This page shows the commands required to manually start all K1AO
tools when using the upgraded RTC.
The following commands can be run on a k1aoserver-new
terminal as k1obsao.
Define variables
- set num = `inst2tel`
- set tel = `echo "k"$num`
- set acct = `echo $tel"obsao"`
- set server = `echo $tel"aoserver-new"`
- set lacct = `echo $tel"laser"`
- set lserver = `echo $tel"laserserver"`
- modify -s ao aoopsmode=2
SC GUI
LBWFS Image Acquisition Tool
LBWFS Manager
MAORI GUI
STRAP status GUI
Reconstructor process
Fault Detector
Optimization Tool
AO Alarm Handler (does not work)
- /home/$acct/bin/restart_alhao -$tel &
- restart_alhao -$tel &
TBAD Status GUI
Spiral Tool
- Start Solaris version of spacecom
- spiral.csh &
- Load idl_opensYYMMDD.sav, where YYMMDD is
current UTC date
LUI
Tip Tilt Graphs
Laser Geevum
K1 FST Sequencer
TRICK Manager (optional)
TRICK Offset Detection and Acquisition (optional)
OA Permissive UI
Iss Top UI
LGS Alarm Handler
AO Acquisition GUI
Open a k1aoserver-new terminal as k1obsao and type:
- cd /home/k1obsao/sragland/idl2release/RTCU/
- IDL
- IDL>.r ./aoacq.pro
- IDL>aoacq
WFS Status GUI
Open a k1aoserver-new terminal as k1obsao and type:
- cd /home/k1obsao/sragland/idl2release/RTCU/
- ./wfsstatus.csh &
ACAM tool
As k1obsao at k1aoserver-new (v4.2):
As k1obsao at k1aoserver (v6.0):
- setenv EPICS_CA_ADDR_LIST "k1supserver:5064 k1aoserver-new:5064 k1laserserver-kapa:5064"
- acamtool.csh &
Any ACAM images must be taken from the Solaris version.
spacecom
As k1obsao at k1aoserver:
- setenv EPICS_CA_ADDR_LIST "k1supserver:5064 k1aoserver-new:5064 k1laserserver-kapa:5064"
- cdn
- spacecom
Check that the output looks normal then you may minimize the xterm.
LTCS
As aodev at kapoli:
- setenv EPICS_CA_ADDR_LIST "k1supserver:5064 k1aoserver-new:5064 k1laserserver-kapa:5064"
- stop_ltcs (or stop_ltcs forcekill
if stop_ltcs fails to stop LTCS
- OA_startup.rtcu
- init_ltcs_queries