ACSSTAT active-control-status enumerated integer bit-mask AUTSTAT autoguider-enabled logical AUTXOFF autoguider-x-offset double number AUTYOFF autoguider-y-offset double number AXESTAT axes-control-status enumerated integer bit-mask AIRMASS air-mass double number AZ telescope-azimuth double number AZDEST azimuth-destination double number AZOFF azimuth-offset double number CA collimation-azimuth double number CALOCAL collimation-azimuth-local double number CASESS collimation-azimuth-session double number CAPERM collimation-azimuth-permanent double number CE collimation-elevation double number CELOCAL collimation-elevation-local double number CESESS collimation-elevation-session double number CEPERM collimation-elevation-permanent double number COPRESET collimation-preset integer bit-mask DATE universal-date double number DATE-OBS universal-date-of-observation double number DCSHOST drive-and-control-host ascii string DCSLOCK drive-and-control-locked logical DCSPORT drive-and-control-port ascii string DCSSTAT drive-and-control-status enumerated integer bit-mask DCSVERS drive-and-control-version ascii string DEC telescope-declination double number DECBASE telescope-declination-base double number DECOFF declination-offset double number DOMEPOSN dome-azimuth double number DOMESTAT dome-status enumerated integer bit-mask DTRACK differential-tracking-enabled logical EL telescope-elevation double number ELDEST elevation-destination double number ELOFF elevation-offset double number ELVEL elevation-velocity double number EQUINOX telescope-equinox double number FOCALSTN focal-station enumerated integer FRAME telescope-frame enumerated integer bit-mask HA telescope-hour-angle double number HALT halt-telescope logical HANDPAD handpaddle-enabled logical HELIORVC heliocentric-correction double number INSTRUME instrument-name ascii string INSTXOFF instrument-x-offset double number INSTYOFF instrument-y-offset double number LST local-apparent-sidereal-time double number LOGTASK loglevel-task-name ascii string LOGLEVEL loglevel-bitmask integer MARK mark-current-as-base logical MCOVER mirror-cover-status enumerated integer bit-mask MJD modified-julian-date double number MJD-OBS modified-julian-date-of-observation double number MOVECHK move-check-status logical MOVETEL move-telescope enumerated integer MOVETELB move-telescope-base enumerated integer MOVETELR move-telescope-relative enumerated integer OBJECT object-name ascii string PARANG telescope-parallactic-angle double number POCANCEL pointing-origin-cancel logical PONAME pointing-origin-name ascii string PONAME1 pointing-origin-name-1 ascii string PONAME2 pointing-origin-name-2 ascii string PONAME3 pointing-origin-name-3 ascii string PONAME4 pointing-origin-name-4 ascii string POPRESET pointing-origin-preset logical POSELECT pointing-origin-select logical POXPOS pointing-origin-xposition double number POXPOS1 pointing-origin-xposition-1 double number POXPOS2 pointing-origin-xposition-2 double number POXPOS3 pointing-origin-xposition-3 double number POXPOS4 pointing-origin-xposition-4 double number POYPOS pointing-origin-yposition double number POYPOS1 pointing-origin-yposition-1 double number POYPOS2 pointing-origin-yposition-2 double number POYPOS3 pointing-origin-yposition-3 double number POYPOS4 pointing-origin-yposition-4 double number POSTAT pointing-origin-status integer bit-mask POSTAT1 pointing-origin-status-1 integer bit-mask POSTAT2 pointing-origin-status-2 integer bit-mask POSTAT3 pointing-origin-status-3 integer bit-mask POSTAT4 pointing-origin-status-4 integer bit-mask PRESERVE preserve-pointing logical TELSHORT tel-shortest-path logical AZWRAPCW use-cw-az-wrap logical AZWRAPCC use-ccw-az-wrap logical RA telescope-right-ascension double number RABASE telescope-right-ascension-base double number RADECSYS ra-dec-coordinate-system enumerated integer bit-mask RAOFF right-ascension-offset double number REL2CURR relative-to-current enumerated integer REL2BASE relative-to-base enumerated integer ROTDEST rotator-user-destination double number ROTMODE rotator-tracking-mode enumerated integer bit-mask ROTPDEST rotator-physical-destination double number ROTPPOSN rotator-physical-angle double number ROTPOSN rotator-user-angle double number ROTSTAT rotator-status enumerated integer bit-mask ROTWTIME rotator-wrap-time double number SCALED scaled-offset logical SCAN scan-active logical SECACTU1 secondary-actuator-1 double number SECACTU2 secondary-actuator-2 double number SECACTU3 secondary-actuator-3 double number SECFOCUS secondary-mirror-focus-raw double number SECSTAT secondary-mirror-status enumerated integer bit-mask SECTHETX secondary-mirror-thetax double number SECTHETY secondary-mirror-thetay double number SECOFFT secondary-temp-offset double number SECOFFE secondary-el-offset double number SECREQT secondary-req-temp-comp logical SECREQE secondary-req-el-comp logical SECTEMP secondary-auto-temp-comp logical SECEL secondary-auto-el-comp logical SECRAW secondary-cmd-raw-focus logical SECCALIB secondary-calib-comp logical STRKERR servo-tracking-error double number SHUTPOSN shutter-elevation double number SHUTSTAT shutter-status enumerated integer bit-mask SIMUTC simulating-utc double number SIMULATE simulating-dcs logical ST local-apparent-sidereal-time double number SUBSYS subsystem-names integer bit-mask TARGAZ target-azimuth double number TARGDEC target-declination double number TARGEL target-elevation double number TARGEPOC target-epoch double number TARGEQUI target-equinox double number TARGFRAM target-frame enumerated integer bit-mask TARGNAME target-name ascii string TARGPLAX target-parallax double number TARGPMDC target-proper-motion-dec double number TARGPMRA target-proper-motion-ra double number TARGRADV target-radial-velocity double number TARGRA target-right-ascension double number TELESCOP telescope-name ascii string TELFOCUS telescope-focus-compensated double number TERTSTAT tertiary-mirror-status enumerated integer bit-mask TUBETEMP tube-temperature double number TVXOFF tv-x-offset double number TVYOFF tv-y-offset double number UT coordinated-universal-time double number UTC coordinated-universal-time double number