ABORTEX abort-exposure logical ACPOWER ac-power logical ADDFRAME add-frame-numbers logical AIRALARM air-pressure-alarm logical AIRPRESS air-pressure real number AMPLIST readout-amplifiers array of integers[4] AUTOERAS automatic-erase logical AUTOFILL automatic-dewar-fill integer AUTOREAD automatic-readout logical AUTOSHUT automatic-shutter logical AUX1ON auxillary-power-1 logical AUX2ON auxillary-power-2 logical BCCVCLOS blue-collimator-cover-closed logical BCCVOPEN blue-collimator-cover-open logical BCOCOVER blue-collimator-cover logical BINNING binning array of integers[2] BMONAIO broadcast-monitor-analog-io logical BMONDCIO broadcast-monitor-dc-stage-io logical BMONDIO broadcast-monitor-digital-io logical BMONLAMP broadcast-monitor-lamp-io logical CAFBRAK camera-focus-brake logical CAFCON camera-focus-control logical CAFFID camera-focus-fiducial logical CAFINH camera-focus-inhibit logical CAFLIMF camera-focus-forward-limit logical CAFLIMR camera-focus-reverse-limit logical CAFOSC camera-focus-dithering-parameters array of integers[3] CAFDITH camera-focus-dither logical CAFSTAT camera-focus-status logical CAFCAL camera-focus-calibration logical CAFDEST camera-focus-destination integer CAFNAME camera-focus-name ascii string CAFPOS camera-focus-discrete-position integer CAFRAW camera-focus-raw-position integer CAFREL camera-focus-relative-position integer CAFOCUS camera-focus-location real number CACVCLOS camera-cover-closed logical CACVOPEN camera-cover-open logical CAMCON camera-cover-control logical CAMCOVER camera-cover logical CATCUR1 cathode1-current real number CATCUR2 cathode2-current real number CATCUR3 cathode3-current real number CATCUR4 cathode4-current real number CATH1RAW cathode1-current-raw integer CATH2RAW cathode2-current-raw integer CATH3RAW cathode3-current-raw integer CATH4RAW cathode4-current-raw integer CPOWRAW cathode-power-supply-status-raw integer CATPOW cathode-power-supply-status real number CATON cathode-power-control logical CCDGAIN ccd-gain logical COFBRAK collimator-focus-brake logical COFCON collimator-focus-control logical COFFID collimator-focus-fiducial logical COFINH collimator-focus-inhibit logical COFLIMF collimator-focus-forward-limit logical COFLIMR collimator-focus-reverse-limit logical COFOSC collimator-focus-dithering-parameters array of integers[3] COFDITH collimator-focus-dither logical COFSTAT collimator-focus-status logical COFCAL collimator-focus-calibration logical COFDEST collimator-focus-destination integer COFNAME collimator-focus-name ascii string COFPOS collimator-focus-discrete-position integer COFRAW collimator-focus-raw-position integer COFREL collimator-focus-relative-position integer COFOCUS collimator-focus-location real number COLLBRAK collimator-brake logical COLLCON collimator-control logical COLL collimator-select logical COLLRED collimator-select-red logical COLLBLUE collimator-select-blue logical COOLFLOW external-coolant-flow logical C1CVCLOS corrector1-cover-closed logical C1CVOPEN corrector1-cover-open logical CO1COVER corrector1-cover logical C2CVCLOS corrector2-cover-closed logical C2CVOPEN corrector2-cover-open logical CO2COVER corrector2-cover logical CSHUTTER camera-shutter logical DARKSLID dark-slide logical DARKCLOS dark-slide-closed logical DARKOPEN dark-slide-open logical DATALINE data-lines integer DATAPIX data-pixels integer DECKCON decker-control logical DECKFID decker-fiducial logical DECKINH decker-inhibit logical DECKLIMF decker-forward-limit logical DECKLIMR decker-reverse-limit logical DECKOSC decker-dithering-parameters array of integers[3] DECKDITH decker-dither logical DECKSTAT decker-status logical DECKCAL decker-calibration logical DECKDEST decker-destination integer DECKNAME decker-name ascii string DECKPOS decker-discrete-position integer DECKRAW decker-raw-position integer DECKREL decker-relative-position integer DECKLOC decker-location real number DETECTOR detector ascii string DEWARID dewar-id integer DFORM disk-file-format ascii string DOOR door logical DWRMANF dewar-manual-fill logical DWRN2LV ccd-dewar-nitrogen-level real number DWRN2LVM ccd-dewar-nitrogen-level-map array of real numbers[5] DWRN2LVR