l(nm) 298K -------------- 1895.00 0.01 1895.10 0.00 1895.20 0.00 1895.30 0.01 1895.40 0.00 1895.50 0.00 1895.60 0.01 1895.70 -0.00 1895.80 0.00 1895.90 0.01 1896.00 -0.00 1896.10 0.00 1896.20 0.00 1896.30 0.00 1896.40 0.00 1896.50 0.01 1896.60 0.01 1896.70 0.01 1896.80 0.01 1896.90 -0.00 1897.00 0.01 1897.10 0.00 1897.20 0.01 1897.30 0.01 1897.40 0.01 1897.50 0.00 1897.60 0.00 1897.70 0.01 1897.80 0.00 1897.90 0.00 1898.00 0.00 1898.10 0.00 1898.20 0.00 1898.30 0.01 1898.40 0.00 1898.50 0.00 1898.60 0.01 1898.70 0.01 1898.80 0.00 1898.90 0.01 1899.00 0.00 1899.10 0.01 1899.20 0.01 1899.30 0.00 1899.40 0.01 1899.50 0.01 1899.60 0.01 1899.70 0.01 1899.80 0.01 1899.90 0.00 1900.00 0.01 1900.10 0.01 1900.20 0.01 1900.30 0.01 1900.40 0.01 1900.50 0.01 1900.60 0.00 1900.70 0.01 1900.80 0.01 1900.90 0.01 1901.00 0.01 1901.10 0.01 1901.20 0.01 1901.30 0.01 1901.40 0.00 1901.50 0.01 1901.60 0.01 1901.70 0.01 1901.80 0.01 1901.90 0.01 1902.00 0.01 1902.10 0.01 1902.20 0.01 1902.30 0.01 1902.40 0.01 1902.50 0.01 1902.60 0.01 1902.70 0.01 1902.80 0.01 1902.90 0.01 1903.00 0.01 1903.10 0.01 1903.20 0.01 1903.30 0.01 1903.40 0.01 1903.50 0.02 1903.60 0.01 1903.70 0.01 1903.80 0.01 1903.90 0.01 1904.00 0.01 1904.10 0.01 1904.20 0.01 1904.30 0.02 1904.40 0.01 1904.50 0.01 1904.60 0.01 1904.70 0.01 1904.80 0.01 1904.90 0.01 1905.00 0.01 1905.10 0.01 1905.20 0.01 1905.30 0.01 1905.40 0.01 1905.50 0.02 1905.60 0.01 1905.70 0.01 1905.80 0.01 1905.90 0.01 1906.00 0.01 1906.10 0.02 1906.20 0.01 1906.30 0.02 1906.40 0.01 1906.50 0.01 1906.60 0.01 1906.70 0.01 1906.80 0.01 1906.90 0.01 1907.00 0.01 1907.10 0.02 1907.20 0.02 1907.30 0.02 1907.40 0.02 1907.50 0.02 1907.60 0.01 1907.70 0.01 1907.80 0.02 1907.90 0.01 1908.00 0.01 1908.10 0.02 1908.20 0.02 1908.30 0.02 1908.40 0.02 1908.50 0.02 1908.60 0.02 1908.70 0.02 1908.80 0.02 1908.90 0.03 1909.00 0.02 1909.10 0.02 1909.20 0.02 1909.30 0.01 1909.40 0.02 1909.50 0.02 1909.60 0.02 1909.70 0.02 1909.80 0.02 1909.90 0.02 1910.00 0.02 1910.10 0.02 1910.20 0.02 1910.30 0.02 1910.40 0.03 1910.50 0.02 1910.60 0.02 1910.70 0.03 1910.80 0.02 1910.90 0.03 1911.00 0.02 1911.10 0.02 1911.20 0.02 1911.30 0.02 1911.40 0.02 1911.50 0.02 1911.60 0.02 1911.70 0.03 1911.80 0.02 1911.90 0.02 1912.00 0.03 1912.10 0.03 1912.20 0.03 1912.30 0.03 1912.40 0.03 1912.50 0.02 1912.60 0.03 1912.70 0.02 1912.80 0.03 1912.90 0.03 1913.00 0.03 1913.10 0.03 1913.20 0.03 1913.30 0.02 1913.40 0.03 1913.50 0.03 1913.60 0.03 1913.70 0.03 1913.80 0.04 1913.90 0.03 1914.00 0.03 1914.10 0.02 1914.20 0.03 1914.30 0.03 1914.40 0.03 1914.50 0.03 1914.60 0.04 1914.70 0.03 1914.80 0.03 1914.90 0.03 1915.00 0.04 1915.10 0.04 1915.20 0.04 1915.30 0.04 1915.40 0.04 1915.50 0.03 1915.60 0.04 1915.70 0.04 1915.80 0.04 1915.90 0.04 1916.00 0.04 1916.10 0.05 1916.20 0.04 1916.30 0.04 1916.40 0.04 1916.50 0.04 1916.60 0.04 1916.70 0.04 1916.80 0.04 1916.90 0.04 1917.00 0.04 1917.10 0.05 1917.20 0.05 1917.30 0.05 1917.40 0.05 1917.50 0.05 1917.60 0.05 1917.70 0.05 1917.80 0.05 1917.90 0.05 1918.00 0.05 1918.10 0.05 1918.20 0.05 1918.30 0.05 1918.40 0.05 1918.50 0.05 1918.60 0.05 1918.70 0.05 1918.80 0.06 1918.90 0.05 1919.00 0.06 1919.10 0.06 1919.20 0.06 1919.30 0.06 1919.40 0.06 1919.50 0.06 1919.60 0.06 1919.70 0.06 1919.80 0.07 1919.90 0.07 1920.00 0.06 1920.10 0.06 1920.20 0.07 1920.30 0.07 1920.40 0.07 1920.50 0.07 1920.60 0.07 1920.70 0.07 1920.80 0.07 1920.90 0.07 1921.00 0.08 1921.10 0.08 1921.20 0.07 1921.30 0.08 1921.40 0.08 1921.50 0.08 1921.60 0.08 1921.70 0.08 1921.80 0.09 1921.90 0.08 1922.00 0.08 1922.10 0.09 1922.20 0.09 1922.30 0.09 1922.40 0.09 1922.50 0.09 1922.60 0.09 1922.70 0.09 