100 PEND 153f60 3c50a90 0 0 responder responder 3b3c518 100 PEND 185940 3b3b400 0 0 rccd rccd 3c2a088 150 PEND+T 153f60 3c29ee8 3d0004 39 value = 0 = 0x0 Launch the restart script: -> < restart startup("/vx/deivme/dsp",0) Sending STP command to TIMING board Sending LOR command to TIMING board UTB application 0 test location= 10 UTB digital output= bf80 Analog switches in dewar electronics commanded open Analog switches in dewar electronics indicate open Sending hardware reset to TIMING board msg size = 2 words. reply size = 2 words msg = 0X102 0X54544852 reply = 0X10002 0X444f4e Sending STP command to TIMING board Will verify vmeinf eprom against /vx/deivme/dsp/vmeinf/vme.s VMEINF board verification status= 0, should be 0 Will verify timing eprom against /vx/deivme/dsp/timing/timing.s TIMING board verification status= 0, should be 0 Will verify utility eprom against /vx/deivme/dsp/utility/util.s Expecting 1 verification error: at 800081 verify error: at address 800081 expected: 000004 got: 052d79 EOF UTILITY board verification status= 1, should be 1 EEPROMs verified correctly. Proceeding with power-up +5v readback raw ADC reading = 3424 volts= 5.031704 prior to enables +15v readback raw ADC reading = 3490 voltage = 16.015638 prior to enable -15v readback raw ADC reading = 622 voltage = -16.035444 prior to enable +30v readback raw ADC reading = 2049 volts = 0.028058 prior to enable UTB digital output= bf80 +/-15v power enabled +5v readback raw ADC reading = 3425 volts= 5.035361 after 15v enable +15v readback raw ADC reading = 3494 voltage = 16.060064 after 15v enable -15v readback raw ADC reading = 619 voltage = -16.069180 after 15v enable +30v readback raw ADC reading = 2049 volts = 0.028058 after 15v enable UTB digital output= be80 +30v power enabled +5v readback raw ADC reading = 3425 volts= 5.035361 prior after enables +15v readback raw ADC reading = 3495 voltage = 16.071171 after enables -15v readback raw ADC reading = 619 voltage = -16.069180 after enables +30v readback raw ADC reading = 3283 volts = 34.651104 after enables Analog switches in dewar electronics commanded open Analog switches in dewar electronics indicate open Bias and clock voltages have been set, but not yet sent to CCD Bias voltages for CCD 1 CCD 1 bias 0 ADC 3362 ( d22) MUX 1.919 Volts 19.191 Vdd-1 CCD 1 bias 1 ADC 3361 ( d21) MUX 1.918 Volts 19.176 Vdd-2 CCD 1 bias 2 ADC 2912 ( b60) MUX 1.260 Volts 12.603 RD-A CCD 1 bias 3 ADC 2912 ( b60) MUX 1.260 Volts 12.603 RD-B CCD 1 bias 4 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-A CCD 1 bias 5 ADC 3387 ( d3b) MUX 1.956 Volts 3.912 Spare-2 CCD 1 bias 6 ADC 2725 ( aa5) MUX 0.988 Volts 9.880 Guard ring CCD 1 bias 7 ADC 2050 ( 802) MUX 0.001 Volts 0.001 Substrate CCD 1 bias 8 ADC 3387 ( d3b) MUX 1.956 Volts 3.912 Spare-1 CCD 1 bias 9 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-B CCD 1 bias 10 ADC 3390 ( d3e) MUX 1.961 Volts 3.921 Spare-3 CCD 1 bias 11 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Bi-polar Spare CCD 1 bias 12 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Ground CCD 1 bias 13 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Ground CCD 1 bias 14 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Ground CCD 1 bias 15 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Ground Bias voltages for CCD 2 CCD 2 bias 0 ADC 3398 ( d46) MUX 1.972 Volts 19.717 Vdd-1 CCD 2 bias 1 ADC 3331 ( d03) MUX 1.874 Volts 18.738 Vdd-2 CCD 2 bias 2 ADC 2912 ( b60) MUX 1.260 Volts 12.603 RD-A CCD 2 bias 3 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-B CCD 2 bias 4 ADC 2050 ( 802) MUX 0.000 Volts 0.001 OG-A CCD 2 bias 5 ADC 3388 ( d3c) MUX 1.958 Volts 3.915 Spare-2 CCD 2 bias 6 ADC 2726 ( aa6) MUX 0.989 Volts 9.894 Guard ring CCD 2 bias 7 ADC 2052 ( 804) MUX 0.004 Volts 0.004 Substrate CCD 2 bias 8 ADC 3390 ( d3e) MUX 1.961 Volts 3.921 Spare-1 CCD 2 bias 9 ADC 2050 ( 802) MUX 0.000 Volts 0.001 OG-B CCD 2 bias 10 ADC 3389 ( d3d) MUX 1.959 Volts 3.918 Spare-3 CCD 2 bias 11 ADC 2050 ( 802) MUX 0.001 Volts 0.015 Bi-polar Spare CCD 2 bias 12 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 2 bias 13 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Ground CCD 2 bias 14 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 2 bias 15 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Ground Bias voltages for CCD 3 CCD 3 bias 0 ADC 3324 ( cfc) MUX 1.864 Volts 18.635 Vdd-1 CCD 3 bias 1 ADC 3323 ( cfb) MUX 1.862 Volts 18.621 Vdd-2 CCD 3 bias 2 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-A CCD 3 bias 3 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-B CCD 3 bias 4 ADC 2050 ( 802) MUX 0.000 Volts 0.001 OG-A CCD 3 bias 5 ADC 3393 ( d41) MUX 1.965 Volts 3.930 Spare-2 CCD 3 bias 6 ADC 2726 ( aa6) MUX 0.989 Volts 9.894 Guard ring CCD 3 bias 7 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Substrate CCD 3 bias 8 ADC 3391 ( d3f) MUX 1.962 Volts 3.924 Spare-1 CCD 3 bias 9 ADC 2050 ( 802) MUX 0.000 Volts 0.001 OG-B CCD 3 bias 10 ADC 3392 ( d40) MUX 1.963 Volts 3.927 Spare-3 CCD 3 bias 11 ADC 2050 ( 802) MUX 0.001 Volts 0.015 Bi-polar Spare CCD 3 bias 12 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 3 bias 13 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 3 bias 14 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 3 bias 15 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground Bias voltages for CCD 4 CCD 4 bias 0 ADC 3362 ( d22) MUX 1.919 Volts 19.191 Vdd-1 CCD 4 bias 1 ADC 3362 ( d22) MUX 1.919 Volts 19.191 Vdd-2 CCD 4 bias 2 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-A CCD 4 bias 3 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-B CCD 4 bias 4 