Background |
Your starlist file contains the list of targets you plan to observe during the night at Keck. The file must conform to certain formatting rules described below in order for the telescope control software to read the file properly. There are additional requirements for Adaptive Optics target lists.
| Formatting Rules for General Target Lists |
| Property | Keyword | Units or Values |
|---|---|---|
| RA proper motion | pmra=s.ssss | seconds-of-time/year |
| Dec proper motion | pmdec=a.aaa | arcsec/year |
| RA differential tracking rate | dra=s.ssss | arcsec/hr divided by 15 (positive implies moving east) |
| Dec differential tracking rate | ddec=a.aaa | arcsec/hr |
| V magnitude | vmag=m.m | mag |
| Rotator mode | rotmode=nnn | pa, vertical, or stationary |
| Rotator position angle | rotdest=mmm.mm | degrees |
| Telescope azimuth wrap | wrap=xxx | shortest, south, or north (south is clockwise with az increasing and north is counterclockwise with az decreasing) |
| RA telescope offset from target RA | raoffset=xx.x | arcseconds (positive implies moving east) |
| Dec telescope offset from target Dec | decoffset=xx.x | arcseconds (positive implies moving north) |
|
Installing Your Starlist file |
In order for the Observing Assistant to locate your starlist file, you must install it in the “starlist directory” on our network. You can access the starlist directory /kroot/starlists from most of our computers (except certain instrument host computers). The convention we suggest is to store your starlist in a subdirectory which is named using the last name of the observing program's PI (e.g., copernicus). If needed, you can create the directory using the command
mkdir -p /kroot/starlists/pinameand then install your starlist using the command
cp starlist /kroot/starlists/pinameYou are free to name your starlist file whatever you want.
|
Sample Starlist File |
# basic objects including only required fields 197+17.1 07 29 09.40 +20 54 45.90 2000.0 ring neb 18 53 36.00 +33 02 00.00 2000.0 # star with proper motion SAO 102961 17 34 24.13 +11 52 28.29 1950.0 pmra=+0.0001 pmdec=-0.007 vmag=9.0 # non-sideral targets Hale-Bopp 5hr 17 30 6.62 -4 41 58.4 APP dra=0.35 ddec=7.3 Titan 6:00UT 01 05 39.60 +04 00 28.846 APP dra=-0.96 ddec=-4.2 # slitmask with specified rotator position Cl0024+16-fld 1 00 24 00.00 +16 00 00.00 2000.0 rotdest=123.45 rotmode=pa # target observed at parallactic angle Herschel101 12 34 56.78 +01 23 45.67 2000.0 rotdest=0.0 rotmode=vertical # science target with nearby offset stars 198xq 13 55 45.78 -25 24 03.3 2000.0 198xq_S1 13 55 46.85 -25 23 46.3 2000.0 raoffset=-14.51 decoffset=-16.99 # 14.51" W, 16.99" S to 198xq 198xq_S2 13 55 48.26 -25 22 10.6 2000.0 raoffset=-33.61 decoffset=-112.72 # 33.61" W, 112.72" S to 198xq 198xq_S3 13 55 39.96 -25 21 50.1 2000.0 raoffset=78.83 decoffset=-133.21 # 78.83" E, 133.21" S to 198xq
|
Formatting Target Lists for AO Observations |
Further requirements exist for target lists for Laser and Natural Guidestar Adaptive Optics observations. Please see the Laser Guide Star Adaptive optics page and especially the Formatting AO Target Lists description for further details.