l(nm) 298K -------------- 1190.00 0.01 1190.20 0.01 1190.40 0.01 1190.60 0.01 1190.80 0.01 1191.00 0.01 1191.20 0.01 1191.40 0.00 1191.60 0.01 1191.80 0.01 1192.00 0.01 1192.20 0.00 1192.40 0.01 1192.60 0.01 1192.80 0.01 1193.00 0.01 1193.20 0.01 1193.40 0.01 1193.60 0.01 1193.80 0.01 1194.00 0.01 1194.20 0.01 1194.40 0.00 1194.60 0.00 1194.80 0.01 1195.00 0.01 1195.20 0.00 1195.40 0.01 1195.60 0.00 1195.80 0.01 1196.00 0.01 1196.20 0.01 1196.40 0.01 1196.60 0.00 1196.80 0.00 1197.00 0.00 1197.20 0.00 1197.40 0.01 1197.60 0.00 1197.80 0.00 1198.00 0.01 1198.20 0.01 1198.40 0.01 1198.60 0.01 1198.80 0.01 1199.00 0.01 1199.20 0.01 1199.40 0.01 1199.60 0.00 1199.80 0.00 1200.00 0.01 1200.20 0.01 1200.40 0.01 1200.60 0.02 1200.80 0.01 1201.00 0.01 1201.20 0.01 1201.40 0.01 1201.60 0.01 1201.80 0.01 1202.00 0.01 1202.20 0.01 1202.40 0.01 1202.60 0.01 1202.80 0.01 1203.00 0.01 1203.20 0.01 1203.40 0.01 1203.60 0.01 1203.80 0.01 1204.00 0.02 1204.20 0.02 1204.40 0.01 1204.60 0.02 1204.80 0.01 1205.00 0.01 1205.20 0.01 1205.40 0.02 1205.60 0.02 1205.80 0.01 1206.00 0.02 1206.20 0.02 1206.40 0.02 1206.60 0.02 1206.80 0.02 1207.00 0.02 1207.20 0.02 1207.40 0.03 1207.60 0.03 1207.80 0.03 1208.00 0.03 1208.20 0.03 1208.40 0.03 1208.60 0.04 1208.80 0.04 1209.00 0.04 1209.20 0.04 1209.40 0.05 1209.60 0.05 1209.80 0.05 1210.00 0.06 1210.20 0.05 1210.40 0.06 1210.60 0.07 1210.80 0.07 1211.00 0.07 1211.20 0.07 1211.40 0.09 1211.60 0.09 1211.80 0.08 1212.00 0.11 1212.20 0.11 1212.40 0.12 1212.60 0.13 1212.80 0.13 1213.00 0.14 1213.20 0.15 1213.40 0.16 1213.60 0.17 1213.80 0.18 1214.00 0.19 1214.20 0.21 1214.40 0.23 1214.60 0.24 1214.80 0.26 1215.00 0.27 1215.20 0.29 1215.40 0.31 1215.60 0.34 1215.80 0.36 1216.00 0.39 1216.20 0.41 1216.40 0.45 1216.60 0.48 1216.80 0.52 1217.00 0.56 1217.20 0.60 1217.40 0.64 1217.60 0.69 1217.80 0.75 1218.00 0.80 1218.20 0.86 1218.40 0.93 1218.60 1.00 1218.80 1.08 1219.00 1.16 1219.20 1.25 1219.40 1.36 1219.60 1.45 1219.80 1.58 1220.00 1.71 1220.20 1.85 1220.40 2.01 1220.60 2.15 1220.80 2.36 1221.00 2.52 1221.20 2.76 1221.40 2.96 1221.60 3.24 1221.80 3.48 1222.00 3.84 1222.20 4.15 1222.40 4.55 1222.60 4.93 1222.80 5.37 1223.00 5.94 1223.20 6.36 1223.40 7.00 1223.60 7.52 1223.80 8.32 1224.00 8.90 1224.20 9.94 1224.40 10.69 1224.60 11.91 1224.80 12.78 1225.00 14.19 1225.20 15.34 1225.40 16.77 1225.60 18.33 1225.80 19.63 1226.00 21.62 1226.20 23.00 1226.40 25.27 1226.60 26.89 1226.80 29.55 1227.00 31.35 1227.20 34.09 1227.40 35.96 1227.60 38.99 1227.80 41.31 1228.00 43.83 1228.20 46.53 1228.40 48.58 1228.60 51.56 1228.80 53.38 1229.00 56.23 1229.20 57.80 1229.40 60.22 1229.60 61.79 1229.80 63.76 1230.00 65.07 1230.20 66.54 1230.40 67.51 1230.60 68.53 1230.80 69.23 1231.00 69.69 1231.20 70.08 1231.40 70.23 1231.60 70.32 1231.80 70.30 1232.00 70.13 1232.20 69.93 1232.40 69.63 1232.60 69.35 1232.80 68.98 1233.00 68.65 1233.20 68.22 1233.40 67.89 1233.60 67.52 1233.80 67.21 1234.00 