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-A CCD 4 bias 5 ADC 3391 ( d3f) MUX 1.962 Volts 3.924 Spare-2 CCD 4 bias 6 ADC 2726 ( aa6) MUX 0.989 Volts 9.894 Guard ring CCD 4 bias 7 ADC 2047 ( 7ff) MUX -0.003 Volts -0.003 Substrate CCD 4 bias 8 ADC 3394 ( d42) MUX 1.966 Volts 3.933 Spare-1 CCD 4 bias 9 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-B CCD 4 bias 10 ADC 3391 ( d3f) MUX 1.962 Volts 3.924 Spare-3 CCD 4 bias 11 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Bi-polar Spare CCD 4 bias 12 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 4 bias 13 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 4 bias 14 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 4 bias 15 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground Bias voltages for CCD 5 CCD 5 bias 0 ADC 3430 ( d66) MUX 2.019 Volts 20.185 Vdd-1 CCD 5 bias 1 ADC 3395 ( d43) MUX 1.967 Volts 19.673 Vdd-2 CCD 5 bias 2 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-A CCD 5 bias 3 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-B CCD 5 bias 4 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-A CCD 5 bias 5 ADC 3388 ( d3c) MUX 1.958 Volts 3.915 Spare-2 CCD 5 bias 6 ADC 2726 ( aa6) MUX 0.989 Volts 9.894 Guard ring CCD 5 bias 7 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Substrate CCD 5 bias 8 ADC 3394 ( d42) MUX 1.966 Volts 3.933 Spare-1 CCD 5 bias 9 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-B CCD 5 bias 10 ADC 3391 ( d3f) MUX 1.962 Volts 3.924 Spare-3 CCD 5 bias 11 ADC 2050 ( 802) MUX 0.001 Volts 0.015 Bi-polar Spare CCD 5 bias 12 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 5 bias 13 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 5 bias 14 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 5 bias 15 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground Bias voltages for CCD 6 CCD 6 bias 0 ADC 3396 ( d44) MUX 1.969 Volts 19.688 Vdd-1 CCD 6 bias 1 ADC 3326 ( cfe) MUX 1.866 Volts 18.665 Vdd-2 CCD 6 bias 2 ADC 2912 ( b60) MUX 1.260 Volts 12.603 RD-A CCD 6 bias 3 ADC 2912 ( b60) MUX 1.260 Volts 12.603 RD-B CCD 6 bias 4 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-A CCD 6 bias 5 ADC 3389 ( d3d) MUX 1.959 Volts 3.918 Spare-2 CCD 6 bias 6 ADC 2726 ( aa6) MUX 0.989 Volts 9.894 Guard ring CCD 6 bias 7 ADC 2048 ( 800) MUX -0.001 Volts -0.001 Substrate CCD 6 bias 8 ADC 3389 ( d3d) MUX 1.959 Volts 3.918 Spare-1 CCD 6 bias 9 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-B CCD 6 bias 10 ADC 3389 ( d3d) MUX 1.959 Volts 3.918 Spare-3 CCD 6 bias 11 ADC 2050 ( 802) MUX 0.001 Volts 0.015 Bi-polar Spare CCD 6 bias 12 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 6 bias 13 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 6 bias 14 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 6 bias 15 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground Bias voltages for CCD 7 CCD 7 bias 0 ADC 3326 ( cfe) MUX 1.866 Volts 18.665 Vdd-1 CCD 7 bias 1 ADC 3393 ( d41) MUX 1.964 Volts 19.644 Vdd-2 CCD 7 bias 2 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-A CCD 7 bias 3 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-B CCD 7 bias 4 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-A CCD 7 bias 5 ADC 3389 ( d3d) MUX 1.959 Volts 3.918 Spare-2 CCD 7 bias 6 ADC 2726 ( aa6) MUX 0.989 Volts 9.894 Guard ring CCD 7 bias 7 ADC 2047 ( 7ff) MUX -0.003 Volts -0.003 Substrate CCD 7 bias 8 ADC 3392 ( d40) MUX 1.963 Volts 3.927 Spare-1 CCD 7 bias 9 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-B CCD 7 bias 10 ADC 3390 ( d3e) MUX 1.961 Volts 3.921 Spare-3 CCD 7 bias 11 ADC 3388 ( d3c) MUX 1.958 Volts 19.576 Bi-polar Spare CCD 7 bias 12 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 7 bias 13 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 7 bias 14 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 7 bias 15 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground Bias voltages for CCD 8 CCD 8 bias 0 ADC 3325 ( cfd) MUX 1.865 Volts 18.650 Vdd-1 CCD 8 bias 1 ADC 3381 ( d35) MUX 1.947 Volts 19.469 Vdd-2 CCD 8 bias 2 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-A CCD 8 bias 3 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-B CCD 8 bias 4 ADC 2051 ( 803) MUX 0.002 Volts 0.004 OG-A CCD 8 bias 5 ADC 3392 ( d40) MUX 1.963 Volts 3.927 Spare-2 CCD 8 bias 6 ADC 2726 ( aa6) MUX 0.989 Volts 9.894 Guard ring CCD 8 bias 7 ADC 2058 ( 80a) MUX 0.013 Volts 0.013 Substrate CCD 8 bias 8 ADC 3389 ( d3d) MUX 1.959 Volts 3.918 Spare-1 CCD 8 bias 9 ADC 2051 ( 803) MUX 0.002 Volts 0.004 OG-B CCD 8 bias 10 ADC 3391 ( d3f) MUX 1.962 Volts 3.924 Spare-3 CCD 8 bias 11 ADC 2050 ( 802) MUX 0.001 Volts 0.015 Bi-polar Spare CCD 8 bias 12 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 8 bias 13 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 8 bias 14 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 8 bias 15 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground Open bias voltages are all within tolerance Low-rail clock voltages for clock gen 1 CLKGEN 1 clock 0 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 1 clock 1 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 1 clock 2 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 1 clock 3 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 1 clock 4 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 1 clock 5 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 1 clock 6 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 1 clock 7 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 1 clock 8 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 1 clock 9 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 