1922.80 0.09 1922.90 0.10 1923.00 0.09 1923.10 0.10 1923.20 0.10 1923.30 0.10 1923.40 0.10 1923.50 0.10 1923.60 0.10 1923.70 0.10 1923.80 0.11 1923.90 0.11 1924.00 0.11 1924.10 0.11 1924.20 0.12 1924.30 0.11 1924.40 0.12 1924.50 0.12 1924.60 0.12 1924.70 0.12 1924.80 0.12 1924.90 0.12 1925.00 0.13 1925.10 0.13 1925.20 0.13 1925.30 0.13 1925.40 0.14 1925.50 0.14 1925.60 0.14 1925.70 0.14 1925.80 0.14 1925.90 0.14 1926.00 0.15 1926.10 0.15 1926.20 0.15 1926.30 0.16 1926.40 0.15 1926.50 0.16 1926.60 0.16 1926.70 0.17 1926.80 0.17 1926.90 0.16 1927.00 0.17 1927.10 0.17 1927.20 0.17 1927.30 0.18 1927.40 0.18 1927.50 0.18 1927.60 0.19 1927.70 0.19 1927.80 0.19 1927.90 0.19 1928.00 0.20 1928.10 0.20 1928.20 0.20 1928.30 0.21 1928.40 0.21 1928.50 0.21 1928.60 0.22 1928.70 0.23 1928.80 0.23 1928.90 0.23 1929.00 0.22 1929.10 0.24 1929.20 0.24 1929.30 0.24 1929.40 0.25 1929.50 0.25 1929.60 0.26 1929.70 0.26 1929.80 0.26 1929.90 0.26 1930.00 0.27 1930.10 0.28 1930.20 0.28 1930.30 0.29 1930.40 0.29 1930.50 0.30 1930.60 0.30 1930.70 0.30 1930.80 0.31 1930.90 0.31 1931.00 0.32 1931.10 0.32 1931.20 0.33 1931.30 0.33 1931.40 0.34 1931.50 0.34 1931.60 0.35 1931.70 0.36 1931.80 0.36 1931.90 0.37 1932.00 0.38 1932.10 0.38 1932.20 0.39 1932.30 0.39 1932.40 0.40 1932.50 0.41 1932.60 0.42 1932.70 0.43 1932.80 0.43 1932.90 0.44 1933.00 0.45 1933.10 0.45 1933.20 0.46 1933.30 0.47 1933.40 0.48 1933.50 0.48 1933.60 0.49 1933.70 0.50 1933.80 0.51 1933.90 0.52 1934.00 0.53 1934.10 0.54 1934.20 0.55 1934.30 0.56 1934.40 0.56 1934.50 0.58 1934.60 0.59 1934.70 0.60 1934.80 0.60 1934.90 0.62 1935.00 0.63 1935.10 0.64 1935.20 0.65 1935.30 0.67 1935.40 0.68 1935.50 0.69 1935.60 0.70 1935.70 0.72 1935.80 0.73 1935.90 0.74 1936.00 0.76 1936.10 0.77 1936.20 0.79 1936.30 0.80 1936.40 0.81 1936.50 0.83 1936.60 0.85 1936.70 0.86 1936.80 0.87 1936.90 0.90 1937.00 0.91 1937.10 0.93 1937.20 0.95 1937.30 0.97 1937.40 0.98 1937.50 1.01 1937.60 1.02 1937.70 1.05 1937.80 1.06 1937.90 1.08 1938.00 1.10 1938.10 1.13 1938.20 1.15 1938.30 1.17 1938.40 1.20 1938.50 1.22 1938.60 1.25 1938.70 1.27 1938.80 1.29 1938.90 1.32 1939.00 1.35 1939.10 1.37 1939.20 1.41 1939.30 1.43 1939.40 1.46 1939.50 1.49 1939.60 1.52 1939.70 1.55 1939.80 1.58 1939.90 1.61 1940.00 1.65 1940.10 1.68 1940.20 1.72 1940.30 1.75 1940.40 1.79 1940.50 1.83 1940.60 1.87 1940.70 1.90 1940.80 1.95 1940.90 1.99 1941.00 2.03 1941.10 2.07 1941.20 2.12 1941.30 2.16 1941.40 2.21 1941.50 2.25 1941.60 2.29 1941.70 2.35 1941.80 2.40 1941.90 2.44 1942.00 2.50 1942.10 2.55 1942.20 2.60 1942.30 2.66 1942.40 2.72 1942.50 2.78 1942.60 2.84 1942.70 2.90 1942.80 2.98 1942.90 3.04 1943.00 3.10 1943.10 3.17 1943.20 3.25 1943.30 3.32 1943.40 3.39 1943.50 3.46 1943.60 3.55 1943.70 3.63 1943.80 3.71 1943.90 3.79 1944.00 3.87 1944.10 3.98 1944.20 4.06 1944.30 4.16 1944.40 4.25 1944.50 4.36 1944.60 4.46 1944.70 4.57 1944.80 4.67 1944.90 4.78 1945.00 4.89 1945.10 5.00 1945.20 5.11 1945.30 5.23 1945.40 5.35 1945.50 5.48 1945.60 5.61 1945.70 5.74 1945.80 5.88 1945.90 6.03 1946.00 6.17 1946.10 6.31 1946.20 6.46 1946.30 6.61 1946.40 6.78 1946.50 6.94 1946.60 7.10 1946.70 7.28 1946.80 7.44 1946.90 7.63 1947.00 7.79 1947.10 7.99 1947.20 8.19 1947.30 8.39 1947.40 8.57 1947.50 8.78 1947.60 9.01 1947.70 9.23 1947.80 9.45 1947.90 9.69 1948.00 9.92 1948.10 10.17 1948.20 10.40 1948.30 10.63 1948.40 10.95 1948.50 11.16 1948.60 11.46 1948.70 11.70 1948.80 12.01 1948.90 12.30 1949.00 12.63 1949.10 12.89 1949.20 13.22 1949.30 13.55 1949.40 13.87 1949.50 14.20 1949.60 14.55 1949.70 14.93 1949.80 15.26 1949.90 15.62 1950.00 15.97 1950.10 16.39 1950.20 16.74 1950.30 17.15 1950.40 17.53 1950.50 17.96 