NIRSPEC Keywords
NIRSPEC Keywords

Keyword Description Type
abort Abort a SPEC exposure integer
abort2 Abort a SCAM exposure integer
all.power.off Turn off Pulizzi power strip integer
argon argon integer
cabtemp0 Cabinet Temperature 0 double
cabtemp1 Cabinet Temperature 1 double
cabtemp10 Cabinet Temperature 10 double
cabtemp11 Cabinet Temperature 11 double
cabtemp2 Cabinet Temperature 2 double
cabtemp3 Cabinet Temperature 3 double
cabtemp4 Cabinet Temperature 4 double
cabtemp5 Cabinet Temperature 5 double
cabtemp6 Cabinet Temperature 6 double
cabtemp7 Cabinet Temperature 7 double
cabtemp8 Cabinet Temperature 8 double
cabtemp9 Cabinet Temperature 9 double
calcabort abort calibration cover movement integer
calcinit move calibration cover to home position integer
calcinitlocset calibration cover current pos. in steps integer
calcinitstat Calibration cover initialization status integer
calcloc read calibration cover current pos. in steps integer
calcpos move calibration cover to named discrete pos. integer
calcstat Calibration cover status string
calcstep move calibration cover in steps integer
calcsw read calibration cover switch status integer
calmabort abort calibration mirror movement integer
calminit move calibration mirror to home position integer
calminitlocset calibration mirror current pos. in steps integer
calminitstat Calibration mirror initialization status integer
calmloc read calibration mirror current pos. steps integer
calmpos move calibration mirror to named discrete pos. integer
calmstat Calibration mirror status string
calmstep move calibration mirror in steps integer
calmsw read calibration mirror switch status integer
calpabort abort calibration pinhole movement integer
calpinit move calibration pinhole to home position integer
calpinitlocset calibration pinhole current pos. in steps integer
calpinitstat Calibration pinhole initialization status integer
calploc read calibration pinhole current pos. in steps integer
calppos move calibration pinhole to named discrete pos. integer
calpstat Calibration pinhole status string
calpstep move calibration pinhole in steps integer
calpsw read calibration pinhole switch status integer
change.detector.temp Change detector temperature setting integer
cid.test CID test integer
coadds Set SPEC coadds integer
coadds2 Set SCAM coadds integer
comment Set SPEC comment line string
comment2 Set SCAM comment line string
cryotemp1 Read cryogenic sensor 1 double
cryotemp10 Read cryogenic sensor 10 double
cryotemp11 Read cryogenic sensor 11 double
cryotemp12 Read cryogenic sensor 12 double
cryotemp13 Read cryogenic sensor 13 double
cryotemp14 Read cryogenic sensor 14 double
cryotemp15 Read cryogenic sensor 15 double
cryotemp16 Read cryogenic sensor 16 double
cryotemp17 Read cryogenic sensor 17 (detector temp 1)double
cryotemp18 Read cryogenic sensor 18 (detector temp 2)double
cryotemp2 Read cryogenic sensor 2 double
cryotemp3 Read cryogenic sensor 3 double
cryotemp4 Read cryogenic sensor 4 double
cryotemp5 Read cryogenic sensor 5 double
cryotemp6 Read cryogenic sensor 6 double
cryotemp7 Read cryogenic sensor 7 double
cryotemp8 Read cryogenic sensor 8 double
cryotemp9 Read cryogenic sensor 9 double
cycle.all.powerCycle Pulizzi power strip integer
dcsheaders Get DCS Headers for FITS files integer
detbias set SPEC detector bias integer
dispabort abort disperser movement integer
dispinit move disperser to home position integer
dispinitlocset disperser current position in steps integer
dispinitstat Cross Disperser initialization status integer
display Display a disk file -> spec quicklook integer
display2 Display a disk file -> scam quicklook integer
disploc read disperser current position in steps integer
dispname FITS file name for spec display string
dispname2 FITS file name for scam display string
disppos move cross disperser to angle (.1 deg) double
dispstat Cross Disperser status string
dispstep move disperser in steps integer
dispsw read disperser switch status integer
dummy A dummy keyword integer
echlabort abort echelle mechanism movement integer
echlinit move echelle mechanism to home position integer
echlinitlocset echelle mechanism current pos. in steps integer
echlinitstat Echelle initialization status integer
echlloc read echelle mechanism current pos. in steps integer
echlpos move echelle to angle in 10ths of degrees double
echlstat Echelle status string
echlstep move echelle mechanism in steps integer
echlsw read echelle mechanism switch status integer
etalon etalon integer
fifo.test.scam SCAM fifo test integer
fifo.test.spec SPEC fifo test integer
fil1abort abort filter 1 wheel movement integer
fil1init move filter wheel 1 to home position integer
fil1initlocset filter wheel 1 current pos. in steps integer
fil1initstat Filter wheel 1 initialization status integer
fil1loc read filter wheel 1 current pos. in steps integer
fil1name Current filter name string
fil1pos move filter wheel 1 to named discrete pos. integer
fil1stat Filter wheel 1 status string
fil1step move filter wheel 1 in steps integer
fil1sw read filter wheel 1 switch status integer
fil2abort abort filter 2 wheel movement integer
fil2init move filter wheel 2 to home position integer
fil2initlocset filter wheel 2 current pos. in steps integer
fil2initstat Filter Wheel 2 initialization status integer
fil2loc read filter wheel 2 current pos. in steps integer
fil2name Current filter name string
fil2pos move filter wheel 2 to named discrete pos. integer
fil2stat Filter wheel 2 status string
fil2step move filter wheel 2 in steps integer
fil2sw read filter wheel 2 switch status integer
filename Set SPEC image file name string
filename2 Set SCAM image file name string
filenum Set SPEC image file running number integer