1 clock 10 ADC 2048 ( 800) MUX 0.000 Volts 0.000 CLKGEN 1 clock 11 ADC 2049 ( 801) MUX 0.001 Volts 0.015 CLKGEN 1 clock 12 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 1 clock 13 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 1 clock 14 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 1 clock 15 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978 CLKGEN 1 clock 16 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 1 clock 17 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 1 clock 18 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 1 clock 19 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 1 clock 20 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 1 clock 21 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 1 clock 22 ADC 2048 ( 800) MUX 0.000 Volts 0.000 CLKGEN 1 clock 23 ADC 2049 ( 801) MUX 0.001 Volts 0.015 High-rail clock voltages for clock gen 1 CLKGEN 1 clock 0 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 1 clock 1 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 1 clock 2 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 1 clock 3 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 1 clock 4 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 1 clock 5 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 1 clock 6 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 1 clock 7 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 1 clock 8 ADC 2459 ( 99b) MUX 0.602 Volts 6.018 CLKGEN 1 clock 9 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 1 clock 10 ADC 2593 ( a21) MUX 0.798 Volts 7.980 CLKGEN 1 clock 11 ADC 2595 ( a23) MUX 0.801 Volts 8.009 CLKGEN 1 clock 12 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 1 clock 13 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 1 clock 14 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 1 clock 15 ADC 2391 ( 957) MUX 0.502 Volts 5.022 CLKGEN 1 clock 16 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 1 clock 17 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 1 clock 18 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 1 clock 19 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 1 clock 20 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 1 clock 21 ADC 2391 ( 957) MUX 0.502 Volts 5.022 CLKGEN 1 clock 22 ADC 2594 ( a22) MUX 0.799 Volts 7.994 CLKGEN 1 clock 23 ADC 2594 ( a22) MUX 0.799 Volts 7.994 Low-rail clock voltages for clock gen 2 CLKGEN 2 clock 0 ADC 1642 ( 66a) MUX -0.594 Volts -5.944 CLKGEN 2 clock 1 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 2 clock 2 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 2 clock 3 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978 CLKGEN 2 clock 4 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 2 clock 5 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 2 clock 6 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 2 clock 7 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 2 clock 8 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 2 clock 9 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978 CLKGEN 2 clock 10 ADC 2048 ( 800) MUX 0.000 Volts 0.000 CLKGEN 2 clock 11 ADC 2049 ( 801) MUX 0.001 Volts 0.015 CLKGEN 2 clock 12 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 2 clock 13 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 2 clock 14 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 2 clock 15 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978 CLKGEN 2 clock 16 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 2 clock 17 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 2 clock 18 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 2 clock 19 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 2 clock 20 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 2 clock 21 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 2 clock 22 ADC 2048 ( 800) MUX 0.000 Volts 0.000 CLKGEN 2 clock 23 ADC 2049 ( 801) MUX 0.001 Volts 0.015 High-rail clock voltages for clock gen 2 CLKGEN 2 clock 0 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 2 clock 1 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 2 clock 2 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 2 clock 3 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 2 clock 4 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 5 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 6 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 7 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 8 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 9 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 2 clock 10 ADC 2593 ( a21) MUX 0.798 Volts 7.980 CLKGEN 2 clock 11 ADC 2594 ( a22) MUX 0.799 Volts 7.994 CLKGEN 2 clock 12 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 2 clock 13 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 2 clock 14 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 2 clock 15 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 2 clock 16 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 17 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 18 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 19 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 20 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 21 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 2 clock 22 ADC 2593 ( a21) MUX 0.798 Volts 7.980 CLKGEN 2 clock 23 ADC 2595 ( a23) MUX 0.801 Volts 8.009 Low-rail clock voltages for clock gen 3 CLKGEN 3 clock 0 ADC 1642 ( 66a) MUX -0.594 Volts -5.944 CLKGEN 3 clock 1 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 3 clock 2 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 