ccd-dewar-nitrogen-level-raw integer ECHBRAK echelle-brake logical ECHCON echelle-control logical ECHFID echelle-fiducial logical ECHINH echelle-inhibit logical ECHLIMF echelle-forward-limit logical ECHLIMR echelle-reverse-limit logical ECHOSC echelle-dithering-parameters array of integers[3] ECHDITH echelle-dither logical ECHSTAT echelle-status logical ECHCAL echelle-calibration logical ECHDEST echelle-destination integer ECHNAME echelle-name ascii string ECHPOS echelle-discrete-position integer ECHRAW echelle-raw-position integer ECHREL echelle-relative-position integer ECHANGL echelle-angle real number ECHPIX echelle-pixel-position real number ECOVCLOS echelle-cover-closed logical ECOVOPEN echelle-cover-open logical ECHCOVER echelle-cover logical ELAPTIME elapsed-time integer ERASECNT erase-count integer ERASEIP erase-in-progress logical ERASLINE erase-line logical ESTOP emergency-stop logical EXPOSE start-exposure logical EXPOSIP exposure-in-progress logical FIL1CON filter1-control logical FIL1FID filter1-fiducial logical FIL1INH filter1-inhibit logical FIL1OSC filter1-dithering-parameters array of integers[3] FIL1DITH filter1-dither logical FIL1STAT filter1-status logical FIL1CAL filter1-calibration logical FIL1DEST filter1-destination integer FIL1NAME filter1-name ascii string FIL1POS filter1-discrete-position integer FIL1RAW filter1-raw-position integer FIL1REL filter1-relative-position integer FIL1ANGL filter1-angle real number FIL2CON filter2-control logical FIL2FID filter2-fiducial logical FIL2INH filter2-inhibit logical FIL2OSC filter2-dithering-parameters array of integers[3] FIL2DITH filter2-dither logical FIL2STAT filter2-status logical FIL2CAL filter2-calibration logical FIL2DEST filter2-destination integer FIL2NAME filter2-name ascii string FIL2POS filter2-discrete-position integer FIL2RAW filter2-raw-position integer FIL2REL filter2-relative-position integer FIL2ANGL filter2-angle real number FRAMENO frame-number integer HATCON hatch-control logical HATCH hatch logical HATCLOS hatch-closed logical HATOPEN hatch-open logical HMOTBOOT hires-reboot integer HUMIDRAW relative-humidity-raw integer INSTRUME instrument ascii string IODCON iodine-cell-control logical IODCELL iodine-cell logical IODHEAT iodine-heater logical IODIN iodine-cell-in logical IODOUT iodine-cell-out logical IONCRAW ion-pump-current_raw integer IONCUR ion-pump-current real number IONPUMP ion-pump logical KEEPPREP keep-prescan-pixels logical LAMPFAN lamp-fan logical LAMP comparison-lamp integer LAMPNAME lamp-name ascii string LAMPCAT1 hollow-cathode-lamp1 logical LAMPCAT2 hollow-cathode-lamp2 logical LAMPQTZ1 quartz-lamp1 logical LAMPQTZ2 quartz-lamp2 logical LAMPLSR laser-power logical LAMPDEUT deuterium-lamp logical LFILCON lamp-filter-control logical LFILFID lamp-filter-fiducial logical LFILINH lamp-filter-inhibit logical LFILOSC lamp-filter-dithering-parameters array of integers[3] LFILDITH lamp-filter-dither logical LFILSTAT lamp-filter-status logical LFILCAL lamp-filter-calibration logical LFILDEST lamp-filter-destination integer LFILNAME lamp-filter-name ascii string LFILPOS lamp-filter-discrete-position integer LFILRAW lamp-filter-raw-position integer LFILREL lamp-filter-relative-position integer LFILANGL lamp-filter-angle real number LIGHTS interior-lights logical LMIRROUT comparison-lamp-mirror-out logical LMIRRIN comparison-lamp-mirror-in logical LMIRR comparison-lamp-mirror logical LSELCON lamp-select-control logical LSELFID lamp-select-fiducial logical LSELINH lamp-select-inhibit logical LSELLIMF lamp-select-forward-limit logical LSELLIMR lamp-select-reverse-limit logical LSELOSC lamp-select-dithering-parameters array of integers[3] LSELDITH lamp-select-dither logical LSELSTAT lamp-select-status logical LSELCAL lamp-select-calibration logical LSELDEST lamp-select-destination integer LSELNAME lamp-select-name ascii string LSELPOS lamp-select-discrete-position integer LSELRAW lamp-select-raw-position integer LSELREL lamp-select-relative-position integer LSELLOC lamp-select-location real number MONDCMAN monitor-dc-stage-auto-manual logical MONSYSDL monitor-system-disable logical MONION monitor-ion-pump-power logical MONAIR