66.99 1234.20 66.72 1234.40 66.50 1234.60 66.31 1234.80 66.20 1235.00 66.10 1235.20 66.04 1235.40 66.01 1235.60 66.05 1235.80 66.13 1236.00 66.20 1236.20 66.35 1236.40 66.51 1236.60 66.74 1236.80 66.97 1237.00 67.21 1237.20 67.48 1237.40 67.76 1237.60 68.12 1237.80 68.44 1238.00 68.88 1238.20 69.25 1238.40 69.66 1238.60 69.95 1238.80 70.43 1239.00 70.82 1239.20 71.25 1239.40 71.62 1239.60 72.02 1239.80 72.46 1240.00 72.83 1240.20 73.21 1240.40 73.51 1240.60 73.95 1240.80 74.24 1241.00 74.64 1241.20 74.87 1241.40 75.22 1241.60 75.44 1241.80 75.76 1242.00 76.00 1242.20 76.22 1242.40 76.41 1242.60 76.53 1242.80 76.71 1243.00 76.87 1243.20 77.03 1243.40 77.09 1243.60 77.15 1243.80 77.20 1244.00 77.28 1244.20 77.31 1244.40 77.34 1244.60 77.33 1244.80 77.33 1245.00 77.31 1245.20 77.28 1245.40 77.26 1245.60 77.23 1245.80 77.17 1246.00 77.12 1246.20 77.08 1246.40 77.04 1246.60 76.94 1246.80 76.90 1247.00 76.86 1247.20 76.82 1247.40 76.74 1247.60 76.65 1247.80 76.60 1248.00 76.58 1248.20 76.57 1248.40 76.50 1248.60 76.45 1248.80 76.41 1249.00 76.40 1249.20 76.39 1249.40 76.39 1249.60 76.33 1249.80 76.33 1250.00 76.32 1250.20 76.34 1250.40 76.36 1250.60 76.39 1250.80 76.40 1251.00 76.44 1251.20 76.48 1251.40 76.53 1251.60 76.55 1251.80 76.59 1252.00 76.62 1252.20 76.70 1252.40 76.76 1252.60 76.82 1252.80 76.86 1253.00 76.92 1253.20 77.01 1253.40 77.10 1253.60 77.19 1253.80 77.22 1254.00 77.34 1254.20 77.41 1254.40 77.52 1254.60 77.58 1254.80 77.69 1255.00 77.78 1255.20 77.91 1255.40 77.99 1255.60 78.10 1255.80 78.18 1256.00 78.31 1256.20 78.45 1256.40 78.57 1256.60 78.67 1256.80 78.73 1257.00 78.88 1257.20 78.99 1257.40 79.18 1257.60 79.29 1257.80 79.41 1258.00 79.51 1258.20 79.67 1258.40 79.85 1258.60 79.98 1258.80 80.13 1259.00 80.24 1259.20 80.40 1259.40 80.52 1259.60 80.69 1259.80 80.81 1260.00 80.98 1260.20 81.11 1260.40 81.28 1260.60 81.40 1260.80 81.55 1261.00 81.69 1261.20 81.82 1261.40 82.00 1261.60 82.13 1261.80 82.23 1262.00 82.30 1262.20 82.45 1262.40 82.58 1262.60 82.72 1262.80 82.74 1263.00 82.82 1263.20 82.89 1263.40 83.00 1263.60 83.05 1263.80 83.07 1264.00 83.09 1264.20 83.10 1264.40 83.14 1264.60 83.15 1264.80 83.10 1265.00 83.04 1265.20 82.98 1265.40 82.93 1265.60 82.87 1265.80 82.78 1266.00 82.63 1266.20 82.51 1266.40 82.40 1266.60 82.28 1266.80 82.12 1267.00 81.92 1267.20 81.79 1267.40 81.56 1267.60 81.40 1267.80 81.15 1268.00 80.94 1268.20 80.68 1268.40 80.49 1268.60 80.20 1268.80 79.96 1269.00 79.69 1269.20 79.43 1269.40 79.25 1269.60 78.99 1269.80 78.77 1270.00 78.41 1270.20 78.17 1270.40 77.95 1270.60 77.81 1270.80 77.52 1271.00 77.28 1271.20 76.98 1271.40 76.82 1271.60 76.65 1271.80 76.49 1272.00 76.32 1272.20 76.12 1272.40 75.96 1272.60 75.81 1272.80 75.72 1273.00 75.63 1273.20 75.55 1273.40 75.44 1273.60 75.37 1273.80 75.35 1274.00 75.33 1274.20 75.33 1274.40 75.35 1274.60 75.40 1274.80 75.45 1275.00 75.46 1275.20 75.53 1275.40 75.62 1275.60 75.79 1275.80 75.91 1276.00 76.02 