3 clock 3 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 3 clock 4 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 3 clock 5 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 3 clock 6 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 3 clock 7 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 3 clock 8 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 3 clock 9 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 3 clock 10 ADC 2048 ( 800) MUX 0.000 Volts 0.000 CLKGEN 3 clock 11 ADC 2049 ( 801) MUX 0.001 Volts 0.015 CLKGEN 3 clock 12 ADC 1642 ( 66a) MUX -0.594 Volts -5.944 CLKGEN 3 clock 13 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 3 clock 14 ADC 1642 ( 66a) MUX -0.594 Volts -5.944 CLKGEN 3 clock 15 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 3 clock 16 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 3 clock 17 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 3 clock 18 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 3 clock 19 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 3 clock 20 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 3 clock 21 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 3 clock 22 ADC 2048 ( 800) MUX 0.000 Volts 0.000 CLKGEN 3 clock 23 ADC 2049 ( 801) MUX 0.001 Volts 0.015 High-rail clock voltages for clock gen 3 CLKGEN 3 clock 0 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 3 clock 1 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 3 clock 2 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 3 clock 3 ADC 2389 ( 955) MUX 0.499 Volts 4.993 CLKGEN 3 clock 4 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 5 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 6 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 7 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 8 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 9 ADC 2389 ( 955) MUX 0.499 Volts 4.993 CLKGEN 3 clock 10 ADC 2592 ( a20) MUX 0.796 Volts 7.965 CLKGEN 3 clock 11 ADC 2593 ( a21) MUX 0.798 Volts 7.980 CLKGEN 3 clock 12 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 3 clock 13 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 3 clock 14 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 3 clock 15 ADC 2389 ( 955) MUX 0.499 Volts 4.993 CLKGEN 3 clock 16 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 17 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 18 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 19 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 20 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 21 ADC 2389 ( 955) MUX 0.499 Volts 4.993 CLKGEN 3 clock 22 ADC 2592 ( a20) MUX 0.796 Volts 7.965 CLKGEN 3 clock 23 ADC 2593 ( a21) MUX 0.798 Volts 7.980 Low-rail clock voltages for clock gen 4 CLKGEN 4 clock 0 ADC 1642 ( 66a) MUX -0.594 Volts -5.944 CLKGEN 4 clock 1 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 4 clock 2 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 4 clock 3 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 4 clock 4 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 4 clock 5 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 4 clock 6 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 4 clock 7 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 4 clock 8 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 4 clock 9 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 4 clock 10 ADC 2048 ( 800) MUX 0.000 Volts 0.000 CLKGEN 4 clock 11 ADC 2049 ( 801) MUX 0.001 Volts 0.015 CLKGEN 4 clock 12 ADC 1642 ( 66a) MUX -0.594 Volts -5.944 CLKGEN 4 clock 13 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 4 clock 14 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 4 clock 15 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978 CLKGEN 4 clock 16 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 4 clock 17 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 4 clock 18 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 4 clock 19 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 4 clock 20 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 4 clock 21 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978 CLKGEN 4 clock 22 ADC 2048 ( 800) MUX 0.000 Volts 0.000 CLKGEN 4 clock 23 ADC 2049 ( 801) MUX 0.001 Volts 0.015 High-rail clock voltages for clock gen 4 CLKGEN 4 clock 0 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 4 clock 1 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 4 clock 2 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 4 clock 3 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 4 clock 4 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 4 clock 5 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 4 clock 6 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 4 clock 7 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 4 clock 8 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 4 clock 9 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 4 clock 10 ADC 2593 ( a21) MUX 0.798 Volts 7.980 CLKGEN 4 clock 11 ADC 2594 ( a22) MUX 0.799 Volts 7.994 CLKGEN 4 clock 12 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 4 clock 13 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 4 clock 14 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 4 clock 15 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 4 clock 16 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 4 clock 17 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 4 clock 18 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 4 clock 19 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 4 clock 20 