3499.33 0.004320815 3500.56 -0.02006961 3501.80 0.01040739 3503.03 0.005483272 3504.27 0.01770263 3505.50 -0.02218666 3506.74 -0.006753159 3507.97 0.02006526 3509.21 -0.01149879 3510.44 -0.001656034 3511.68 0.003003666 3512.91 0.03076122 3514.15 0.01700581 3515.39 -0.00321874 3516.62 0.01140917 3517.86 -0.02584392 3519.09 -0.01639544 3520.33 -0.004168995 3521.56 0.01338397 3522.80 0.03057079 3524.03 0.03764246 3525.27 0.002612857 3526.50 -0.02087951 3527.74 -0.007465416 3528.97 -0.006655644 3530.21 -0.007400742 3531.44 -0.02413714 3532.68 -0.02233423 3533.91 0.001858486 3535.15 0.002612363 3536.38 -0.01393736 3537.62 -0.003635841 3538.85 0.008391606 3540.09 -0.00301156 3541.32 -0.003598125 3542.56 0.01391226 3543.79 -0.006153089 3545.03 0.006347698 3546.26 0.016565 3547.50 0.01296141 3548.73 -0.006191371 3549.97 -0.01041489 3551.20 -0.003142772 3552.44 0.01772471 3553.67 0.03626703 3554.91 0.005339268 3556.14 -7.459320E-4 3557.38 0.01383494 3558.61 3.415667E-4 3559.85 -0.005691323 3561.08 0.03212978 3562.32 0.04294305 3563.55 -0.02735035 3564.79 -9.043390E-4 3566.02 0.02833616 3567.26 0.02112891 3568.50 0.03231453 3569.73 0.01223889 3570.97 -0.02091314 3572.20 -0.006053039 3573.44 -0.0191639 3574.67 -0.01245386 3575.91 0.008539721 3577.14 0.04137272 3578.38 0.0170982 3579.61 0.009511147 3580.85 0.04282883 3582.08 0.001545149 3583.32 0.006031121 3584.55 0.01984124 3585.79 -0.002258031 3587.02 -0.003683784 3588.26 0.03009242 3589.49 0.02850553 3590.73 0.02661916 3591.96 0.01879453 3593.20 0.005775416 3594.43 -0.01180773 3595.67 0.01717702 3596.90 0.01154576 3598.14 0.02112345 3599.37 0.009765027 3600.61 0.02191786 3601.84 0.03777062 3603.08 0.01292677 3604.31 0.03149866 3605.55 0.02545763 3606.78 0.02282904 3608.02 0.06031462 3609.25 0.0289765 3610.49 0.007791713 3611.72 0.02305122 3612.96 0.003307522 3614.19 0.02156487 3615.43 0.03827186 3616.66 0.03421374 3617.90 0.01666813 3619.13 0.02954399 3620.37 0.02482855 3621.60 0.004377338 3622.84 0.04899045 3624.08 0.05357433 3625.31 0.004055454 3626.55 0.03219514 3627.78 0.05435859 3629.02 0.01011558 3630.25 -0.001601428 3631.49 0.01538638 3632.72 0.005540742 3633.96 0.03317346 3635.19 0.04077591 3636.43 0.03855579 3637.66 0.04941104 3638.90 0.06750102 3640.13 0.04537826 3641.37 0.06572076 3642.60 0.03166633 3643.84 0.04625155 3645.07 0.04217118 3646.31 0.02616547 3647.54 0.04168645 3648.78 0.03859488 3650.01 0.02206098 3651.25 0.02615199 3652.48 0.0247843 3653.72 0.02995159 3654.95 0.01387505 3656.19 0.0280136 3657.42 0.0536107 3658.66 0.04797271 3659.89 0.05059126 3661.13 0.02098326 3662.36 0.01536069 3663.60 0.01574229 3664.83 0.03612873 3666.07 0.05192427 3667.30 0.04909359 3668.54 0.06137044 3669.77 0.05720616 3671.01 0.0409403 3672.24 0.04497086 3673.48 0.05763544 3674.71 0.03954308 3675.95 0.07385881 3677.19 0.07026266 3678.42 0.0649868 3679.66 0.06094104 3680.89 0.04407386 3682.13 0.07809362 3683.36 0.0783776 3684.60 0.05635157 3685.83 0.04354931 3687.07 0.05863282 3688.30 0.051358 3689.54 0.06266273 3690.77 0.05204035 3692.01 0.05636706 3693.24 0.08590298 3694.48 0.08236873 3695.71 0.04747469 3696.95 0.04660904 3698.18 0.05752213 3699.42 0.05637979 3700.65 0.07270259 3701.89 0.07188236 3703.12 0.06774161 3704.36 0.06551377 3705.59 0.06106151 3706.83 0.06825934 3708.06 0.06671471 3709.30 0.06754742 3710.53 0.07274254 3711.77 0.0651923 3713.00 0.04868528 3714.24 0.0469338 3715.47 0.08125395 3716.71 0.07700811 3717.94 0.07301904 3719.18 0.07030132 3720.41 0.0559084 3721.65 0.08853985 3722.88 0.08947616 3724.12 0.07774962 3725.35 0.06415913 3726.59 0.05413929 3727.82 0.06539563 3729.06 0.07568602 3730.30 0.07654018 3731.53 0.06720396 3732.77 0.06020489 3734.00 0.04391581 3735.24 0.0446349 3736.47 0.08456949 3737.71 0.06426853 3738.94 0.04997944 3740.18 0.06098844 3741.41 0.06780484 3742.65 0.07638758 3743.88 0.06968291 3745.12 0.07680951 3746.35 0.08466434 3747.59 0.06973772 3748.82 0.06663422 3750.06 0.08605397 3751.29 0.06531991 3752.53 0.04832492 3753.76 0.07204573 3755.00 0.09585006 3756.23 0.07069191 3757.47 0.05600004 3758.70 0.08297201 3759.94 