1950.60 18.43 1950.70 18.85 1950.80 19.26 1950.90 19.71 1951.00 20.22 1951.10 20.65 1951.20 21.17 1951.30 21.66 1951.40 22.16 1951.50 22.66 1951.60 23.21 1951.70 23.69 1951.80 24.22 1951.90 24.79 1952.00 25.33 1952.10 25.92 1952.20 26.43 1952.30 27.07 1952.40 27.68 1952.50 28.23 1952.60 28.82 1952.70 29.48 1952.80 30.11 1952.90 30.79 1953.00 31.43 1953.10 32.07 1953.20 32.78 1953.30 33.45 1953.40 34.08 1953.50 34.85 1953.60 35.53 1953.70 36.16 1953.80 36.93 1953.90 37.55 1954.00 38.36 1954.10 39.08 1954.20 39.77 1954.30 40.49 1954.40 41.25 1954.50 42.02 1954.60 42.80 1954.70 43.55 1954.80 44.30 1954.90 45.10 1955.00 45.86 1955.10 46.55 1955.20 47.34 1955.30 48.11 1955.40 48.83 1955.50 49.63 1955.60 50.32 1955.70 51.14 1955.80 51.97 1955.90 52.66 1956.00 53.35 1956.10 54.16 1956.20 55.03 1956.30 55.66 1956.40 56.47 1956.50 57.13 1956.60 57.94 1956.70 58.67 1956.80 59.36 1956.90 59.95 1957.00 60.71 1957.10 61.42 1957.20 62.13 1957.30 62.71 1957.40 63.42 1957.50 64.19 1957.60 64.75 1957.70 65.35 1957.80 66.00 1957.90 66.63 1958.00 67.25 1958.10 67.89 1958.20 68.37 1958.30 69.02 1958.40 69.61 1958.50 70.14 1958.60 70.67 1958.70 71.12 1958.80 71.64 1958.90 72.17 1959.00 72.61 1959.10 73.11 1959.20 73.64 1959.30 74.02 1959.40 74.46 1959.50 74.87 1959.60 75.28 1959.70 75.69 1959.80 76.12 1959.90 76.39 1960.00 76.77 1960.10 77.15 1960.20 77.44 1960.30 77.76 1960.40 78.06 1960.50 78.38 1960.60 78.65 1960.70 78.94 1960.80 79.22 1960.90 79.50 1961.00 79.70 1961.10 79.96 1961.20 80.15 1961.30 80.34 1961.40 80.55 1961.50 80.74 1961.60 80.91 1961.70 81.06 1961.80 81.22 1961.90 81.41 1962.00 81.52 1962.10 81.65 1962.20 81.77 1962.30 81.92 1962.40 82.05 1962.50 82.11 1962.60 82.23 1962.70 82.34 1962.80 82.41 1962.90 82.47 1963.00 82.57 1963.10 82.63 1963.20 82.70 1963.30 82.74 1963.40 82.81 1963.50 82.89 1963.60 82.90 1963.70 82.91 1963.80 82.97 1963.90 83.01 1964.00 83.07 1964.10 83.05 1964.20 83.07 1964.30 83.12 1964.40 83.12 1964.50 83.14 1964.60 83.19 1964.70 83.18 1964.80 83.23 1964.90 83.22 1965.00 83.24 1965.10 83.25 1965.20 83.23 1965.30 83.21 1965.40 83.25 1965.50 83.21 1965.60 83.21 1965.70 83.21 1965.80 83.26 1965.90 83.24 1966.00 83.23 1966.10 83.23 1966.20 83.26 1966.30 83.24 1966.40 83.25 1966.50 83.27 1966.60 83.27 1966.70 83.29 1966.80 83.29 1966.90 83.28 1967.00 83.33 1967.10 83.29 1967.20 83.28 1967.30 83.27 1967.40 83.26 1967.50 83.31 1967.60 83.26 1967.70 83.29 1967.80 83.26 1967.90 83.28 1968.00 83.26 1968.10 83.32 1968.20 83.27 1968.30 83.33 1968.40 83.32 1968.50 83.34 1968.60 83.38 1968.70 83.42 1968.80 83.43 1968.90 83.45 1969.00 83.48 1969.10 83.53 1969.20 83.55 1969.30 83.55 1969.40 83.59 1969.50 83.64 1969.60 83.62 1969.70 83.61 1969.80 83.70 1969.90 83.70 1970.00 83.75 1970.10 83.74 1970.20 83.75 1970.30 83.82 1970.40 83.83 1970.50 83.88 1970.60 83.93 1970.70 83.97 1970.80 84.03 1970.90 84.06 1971.00 84.13 1971.10 84.19 1971.20 84.18 1971.30 84.24 1971.40 84.31 1971.50 84.31 1971.60 84.39 1971.70 84.39 1971.80 84.44 1971.90 84.50 1972.00 84.51 1972.10 84.55 1972.20 84.62 1972.30 84.66 1972.40 84.69 1972.50 84.74 1972.60 84.80 1972.70 84.87 1972.80 84.91 1972.90 84.99 1973.00 85.08 1973.10 85.13 1973.20 85.16 1973.30 85.23 1973.40 85.28 1973.50 85.37 1973.60 85.40 1973.70 85.45 1973.80 85.51 1973.90 85.57 1974.00 85.63 1974.10 85.64 1974.20 85.71 1974.30 85.76 1974.40 85.80 1974.50 85.85 1974.60 85.89 1974.70 85.97 1974.80 86.04 1974.90 86.08 1975.00 86.17 1975.10 86.23 1975.20 86.29 1975.30 86.35 1975.40 86.43 1975.50 86.49 1975.60 86.54 1975.70 86.56 1975.80 86.60 1975.90 86.67 1976.00 86.72 1976.10 86.77 1976.20 86.85 1976.30 86.85 1976.40 86.96 1976.50 87.00 