l(nm) 298K -------------- 2240.00 0.03 2241.00 0.03 2242.00 0.04 2243.00 0.04 2244.00 0.05 2245.00 0.05 2246.00 0.05 2247.00 0.05 2248.00 0.06 2249.00 0.06 2250.00 0.07 2251.00 0.08 2252.00 0.09 2253.00 0.10 2254.00 0.10 2255.00 0.12 2256.00 0.13 2257.00 0.15 2258.00 0.16 2259.00 0.18 2260.00 0.21 2261.00 0.23 2262.00 0.26 2263.00 0.30 2264.00 0.34 2265.00 0.39 2266.00 0.45 2267.00 0.52 2268.00 0.60 2269.00 0.70 2270.00 0.81 2271.00 0.95 2272.00 1.10 2273.00 1.31 2274.00 1.53 2275.00 1.82 2276.00 2.16 2277.00 2.57 2278.00 3.07 2279.00 3.69 2280.00 4.47 2281.00 5.40 2282.00 6.56 2283.00 8.03 2284.00 9.74 2285.00 11.93 2286.00 14.60 2287.00 17.80 2288.00 21.56 2289.00 26.17 2290.00 31.19 2291.00 36.76 2292.00 43.06 2293.00 49.15 2294.00 55.25 2295.00 60.80 2296.00 65.70 2297.00 69.66 2298.00 72.69 2299.00 74.80 2300.00 76.08 2301.00 76.69 2302.00 76.83 2303.00 76.63 2304.00 76.27 2305.00 75.79 2306.00 75.30 2307.00 74.85 2308.00 74.46 2309.00 74.13 2310.00 73.90 2311.00 73.74 2312.00 73.64 2313.00 73.62 2314.00 73.66 2315.00 73.72 2316.00 73.80 2317.00 73.93 2318.00 74.11 2319.00 74.24 2320.00 74.44 2321.00 74.63 2322.00 74.84 2323.00 75.09 2324.00 75.34 2325.00 75.64 2326.00 75.92 2327.00 76.28 2328.00 76.63 2329.00 77.00 2330.00 77.45 2331.00 77.92 2332.00 78.39 2333.00 78.92 2334.00 79.47 2335.00 80.03 2336.00 80.59 2337.00 81.20 2338.00 81.80 2339.00 82.38 2340.00 82.94 2341.00 83.48 2342.00 83.98 2343.00 84.39 2344.00 84.81 2345.00 85.14 2346.00 85.38 2347.00 85.58 2348.00 85.72 2349.00 85.75 2350.00 85.71 2351.00 85.64 2352.00 85.44 2353.00 85.19 2354.00 84.92 2355.00 84.63 2356.00 84.24 2357.00 83.86 2358.00 83.50 2359.00 83.10 2360.00 82.68 2361.00 82.36 2362.00 82.02 2363.00 81.69 2364.00 81.43 2365.00 81.22 2366.00 81.07 2367.00 80.93 2368.00 80.90 2369.00 80.89 2370.00 80.91 2371.00 81.00 2372.00 81.12 2373.00 81.24 2374.00 81.41 2375.00 81.62 2376.00 81.79 2377.00 81.96 2378.00 82.13 2379.00 82.29 2380.00 82.40 2381.00 82.50 2382.00 82.58 2383.00 82.58 2384.00 82.59 2385.00 82.59 2386.00 82.58 2387.00 82.56 2388.00 82.56 2389.00 82.59 2390.00 82.67 2391.00 82.78 2392.00 83.01 2393.00 83.27 2394.00 83.58 2395.00 83.98 2396.00 84.41 2397.00 84.74 2398.00 84.94 2399.00 84.91 2400.00 84.44 2401.00 83.41 2402.00 81.60 2403.00 78.74 2404.00 75.01 2405.00 70.33 2406.00 64.38 2407.00 58.19 2408.00 51.42 2409.00 44.35 2410.00 38.14 2411.00 32.04 2412.00 26.64 2413.00 22.06 2414.00 18.10 2415.00 14.76 2416.00 12.13 2417.00 9.98 2418.00 8.17 2419.00 6.71 2420.00 5.57 2421.00 4.62 2422.00 3.84 2423.00 3.23 2424.00 2.72 2425.00 2.28 2426.00 1.94 2427.00 1.65 2428.00 1.40 2429.00 1.21 2430.00 1.05 2431.00 0.90 2432.00 0.78 2433.00 0.68 2434.00 0.59 2435.00 0.52 2436.00 0.45 2437.00 0.40 2438.00 0.36 2439.00 0.31 2440.00 0.28 2441.00 0.25 2442.00 0.22 2443.00 0.20 2444.00 0.18 2445.00 0.16 2446.00 0.14 2447.00 0.13 2448.00 0.12 2449.00 0.11 2450.00 0.10 2451.00 0.09 2452.00 0.08 2453.00 0.08 2454.00 0.07 2455.00 0.07 2456.00 0.06 2457.00 0.06 2458.00 0.05 2459.00 0.04 2460.00 0.04 2461.00 0.04 2462.00 0.04 2463.00 0.04 2464.00 0.03 2465.00 0.03 2466.00 0.03 2467.00 0.02 2468.00 0.02 2469.00 0.02 2470.00 0.02