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 4 clock 21 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 4 clock 22 ADC 2593 ( a21) MUX 0.798 Volts 7.980 Readccd task is still alive CLKGEN 4 clock 23 ADC 2594 ( a22) MUX 0.799 Volts 7.994 Open clock voltages are all within tolerance Switch states set to select clock low rails VDD and RD bias voltages have all been set to minimum voltage Analog switches commanded closed. Analog switches in dewar electronics indicate closed +5v readback raw ADC reading = 3425 volts= 5.035361 after closure +15v readback raw ADC reading = 3494 voltage = 16.060064 after closure -15v readback raw ADC reading = 618 voltage = -16.080425 after closure +30v readback raw ADC reading = 3283 volts = 34.651104 after closure About to pulse all RG clocks with a +2 volt pulse About to drop all RG clocks back to 0 volts About to command VDD and RD back to nominal values VDD, RD, and RG have been commanded to nominal voltage CCD is now powered up. Bias voltages for CCD 1 CCD 1 bias 0 ADC 3351 ( d17) MUX 1.903 Volts 19.030 Vdd-1 CCD 1 bias 1 ADC 3351 ( d17) MUX 1.903 Volts 19.030 Vdd-2 CCD 1 bias 2 ADC 2912 ( b60) MUX 1.260 Volts 12.603 RD-A CCD 1 bias 3 ADC 2912 ( b60) MUX 1.260 Volts 12.603 RD-B CCD 1 bias 4 ADC 2050 ( 802) MUX 0.000 Volts 0.001 OG-A CCD 1 bias 5 ADC 3387 ( d3b) MUX 1.956 Volts 3.912 Spare-2 CCD 1 bias 6 ADC 2725 ( aa5) MUX 0.988 Volts 9.880 Guard ring CCD 1 bias 7 ADC 2050 ( 802) MUX 0.001 Volts 0.001 Substrate CCD 1 bias 8 ADC 3387 ( d3b) MUX 1.956 Volts 3.912 Spare-1 CCD 1 bias 9 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-B CCD 1 bias 10 ADC 3390 ( d3e) MUX 1.961 Volts 3.921 Spare-3 CCD 1 bias 11 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Bi-polar Spare CCD 1 bias 12 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Ground CCD 1 bias 13 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Ground CCD 1 bias 14 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Ground CCD 1 bias 15 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Ground Bias voltages for CCD 2 CCD 2 bias 0 ADC 3387 ( d3b) MUX 1.956 Volts 19.556 Vdd-1 CCD 2 bias 1 ADC 3321 ( cf9) MUX 1.859 Volts 18.592 Vdd-2 CCD 2 bias 2 ADC 2912 ( b60) MUX 1.260 Volts 12.603 RD-A CCD 2 bias 3 ADC 2912 ( b60) MUX 1.260 Volts 12.603 RD-B CCD 2 bias 4 ADC 2050 ( 802) MUX 0.000 Volts 0.001 OG-A CCD 2 bias 5 ADC 3388 ( d3c) MUX 1.958 Volts 3.915 Spare-2 CCD 2 bias 6 ADC 2726 ( aa6) MUX 0.989 Volts 9.894 Guard ring CCD 2 bias 7 ADC 2052 ( 804) MUX 0.004 Volts 0.004 Substrate CCD 2 bias 8 ADC 3390 ( d3e) MUX 1.961 Volts 3.921 Spare-1 CCD 2 bias 9 ADC 2050 ( 802) MUX 0.000 Volts 0.001 OG-B CCD 2 bias 10 ADC 3389 ( d3d) MUX 1.959 Volts 3.918 Spare-3 CCD 2 bias 11 ADC 2050 ( 802) MUX 0.001 Volts 0.015 Bi-polar Spare CCD 2 bias 12 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 2 bias 13 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 2 bias 14 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Ground CCD 2 bias 15 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Ground Bias voltages for CCD 3 CCD 3 bias 0 ADC 3314 ( cf2) MUX 1.849 Volts 18.489 Vdd-1 CCD 3 bias 1 ADC 3313 ( cf1) MUX 1.847 Volts 18.475 Vdd-2 CCD 3 bias 2 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-A CCD 3 bias 3 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-B CCD 3 bias 4 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-A CCD 3 bias 5 ADC 3393 ( d41) MUX 1.965 Volts 3.930 Spare-2 CCD 3 bias 6 ADC 2726 ( aa6) MUX 0.989 Volts 9.894 Guard ring CCD 3 bias 7 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Substrate CCD 3 bias 8 ADC 3390 ( d3e) MUX 1.961 Volts 3.921 Spare-1 CCD 3 bias 9 ADC 2050 ( 802) MUX 0.000 Volts 0.001 OG-B CCD 3 bias 10 ADC 3392 ( d40) MUX 1.963 Volts 3.927 Spare-3 CCD 3 bias 11 ADC 2050 ( 802) MUX 0.001 Volts 0.015 Bi-polar Spare CCD 3 bias 12 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 3 bias 13 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Ground CCD 3 bias 14 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 3 bias 15 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground Bias voltages for CCD 4 CCD 4 bias 0 ADC 3351 ( d17) MUX 1.903 Volts 19.030 Vdd-1 CCD 4 bias 1 ADC 3352 ( d18) MUX 1.904 Volts 19.045 Vdd-2 CCD 4 bias 2 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-A CCD 4 bias 3 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-B CCD 4 bias 4 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-A CCD 4 bias 5 ADC 3391 ( d3f) MUX 1.962 Volts 3.924 Spare-2 CCD 4 bias 6 ADC 2726 ( aa6) MUX 0.989 Volts 9.894 Guard ring CCD 4 bias 7 ADC 2047 ( 7ff) MUX -0.003 Volts -0.003 Substrate CCD 4 bias 8 ADC 3394 ( d42) MUX 1.966 Volts 3.933 Spare-1 CCD 4 bias 9 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-B CCD 4 bias 10 ADC 3391 ( d3f) MUX 1.962 Volts 3.924 Spare-3 CCD 4 bias 11 ADC 2050 ( 802) MUX 0.001 Volts 0.015 Bi-polar Spare CCD 4 bias 12 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 4 bias 13 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 4 bias 14 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 4 bias 15 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground Bias voltages for CCD 5 CCD 5 bias 0 ADC 3426 ( d62) MUX 2.013 Volts 20.127 Vdd-1 Invalid voltage 20.127 for Vdd-1 on CCD 5; should be 19.995 CCD 5 bias 1 ADC 3385 ( d39) MUX 1.953 Volts 19.527 Vdd-2 CCD 5 bias 2 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-A CCD 5 bias 3 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-B CCD 5 bias 4 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-A CCD 5 bias 5 ADC 3388 ( d3c) MUX 1.958 Volts 3.915 Spare-2 CCD 5 bias 6 ADC 2726 ( aa6) MUX 