1976.60 87.06 1976.70 87.14 1976.80 87.17 1976.90 87.22 1977.00 87.31 1977.10 87.32 1977.20 87.41 1977.30 87.44 1977.40 87.48 1977.50 87.55 1977.60 87.59 1977.70 87.65 1977.80 87.74 1977.90 87.78 1978.00 87.75 1978.10 87.80 1978.20 87.84 1978.30 87.92 1978.40 87.90 1978.50 88.00 1978.60 88.05 1978.70 88.07 1978.80 88.14 1978.90 88.22 1979.00 88.25 1979.10 88.33 1979.20 88.31 1979.30 88.36 1979.40 88.40 1979.50 88.46 1979.60 88.46 1979.70 88.49 1979.80 88.51 1979.90 88.51 1980.00 88.61 1980.10 88.59 1980.20 88.64 1980.30 88.69 1980.40 88.69 1980.50 88.75 1980.60 88.79 1980.70 88.81 1980.80 88.87 1980.90 88.90 1981.00 88.88 1981.10 88.95 1981.20 88.97 1981.30 89.03 1981.40 89.04 1981.50 89.04 1981.60 89.10 1981.70 89.06 1981.80 89.10 1981.90 89.19 1982.00 89.18 1982.10 89.21 1982.20 89.22 1982.30 89.25 1982.40 89.21 1982.50 89.22 1982.60 89.23 1982.70 89.26 1982.80 89.27 1982.90 89.26 1983.00 89.29 1983.10 89.29 1983.20 89.32 1983.30 89.33 1983.40 89.35 1983.50 89.39 1983.60 89.42 1983.70 89.44 1983.80 89.43 1983.90 89.46 1984.00 89.47 1984.10 89.43 1984.20 89.47 1984.30 89.47 1984.40 89.46 1984.50 89.44 1984.60 89.46 1984.70 89.44 1984.80 89.43 1984.90 89.46 1985.00 89.48 1985.10 89.49 1985.20 89.51 1985.30 89.48 1985.40 89.50 1985.50 89.49 1985.60 89.47 1985.70 89.47 1985.80 89.46 1985.90 89.50 1986.00 89.45 1986.10 89.44 1986.20 89.46 1986.30 89.45 1986.40 89.47 1986.50 89.45 1986.60 89.44 1986.70 89.47 1986.80 89.44 1986.90 89.40 1987.00 89.41 1987.10 89.34 1987.20 89.36 1987.30 89.36 1987.40 89.36 1987.50 89.33 1987.60 89.33 1987.70 89.29 1987.80 89.35 1987.90 89.30 1988.00 89.33 1988.10 89.33 1988.20 89.29 1988.30 89.29 1988.40 89.28 1988.50 89.26 1988.60 89.26 1988.70 89.25 1988.80 89.24 1988.90 89.22 1989.00 89.20 1989.10 89.17 1989.20 89.19 1989.30 89.14 1989.40 89.15 1989.50 89.12 1989.60 89.09 1989.70 89.13 1989.80 89.06 1989.90 89.05 1990.00 89.01 1990.10 89.03 1990.20 89.01 1990.30 89.01 1990.40 88.97 1990.50 88.97 1990.60 88.90 1990.70 88.88 1990.80 88.86 1990.90 88.90 1991.00 88.89 1991.10 88.86 1991.20 88.83 1991.30 88.87 1991.40 88.81 1991.50 88.80 1991.60 88.79 1991.70 88.75 1991.80 88.75 1991.90 88.70 1992.00 88.68 1992.10 88.70 1992.20 88.64 1992.30 88.64 1992.40 88.66 1992.50 88.63 1992.60 88.60 1992.70 88.61 1992.80 88.58 1992.90 88.55 1993.00 88.49 1993.10 88.47 1993.20 88.47 1993.30 88.46 1993.40 88.38 1993.50 88.39 1993.60 88.35 1993.70 88.39 1993.80 88.37 1993.90 88.32 1994.00 88.35 1994.10 88.29 1994.20 88.27 1994.30 88.26 1994.40 88.20 1994.50 88.20 1994.60 88.17 1994.70 88.13 1994.80 88.14 1994.90 88.11 1995.00 88.09 1995.10 88.08 1995.20 88.07 1995.30 88.06 1995.40 88.02 1995.50 88.01 1995.60 88.00 1995.70 87.98 1995.80 87.94 1995.90 87.91 1996.00 87.91 1996.10 87.85 1996.20 87.89 1996.30 87.86 1996.40 87.84 1996.50 87.83 1996.60 87.76 1996.70 87.80 1996.80 87.77 1996.90 87.75 1997.00 87.73 1997.10 87.69 1997.20 87.65 1997.30 87.65 1997.40 87.57 1997.50 87.58 1997.60 87.55 1997.70 87.57 1997.80 87.54 1997.90 87.45 1998.00 87.47 1998.10 87.46 1998.20 87.45 1998.30 87.41 1998.40 87.37 1998.50 87.39 1998.60 87.40 1998.70 87.38 1998.80 87.36 1998.90 87.35 1999.00 87.32 1999.10 87.27 1999.20 87.32 1999.30 87.24 1999.40 87.20 1999.50 87.18 1999.60 87.14 1999.70 87.14 1999.80 87.10 1999.90 87.08 2000.00 87.07 2000.10 87.08 2000.20 87.01 2000.30 87.04 2000.40 86.98 2000.50 86.97 2000.60 86.96 2000.70 86.94 2000.80 86.96 2000.90 86.93 2001.00 86.92 2001.10 86.90 2001.20 86.87 2001.30 86.87 2001.40 86.79 2001.50 86.81 2001.60 86.82 2001.70 86.78 2001.80 86.77 2001.90 86.76 2002.00 86.71 2002.10 86.72 2002.20 86.71 2002.30 86.70 2002.40 86.65 2002.50 86.62 