0.08195364 3761.17 0.07342792 3762.41 0.07287246 3763.64 0.09605372 3764.88 0.1018493 3766.11 0.07413105 3767.35 0.07659864 3768.58 0.08808146 3769.82 0.07857911 3771.05 0.07590016 3772.29 0.06514376 3773.52 0.08214182 3774.76 0.110576 3775.99 0.09190105 3777.23 0.1006644 3778.46 0.09160759 3779.70 0.09380309 3780.93 0.102747 3782.17 0.08475246 3783.41 0.1128199 3784.64 0.1093921 3785.88 0.0877095 3787.11 0.106022 3788.35 0.0892513 3789.58 0.107523 3790.82 0.10853 3792.05 0.1065655 3793.29 0.1439498 3794.52 0.1237736 3795.76 0.1272997 3796.99 0.127297 3798.23 0.1426808 3799.46 0.1115721 3800.70 0.1259854 3801.93 0.1268397 3803.17 0.1454808 3804.40 0.1607473 3805.64 0.1451824 3806.87 0.1470841 3808.11 0.1662042 3809.34 0.1677964 3810.58 0.1830268 3811.81 0.1880167 3813.05 0.1868905 3814.28 0.2114509 3815.52 0.2379006 3816.75 0.2278126 3817.99 0.2341783 3819.22 0.2598467 3820.46 0.2848302 3821.69 0.2933113 3822.93 0.2917961 3824.16 0.3110323 3825.40 0.3100155 3826.63 0.3367032 3827.87 0.3417153 3829.10 0.3747374 3830.34 0.3870347 3831.57 0.3971555 3832.81 0.3988933 3834.04 0.4166929 3835.28 0.4349334 3836.51 0.4368316 3837.75 0.4481803 3838.99 0.4832087 3840.22 0.4868654 3841.46 0.4672875 3842.69 0.4700566 3843.93 0.4738215 3845.16 0.4820015 3846.40 0.5047738 3847.63 0.492359 3848.87 0.4957722 3850.10 0.5005597 3851.34 0.5127211 3852.57 0.5053988 3853.81 0.5128192 3855.04 0.5328914 3856.28 0.5322822 3857.51 0.5310292 3858.75 0.5311731 3859.98 0.5385057 3861.22 0.5575026 3862.45 0.5427793 3863.69 0.5475749 3864.92 0.5505716 3866.16 0.5390353 3867.39 0.5564585 3868.63 0.5709711 3869.86 0.5724722 3871.10 0.5729991 3872.33 0.5709689 3873.57 0.5591763 3874.80 0.5696579 3876.04 0.5851355 3877.27 0.5803245 3878.51 0.5856978 3879.74 0.5918297 3880.98 0.6000268 3882.21 0.6047552 3883.45 0.6043996 3884.68 0.6092082 3885.92 0.6167476 3887.15 0.6267479 3888.39 0.6180564 3889.62 0.6159637 3890.86 0.625795 3892.10 0.627255 3893.33 0.6380497 3894.57 0.6351094 3895.80 0.6290857 3897.04 0.6330975 3898.27 0.6415966 3899.51 0.6558142 3900.74 0.6484719 3901.98 0.6636761 3903.21 0.6531706 3904.45 0.6478189 3905.68 0.6543984 3906.92 0.6530998 3908.15 0.6618367 3909.39 0.6706494 3910.62 0.6735398 3911.86 0.6751881 3913.09 0.6761149 3914.33 0.6786237 3915.56 0.684278 3916.80 0.6839861 3918.03 0.6794775 3919.27 0.6786748 3920.50 0.6842543 3921.74 0.6862481 3922.97 0.6927126 3924.21 0.6973252 3925.44 0.6918334 3926.68 0.6930043 3927.91 0.6942985 3929.15 0.6983216 3930.38 0.7040152 3931.62 0.7073078 3932.85 0.7024488 3934.09 0.7081119 3935.32 0.7119935 3936.56 0.70474 3937.79 0.7095847 3939.03 0.7131916 3940.26 0.7116376 3941.50 0.7121244 3942.73 0.7116888 3943.97 0.7176352 3945.21 0.7126087 3946.44 0.718012 3947.68 0.7202034 3948.91 0.7168965 3950.15 0.7156875 3951.38 0.7183083 3952.62 0.7266006 3953.85 0.726809 3955.09 0.7229204 3956.32 0.7220503 3957.56 0.7267767 3958.79 0.7296082 3960.03 0.7343086 3961.26 0.7337107 3962.50 0.7320707 3963.73 0.7299679 3964.97 0.7315313 3966.20 0.7322267 3967.44 0.7342721 3968.67 0.7406851 3969.91 0.7362173 3971.14 0.7336672 3972.38 0.735562 3973.61 0.7402186 3974.85 0.7404251 3976.08 0.740077 3977.32 0.7343274 3978.55 0.7398455 3979.79 0.740375 3981.02 0.7419149 3982.26 0.7426792 3983.49 0.7442206 3984.73 0.7415949 3985.96 0.7417536 3987.20 0.7489009 3988.43 0.7499387 3989.67 0.745192 3990.90 0.7459947 3992.14 0.7463846 3993.37 0.7438003 3994.61 0.7475834 3995.84 0.7464348 3997.08 0.7470369 3998.31 0.7458563 3999.55 0.7481529 4000.79 0.7494412 4002.02 0.7491535 4003.26 0.7508737 4004.49 0.7513709 4005.73 0.7489343 4006.96 0.7495125 4008.20 0.7525914 4009.43 0.7497603 4010.67 0.7486286 4011.90 0.7518179 4013.14 0.7514789 4014.37 0.7532512 4015.61 0.7500319 4016.84 0.7545245 4018.08 0.7568081 4019.31 0.755233 4020.55 0.7526076 4021.78 0.7539375 4023.02 0.7547477 4024.25 0.7556913 4025.49 0.7554151 4026.72 0.7582306 4027.96 0.7573523 4029.19 0.755703 4030.43 0.7579281 4031.66 0.7569587 4032.90 0.7543007 4034.13 0.756144 4035.37 0.7538338 4036.60 0.7542704 4037.84 0.7557025 4039.07 0.755379 4040.31 