1276.20 76.14 1276.40 76.34 1276.60 76.52 1276.80 76.73 1277.00 76.92 1277.20 77.10 1277.40 77.34 1277.60 77.55 1277.80 77.84 1278.00 78.05 1278.20 78.30 1278.40 78.49 1278.60 78.77 1278.80 79.03 1279.00 79.33 1279.20 79.52 1279.40 79.74 1279.60 79.99 1279.80 80.24 1280.00 80.47 1280.20 80.59 1280.40 80.79 1280.60 80.93 1280.80 81.09 1281.00 81.15 1281.20 81.29 1281.40 81.36 1281.60 81.37 1281.80 81.32 1282.00 81.26 1282.20 81.18 1282.40 81.06 1282.60 80.86 1282.80 80.66 1283.00 80.32 1283.20 79.97 1283.40 79.46 1283.60 79.14 1283.80 78.52 1284.00 78.02 1284.20 77.13 1284.40 76.46 1284.60 75.36 1284.80 74.60 1285.00 73.46 1285.20 72.37 1285.40 71.21 1285.60 69.76 1285.80 68.61 1286.00 67.01 1286.20 65.90 1286.40 63.79 1286.60 62.47 1286.80 60.17 1287.00 58.79 1287.20 56.55 1287.40 54.80 1287.60 52.73 1287.80 50.82 1288.00 48.75 1288.20 46.52 1288.40 44.72 1288.60 42.50 1288.80 41.03 1289.00 38.52 1289.20 37.04 1289.40 34.68 1289.60 33.31 1289.80 31.08 1290.00 29.61 1290.20 27.58 1290.40 26.25 1290.60 24.40 1290.80 22.89 1291.00 21.68 1291.20 20.15 1291.40 19.16 1291.60 17.60 1291.80 16.76 1292.00 15.48 1292.20 14.73 1292.40 13.59 1292.60 12.88 1292.80 11.86 1293.00 11.23 1293.20 10.37 1293.40 9.75 1293.60 9.08 1293.80 8.50 1294.00 7.99 1294.20 7.44 1294.40 7.06 1294.60 6.53 1294.80 6.24 1295.00 5.74 1295.20 5.47 1295.40 5.05 1295.60 4.84 1295.80 4.48 1296.00 4.26 1296.20 3.98 1296.40 3.76 1296.60 3.56 1296.80 3.34 1297.00 3.17 1297.20 2.98 1297.40 2.86 1297.60 2.67 1297.80 2.56 1298.00 2.40 1298.20 2.31 1298.40 2.17 1298.60 2.06 1298.80 1.94 1299.00 1.86 1299.20 1.78 1299.40 1.68 1299.60 1.61 1299.80 1.53 1300.00 1.47 1300.20 1.39 1300.40 1.35 1300.60 1.26 1300.80 1.23 1301.00 1.16 1301.20 1.12 1301.40 1.06 1301.60 1.01 1301.80 0.98 1302.00 0.93 1302.20 0.90 1302.40 0.86 1302.60 0.83 1302.80 0.79 1303.00 0.77 1303.20 0.73 1303.40 0.71 1303.60 0.67 1303.80 0.65 1304.00 0.62 1304.20 0.60 1304.40 0.58 1304.60 0.54 1304.80 0.54 1305.00 0.50 1305.20 0.50 1305.40 0.47 1305.60 0.46 1305.80 0.43 1306.00 0.42 1306.20 0.40 1306.40 0.39 1306.60 0.37 1306.80 0.36 1307.00 0.34 1307.20 0.33 1307.40 0.31 1307.60 0.30 1307.80 0.29 1308.00 0.28 1308.20 0.27 1308.40 0.25 1308.60 0.24 1308.80 0.23 1309.00 0.22 1309.20 0.21 1309.40 0.21 1309.60 0.20 1309.80 0.19 1310.00 0.17 1310.20 0.17 1310.40 0.16 1310.60 0.15 1310.80 0.14 1311.00 0.14 1311.20 0.13 1311.40 0.12 1311.60 0.12 1311.80 0.12 1312.00 0.11 1312.20 0.10 1312.40 0.10 1312.60 0.09 1312.80 0.09 1313.00 0.08 1313.20 0.08 1313.40 0.07 1313.60 0.07 1313.80 0.07 1314.00 0.06 1314.20 0.06 1314.40 0.05 1314.60 0.06 1314.80 0.05 1315.00 0.05 1315.20 0.05 1315.40 0.05 1315.60 0.04 1315.80 0.04 1316.00 0.03 1316.20 0.04 1316.40 0.04 1316.60 0.04 1316.80 0.03 1317.00 0.03 1317.20 0.03 1317.40 0.03 1317.60 0.02 1317.80 0.03 1318.00 0.03 1318.20 0.02 1318.40 0.03 1318.60 0.02 1318.80 0.03 1319.00 0.02 1319.20 0.02 1319.40 0.02 1319.60 0.02 1319.80 0.02 1320.00 0.01