JHKL photometric standards used at MSSSO (see PASP, 106, 508).
| Mount Stromlo and Siding Spring Observatories Near-IR Photometric Standards | ||||||||||
| Star | RA(2000) | Dec(2000) | m(a) | m(d) | Sp. Type | V | K | J-K | H-K | K-L |
| (s/yr) | ("/yr) | |||||||||
| Y 5817 | 00h 05m 24.4s | -37° 21' 26" | 0.4733 | -2.337 | M4 V | 8.63 | 4.529 | 0.753 | 0.214 | 0.172 |
| HR 33 | 00h 11m 15.8s | -15° 28' 05" | -0.0056 | -0.264 | F7 V | 4.89 | 3.646 | 0.290 | 0.034 | 0.018 |
| HR 77 | 00h 20m 04.2s | -64° 52' 30" | 0.3685 | 1.167 | F9 V | 4.23 | 2.832 | 0.334 | 0.039 | 0.021 |
| Y 392 | 01h 52m 49.0s | -22° 26' 06" | 0.0598 | 0.004 | M1 V | 8.7 | 5.223 | 0.838 | 0.168 | 0.110 |
| HR 612 | 02h 04m 29.4s | -29° 17' 49" | 0.0008 | 0.010 | B9.5pSi | 4.69 | 5.073 | -0.101 | -0.049 | -0.040 |
| HR 740 | 02h 32m 05.1s | -15° 14' 41" | -0.0053 | -0.117 | F4 IV | 4.75 | 3.589 | 0.270 | 0.033 | 0.013 |
| HR 818 | 02h 45m 06.1s | -18° 34' 21" | 0.0229 | 0.042 | F6 V | 4.47 | 3.344 | 0.251 | 0.040 | 0.009 |
| Y 642 | 03h 06m 26.7s | 01° 57' 57" | 0.0245 | -0.897 | M0 V | 9.10 | 5.674 | 0.804 | 0.140 | 0.078 |
| Y 1181 | 05h 11m 40.5s | -45° 01' 16" | 0.6156 | -5.734 | M0 V | 8.86 | 5.073 | 0.745 | 0.224 | 0.187 |
| Y 1255 | 05h 31m 27.3s | -03° 40' 39" | 0.0506 | -2.103 | M1 V | 7.98 | 3.886 | 0.889 | 0.189 | 0.120 |
| HR 1983 | 05h 44m 27.8s | -22° 26' 54" | -0.0212 | -0.373 | F6 V | 3.60 | 2.419 | 0.270 | 0.031 | 0.004 |
| HR 2015 | 05h 44m 46.5s | -65° 44' 08" | -0.0042 | 0.007 | A7 V | 4.35 | 3.723 | 0.135 | 0.026 | 0.012 |
| HR 2020 | 05h 47m 17.1s | -51° 03' 59" | 0.0005 | 0.087 | A5 V | 3.85 | 3.489 | 0.069 | 0.012 | 0.013 |
| HR 2085 | 05h 56m 24.2s | -14° 10' 04" | -0.0034 | 0.136 | F1 III | 3.71 | 2.908 | 0.172 | 0.027 | 0.010 |
| HR 2451 | 06h 37m 45.6s | -43° 11' 45" | -0.0006 | -0.005 | B8 III | 3.17 | 3.381 | -0.051 | -0.023 | -0.010 |
| HR 3314 | 08h 25m 39.6s | -03° 54' 23" | -0.0047 | -0.027 | A0 V | 3.90 | 3.930 | -0.016 | -0.008 | -0.021 |
| Y 2267 | 09h 31m 19.6s | -13° 29' 18" | 0.0500 | 0.059 | M4 V | 10.04 | 5.554 | 0.847 | 0.243 | 0.185 |
| HR 3842 | 09h 38m 01.4s | -43° 11' 27" | 0.0022 | -0.035 | G8 II | 5.50 | 3.409 | 0.538 | 0.084 | 0.055 |
| HR 3871 | 09h 44m 12.1s | -27° 46' 10" | -0.0037 | 0.030 | A8 V | 4.79 | 3.255 | 0.440 | 0.072 | 0.038 |
| V 569 | 10h 12m 17.6s | -03° 44' 43" | -0.0105 | -0.232 | M2 V | 9.30 | 5.034 | 0.869 | 0.222 | 0.142 |
| HR 4102 | 10h 24m 23.7s | -74° 01' 54" | -0.0044 | -0.031 | F2 IV | 4.00 | 3.140 | 0.186 | 0.026 | 0.004 |
| HR 4450 | 11h 33m 00.1s | -31° 51' 27" | -0.0162 | -0.042 | G7 III | 3.54 | 1.448 | 0.548 | 0.087 | 0.058 |
| HR 4638 | 12h 11m 39.1s | -52° 22' 06" | -0.0038 | -0.019 | B3 V | 3.96 | 4.449 | -0.125 | -0.052 | -0.052 |
| HR 4773 | 12h 32m 28.0s | -72° 07' 58" | -0.0104 | -0.009 | B5 V | 3.87 | 4.303 | -0.122 | -0.050 | -0.054 |
| HR 4802 | 12h 37m 42.1s | -48° 32' 28" | -0.0187 | -0.008 | A2 V | 3.86 | 3.710 | 0.035 | 0.010 | 0.004 |
| Y 2951 | 12h 50m 43.5s | -00° 46' 05" | -0.0029 | -0.395 | M0 V | 8.51 | 4.957 | 0.832 | 0.160 | 0.073 |