0.7557143 4041.54 0.753913 4042.78 0.7545251 4044.01 0.7529617 4045.25 0.7506303 4046.48 0.7507548 4047.72 0.751858 4048.95 0.7507881 4050.19 0.7488582 4051.42 0.7463747 4052.66 0.7473116 4053.90 0.7473495 4055.13 0.7472094 4056.37 0.7453107 4057.60 0.7434699 4058.84 0.7431521 4060.07 0.7438077 4061.31 0.7422254 4062.54 0.7406142 4063.78 0.7418248 4065.01 0.7418109 4066.25 0.7428917 4067.48 0.7397806 4068.72 0.739752 4069.95 0.7395841 4071.19 0.7393489 4072.42 0.7375503 4073.66 0.7378174 4074.89 0.7375262 4076.13 0.7360881 4077.36 0.7391602 4078.60 0.7399063 4079.83 0.7356407 4081.07 0.7355592 4082.30 0.7355307 4083.54 0.7354861 4084.77 0.7332026 4086.01 0.7328118 4087.24 0.7330093 4088.48 0.7318313 4089.71 0.7309402 4090.95 0.7317148 4092.18 0.7311836 4093.42 0.72968 4094.65 0.7283329 4095.89 0.7293622 4097.12 0.7286059 4098.36 0.7264324 4099.59 0.7265369 4100.83 0.7258033 4102.06 0.7237309 4103.30 0.7230694 4104.53 0.7234749 4105.77 0.7222065 4107.01 0.7226278 4108.24 0.7221921 4109.48 0.7207139 4110.71 0.7190601 4111.95 0.7177725 4113.18 0.7171294 4114.42 0.7173381 4115.65 0.7165568 4116.89 0.7149785 4118.12 0.7151541 4119.36 0.7149827 4120.59 0.7120175 4121.83 0.7098789 4123.06 0.7100896 4124.30 0.7089934 4125.53 0.7069885 4126.77 0.7047484 4128.00 0.7013206 4129.24 0.6991997 4130.47 0.6972496 4131.71 0.6945769 4132.94 0.6910409 4134.18 0.6868904 4135.41 0.681522 4136.65 0.6766194 4137.88 0.6706986 4139.12 0.6655626 4140.35 0.6608616 4141.59 0.6538357 4142.82 0.6456146 4144.06 0.6380008 4145.29 0.6295567 4146.53 0.6216771 4147.76 0.6137379 4149.00 0.603596 4150.23 0.5950364 4151.47 0.5868981 4152.70 0.5764444 4153.94 0.5655681 4155.17 0.5546196 4156.41 0.5444459 4157.64 0.5331297 4158.88 0.5214399 4160.11 0.5101585 4161.35 0.4983792 4162.59 0.4863405 4163.82 0.4735642 4165.06 0.4612652 4166.29 0.4472916 4167.53 0.4338007 4168.76 0.4212045 4170.00 0.4068252 4171.23 0.3907177 4172.47 0.3762065 4173.70 0.3609719 4174.94 0.3441674 4176.17 0.326653 4177.41 0.3100809 4178.64 0.2926489 4179.88 0.2743147 4181.11 0.2570536 4182.35 0.2400269 4183.58 0.2213305 4184.82 0.2036373 4186.05 0.1867822 4187.29 0.1713695 4188.52 0.1561984 4189.76 0.1415765 4190.99 0.1281863 4192.23 0.1153726 4193.46 0.1038517 4194.70 0.09444075 4195.93 0.08455818 4197.17 0.07652082 4198.40 0.06784171 4199.64 0.06100762 4200.87 0.05595793 4202.11 0.05021787 4203.34 0.04523409 4204.58 0.04093292 4205.81 0.03876752 4207.05 0.03484818 4208.28 0.03205163 4209.52 0.02808239 4210.75 0.01742187 4211.99 0.02320777 4213.22 0.02330182 4214.46 0.02214889 4215.70 0.01891995 4216.93 0.01776543 4218.17 0.01769786 4219.40 0.0154943 4220.64 0.01440681 4221.87 0.01385415 4223.11 0.01294737 4224.34 0.0119306 4225.58 0.01168266 4226.81 0.01120718 4228.05 0.01103006 4229.28 0.01011544 4230.52 0.009576892 4231.75 0.009212226 4232.99 0.008579549 4234.22 0.008329982 4235.46 0.007559694 4236.69 0.006915113 4237.93 0.007005119 4239.16 0.006218351 4240.40 0.005901137 4241.63 0.006585083 4242.87 0.006923392 4244.10 0.006241585 4245.34 0.006103323 4246.57 0.005042056 4247.81 0.004749595 4249.04 0.005219905 4250.28 0.004987035 4251.51 0.00471774 4252.75 0.004449309 4253.98 0.00474888 4255.22 0.005067534 4256.45 0.004188258 4257.69 0.004417868 4258.92 0.004718987 4260.16 0.003538799 4261.39 0.003913933 4262.63 0.003981214 4263.86 0.00355345 4265.10 0.003782317 4266.33 0.004522177 4267.57 0.004021641 4268.81 0.004105866 4270.04 0.004075462 4271.28 0.003775166 4272.51 0.003551467 4273.75 0.003558837 4274.98 0.003398353 4276.22 0.002860652 4277.45 0.003740462 4278.69 0.003417802 4279.92 0.00295229 4281.16 0.003289659 4282.39 0.003418409 4283.63 0.00288211 4284.86 0.002668757 4286.10 0.003131025 4287.33 0.002672367 4288.57 0.002541172 4289.80 0.0029974 4291.04 0.003020734 4292.27 0.002821752 4293.51 0.002606445 4294.74 0.00209427 4295.98 0.002109251 4297.21 0.00220475 4298.45 0.002346739 4299.68 0.002098279 4300.92 0.002139093 4302.15 0.002193202 4303.39 0.002463483 4304.62 0.00225746 4305.86 0.002130071 4307.09 0.002087609 4308.33 0.001542959 4309.56 0.001768651 