2002.60 86.64 2002.70 86.60 2002.80 86.60 2002.90 86.60 2003.00 86.54 2003.10 86.54 2003.20 86.52 2003.30 86.49 2003.40 86.49 2003.50 86.46 2003.60 86.45 2003.70 86.40 2003.80 86.43 2003.90 86.40 2004.00 86.39 2004.10 86.38 2004.20 86.36 2004.30 86.37 2004.40 86.36 2004.50 86.35 2004.60 86.38 2004.70 86.30 2004.80 86.31 2004.90 86.30 2005.00 86.29 2005.10 86.27 2005.20 86.27 2005.30 86.24 2005.40 86.26 2005.50 86.22 2005.60 86.25 2005.70 86.23 2005.80 86.20 2005.90 86.17 2006.00 86.17 2006.10 86.12 2006.20 86.16 2006.30 86.11 2006.40 86.08 2006.50 86.07 2006.60 86.08 2006.70 86.09 2006.80 86.12 2006.90 86.10 2007.00 86.08 2007.10 86.08 2007.20 86.07 2007.30 86.07 2007.40 86.09 2007.50 86.04 2007.60 86.04 2007.70 86.01 2007.80 86.04 2007.90 86.01 2008.00 86.01 2008.10 86.07 2008.20 86.00 2008.30 86.00 2008.40 86.03 2008.50 86.00 2008.60 86.03 2008.70 86.00 2008.80 86.02 2008.90 86.05 2009.00 86.02 2009.10 86.03 2009.20 86.04 2009.30 86.03 2009.40 86.04 2009.50 86.02 2009.60 86.06 2009.70 86.05 2009.80 86.06 2009.90 86.04 2010.00 86.02 2010.10 86.02 2010.20 86.05 2010.30 86.10 2010.40 86.06 2010.50 86.08 2010.60 86.07 2010.70 86.09 2010.80 86.11 2010.90 86.11 2011.00 86.13 2011.10 86.12 2011.20 86.12 2011.30 86.18 2011.40 86.16 2011.50 86.16 2011.60 86.20 2011.70 86.20 2011.80 86.22 2011.90 86.25 2012.00 86.21 2012.10 86.26 2012.20 86.22 2012.30 86.21 2012.40 86.24 2012.50 86.25 2012.60 86.30 2012.70 86.33 2012.80 86.29 2012.90 86.36 2013.00 86.37 2013.10 86.41 2013.20 86.43 2013.30 86.43 2013.40 86.43 2013.50 86.45 2013.60 86.44 2013.70 86.45 2013.80 86.50 2013.90 86.50 2014.00 86.50 2014.10 86.53 2014.20 86.58 2014.30 86.59 2014.40 86.64 2014.50 86.63 2014.60 86.68 2014.70 86.69 2014.80 86.73 2014.90 86.76 2015.00 86.75 2015.10 86.76 2015.20 86.81 2015.30 86.79 2015.40 86.85 2015.50 86.89 2015.60 86.88 2015.70 86.94 2015.80 86.90 2015.90 86.99 2016.00 86.98 2016.10 87.01 2016.20 87.05 2016.30 87.09 2016.40 87.09 2016.50 87.16 2016.60 87.18 2016.70 87.20 2016.80 87.25 2016.90 87.27 2017.00 87.30 2017.10 87.33 2017.20 87.39 2017.30 87.38 2017.40 87.40 2017.50 87.41 2017.60 87.46 2017.70 87.50 2017.80 87.50 2017.90 87.52 2018.00 87.58 2018.10 87.54 2018.20 87.63 2018.30 87.63 2018.40 87.67 2018.50 87.72 2018.60 87.72 2018.70 87.77 2018.80 87.82 2018.90 87.82 2019.00 87.89 2019.10 87.92 2019.20 87.93 2019.30 87.94 2019.40 87.97 2019.50 88.03 2019.60 88.01 2019.70 88.05 2019.80 88.08 2019.90 88.11 2020.00 88.18 2020.10 88.17 2020.20 88.19 2020.30 88.24 2020.40 88.25 2020.50 88.26 2020.60 88.33 2020.70 88.30 2020.80 88.37 2020.90 88.34 2021.00 88.35 2021.10 88.42 2021.20 88.44 2021.30 88.48 2021.40 88.50 2021.50 88.52 2021.60 88.58 2021.70 88.54 2021.80 88.59 2021.90 88.61 2022.00 88.64 2022.10 88.63 2022.20 88.66 2022.30 88.68 2022.40 88.71 2022.50 88.73 2022.60 88.72 2022.70 88.78 2022.80 88.76 2022.90 88.78 2023.00 88.84 2023.10 88.84 2023.20 88.83 2023.30 88.86 2023.40 88.85 2023.50 88.94 2023.60 88.91 2023.70 88.93 2023.80 88.91 2023.90 88.93 2024.00 88.90 2024.10 88.94 2024.20 88.94 2024.30 88.95 2024.40 89.00 2024.50 88.96 2024.60 89.03 2024.70 88.97 2024.80 88.98 2024.90 88.96 2025.00 88.98 2025.10 88.97 2025.20 88.98 2025.30 88.91 2025.40 88.97 2025.50 88.93 2025.60 88.90 2025.70 88.91 2025.80 88.92 2025.90 88.93 2026.00 88.93 2026.10 88.90 2026.20 88.91 2026.30 88.87 2026.40 88.89 2026.50 88.87 2026.60 88.83 2026.70 88.84 2026.80 88.80 2026.90 88.78 2027.00 88.76 2027.10 88.74 2027.20 88.70 2027.30 88.74 2027.40 88.66 2027.50 88.69 2027.60 88.62 2027.70 88.60 2027.80 88.58 2027.90 88.53 2028.00 88.48 2028.10 88.49 2028.20 88.40 2028.30 88.43 2028.40 88.35 2028.50 88.35 2028.60 