0.989 Volts 9.894 Guard ring CCD 5 bias 7 ADC 2049 ( 801) MUX 0.000 Volts 0.000 Substrate CCD 5 bias 8 ADC 3394 ( d42) MUX 1.966 Volts 3.933 Spare-1 CCD 5 bias 9 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-B CCD 5 bias 10 ADC 3391 ( d3f) MUX 1.962 Volts 3.924 Spare-3 CCD 5 bias 11 ADC 2050 ( 802) MUX 0.001 Volts 0.015 Bi-polar Spare CCD 5 bias 12 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 5 bias 13 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 5 bias 14 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 5 bias 15 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground Bias voltages for CCD 6 CCD 6 bias 0 ADC 3385 ( d39) MUX 1.953 Volts 19.527 Vdd-1 CCD 6 bias 1 ADC 3316 ( cf4) MUX 1.852 Volts 18.518 Vdd-2 CCD 6 bias 2 ADC 2912 ( b60) MUX 1.260 Volts 12.603 RD-A CCD 6 bias 3 ADC 2912 ( b60) MUX 1.260 Volts 12.603 RD-B CCD 6 bias 4 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-A CCD 6 bias 5 ADC 3388 ( d3c) MUX 1.958 Volts 3.915 Spare-2 CCD 6 bias 6 ADC 2726 ( aa6) MUX 0.989 Volts 9.894 Guard ring CCD 6 bias 7 ADC 2048 ( 800) MUX -0.001 Volts -0.001 Substrate CCD 6 bias 8 ADC 3389 ( d3d) MUX 1.959 Volts 3.918 Spare-1 CCD 6 bias 9 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-B CCD 6 bias 10 ADC 3389 ( d3d) MUX 1.959 Volts 3.918 Spare-3 CCD 6 bias 11 ADC 2050 ( 802) MUX 0.001 Volts 0.015 Bi-polar Spare CCD 6 bias 12 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 6 bias 13 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 6 bias 14 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 6 bias 15 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground Bias voltages for CCD 7 CCD 7 bias 0 ADC 3316 ( cf4) MUX 1.852 Volts 18.518 Vdd-1 CCD 7 bias 1 ADC 3382 ( d36) MUX 1.948 Volts 19.483 Vdd-2 CCD 7 bias 2 ADC 2912 ( b60) MUX 1.260 Volts 12.603 RD-A CCD 7 bias 3 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-B CCD 7 bias 4 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-A CCD 7 bias 5 ADC 3389 ( d3d) MUX 1.959 Volts 3.918 Spare-2 CCD 7 bias 6 ADC 2726 ( aa6) MUX 0.989 Volts 9.894 Guard ring CCD 7 bias 7 ADC 2047 ( 7ff) MUX -0.003 Volts -0.003 Substrate CCD 7 bias 8 ADC 3392 ( d40) MUX 1.963 Volts 3.927 Spare-1 CCD 7 bias 9 ADC 2049 ( 801) MUX -0.001 Volts -0.002 OG-B CCD 7 bias 10 ADC 3390 ( d3e) MUX 1.961 Volts 3.921 Spare-3 CCD 7 bias 11 ADC 3388 ( d3c) MUX 1.958 Volts 19.576 Bi-polar Spare CCD 7 bias 12 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 7 bias 13 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 7 bias 14 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 7 bias 15 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground Bias voltages for CCD 8 CCD 8 bias 0 ADC 3316 ( cf4) MUX 1.852 Volts 18.518 Vdd-1 CCD 8 bias 1 ADC 3369 ( d29) MUX 1.929 Volts 19.293 Vdd-2 CCD 8 bias 2 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-A CCD 8 bias 3 ADC 2913 ( b61) MUX 1.262 Volts 12.617 RD-B CCD 8 bias 4 ADC 2051 ( 803) MUX 0.002 Volts 0.004 OG-A CCD 8 bias 5 ADC 3392 ( d40) MUX 1.963 Volts 3.927 Spare-2 CCD 8 bias 6 ADC 2726 ( aa6) MUX 0.989 Volts 9.894 Guard ring CCD 8 bias 7 ADC 2057 ( 809) MUX 0.012 Volts 0.012 Substrate CCD 8 bias 8 ADC 3389 ( d3d) MUX 1.959 Volts 3.918 Spare-1 CCD 8 bias 9 ADC 2051 ( 803) MUX 0.002 Volts 0.004 OG-B CCD 8 bias 10 ADC 3391 ( d3f) MUX 1.962 Volts 3.924 Spare-3 CCD 8 bias 11 ADC 2050 ( 802) MUX 0.001 Volts 0.015 Bi-polar Spare CCD 8 bias 12 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 8 bias 13 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 8 bias 14 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground CCD 8 bias 15 ADC 2050 ( 802) MUX 0.001 Volts 0.000 Ground 1 closed bias voltages were not within tolerance Check to see if something is loading down the affected bias voltages Low-rail clock voltages for clock gen 1 CLKGEN 1 clock 0 ADC 1642 ( 66a) MUX -0.594 Volts -5.944 CLKGEN 1 clock 1 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 1 clock 2 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 1 clock 3 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 1 clock 4 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 1 clock 5 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 1 clock 6 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 1 clock 7 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 1 clock 8 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 1 clock 9 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 1 clock 10 ADC 2048 ( 800) MUX 0.000 Volts 0.000 CLKGEN 1 clock 11 ADC 2050 ( 802) MUX 0.003 Volts 0.029 CLKGEN 1 clock 12 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 1 clock 13 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 1 clock 14 ADC 1642 ( 66a) MUX -0.594 Volts -5.944 CLKGEN 1 clock 15 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978 CLKGEN 1 clock 16 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 1 clock 17 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 1 clock 18 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 1 clock 19 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 1 clock 20 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 1 clock 21 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 1 clock 22 ADC 2048 ( 800) MUX 0.000 Volts 0.000 CLKGEN 1 clock 23 ADC 2049 ( 801) MUX 0.001 Volts 0.015 High-rail clock voltages for clock gen 1 CLKGEN 1 clock 0 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 1 clock 1 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 1 clock 2 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 1 clock 3 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 1 clock 4 