4310.80 0.001900385 4312.03 0.001781376 4313.27 0.002124426 4314.50 0.002050643 4315.74 0.001967928 4316.97 0.001761639 4318.21 0.001977421 4319.44 0.00217273 4320.68 0.001931615 4321.92 0.001760236 4323.15 0.001582393 4324.39 0.001890888 4325.62 0.002221265 4326.86 0.002199972 4328.09 0.002098095 4329.33 0.002033863 4330.56 0.001889973 4331.80 0.002276315 4333.03 0.002051499 4334.27 0.001722703 4335.50 0.001724968 4336.74 0.001983042 4337.97 0.002012473 4339.21 0.001689563 4340.44 0.001702679 4341.68 0.001961984 4342.91 0.001620262 4344.15 0.001299683 4345.38 0.001661546 4346.62 0.001880493 4347.85 0.001889004 4349.09 0.001756653 4350.32 0.001984224 4351.56 0.002303645 4352.79 0.002162134 4354.03 0.0016988 4355.26 0.001671135 4356.50 0.001856542 4357.73 0.001901328 4358.97 0.00191056 4360.20 0.00169611 4361.44 0.001866205 4362.67 0.001741364 4363.91 0.001931612 4365.14 0.001897379 4366.38 0.0015308 4367.61 0.001718485 4368.85 0.001670622 4370.08 0.001627074 4371.32 0.001320995 4372.55 0.001401533 4373.79 0.001558672 4375.02 0.001592279 4376.26 0.001330866 4377.50 0.001398108 4378.73 0.00168866 4379.97 0.002134013 4381.20 0.00148201 4382.44 0.001279098 4383.67 0.002000449 4384.91 0.002076564 4386.14 0.00183026 4387.38 0.00157049 4388.61 0.001791779 4389.85 0.00154753 4391.08 0.001461175 4392.32 0.001659309 4393.55 0.001510404 4394.79 0.001285702 4396.02 0.001421137 4397.26 0.001604524 4398.49 0.001549682 4399.73 0.001598889 4400.96 0.001657859 4402.20 0.001493341 4403.43 0.001422534 4404.67 0.001476716 4405.90 0.001336328 4407.14 0.001419661 4408.37 0.001580689 4409.61 0.001673983 4410.84 0.001306106 4412.08 7.494685E-4 4413.31 0.001060471 4414.55 0.001250844 4415.78 0.001467798 4417.02 0.001237035 4418.25 0.00103023 4419.49 0.001249491 4420.72 0.001138207 4421.96 0.001142816 4423.19 0.001512285 4424.43 0.001490051 4425.66 0.001306466 4426.90 0.001235261 4428.13 0.001067666 4429.37 0.001262621 4430.61 0.001420032 4431.84 0.001472304 4433.08 0.001352658 4434.31 0.001139787 4435.55 0.001483118 4436.78 0.001144923 4438.02 0.001071918 4439.25 9.828826E-4 4440.49 0.001096058 4441.72 9.918937E-4 4442.96 0.001341468 4444.19 0.001533715 4445.43 0.001375616 4446.66 0.0013765 4447.90 0.001065752 4449.13 0.00113625 4450.37 0.001146286 4451.60 0.001177122 4452.84 9.038046E-4 4454.07 0.001018586 4455.31 0.001067227 4456.54 0.001140118 4457.78 0.001078933 4459.01 9.180582E-4 4460.25 8.724048E-4 4461.48 8.600486E-4 4462.72 8.327133E-4 4463.95 0.001148013 4465.19 0.001120215 4466.42 9.536024E-4 4467.66 0.001150258 4468.89 0.00100418 4470.13 6.110798E-4 4471.36 8.351910E-4 4472.60 9.756461E-4 4473.83 9.219758E-4 4475.07 7.996284E-4 4476.30 0.00107612 4477.54 0.001019367 4478.77 8.939998E-4 4480.01 7.396238E-4 4481.24 0.001009497 4482.48 9.514025E-4 4483.72 9.713323E-4 4484.95 8.562726E-4 4486.19 8.052106E-4 4487.42 9.690811E-4 4488.66 0.001157839 4489.89 0.001046099 4491.13 0.001033867 4492.36 0.001233399 4493.60 0.00114219 4494.83 9.962009E-4 4496.07 9.651877E-4 4497.30 7.068911E-4 4498.54 8.091351E-4 4499.77 0.001048166 4501.01 0.001041674 4502.24 9.219209E-4 4503.48 9.062879E-4 4504.71 9.691361E-4 4505.95 9.248620E-4 4507.18 7.393470E-4 4508.42 8.513062E-4 4509.65 9.002883E-4 4510.89 0.001077933 4512.12 0.001044395 4513.36 9.916341E-4 4514.59 0.001117534 4515.83 9.479041E-4 4517.06 8.407835E-4 4518.30 8.604310E-4 4519.53 0.0010034 4520.77 0.00101972 4522.00 0.001221338 4523.24 9.647935E-4 4524.47 8.426607E-4 4525.71 0.00100486 4526.94 9.643491E-4 4528.18 0.001073568 4529.41 9.165921E-4 4530.65 9.653671E-4 4531.88 9.907009E-4 4533.12 8.724487E-4 4534.35 9.375978E-4 4535.59 0.001058696 4536.82 9.050817E-4 4538.06 7.201720E-4 4539.30 8.859439E-4 4540.53 8.411219E-4 4541.77 8.561746E-4 4543.00 9.992833E-4 4544.24 8.894108E-4 4545.47 0.001050664 4546.71 0.001217495 4547.94 0.001021434 4549.18 8.835092E-4 4550.41 8.557817E-4 4551.65 9.809611E-4 4552.88 9.480638E-4 4554.12 8.147091E-4 4555.35 0.001059801 4556.59 0.001058736 4557.82 9.709723E-4 4559.06 9.818965E-4 4560.29 7.636962E-4 4561.53 7.626655E-4 4562.76 8.495991E-4 