88.29 2028.70 88.28 2028.80 88.21 2028.90 88.22 2029.00 88.17 2029.10 88.09 2029.20 88.08 2029.30 88.01 2029.40 87.99 2029.50 87.97 2029.60 87.91 2029.70 87.90 2029.80 87.84 2029.90 87.79 2030.00 87.78 2030.10 87.69 2030.20 87.64 2030.30 87.58 2030.40 87.52 2030.50 87.48 2030.60 87.42 2030.70 87.33 2030.80 87.34 2030.90 87.28 2031.00 87.20 2031.10 87.19 2031.20 87.13 2031.30 87.05 2031.40 87.06 2031.50 86.92 2031.60 86.92 2031.70 86.82 2031.80 86.79 2031.90 86.73 2032.00 86.67 2032.10 86.58 2032.20 86.54 2032.30 86.47 2032.40 86.41 2032.50 86.34 2032.60 86.30 2032.70 86.24 2032.80 86.17 2032.90 86.08 2033.00 86.08 2033.10 85.98 2033.20 85.96 2033.30 85.92 2033.40 85.80 2033.50 85.78 2033.60 85.70 2033.70 85.64 2033.80 85.58 2033.90 85.53 2034.00 85.47 2034.10 85.39 2034.20 85.36 2034.30 85.29 2034.40 85.24 2034.50 85.14 2034.60 85.11 2034.70 85.03 2034.80 84.99 2034.90 84.92 2035.00 84.85 2035.10 84.79 2035.20 84.71 2035.30 84.67 2035.40 84.66 2035.50 84.57 2035.60 84.55 2035.70 84.53 2035.80 84.46 2035.90 84.46 2036.00 84.36 2036.10 84.33 2036.20 84.27 2036.30 84.20 2036.40 84.18 2036.50 84.15 2036.60 84.08 2036.70 84.03 2036.80 83.97 2036.90 83.96 2037.00 83.94 2037.10 83.90 2037.20 83.84 2037.30 83.84 2037.40 83.79 2037.50 83.76 2037.60 83.70 2037.70 83.69 2037.80 83.67 2037.90 83.66 2038.00 83.61 2038.10 83.63 2038.20 83.60 2038.30 83.59 2038.40 83.57 2038.50 83.51 2038.60 83.51 2038.70 83.50 2038.80 83.47 2038.90 83.47 2039.00 83.47 2039.10 83.41 2039.20 83.39 2039.30 83.43 2039.40 83.42 2039.50 83.43 2039.60 83.41 2039.70 83.41 2039.80 83.43 2039.90 83.41 2040.00 83.45 2040.10 83.45 2040.20 83.46 2040.30 83.49 2040.40 83.48 2040.50 83.52 2040.60 83.52 2040.70 83.52 2040.80 83.53 2040.90 83.55 2041.00 83.57 2041.10 83.62 2041.20 83.61 2041.30 83.67 2041.40 83.67 2041.50 83.70 2041.60 83.76 2041.70 83.78 2041.80 83.83 2041.90 83.87 2042.00 83.95 2042.10 83.90 2042.20 84.00 2042.30 84.04 2042.40 84.07 2042.50 84.10 2042.60 84.12 2042.70 84.18 2042.80 84.24 2042.90 84.28 2043.00 84.32 2043.10 84.37 2043.20 84.39 2043.30 84.44 2043.40 84.48 2043.50 84.54 2043.60 84.53 2043.70 84.61 2043.80 84.66 2043.90 84.72 2044.00 84.73 2044.10 84.78 2044.20 84.89 2044.30 84.94 2044.40 84.91 2044.50 85.01 2044.60 85.06 2044.70 85.07 2044.80 85.08 2044.90 85.09 2045.00 85.10 2045.10 85.10 2045.20 85.12 2045.30 85.15 2045.40 85.18 2045.50 85.17 2045.60 85.17 2045.70 85.19 2045.80 85.21 2045.90 85.18 2046.00 85.17 2046.10 85.13 2046.20 85.15 2046.30 85.11 2046.40 85.09 2046.50 85.07 2046.60 85.01 2046.70 84.96 2046.80 84.88 2046.90 84.80 2047.00 84.77 2047.10 84.65 2047.20 84.55 2047.30 84.47 2047.40 84.32 2047.50 84.21 2047.60 84.10 2047.70 83.93 2047.80 83.80 2047.90 83.62 2048.00 83.43 2048.10 83.27 2048.20 83.09 2048.30 82.90 2048.40 82.73 2048.50 82.47 2048.60 82.25 2048.70 82.02 2048.80 81.76 2048.90 81.48 2049.00 81.16 2049.10 80.84 2049.20 80.58 2049.30 80.20 2049.40 79.82 2049.50 79.49 2049.60 79.11 2049.70 78.69 2049.80 78.31 2049.90 77.89 2050.00 77.46 2050.10 77.07 2050.20 76.60 2050.30 76.14 2050.40 75.69 2050.50 75.24 2050.60 74.73 2050.70 74.18 2050.80 73.63 2050.90 73.10 2051.00 72.64 2051.10 72.00 2051.20 71.34 2051.30 70.80 2051.40 70.15 2051.50 69.54 2051.60 68.86 2051.70 68.24 2051.80 67.64 2051.90 66.96 2052.00 66.26 2052.10 65.68 2052.20 64.94 2052.30 64.31 2052.40 63.54 2052.50 62.78 2052.60 62.12 2052.70 61.45 2052.80 60.65 2052.90 59.84 2053.00 59.18 2053.10 58.34 2053.20 57.65 2053.30 56.81 2053.40 56.07 2053.50 55.36 2053.60 54.60 2053.70 53.83 2053.80 53.04 2053.90 52.28 2054.00 51.54 2054.10 50.72 2054.20 49.88 2054.30 49.23 2054.40 48.44 2054.50 47.66 2054.60 