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 1 clock 5 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 1 clock 6 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 1 clock 7 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 1 clock 8 ADC 2459 ( 99b) MUX 0.602 Volts 6.018 CLKGEN 1 clock 9 ADC 2391 ( 957) MUX 0.502 Volts 5.022 CLKGEN 1 clock 10 ADC 2594 ( a22) MUX 0.799 Volts 7.994 CLKGEN 1 clock 11 ADC 2595 ( a23) MUX 0.801 Volts 8.009 CLKGEN 1 clock 12 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 1 clock 13 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 1 clock 14 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 1 clock 15 ADC 2391 ( 957) MUX 0.502 Volts 5.022 CLKGEN 1 clock 16 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 1 clock 17 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 1 clock 18 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 1 clock 19 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 1 clock 20 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 1 clock 21 ADC 2391 ( 957) MUX 0.502 Volts 5.022 CLKGEN 1 clock 22 ADC 2594 ( a22) MUX 0.799 Volts 7.994 CLKGEN 1 clock 23 ADC 2594 ( a22) MUX 0.799 Volts 7.994 Low-rail clock voltages for clock gen 2 CLKGEN 2 clock 0 ADC 1642 ( 66a) MUX -0.594 Volts -5.944 CLKGEN 2 clock 1 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 2 clock 2 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 2 clock 3 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978 CLKGEN 2 clock 4 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 2 clock 5 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 2 clock 6 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 2 clock 7 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 2 clock 8 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 2 clock 9 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978 CLKGEN 2 clock 10 ADC 2048 ( 800) MUX 0.000 Volts 0.000 CLKGEN 2 clock 11 ADC 2049 ( 801) MUX 0.001 Volts 0.015 CLKGEN 2 clock 12 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 2 clock 13 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 2 clock 14 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 2 clock 15 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978 CLKGEN 2 clock 16 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 2 clock 17 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 2 clock 18 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 2 clock 19 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 2 clock 20 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 2 clock 21 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978 CLKGEN 2 clock 22 ADC 2048 ( 800) MUX 0.000 Volts 0.000 CLKGEN 2 clock 23 ADC 2049 ( 801) MUX 0.001 Volts 0.015 High-rail clock voltages for clock gen 2 CLKGEN 2 clock 0 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 2 clock 1 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 2 clock 2 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 2 clock 3 ADC 2391 ( 957) MUX 0.502 Volts 5.022 CLKGEN 2 clock 4 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 5 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 6 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 7 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 8 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 9 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 2 clock 10 ADC 2593 ( a21) MUX 0.798 Volts 7.980 CLKGEN 2 clock 11 ADC 2595 ( a23) MUX 0.801 Volts 8.009 CLKGEN 2 clock 12 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 2 clock 13 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 2 clock 14 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 2 clock 15 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 2 clock 16 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 17 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 18 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 19 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 20 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 2 clock 21 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 2 clock 22 ADC 2594 ( a22) MUX 0.799 Volts 7.994 CLKGEN 2 clock 23 ADC 2595 ( a23) MUX 0.801 Volts 8.009 Low-rail clock voltages for clock gen 3 CLKGEN 3 clock 0 ADC 1642 ( 66a) MUX -0.594 Volts -5.944 CLKGEN 3 clock 1 ADC 1642 ( 66a) MUX -0.594 Volts -5.944 CLKGEN 3 clock 2 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 3 clock 3 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 3 clock 4 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 3 clock 5 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 3 clock 6 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 3 clock 7 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 3 clock 8 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 3 clock 9 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 3 clock 10 ADC 2048 ( 800) MUX 0.000 Volts 0.000 CLKGEN 3 clock 11 ADC 2049 ( 801) MUX 0.001 Volts 0.015 CLKGEN 3 clock 12 ADC 1642 ( 66a) MUX -0.594 Volts -5.944 CLKGEN 3 clock 13 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 3 clock 14 ADC 1642 ( 66a) MUX -0.594 Volts -5.944 CLKGEN 3 clock 15 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 3 clock 16 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 3 clock 17 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 3 clock 18 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 3 clock 19 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 3 clock 20 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 3 clock 21 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 