4564.00 0.001049802 4565.23 0.001080599 4566.47 7.857876E-4 4567.70 6.216065E-4 4568.94 7.811928E-4 4570.17 9.740670E-4 4571.41 9.887331E-4 4572.64 0.001008994 4573.88 9.865572E-4 4575.11 7.978631E-4 4576.35 9.160793E-4 4577.58 9.126088E-4 4578.82 8.081394E-4 4580.05 8.178618E-4 4581.29 8.776385E-4 4582.52 6.235692E-4 4583.76 6.453593E-4 4584.99 8.040150E-4 4586.23 9.553434E-4 4587.46 9.239290E-4 4588.70 8.715995E-4 4589.93 7.929205E-4 4591.17 7.518121E-4 4592.41 7.778875E-4 4593.64 8.179399E-4 4594.88 9.424799E-4 4596.11 9.289673E-4 4597.35 7.639636E-4 4598.58 8.131844E-4 4599.82 5.062036E-4 4601.05 8.214412E-4 4602.29 9.319496E-4 4603.52 6.572969E-4 4604.76 6.339293E-4 4605.99 0.001060318 4607.23 7.999514E-4 4608.46 6.804410E-4 4609.70 8.653862E-4 4610.93 8.011000E-4 4612.17 6.052567E-4 4613.40 7.802605E-4 4614.64 9.300133E-4 4615.87 9.332573E-4 4617.11 8.475683E-4 4618.34 8.876268E-4 4619.58 7.758169E-4 4620.81 6.526973E-4 4622.05 5.215958E-4 4623.28 7.595171E-4 4624.52 6.521934E-4 4625.75 5.741770E-4 4626.99 6.898677E-4 4628.22 7.289030E-4 4629.46 7.539860E-4 4630.69 9.494897E-4 4631.93 0.00104842 4633.16 7.905945E-4 4634.40 7.401365E-4 4635.63 0.0010064 4636.87 7.950615E-4 4638.10 4.400854E-4 4639.34 6.156708E-4 4640.57 5.515840E-4 4641.81 9.560862E-4 4643.04 8.719474E-4 4644.28 7.758907E-4 4645.52 7.918090E-4 4646.75 7.295579E-4 4647.99 6.794402E-4 4649.22 7.134405E-4 4650.46 7.505953E-4 4651.69 5.991197E-4 4652.93 4.640451E-4 4654.16 5.153181E-4 4655.40 8.199579E-4 4656.63 8.139993E-4 4657.87 7.544829E-4 4659.10 7.191102E-4 4660.34 5.960482E-4 4661.57 8.128450E-4 4662.81 7.159693E-4 4664.04 7.647992E-4 4665.28 8.225197E-4 4666.51 7.278274E-4 4667.75 8.917269E-4 4668.98 8.684187E-4 4670.22 9.084225E-4 4671.45 7.314775E-4 4672.69 7.683694E-4 4673.92 8.510071E-4 4675.16 8.916154E-4 4676.39 7.442000E-4 4677.63 7.252661E-4 4678.86 7.763797E-4 4680.10 6.937422E-4 4681.33 7.510585E-4 4682.57 6.736957E-4 4683.80 8.112745E-4 4685.04 8.243548E-4 4686.27 6.948143E-4 4687.51 6.376713E-4 4688.74 6.725254E-4 4689.98 9.048904E-4 4691.21 8.503887E-4 4692.45 5.436299E-4 4693.68 6.666203E-4 4694.92 7.917302E-4 4696.15 6.063318E-4 4697.39 6.667346E-4 4698.62 8.149488E-4 4699.86 6.113365E-4 4701.10 5.548119E-4 4702.33 6.760246E-4 4703.57 6.492983E-4 4704.80 7.949143E-4 4706.04 7.619187E-4 4707.27 6.352765E-4 4708.51 6.635444E-4 4709.74 7.366530E-4 4710.98 8.218765E-4 4712.21 7.161318E-4 4713.45 7.820606E-4 4714.68 8.713946E-4 4715.92 6.920504E-4 4717.15 6.922830E-4 4718.39 8.140741E-4 4719.62 8.188214E-4 4720.86 7.648358E-4 4722.09 6.586971E-4 4723.33 7.069574E-4 4724.56 6.555187E-4 4725.80 7.476921E-4 4727.03 8.113640E-4 4728.27 6.042132E-4 4729.50 5.581263E-4 4730.74 5.444296E-4 4731.97 7.323464E-4 4733.21 7.242857E-4 4734.44 5.384978E-4 4735.68 4.030158E-4 4736.91 5.051314E-4 4738.15 7.104875E-4 4739.38 6.372398E-4 4740.62 5.515090E-4 4741.85 7.258697E-4 4743.09 7.111773E-4 4744.32 6.028698E-4 4745.56 7.119899E-4 4746.79 6.843617E-4 4748.03 6.806172E-4 4749.26 5.969600E-4 4750.50 6.232066E-4 4751.73 7.349179E-4 4752.97 6.791641E-4 4754.21 6.261851E-4 4755.44 3.805214E-4 4756.68 5.815247E-4 4757.91 5.836992E-4 4759.15 5.819771E-4 4760.38 5.155721E-4 4761.62 4.782256E-4 4762.85 5.673231E-4 4764.09 4.847401E-4 4765.32 6.279282E-4 4766.56 5.144005E-4 4767.79 4.195877E-4 4769.03 6.598613E-4 4770.26 6.091750E-4 4771.50 4.509022E-4 4772.73 5.772813E-4 4773.97 6.220824E-4 4775.20 7.109622E-4 4776.44 6.713422E-4 4777.67 5.889476E-4 4778.91 6.158917E-4 4780.14 6.017532E-4 4781.38 6.111852E-4 4782.61 4.944655E-4 4783.85 4.581934E-4 4785.08 5.571360E-4 4786.32 5.919093E-4 4787.55 4.900295E-4 4788.79 5.610025E-4 4790.02 6.363530E-4 4791.26 4.998632E-4 4792.49 4.794606E-4 4793.73 5.877628E-4 4794.96 4.821754E-4 4796.20 5.577410E-4 4797.43 6.629015E-4 4798.67 5.775390E-4 4799.90 4.926597E-4 4801.14 4.141831E-4 4802.37 5.580143E-4 4803.61 6.347800E-4 4804.84 4.560960E-4 4806.08 5.946016E-4 4807.32 6.065236E-4 4808.55 5.021330E-4 4809.79 4.255498E-4 4811.02 4.972136E-4 4812.26 5.442870E-4 4813.49 5.608142E-4 4814.73 5.819921E-4 