monitor-pressurized-air logical MONCOOL monitor-external-coolant logical MONIODT monitor-iodine-cell-temperature logical MONLAMPT monitor-lamp-enclosure-temperature logical MONRACKT monitor-electronics-enclosure-temperaturelogical MONTVT monitor-tv-enclosure-temperature logical MONPOW monitor-motor-power-supplies logical MONUPS monitor-ups logical MONENV monitor-environment logical MOPOW1 motor-power-supply1-status real number MOPOW2 motor-power-supply2-status real number MOPOW3 motor-power-supply3-status real number MPOW1RAW motor-power-supply1-raw integer MPOW2RAW motor-power-supply2-raw integer MPOW3RAW motor-power-supply3-raw integer MPPMODE mpp-readout-mode logical NUMAMPS number-of-readout-amplifiers integer NSUBINT number-of-subintegrations integer OBSERVER observer ascii string OVRFLUSH postscan-flush-lines integer PAUSEIP pause-in-progress logical POSTLINE postscan-lines integer POSTPIX postscan-pixels integer PREFLUSH prescan-flush-lines integer PRELINE prescan-lines integer PREPIX prescan-pixels integer PWRBLOK ccd-dewar-heater-voltage real number PWRBLOKM ccd-dewar-heater-voltage-map array of real numbers[5] PWRBLOKR ccd-dewar-heater-voltage-raw integer OUTDIR readout-directory ascii string PRESSRAW air-pressure-raw integer OUTFILE readout-filename ascii string PAUSE pause-exposure logical RACKDOWN electronics-rack-power-control logical RCCVCLOS red-collimator-cover-closed logical RCCVOPEN red-collimator-cover-open logical RCOCOVER red-collimator-cover logical RELHUM relative-humidity real number RESN2LV ccd-reservoir-nitrogen-level real number RESN2LVM ccd-reservoir-nitrogen-level-map array of real numbers[5] RESN2LVR ccd-reservoir-nitrogen-level-raw integer RESUME resume-exposure logical ROWSHFT row-shift-per-subintegrations integer SETIODT set-iodine-cell-temperature real number SHUTCLOS shutter-closed logical SHUTOPEN shutter-open logical SHUTSTAT shutter-status integer SLITCON slit-control logical SLITFID slit-fiducial logical SLITINH slit-inhibit logical SLITLIMF slit-forward-limit logical SLITLIMR slit-reverse-limit logical SLITOSC slit-dithering-parameters array of integers[3] SLITDITH slit-dither logical SLITSTAT slit-status logical SLITCAL slit-calibration logical SLITDEST slit-destination integer SLITNAME slit-name ascii string SLITPOS slit-discrete-position integer SLITRAW slit-raw-position integer SLITREL slit-relative-position integer SLITWID slit-width real number STOPEX stop-exposure logical SYSDIS system-disabled logical TEMPDET detector-temperature real number TEMPDETM detector-temperature-map array of real numbers[5] TEMPDETR detector-temperature-raw integer TEMPSET ccd-desired-dewar-temperature real number TEMPSETM ccd-desired-dewar-temperature-map array of real numbers[5] TEMPSETR ccd-desired-dewar-temperature-raw integer TEMPCOOL external-coolant-temperature real number TEMPIN inside-temperature real number TEMPIOD1 iodine-cell-temperature1 real number TEMPIOD2 iodine-cell-temperature2 real number TEMPLAMP lamp-enclosure-temperature real number TEMPOUT outside-temperature real number TEMPRACK rack-temperature real number TEMPTV tv-enclosure-temperature real number TINRAW inside-temperature-raw integer TOUTRAW outside-temperature-raw integer TCOOLRAW coolant-temperature-raw integer TIOD1RAW iodine-cell-temperature1-raw integer TIOD2RAW iodine-cell-temperature2-raw integer TLAMPRAW lamp-temperature-raw integer TRACKRAW rack-temperature-raw integer TTVRAW tv-enclosure-temperature-raw integer TTIME total-time integer TODISK to-disk logical TOTAPE to-tape logical TAPEDEV tape-device ascii string TVACON tv-aperture-control logical TVAFID tv-aperture-fiducial logical TVAINH tv-aperture-inhibit logical TVAOSC tv-aperture-dithering-parameters array of integers[3] TVADITH tv-aperture-dither logical TVASTAT tv-aperture-status logical TVACAL tv-aperture-calibration ascii string TVADEST tv-aperature-destination integer TVANAME tv-aperture-name ascii string TVAPOS tv-aperture-discrete-position integer TVARAW tv-aperture-raw-position integer TVAREL tv-aperture-relative-position integer TVFCON tv-focus-control logical TVFFID tv-focus-fiducial logical TVFINH tv-focus-inhibit logical TVFLIMF tv-focus-forward-limit