| HR 4989 | 13h 14m 14.7s | -59° 06' 12" | -0.0339 | -0.161 | F7 IV | 4.92 | 3.684 | 0.301 | 0.041 | 0.008 |
| HR 5028 | 13h 20m 35.7s | -36° 42' 44" | -0.0283 | -0.089 | A2 V | 2.75 | 2.697 | 0.007 | 0.000 | -0.002 |
| HR 5249 | 13h 58m 40.7s | -44° 48' 13" | -0.0024 | -0.024 | B2 IV-V | 3.87 | 4.509 | -0.165 | -0.070 | -0.065 |
| Y 3269 | 14h 34m 16.7s | -12° 31' 13" | -0.0233 | 0.599 | M4 V | 11.36 | 5.986 | 0.894 | 0.294 | 0.230 |
| Y 3375B | 14h 57m 26.6s | -21° 24' 44" | 0.0731 | -1.713 | M2 V | 7.91 | 3.938 | 0.859 | 0.217 | 0.170 |
| Y 3501 | 15h 32m 13.1s | -41° 16' 35" | -0.1022 | -1.020 | M4 V | 9.30 | 4.792 | 0.876 | 0.242 | 0.186 |
| Y 3746 | 16h 30m 18.0s | -12° 39' 48" | -0.0048 | -1.173 | M4 V | 10.10 | 5.115 | 0.847 | 0.273 | 0.227 |
| HR 6147 | 16h 31m 08.2s | -16° 36' 46" | -0.0037 | -0.038 | G8 IIIa | 4.28 | 2.274 | 0.506 | 0.092 | 0.049 |
| Y 3845 | 16h 55m 28.9s | -08° 20' 10" | -0.0542 | -0.877 | M3eV | 8.98 | 4.420 | 0.821 | 0.243 | 0.199 |
| HR 6378 | 17h 10m 22.6s | -15° 43' 29" | 0.0026 | 0.095 | A2 V | 2.43 | 2.275 | 0.018 | 0.011 | 0.006 |
| Y 3958 | 17h 28m 40.2s | -46° 53' 45" | 0.0555 | -0.876 | M4 V | 9.36 | 4.888 | 0.833 | 0.247 | 0.200 |
| Y 3992 | 17h 37m 03.4s | -44° 19' 11" | -0.0637 | -0.931 | M5 | 11.2 | 5.658 | 0.925 | 0.282 | 0.240 |
| Y 4338 | 18h 49m 50.0s | -23° 50' 12" | 0.0503 | -0.207 | M4eV | 10.95 | 5.380 | 0.850 | 0.293 | 0.257 |
| HR 7340 | 19h 21m 40.3s | -17° 50' 50" | -0.0018 | 0.024 | F0 IV-V | 3.93 | 3.371 | 0.120 | 0.026 | 0.015 |
| Y 4794 | 20h 13m 53.3s | -45° 09' 47" | 0.0726 | -0.133 | M0 V | 7.97 | 4.279 | 0.830 | 0.186 | 0.125 |
| HR 7773 | 20h 20m 39.7s | -12° 45' 33" | 0.0011 | -0.018 | B9.5 V | 4.76 | 4.854 | -0.040 | -0.006 | 0.002 |
| Y 4924 | 20h 42m 18.4s | -52° 41' 56" | 0.0074 | -1.067 | K7 V | 8.83 | 5.504 | 0.803 | 0.147 | 0.093 |
| HR 7950 | 20h 47m 40.5s | -09° 29' 45" | 0.0022 | -0.032 | A1 V | 3.77 | 3.697 | 0.007 | 0.005 | 0.016 |
| Y 5117 | 21h 17m 15.0s | -38° 52' 06" | -0.2787 | -1.153 | M0 V | 6.67 | 3.078 | 0.832 | 0.162 | 0.110 |
| Y 5190 | 21h 33m 34.0s | -49° 00' 32" | -0.0055 | -0.798 | M1 V | 8.68 | 4.482 | 0.822 | 0.225 | 0.178 |
| HR 8278 | 21h 40m 05.4s | -16° 39' 45" | 0.0131 | -0.022 | F0p | 3.68 | 3.045 | 0.128 | 0.024 | 0.020 |
| Y 5243 | 21h 46m 35.9s | -57° 42' 11" | 0.0120 | -0.873 | K7 V | 8.80 | 5.464 | 0.803 | 0.153 | 0.085 |
| Y 5358 | 22h 09m 39.9s | -04° 38' 28" | 0.0693 | -0.027 | M3 V | 10.12 | 5.626 | 0.900 | 0.249 | 0.185 |
| Y 5475 | 22h 38m 33.5s | -15° 18' 00" | 0.1634 | 2.236 | M6eV | 12.18 | 5.591 | 0.978 | 0.364 | 0.315 |
| Y 5546 | 22h 53m 17.1s | -14° 15' 45" | 0.0656 | -0.631 | M5 V | 10.10 | 5.044 | 0.896 | 0.276 | 0.217 |
| HR 8709 | 22h 54m 38.9s | -15° 49' 15" | -0.0029 | -0.022 | A3 V | 3.27 | 3.067 | 0.046 | 0.014 | 0.010 |
| Y 5572 | 23h 00m 16.0s | -22° 31' 28" | -0.0658 | 0.062 | M1 V | 7.90 | 4.486 | 0.808 | 0.152 | 0.093 |
| Y 5584 | 23h 05m 52.0s | -35° 51' 12" | 0.5575 | 1.330 | M2 V | 7.34 | 3.382 | 0.829 | 0.218 | 0.162 |
| HR 8848 | 23h 17m 25.7s | -58° 14' 08" | -0.0032 | 0.089 | F1 III | 3.99 | 2.967 | 0.233 | 0.034 | 0.021 |