4815.96 5.535602E-4 4817.20 4.921635E-4 4818.43 4.794116E-4 4819.67 6.130933E-4 4820.90 4.540026E-4 4822.14 3.210219E-4 4823.37 3.561265E-4 4824.61 4.716161E-4 4825.84 5.920540E-4 4827.08 4.710259E-4 4828.31 4.646834E-4 4829.55 5.589047E-4 4830.78 5.315751E-4 4832.02 4.900536E-4 4833.25 5.525424E-4 4834.49 5.716794E-4 4835.72 5.209646E-4 4836.96 4.694279E-4 4838.19 4.528739E-4 4839.43 5.389896E-4 4840.66 5.887662E-4 4841.90 5.100456E-4 4843.13 4.916652E-4 4844.37 4.951069E-4 4845.60 4.490478E-4 4846.84 5.388018E-4 4848.07 5.844315E-4 4849.31 4.430506E-4 4850.54 3.164581E-4 4851.78 4.110290E-4 4853.01 4.373663E-4 4854.25 4.942662E-4 4855.48 4.914473E-4 4856.72 4.607658E-4 4857.95 3.989057E-4 4859.19 3.538907E-4 4860.43 2.844484E-4 4861.66 4.098486E-4 4862.90 5.648518E-4 4864.13 5.327323E-4 4865.37 5.066643E-4 4866.60 4.778625E-4 4867.84 4.842078E-4 4869.07 4.677134E-4 4870.31 4.433626E-4 4871.54 4.317882E-4 4872.78 4.711575E-4 4874.01 4.704413E-4 4875.25 4.798679E-4 4876.48 3.223127E-4 4877.72 4.210359E-4 4878.95 4.293111E-4 4880.19 3.684716E-4 4881.42 3.849998E-4 4882.66 4.626039E-4 4883.89 3.313125E-4 4885.13 3.103440E-4 4886.36 4.154356E-4 4887.60 3.959509E-4 4888.83 3.484679E-4 4890.07 4.275677E-4 4891.30 3.267102E-4 4892.54 3.771572E-4 4893.77 4.937892E-4 4895.01 5.030362E-4 4896.24 3.637667E-4 4897.48 2.924798E-4 4898.71 3.875236E-4 4899.95 2.876061E-4 4901.18 2.858840E-4 4902.42 3.892836E-4 4903.65 3.039488E-4 4904.89 2.686682E-4 4906.12 3.578336E-4 4907.36 3.466355E-4 4908.59 3.867583E-4 4909.83 3.953930E-4 4911.06 3.738224E-4 4912.30 5.140027E-4 4913.53 4.081977E-4 4914.77 4.333486E-4 4916.01 5.071909E-4 4917.24 2.590257E-4 4918.48 3.484279E-4 4919.71 3.735774E-4 4920.95 3.250983E-4 4922.18 3.045728E-4 4923.42 3.829740E-4 4924.65 4.184809E-4 4925.89 2.948728E-4 4927.12 2.725365E-4 4928.36 4.402894E-4 4929.59 3.855902E-4 4930.83 3.758851E-4 4932.06 4.353110E-4 4933.30 3.535761E-4 4934.53 3.272054E-4 4935.77 3.456957E-4 4937.00 2.810480E-4 4938.24 2.869618E-4 4939.47 3.207266E-4 4940.71 3.606378E-4 4941.94 3.306355E-4 4943.18 3.425334E-4 4944.41 2.735033E-4 4945.65 2.511764E-4 4946.88 3.206525E-4 4948.12 3.315611E-4 4949.35 3.163296E-4 4950.59 2.604605E-4 4951.82 3.808087E-4 4953.06 3.440800E-4 4954.29 3.443195E-4 4955.53 4.102307E-4 4956.76 3.493191E-4 4958.00 3.105898E-4 4959.23 2.895755E-4 4960.47 2.817439E-4 4961.70 3.265377E-4 4962.94 3.810760E-4 4964.17 3.488067E-4 4965.41 3.332287E-4 4966.64 3.881950E-4 4967.88 3.807003E-4 4969.12 2.451484E-4 4970.35 2.798077E-4 4971.59 3.843514E-4 4972.82 3.256406E-4 4974.06 3.777575E-4 4975.29 3.910967E-4 4976.53 3.064399E-4 4977.76 2.404238E-4 4979.00 2.641881E-4 4980.23 3.382783E-4 4981.47 3.996827E-4 4982.70 3.919686E-4 4983.94 2.565405E-4 4985.17 2.882046E-4 4986.41 2.935633E-4 4987.64 2.812989E-4 4988.88 3.077867E-4 4990.11 4.146406E-4 4991.35 3.521299E-4 4992.58 3.135743E-4 4993.82 2.626355E-4 4995.05 2.937216E-4 4996.29 2.814408E-4 4997.52 1.296417E-4 4998.76 2.703103E-4 4999.99 2.835807E-4 5001.23 2.162038E-4 5002.46 2.833085E-4 5003.70 2.826100E-4 5004.93 2.898328E-4 5006.17 2.553150E-4 5007.40 2.570793E-4 5008.64 2.377033E-4 5009.87 3.677653E-4 5011.11 2.250470E-4 5012.34 3.067828E-4 5013.58 2.931891E-4 5014.81 2.985103E-4 5016.05 2.901071E-4 5017.28 2.887635E-4 5018.52 2.211035E-4 5019.75 3.364587E-4 5020.99 3.227636E-4 5022.23 2.761463E-4 5023.46 3.948300E-4 5024.70 4.741988E-4 5025.93 3.411863E-4 5027.17 3.433229E-4 5028.40 3.859385E-4 5029.64 3.262162E-4 5030.87 3.799088E-4 5032.11 4.074616E-4 5033.34 2.526644E-4 5034.58 1.917841E-4 5035.81 1.886566E-4 5037.05 1.916533E-4 5038.28 2.811543E-4 5039.52 2.450993E-4 5040.75 2.274771E-4 5041.99 3.020578E-4 5043.22 2.190779E-4 5044.46 2.958369E-4 5045.69 2.446657E-4 5046.93 4.273318E-4 5048.16 3.174730E-4 5049.40 3.050349E-4 5050.63 2.871053E-4 5051.87 3.733663E-4 5053.10 3.057170E-4 5054.34 2.694690E-4 5055.57 2.886605E-4 5056.81 1.988650E-4 5058.04 2.974626E-4 5059.28 3.312579E-4 5060.51 3.442654E-4 5061.75 3.509515E-4 5062.98 3.474402E-4 5064.22 3.746448E-4 5065.45 3.763826E-4 5066.69 2.223092E-4 