logical TVFLIMR tv-focus-reverse-limit logical TVFOSC tv-focus-dithering-parameters array of integers[3] TVFDITH tv-focus-dither logical TVFSTAT tv-focus-status logical TVFCAL tv-focus-calibration logical TVFDEST tv-focus-destination integer TVFNAME tv-focus-name ascii string TVFPOS tv-focus-discrete-position integer TVFRAW tv-focus-raw-position integer TVFREL tv-focus-relative-position integer TVFOCUS tv-focus-location real number TVFANGL tv-focus-angle real number TVF1CON tv-filter1-control logical TVF1FID tv-filter1-fiducial logical TVF1INH tv-filter1-inhibit logical TVF1OSC tv-filter1-dithering-parameters array of integers[3] TVF1DITH tv-filter1-dither logical TVF1STAT tv-filter1-status logical TVF1CAL tv-filter1-calibration logical TVF1DEST tv-filter1-destination integer TVF1NAME tv-filter1-name ascii string TVF1POS tv-filter1-discrete-position integer TVF1RAW tv-filter1-raw-position integer TVF1REL tv-filter1-relative-position integer TVF1ANGL tv-filter1-angle real number TVF2CON tv-filter2-control logical TVF2FID tv-filter2-fiducial logical TVF2INH tv-filter2-inhibit logical TVF2OSC tv-filter2-dithering-parameters array of integers[3] TVF2DITH tv-filter2-dither logical TVF2STAT tv-filter2-status logical TVF2CAL tv-filter2-calibration logical TVF2DEST tv-filter2-destination integer TVF2NAME tv-filter2-name ascii string TVF2POS tv-filter2-discrete-position integer TVF2RAW tv-filter2-raw-position integer TVF2REL tv-filter2-relative-position integer TVF2ANGL tv-filter2-angle real number TVFAN tv-fan logical TVON tv-controller-power logical VAULTFAN vault-fan logical VOFFSET0 video-offset-amplifier-0 integer VOFFSET1 video-offset-amplifier-1 integer VOFFSET2 video-offset-amplifier-2 integer VOFFSET3 video-offset-amplifier-3 integer UPSDOWN ups-power-control logical UPSLOW ups-battery-low logical UPSON ups-power logical UPSBYPAS ups-bypassed logical UTB15VEN ccd-15-volts-enable logical UTB30VEN ccd-30-volts-enable logical UTBFANS ccd-controller-fans logical UTBM15V ccd-minus-15-volts real number UTBM15VM ccd-minus-15-volts-map array of real numbers[5] UTBM15VR ccd-minus-15-volts-raw integer UTBN2FIL ccd-liquid-n2-pressure-valve logical UTBN2HTR ccd-liquid-n2-reservoir-heater logical UTBP15V ccd-plus-15-volts real number UTBP15VM ccd-plus-15-volts-map array of real numbers[5] UTBP15VR ccd-plus-15-volts-raw integer UTBP30V ccd-plus-30-volts real number UTBP30VM ccd-plus-30-volts-map array of real numbers[5] UTBP30VR ccd-plus-30-volts-raw integer UTBP5V ccd-plus-5-volts real number UTBP5VM ccd-plus-5-volts-map array of real numbers[5] UTBP5VR ccd-plus-5-volts-raw integer UTBTEMP ccd-utility-board-temperature real number UTBTEMPM ccd-utility-board-temperature-map array of real numbers[5] UTBTEMPR ccd-utility-board-temperature-raw integer UTBTMPS ccd-desired-utility-board-temperature real number UTBTMPSM ccd-desired-utility-board-temperature-maparray of real numbers[5] UTBTMPSR ccd-desired-utility-board-temperature-rawinteger VME5 vme-plus-5v-power-status real number VME12 vme-12v-power-status real number VME5RAW vme-plus-5v-power-raw integer VME12RAW vme-12v-power-raw integer WDISK writing-disk logical WCRATE writing-crate-memory logical DWINDOW desired-window array of integers[5] PWINDOW physical-window array of integers[5] WINDOW window array of integers[5] XDBRAK cross-disperser-brake logical XDCON cross-disperser-control logical XDFID cross-disperser-fiducial logical XDINH cross-disperser-inhibit logical XDLIMF cross-disperser-forward-limit logical XDLIMR cross-disperser-reverse-limit logical XDOSC cross-disperser-dithering-parameters array of integers[3] XDDITH cross-disperser-dither logical XDSTAT cross-disperser-status logical XDCAL cross-disperser-calibration logical XDDEST cross-disperser-destination integer XDNAME cross-disperser-name ascii string XDPOS cross-disperser-discrete-position integer XDRAW cross-disperser-raw-position integer XDREL cross-disperser-relative-position integer XDANGL cross-disperser-angle real number XDPIX cross-disperser-pixel-position real number XCOVCLOS cross-disperser-cover-closed logical XCOVOPEN cross-disperser-cover-open logical XDCOVER cross-disperser-cover logical