46.83 2054.70 46.13 2054.80 45.33 2054.90 44.59 2055.00 43.78 2055.10 43.00 2055.20 42.32 2055.30 41.59 2055.40 40.86 2055.50 40.08 2055.60 39.39 2055.70 38.73 2055.80 37.99 2055.90 37.23 2056.00 36.61 2056.10 35.89 2056.20 35.20 2056.30 34.50 2056.40 33.85 2056.50 33.17 2056.60 32.54 2056.70 31.87 2056.80 31.15 2056.90 30.63 2057.00 30.01 2057.10 29.43 2057.20 28.77 2057.30 28.24 2057.40 27.68 2057.50 27.11 2057.60 26.54 2057.70 25.98 2057.80 25.43 2057.90 24.85 2058.00 24.38 2058.10 23.81 2058.20 23.30 2058.30 22.81 2058.40 22.31 2058.50 21.74 2058.60 21.37 2058.70 20.88 2058.80 20.50 2058.90 20.02 2059.00 19.57 2059.10 19.18 2059.20 18.78 2059.30 18.36 2059.40 17.91 2059.50 17.55 2059.60 17.16 2059.70 16.80 2059.80 16.37 2059.90 16.02 2060.00 15.68 2060.10 15.34 2060.20 14.94 2060.30 14.63 2060.40 14.33 2060.50 14.00 2060.60 13.72 2060.70 13.38 2060.80 13.14 2060.90 12.85 2061.00 12.56 2061.10 12.26 2061.20 12.00 2061.30 11.74 2061.40 11.49 2061.50 11.22 2061.60 10.98 2061.70 10.72 2061.80 10.51 2061.90 10.25 2062.00 10.01 2062.10 9.83 2062.20 9.60 2062.30 9.40 2062.40 9.17 2062.50 9.00 2062.60 8.80 2062.70 8.60 2062.80 8.42 2062.90 8.25 2063.00 8.06 2063.10 7.90 2063.20 7.74 2063.30 7.55 2063.40 7.39 2063.50 7.23 2063.60 7.08 2063.70 6.90 2063.80 6.77 2063.90 6.64 2064.00 6.49 2064.10 6.34 2064.20 6.22 2064.30 6.09 2064.40 5.96 2064.50 5.84 2064.60 5.71 2064.70 5.59 2064.80 5.48 2064.90 5.37 2065.00 5.24 2065.10 5.14 2065.20 5.03 2065.30 4.93 2065.40 4.82 2065.50 4.72 2065.60 4.63 2065.70 4.54 2065.80 4.44 2065.90 4.35 2066.00 4.27 2066.10 4.18 2066.20 4.09 2066.30 4.00 2066.40 3.93 2066.50 3.86 2066.60 3.77 2066.70 3.69 2066.80 3.63 2066.90 3.55 2067.00 3.47 2067.10 3.40 2067.20 3.34 2067.30 3.28 2067.40 3.21 2067.50 3.14 2067.60 3.09 2067.70 3.03 2067.80 2.97 2067.90 2.92 2068.00 2.85 2068.10 2.80 2068.20 2.75 2068.30 2.70 2068.40 2.64 2068.50 2.59 2068.60 2.54 2068.70 2.49 2068.80 2.44 2068.90 2.39 2069.00 2.35 2069.10 2.31 2069.20 2.27 2069.30 2.22 2069.40 2.19 2069.50 2.14 2069.60 2.11 2069.70 2.07 2069.80 2.02 2069.90 1.99 2070.00 1.96 2070.10 1.91 2070.20 1.88 2070.30 1.85 2070.40 1.81 2070.50 1.78 2070.60 1.74 2070.70 1.71 2070.80 1.68 2070.90 1.66 2071.00 1.62 2071.10 1.59 2071.20 1.56 2071.30 1.54 2071.40 1.51 2071.50 1.48 2071.60 1.46 2071.70 1.43 2071.80 1.42 2071.90 1.38 2072.00 1.35 2072.10 1.33 2072.20 1.31 2072.30 1.28 2072.40 1.26 2072.50 1.24 2072.60 1.22 2072.70 1.20 2072.80 1.18 2072.90 1.16 2073.00 1.14 2073.10 1.12 2073.20 1.11 2073.30 1.08 2073.40 1.06 2073.50 1.05 2073.60 1.03 2073.70 1.02 2073.80 0.99 2073.90 0.98 2074.00 0.96 2074.10 0.94 2074.20 0.93 2074.30 0.91 2074.40 0.90 2074.50 0.88 2074.60 0.87 2074.70 0.86 2074.80 0.84 2074.90 0.82 2075.00 0.81 2075.10 0.80 2075.20 0.79 2075.30 0.77 2075.40 0.76 2075.50 0.75 2075.60 0.74 2075.70 0.72 2075.80 0.71 2075.90 0.70 2076.00 0.69 2076.10 0.68 2076.20 0.67 2076.30 0.66 2076.40 0.65 2076.50 0.64 2076.60 0.62 2076.70 0.62 2076.80 0.61 2076.90 0.60 2077.00 0.59 2077.10 0.58 2077.20 0.57 2077.30 0.56 2077.40 0.55 2077.50 0.55 2077.60 0.54 2077.70 0.53 2077.80 0.53 2077.90 0.52 2078.00 0.51 2078.10 0.50 2078.20 0.50 2078.30 0.49 2078.40 0.47 2078.50 0.47 2078.60 0.46 2078.70 0.45 2078.80 0.45 2078.90 0.44 2079.00 0.44 2079.10 0.43 2079.20 0.42 2079.30 0.41 2079.40 0.41 2079.50 0.41 2079.60 0.40 2079.70 0.39 2079.80 0.38 2079.90 0.38 2080.00 0.37 2080.10 0.37 2080.20 0.36 2080.30 0.36 2080.40 0.35 2080.50 0.35 2080.60 0.35 2080.70 0.34 2080.80 0.33 2080.90 0.33 2081.00 0.32 2081.10 0.32 2081.20 0.32 2081.30 0.31 2081.40 0.30 2081.50 0.30 2081.60 0.30 2081.70 0.30 2081.80 0.29 2081.90 0.28 2082.00 0.29 