3 clock 22 ADC 2048 ( 800) MUX 0.000 Volts 0.000 CLKGEN 3 clock 23 ADC 2049 ( 801) MUX 0.001 Volts 0.015 High-rail clock voltages for clock gen 3 CLKGEN 3 clock 0 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 3 clock 1 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 3 clock 2 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 3 clock 3 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 3 clock 4 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 5 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 6 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 7 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 8 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 9 ADC 2389 ( 955) MUX 0.499 Volts 4.993 CLKGEN 3 clock 10 ADC 2593 ( a21) MUX 0.798 Volts 7.980 CLKGEN 3 clock 11 ADC 2593 ( a21) MUX 0.798 Volts 7.980 CLKGEN 3 clock 12 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 3 clock 13 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 3 clock 14 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 3 clock 15 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 3 clock 16 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 17 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 18 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 19 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 20 ADC 2457 ( 999) MUX 0.599 Volts 5.988 CLKGEN 3 clock 21 ADC 2389 ( 955) MUX 0.499 Volts 4.993 CLKGEN 3 clock 22 ADC 2592 ( a20) MUX 0.796 Volts 7.965 CLKGEN 3 clock 23 ADC 2593 ( a21) MUX 0.798 Volts 7.980 Low-rail clock voltages for clock gen 4 CLKGEN 4 clock 0 ADC 1642 ( 66a) MUX -0.594 Volts -5.944 CLKGEN 4 clock 1 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 4 clock 2 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 4 clock 3 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 4 clock 4 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 4 clock 5 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 4 clock 6 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 4 clock 7 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 4 clock 8 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 4 clock 9 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 4 clock 10 ADC 2048 ( 800) MUX 0.000 Volts 0.000 CLKGEN 4 clock 11 ADC 2049 ( 801) MUX 0.001 Volts 0.015 CLKGEN 4 clock 12 ADC 1642 ( 66a) MUX -0.594 Volts -5.944 CLKGEN 4 clock 13 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 4 clock 14 ADC 1641 ( 669) MUX -0.596 Volts -5.959 CLKGEN 4 clock 15 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963 CLKGEN 4 clock 16 ADC 1845 ( 735) MUX -0.297 Volts -2.972 CLKGEN 4 clock 17 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 4 clock 18 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 4 clock 19 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 4 clock 20 ADC 1844 ( 734) MUX -0.299 Volts -2.987 CLKGEN 4 clock 21 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978 CLKGEN 4 clock 22 ADC 2048 ( 800) MUX 0.000 Volts 0.000 CLKGEN 4 clock 23 ADC 2049 ( 801) MUX 0.001 Volts 0.015 High-rail clock voltages for clock gen 4 CLKGEN 4 clock 0 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 4 clock 1 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 4 clock 2 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 4 clock 3 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 4 clock 4 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 4 clock 5 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 4 clock 6 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 4 clock 7 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 4 clock 8 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 4 clock 9 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 4 clock 10 ADC 2593 ( a21) MUX 0.798 Volts 7.980 CLKGEN 4 clock 11 ADC 2594 ( a22) MUX 0.799 Volts 7.994 CLKGEN 4 clock 12 ADC 2186 ( 88a) MUX 0.202 Volts 2.020 CLKGEN 4 clock 13 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 4 clock 14 ADC 2185 ( 889) MUX 0.201 Volts 2.006 CLKGEN 4 clock 15 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 4 clock 16 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 4 clock 17 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 4 clock 18 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 4 clock 19 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 4 clock 20 ADC 2458 ( 99a) MUX 0.600 Volts 6.003 CLKGEN 4 clock 21 ADC 2390 ( 956) MUX 0.501 Volts 5.007 CLKGEN 4 clock 22 ADC 2593 ( a21) MUX 0.798 Volts 7.980 CLKGEN 4 clock 23 ADC 2595 ( a23) MUX 0.801 Volts 8.009 Closed clock voltages are all within tolerance Now commanding shutter closed +5v readback raw ADC reading = 3425 volts= 5.035361 prior to clocking +15v readback raw ADC reading = 3495 voltage = 16.071171 prior to clocking -15v readback raw ADC reading = 619 voltage = -16.069180 prior to clocking +30v readback raw ADC reading = 3281 volts = 34.594990 prior to clocking Sending IDL command to TIMING board CCD clocks are now running in idling mode value = 0 = 0x0 Verify that the restart script completed without error. If so, start the broadcast monitor task: -> < broadcast < broadcast taskSpawn("broad_mon", 110, 0x19, 10000, broadcast_mon, "/vx/deivme/dsp") value = 61894896 = 0x3b070f0 Start the dewar temperature monitor task: -> < dewartemp < dewartemp taskSpawn("dewar_temp", 160, 0x19, 20000, deimos_dewar_temperature,"", 1) value = 61881968 = 0x3b03e70 -> No file specified -> < ups < ups taskSpawn("shut_mon", 160, 0x19, 10000, shutmon, 0) value = 63140872 = 0x3c37408 Terminate login session: -> logout Connection closed.