5067.92 3.509992E-4 5069.16 3.167608E-4 5070.39 3.493180E-4 5071.63 3.699980E-4 5072.86 3.079181E-4 5074.10 3.159541E-4 5075.33 2.744206E-4 5076.57 3.034106E-4 5077.81 2.854255E-4 5079.04 3.696519E-4 5080.28 3.638963E-4 5081.51 2.021277E-4 5082.75 3.102889E-4 5083.98 3.499953E-4 5085.22 2.588347E-4 5086.45 2.184326E-4 5087.69 2.320343E-4 5088.92 2.902948E-4 5090.16 2.287677E-4 5091.39 2.585373E-4 5092.63 3.035250E-4 5093.86 2.461447E-4 5095.10 2.153360E-4 5096.33 2.234190E-4 5097.57 3.039924E-4 5098.80 2.810842E-4 5100.04 3.254373E-4 5101.27 3.049249E-4 5102.51 2.681787E-4 5103.74 3.520608E-4 5104.98 3.249987E-4 5106.21 3.202146E-4 5107.45 2.948841E-4 5108.68 3.440345E-4 5109.92 2.688305E-4 5111.15 3.631658E-4 5112.39 2.489130E-4 5113.62 2.671109E-4 5114.86 3.197237E-4 5116.09 3.067085E-4 5117.33 3.277849E-4 5118.56 3.586400E-4 5119.80 3.814688E-4 5121.03 3.317879E-4 5122.27 3.261358E-4 5123.50 3.867186E-4 5124.74 3.069402E-4 5125.97 3.180726E-4 5127.21 3.379986E-4 5128.44 3.860253E-4 5129.68 4.193831E-4 5130.92 2.888766E-4 5132.15 3.365020E-4 5133.39 2.405416E-4 5134.62 2.947455E-4 5135.86 3.528280E-4 5137.09 2.823375E-4 5138.33 2.656018E-4 5139.56 2.452050E-4 5140.80 2.321333E-4 5142.03 2.786483E-4 5143.27 3.190601E-4 5144.50 2.663251E-4 5145.74 3.090850E-4 5146.97 4.111368E-4 5148.21 3.002278E-4 5149.44 3.159401E-4 5150.68 2.712994E-4 5151.91 3.175023E-4 5153.15 3.879825E-4 5154.38 3.741737E-4 5155.62 3.387895E-4 5156.85 3.342920E-4 5158.09 3.865858E-4 5159.32 4.146894E-4 5160.56 3.647507E-4 5161.79 3.535491E-4 5163.03 3.045757E-4 5164.26 3.091872E-4 5165.50 3.301123E-4 5166.73 3.583786E-4 5167.97 4.497579E-4 5169.20 3.728504E-4 5170.44 3.377182E-4 5171.67 3.236407E-4 5172.91 3.615177E-4 5174.14 4.148562E-4 5175.38 4.185076E-4 5176.61 3.294302E-4 5177.85 3.515227E-4 5179.08 2.884098E-4 5180.32 3.811106E-4 5181.55 3.225256E-4 5182.79 2.507348E-4 5184.03 2.792047E-4 5185.26 3.171097E-4 5186.50 3.277489E-4 5187.73 4.235661E-4 5188.97 3.807707E-4 5190.20 3.579512E-4 5191.44 3.369888E-4 5192.67 3.276459E-4 5193.91 3.379387E-4 5195.14 3.733337E-4 5196.38 4.046079E-4 5197.61 3.590378E-4 5198.85 3.650162E-4 5200.08 3.413048E-4 5201.32 3.559856E-4 5202.55 4.229084E-4 5203.79 4.559032E-4 5205.02 4.037741E-4 5206.26 3.222690E-4 5207.49 3.472657E-4 5208.73 4.042905E-4 5209.96 3.794175E-4 5211.20 4.067761E-4 5212.43 3.871512E-4 5213.67 3.017447E-4 5214.90 3.376669E-4 5216.14 4.146890E-4 5217.37 3.967168E-4 5218.61 4.023860E-4 5219.84 4.354961E-4 5221.08 3.857086E-4 5222.31 3.651485E-4 5223.55 3.870338E-4 5224.78 3.797616E-4 5226.02 3.376983E-4 5227.25 3.671033E-4 5228.49 4.018690E-4 5229.72 3.623124E-4 5230.96 3.646205E-4 5232.19 3.465719E-4 5233.43 3.650407E-4 5234.66 3.735399E-4 5235.90 3.864487E-4 5237.13 4.470452E-4 5238.37 4.723454E-4 5239.61 4.241669E-4 5240.84 3.289316E-4 5242.08 3.555572E-4 5243.31 3.342791E-4 5244.55 3.381007E-4 5245.78 3.680096E-4 5247.02 3.635523E-4 5248.25 3.392473E-4 5249.49 3.078902E-4 5250.72 4.099132E-4 5251.96 4.515573E-4 5253.19 3.497958E-4 5254.43 3.481928E-4 5255.66 3.307287E-4 5256.90 3.480540E-4 5258.13 3.091948E-4 5259.37 3.493629E-4 5260.60 3.707590E-4 5261.84 3.978000E-4 5263.07 3.568770E-4 5264.31 3.629924E-4 5265.54 3.870390E-4 5266.78 3.773537E-4 5268.01 3.561036E-4 5269.25 4.724715E-4 5270.48 4.200588E-4 5271.72 4.161377E-4 5272.95 5.101794E-4 5274.19 4.068273E-4 5275.42 3.185588E-4 5276.66 3.700544E-4 5277.89 3.844297E-4 5279.13 3.829022E-4 5280.36 4.450722E-4 5281.60 4.374701E-4 5282.83 4.586871E-4 5284.07 4.441797E-4 5285.30 4.064871E-4 5286.54 4.323915E-4 5287.77 4.993632E-4 5289.01 4.768746E-4 5290.24 5.026057E-4 5291.48 4.550756E-4 5292.72 3.987512E-4 5293.95 4.127928E-4 5295.19 4.597305E-4 5296.42 4.461991E-4 5297.66 4.293041E-4 5298.89 5.233700E-4 5300.13 5.028212E-4 5301.36 4.405264E-4 5302.60 4.274708E-4 5303.83 4.445003E-4 5305.07 4.770484E-4 5306.30 4.203208E-4 5307.54 4.821600E-4 5308.77 4.196619E-4 5310.01 4.282537E-4 5311.24 5.230122E-4 5312.48 4.573877E-4 5313.71 3.514974E-4 5314.95 3.568254E-4 5316.18 4.445520E-4 5317.42 4.415124E-4 5318.65 