filenum2 Set SCAM image file running number integer
fileovwr Set SPEC file over-write flag integer
fileovwr2 Set SCAM file over-write flag integer
filesame Alternate filename string
filesame2 Alternate filename string
filname Current filter name string
firstfile Set first file name string
flat flat integer
frameend Specifies when perm. frame is written. integer
frameend2 Specifies when perm. frame is written. integer
framerdy Frame ready signal integer
framerdy2 Frame ready signal integer
freq.scam set SCAM frequency integer
freq.spec set SPEC frequency integer
gain.scam set SCAM gain integer
gain.spec set SPEC gain integer
getcryotemp Toggle cryogenic temperature polling integer
getdetectortemp Read detector temperature integer
go Start a SPEC exposure integer
go2 Start a SCAM exposure integer
irotabort abort image rotator movement integer
irotinit move image rotator to home position integer
irotinitloc set image rotator current pos. in steps integer
irotinitstat Image rotator initialization status integer
irotloc read image rotator current pos. in steps integer
irotpos move image rotator to angle (.1 deg) double
irotstat Image Rotator status string
irotstep move image rotator in steps integer
irotsw read image rotator switch status integer
irottrack Set tracking speed in steps/sec integer
itime Set SPEC exposure time per coadd double
itime2 Set SCAM exposure time per coadd double
killscam Kill the scam quicklook integer
killspec Kill the spec quicklook integer
krypton krypton integer
lampstat Holds lamp status integer
lastfile Set last SPEC image saved to disk string
lastfile2 Set last SCAM image saved to disk string
lsclient Current UI clients connected to server string
maxcab Current Maximum Cabinet Temperature double
maxcabnumb Current Maximum Cabinet Sensor integer
multiscam set number of SCAM multiple reads integer
multispec set number of SPEC multiple reads integer
neon neon integer
noddec nod telescope in DEC in arcsec double
node Nod east double
nodn Nod north double
nodra nod telescope in RA in arcsec double
object Set object name string
observer Set observer's name string
outdir Set SPEC data directory string
outdir2 Set SCAM data directory string
power.off Turn off Pulizzi power strip integer
power.on Turn on Pulizzi power strip integer
q1offsetscamset SCAM quadrant 1 offset integer
q1offsetspecset SPEC quadrant 1 offset integer
q2offsetscamset SCAM quadrant 2 offset integer
q2offsetspecset SPEC quadrant 2 offset integer
q3offsetscamset SCAM quadrant 3 offset integer
q3offsetspecset SPEC quadrant 3 offset integer
q4offsetscamset SCAM quadrant 4 offset integer
q4offsetspecset SPEC quadrant 4 offset integer
rootname Set SPEC image file root name string
rootname2 Set SCAM image file root name string
sampmode Set SPEC sampling_mode integer
sampmode2 Set SCAM sampling mode integer
samprate.scamset SCAM sample rate integer
samprate.specset SPEC sample rate integer
savetest Save current test frame integer
scamguide SCAM_Guiding_Flag integer
scampa scam p.a. double
script Script on/off flag integer
scriptdir Set script directory string
scriptname Set script name string
sensor.read read cabinet temp sensor integer
sensors.getid get cabinet temperature sensor id integer
sensors.reset reset cabinet temperature sensors integer
serial.1a.baud Set baud rate integer
serial.1a.getchar Read a single character integer
serial.1a.handshake Turn on/off CTS/RTS handshaking integer
serial.1a.putchar Write a single character integer
serial.1a.test.string Send out a test string integer
serial.1b.baud Set baud rate integer
serial.1b.getchar Read a single character integer
serial.1b.handshake Turn on/off CTS/RTS handshaking integer
serial.1b.putchar Write a single character integer
serial.1b.test.string Send out a test string integer
serial.2a.baud Set baud rate integer
serial.2a.getchar Read a single character integer
serial.2a.handshake Turn on/off CTS/RTS handshaking integer
serial.2a.putchar Write a single character integer
serial.2a.test.string Send out a test string integer
serial.2b.baud Set baud rate integer
serial.2b.getchar Read a single character integer
serial.2b.handshake Turn on/off CTS/RTS handshaking integer
serial.2b.putchar Write a single character integer
serial.2b.test.string Send out a test string integer
slitabort abort current slit wheel movement integer
slitang slit angle double
slitinit move slit wheel to home position integer
slitinitlocset slit wheel current pos. in steps integer
slitinitstat Slit Wheel initialization status integer
slitloc read slit wheel current pos. in steps integer
slitname Current slit name string
slitpa slit p.a. double
slitpos move slit wheel to a named discrete pos. integer
slitstat Filter wheel 2 status string
slitstep move slit wheel in steps integer
slitsw read slit wheel switch status integer
slitx slit x double
slity slit y double
telescop Set telescope name string
test Start a SPEC test exposure integer
test.frame.scam SCAM test frame integer
test.frame.spec SPEC test frame integer
test2 Start a SCAM test exposure integer
track Image rotator tracking flag integer
tspack CID sent back from transputers integer
tspcid set a command id to send over TSP link integer
tspmsg Param sent back from transputers integer
tspparam set parameter to send over TSP link integer
tspreset Reset TSP Link integer
tspstat Status message sent back from transputers string
tsptrace Set TSP link trace flag integer
tspupdate Request keyword's value from transputers string
undeselectset SPEC undeselect integer
xenon xenon integer


Go to: NIRSPEC Home Page    - Instruments Home Page    - Keck Home Page    - Observer's Reference Shelf

Last modified: 3 August 2000