2082.10 0.28 2082.20 0.27 2082.30 0.27 2082.40 0.27 2082.50 0.26 2082.60 0.27 2082.70 0.26 2082.80 0.24 2082.90 0.25 2083.00 0.25 2083.10 0.24 2083.20 0.24 2083.30 0.24 2083.40 0.23 2083.50 0.23 2083.60 0.23 2083.70 0.22 2083.80 0.22 2083.90 0.22 2084.00 0.22 2084.10 0.21 2084.20 0.21 2084.30 0.21 2084.40 0.21 2084.50 0.20 2084.60 0.20 2084.70 0.19 2084.80 0.19 2084.90 0.19 2085.00 0.19 2085.10 0.19 2085.20 0.18 2085.30 0.18 2085.40 0.18 2085.50 0.18 2085.60 0.18 2085.70 0.17 2085.80 0.18 2085.90 0.17 2086.00 0.17 2086.10 0.17 2086.20 0.16 2086.30 0.16 2086.40 0.16 2086.50 0.16 2086.60 0.15 2086.70 0.15 2086.80 0.15 2086.90 0.15 2087.00 0.15 2087.10 0.15 2087.20 0.14 2087.30 0.15 2087.40 0.14 2087.50 0.14 2087.60 0.14 2087.70 0.14 2087.80 0.14 2087.90 0.13 2088.00 0.13 2088.10 0.13 2088.20 0.13 2088.30 0.12 2088.40 0.12 2088.50 0.13 2088.60 0.12 2088.70 0.12 2088.80 0.12 2088.90 0.12 2089.00 0.12 2089.10 0.11 2089.20 0.11 2089.30 0.11 2089.40 0.10 2089.50 0.11 2089.60 0.11 2089.70 0.10 2089.80 0.10 2089.90 0.10 2090.00 0.10 2090.10 0.10 2090.20 0.10 2090.30 0.10 2090.40 0.10 2090.50 0.10 2090.60 0.09 2090.70 0.09 2090.80 0.09 2090.90 0.09 2091.00 0.09 2091.10 0.09 2091.20 0.09 2091.30 0.09 2091.40 0.09 2091.50 0.09 2091.60 0.08 2091.70 0.09 2091.80 0.08 2091.90 0.09 2092.00 0.08 2092.10 0.08 2092.20 0.08 2092.30 0.09 2092.40 0.08 2092.50 0.08 2092.60 0.07 2092.70 0.08 2092.80 0.07 2092.90 0.08 2093.00 0.08 2093.10 0.07 2093.20 0.07 2093.30 0.07 2093.40 0.07 2093.50 0.07 2093.60 0.07 2093.70 0.07 2093.80 0.07 2093.90 0.07 2094.00 0.07 2094.10 0.07 2094.20 0.06 2094.30 0.07 2094.40 0.06 2094.50 0.06 2094.60 0.06 2094.70 0.07 2094.80 0.06 2094.90 0.06 2095.00 0.06 2095.10 0.05 2095.20 0.05 2095.30 0.06 2095.40 0.06 2095.50 0.06 2095.60 0.05 2095.70 0.05 2095.80 0.06 2095.90 0.06 2096.00 0.05 2096.10 0.06 2096.20 0.05 2096.30 0.05 2096.40 0.05 2096.50 0.05 2096.60 0.05 2096.70 0.05 2096.80 0.05 2096.90 0.05 2097.00 0.06 2097.10 0.04 2097.20 0.05 2097.30 0.05 2097.40 0.05 2097.50 0.04 2097.60 0.04 2097.70 0.04 2097.80 0.05 2097.90 0.05 2098.00 0.04 2098.10 0.04 2098.20 0.04 2098.30 0.04 2098.40 0.04 2098.50 0.04 2098.60 0.04 2098.70 0.04 2098.80 0.04 2098.90 0.04 2099.00 0.04 2099.10 0.03 2099.20 0.03 2099.30 0.03 2099.40 0.04 2099.50 0.04 2099.60 0.03 2099.70 0.04 2099.80 0.04 2099.90 0.04 2100.00 0.04 2100.10 0.03 2100.20 0.03 2100.30 0.03 2100.40 0.03 2100.50 0.03 2100.60 0.03 2100.70 0.03 2100.80 0.03 2100.90 0.04 2101.00 0.03 2101.10 0.04 2101.20 0.04 2101.30 0.03 2101.40 0.03 2101.50 0.03 2101.60 0.03 2101.70 0.03 2101.80 0.03 2101.90 0.04 2102.00 0.02 2102.10 0.03 2102.20 0.02 2102.30 0.03 2102.40 0.03 2102.50 0.03 2102.60 0.02 2102.70 0.03 2102.80 0.02 2102.90 0.03 2103.00 0.03 2103.10 0.03 2103.20 0.03 2103.30 0.02 2103.40 0.03 2103.50 0.02 2103.60 0.03 2103.70 0.02 2103.80 0.03 2103.90 0.03 2104.00 0.03 2104.10 0.02 2104.20 0.02 2104.30 0.03 2104.40 0.02 2104.50 0.02 2104.60 0.02 2104.70 0.02 2104.80 0.02 2104.90 0.02 2105.00 0.02 2105.10 0.02 2105.20 0.02 2105.30 0.02 2105.40 0.02 2105.50 0.03 2105.60 0.02 2105.70 0.02 2105.80 0.02 2105.90 0.02 2106.00 0.02 2106.10 0.02 2106.20 0.02 2106.30 0.02 2106.40 0.02 2106.50 0.02 2106.60 0.02 2106.70 0.02 2106.80 0.02 2106.90 0.02 2107.00 0.02 2107.10 0.02 2107.20 0.02 2107.30 0.02 2107.40 0.02 2107.50 0.02 2107.60 0.02 2107.70 0.02 2107.80 0.01 2107.90 0.02 2108.00 0.02 2108.10 0.02 2108.20 0.01 2108.30 0.02 2108.40 0.01 2108.50 0.01 2108.60 0.01 2108.70 0.01 2108.80 0.02 2108.90 0.02 2109.00 0.02 2109.10 0.02 2109.20 0.02 2109.30 0.01 2109.40 0.01 2109.50 0.02 2109.60 0.01 2109.70 0.02 2109.80 0.01 2109.90 0.01 2110.00 0.01