4.477235E-4 5319.89 4.423292E-4 5321.12 4.764531E-4 5322.36 5.102130E-4 5323.59 4.644594E-4 5324.83 4.070215E-4 5326.06 4.707283E-4 5327.30 4.384108E-4 5328.53 4.496011E-4 5329.77 4.874260E-4 5331.00 4.342486E-4 5332.24 4.310644E-4 5333.47 4.422590E-4 5334.71 4.898030E-4 5335.94 5.204516E-4 5337.18 4.648797E-4 5338.41 4.258654E-4 5339.65 4.341578E-4 5340.88 4.000533E-4 5342.12 3.852639E-4 5343.35 4.724275E-4 5344.59 4.328359E-4 5345.83 3.755226E-4 5347.06 4.244052E-4 5348.30 4.654414E-4 5349.53 5.140198E-4 5350.77 4.477543E-4 5352.00 3.639262E-4 5353.24 3.851030E-4 5354.47 4.217836E-4 5355.71 3.666685E-4 5356.94 3.137244E-4 5358.18 3.842637E-4 5359.41 3.429512E-4 5360.65 3.215861E-4 5361.88 3.817567E-4 5363.12 3.509423E-4 5364.35 3.705694E-4 5365.59 3.687666E-4 5366.82 3.257124E-4 5368.06 3.512049E-4 5369.29 3.556314E-4 5370.53 2.931726E-4 5371.76 2.195983E-4 5373.00 2.003223E-4 5374.23 2.500981E-4 5375.47 2.760670E-4 5376.70 3.832770E-4 5377.94 3.574942E-4 5379.17 2.086468E-4 5380.41 2.464628E-4 5381.64 2.619859E-4 5382.88 1.809220E-4 5384.11 1.908262E-4 5385.35 1.488879E-4 5386.58 1.826428E-4 5387.82 1.804656E-4 5389.05 2.897674E-4 5390.29 2.411126E-4 5391.52 2.089374E-4 5392.76 2.764526E-4 5393.99 2.073248E-4 5395.23 1.589745E-4 5396.46 2.112394E-4 5397.70 2.004393E-4 5398.94 2.441407E-4 5400.17 2.824864E-4 5401.41 2.125046E-4 5402.64 2.585872E-4 5403.88 2.403953E-4 5405.11 2.594372E-4 5406.35 2.664885E-4 5407.58 2.479556E-4 5408.82 2.258370E-4 5410.05 2.286343E-4 5411.29 1.787778E-4 5412.52 2.396877E-4 5413.76 1.459406E-4 5414.99 2.318198E-4 5416.23 1.450325E-4 5417.46 1.288993E-4 5418.70 1.623360E-4 5419.93 1.042920E-4 5421.17 1.500518E-4 5422.40 1.635724E-4 5423.64 1.014529E-4 5424.87 1.312197E-4 5426.11 2.040200E-4 5427.34 1.721953E-4 5428.58 1.220212E-4 5429.81 1.834274E-4 5431.05 1.723190E-4 5432.28 1.275925E-4 5433.52 1.015287E-4 5434.75 1.003222E-4 5435.99 1.206587E-4 5437.22 7.664416E-5 5438.46 7.884055E-5 5439.69 1.658936E-4 5440.93 1.625241E-4 5442.16 9.578028E-5 5443.40 7.245945E-5 5444.63 8.759325E-5 5445.87 1.349271E-4 5447.10 1.628956E-4 5448.34 1.459329E-4 5449.57 1.374391E-4 5450.81 1.391303E-4 5452.04 1.555435E-4 5453.28 1.575776E-4 5454.52 1.037902E-4 5455.75 1.269883E-4 5456.99 1.626345E-4 5458.22 1.324375E-4 5459.46 1.413449E-4 5460.69 1.763845E-4 5461.93 1.124600E-4 5463.16 8.136088E-5 5464.40 5.678059E-5 5465.63 1.256096E-4 5466.87 1.412960E-4 5468.10 8.361525E-5 5469.34 1.636491E-4 5470.57 1.339233E-4 5471.81 1.402457E-4 5473.04 1.684554E-4 5474.28 1.112210E-4 5475.51 9.264514E-5 5476.75 1.314672E-4 5477.98 1.543030E-4 5479.22 1.467496E-4 5480.45 1.426346E-4 5481.69 1.465275E-4 5482.92 7.279310E-5 5484.16 1.107669E-4 5485.39 1.601390E-4 5486.63 9.036288E-5 5487.86 8.142842E-5 5489.10 1.483064E-4 5490.33 1.563445E-4 5491.57 8.685092E-5 5492.80 6.305874E-5 5494.04 5.870151E-5 5495.27 6.363814E-5 5496.51 5.155237E-5 5497.74 2.967365E-5 5498.98 3.332262E-5 5500.21 4.629571E-5 5501.45 4.044640E-5 5502.68 9.846901E-6 5503.92 1.411042E-5 5505.15 7.695637E-6 5506.39 1.073395E-5 5507.63 2.903405E-6 5508.86 1.159357E-5 5510.10 4.472227E-5 5511.33 4.751096E-5 5512.57 6.663676E-5 5513.80 2.540485E-5 5515.04 -2.586377E-5 5516.27 1.842042E-5 5517.51 -3.098399E-5 5518.74 1.636987E-5 5519.98 3.904584E-5 5521.21 3.392132E-5 5522.45 4.902483E-5 5523.68 6.151634E-5 5524.92 2.950873E-5 5526.15 -6.849671E-6 5527.39 3.712999E-5 5528.62 1.800352E-5 5529.86 2.456406E-6 5531.09 1.426260E-5 5532.33 5.622560E-5 5533.56 5.170071E-5 5534.80 4.996085E-6 5536.03 -9.221871E-6 5537.27 -6.511961E-5 5538.50 -3.077345E-5 5539.74 -3.512796E-5 5540.97 -3.370950E-5 5542.21 -6.702321E-5 5543.44 -1.025881E-4 5544.68 -6.871181E-5 5545.91 -6.398256E-5 5547.15 -8.302950E-5 5548.38 -4.645794E-5 5549.62 -5.569760E-5 5550.85 -6.159046E-5 5552.09 -1.025233E-4 5553.32 -6.490872E-5 5554.56 -7.938173E-5 5555.79 -9.110822E-5 5557.03 -5.942333E-5 5558.26 4.381468E-6 5559.50 -2.571179E-6 5560.74 -7.840871E-5 5561.97 -7.540950E-5 5563.21 -7.141855E-6 5564.44 -1.765683E-4 5565.68 -1.081484E-4 5566.91 -7.276470E-5 5568.15 -4.816354E-5