![]() |
|
|
Wavelengths between 3850 Å and 8850 Å.
| Star No. |
Name | RA (2000) | Dec (2000) | Spec Type |
AB (5556 Å) |
B-V |
|---|---|---|---|---|---|---|
| 1 | Feige 11 | 01:04:21.6 | +04:13:37 | sdB | 12.07 | -0.24 |
| 2 | xi² Cet | 02:28:09.5 | +08:27:36 | B9 III | 4.29 | -0.06 |
| 3 | GD 50 | 03:48:50.0 | -00:58:29 | DA2 | 14.06 | -0.28 |
| 4 | HZ 4 | 03:55:21.7 | +09:47:18 | DA4 | 14.52 | +0.08 |
| 5 | HD 27836 | 04:24:12.1 | +14:45:30 | G1 V | 7.62 | +0.60 |
| 6 | G191B2B | 05:05:30.3 | +52:49:54 | DA0 | 11.78 | -0.32 |
| 7 | PG 0918+029 | 09:21:27.8 | +02:46:06 | ... | 13.33 | -0.27 |
| 8 | GD 108 | 10:00:47.3 | -07:33:33 | sdB? | 13.56 | -0.22 |
| 9 | G162-66 | 10:33:43.6 | -11:41:42 | DA2 | 13.01 | -0.17 |
| 10 | PG 1034+001 | 10:37:04.0 | -00:08:20 | DO | 13.23 | -0.37 |
| 11 | Feige 34 | 10:39:37.6 | +43:06:21 | DO | 11.18 | -0.34 |
| 12 | HD 93521 | 10:48:23.4 | +37:34:13 | O9 Vp | 7.04 | -0.27 |
| 13 | G163-50 | 11:07:59.3 | -05:09:10 | DA4 | 13.06 | +0.04 |
| 14 | G163-51 | 11:08:06.3 | -05:13:27 | M6 V | 12.58 | +1.51 |
| 15 | theta Crt | 11:36:41.0 | -09:48:08 | B9.5 Vn | 4.70 | -0.08 |
| 16 | HZ 21 | 12:13:56.3 | +32:56:26 | DO2 | 14.68 | -0.33 |
| 17 | Feige 66 | 12:37:23.4 | +25:04:01 | sdO | 10.50 | -0.28 |
| 18 | Feige 67 | 12:41:51.8 | +17:31:20 | sdO | 11.81 | -0.33 |
| 19 | HZ 44 | 13:23:34.4 | +36:07:22 | sdO | 11.66 | -0.29 |
| 20 | PG 1323-086 | 13:25:39.4 | -08:49:18 | sdB-O | 13.48 | -0.14 |
| 21 | BD+33° 2642 | 15:51:59.0 | +32:57:01 | B2 IV | 10.81 | -0.17 |
| 22 | G153-41 | 16:17:55.4 | -15:35:47 | DA2 | 13.42 | -0.22 |
| 23 | 16 Cyg B | 19:41:52.0 | +50:31:03 | G5 V | 6.20 | +0.66 |
| 24 | BD+28° 4211 see note |
21:51:11.5 | +28:51:49 | Op | 10.51 | -0.34 |
| 25 | G93-48 | 21:52:25.3 | +02:23:32 | DA3 | 12.74 | -0.01 |
| 26 | Feige 110 | 23:19:58.3 | -05:09:56 | DOp | 11.82 | -0.29 |
| Star No. |
Name | RA (2000) |
Dec (2000) |
V | B-V | Spec Type |
|---|---|---|---|---|---|---|
| 27 | 92-507 | 00:56:51 | +01:06 | 11.33 | 0.93 | G8: |
| 28 | 92-508 | 00:56:51 | +01:10 | 11.68 | 0.53 | F8 |
| 29 | 95-52 | 03:54:14 | -00:08 | 9.57 | 0.53 | F7 |
| 30 | 95-86 | 03:52:23 | +00:05 | 14.51 | 1.00 | ... |
| 31 | 95-132 | 03:54:31 | +00:05 | 12.06 | 0.45 | A4 |
| 32 | 95-218 | 03:54:50 | +00:10 | 12.10 | 0.71 | G2 V |
| 33 | 95-233 | 03:55:56 | +00:12 | 11.00 | 0.68 | G2 IV |
| 34 | 95-275 | 03:54:44 | +00:27 | 13.48 | 1.76 | ... |
| 35 | 95-301 | 03:52:41 | +00:31 | 11.22 | 1.29 | G8 III |
| 36 | 95-302 | 03:52:42 | +00:31 | 11.69 | 0.83 | G7: |
| 37 | 95-317 | 03:53:44 | +00:30 | 13.45 | 1.32 | ... |
| 38 | 95-330 | 03:54:31 | +00:29 | 12.17 | 2.00 | ... |
| 39 | 96-736 | 04:52:35 | +00:22 | 11.92 | 0.44 | F2: |
| 40 | 96-737 | 04:52:35 | +00:22 | 11.72 | 1.33 | ... |
| 41 | 98-600 | 06:51:45 | -00:26 | 11.11 | 0.57 | F8 |
| 42 | 98-607 | 06:51:48 | -00:26 | 11.15 | 0.16 | B9 |
| 43 | 98-613 | 06:51:49 | -00:27 | 11.81 | 0.17 | A0 |
| 44 | 98-632 | 06:51:55 | -00:26 | 11.54 | 0.15 | B9 |
| 45 | 99-6 | 07:53:33 | -00:50 | 11.05 | 1.26 | G9: III: |
| 46 | 99-8 | 07:53:34 | -00:52 | 11.53 | 0.76 | G9 IV: |
| 47 | 99-12 | 07:53:42 | -00:49 | 12.37 | 0.46 | F8: |
| 48 | 99-14 | 07:53:45 | -00:49 | 12.54 | 0.88 | G5: |
| 49 | 101-88 | 09:54:42 | -00:52 | 11.25 | 0.97 | G8 III |
| 50 | 101-207 | 09:59:10 | -00:55 | 12.42 | 0.52 | F8 |
| 51 | 101-327 | 09:56:09 | -00:26 | 13.44 | 1.16 | ... |
| 52 | 101-329 | 09:56:19 | -00:26 | 11.99 | 0.64 | G7 V: |
| 53 | 101-330 | 09:56:21 | -00:27 | 13.72 | 0.58 | ... |
| 54 | 101-363 | 09:58:19 | -00:26 | 9.87 | 0.26 | A7 |
| 55 | 101-429 | 09:57:32 | -00:18 | 13.50 | 0.98 | ... |
| 56 | 101-431 | 09:57:37 | -00:18 | 13.68 | 1.25 | ... |
| 57 | 104-335 | 12:42:22 | -00:33 | 11.67 | 0.62 | G2 V |
| 58 | 104-337 | 12:42:28 | -00:34 | 11.22 | 0.77 | K2 V |
| 59 | 104-428 | 12:41:41 | -00:26 | 12.63 | 0.99 | ... |
| 60 | 104-439 | 12:42:13 | -00:30 | 11.33 | 0.79 | G8 III |
| 61 | 104-453 | 12:42:46 | -00:26 | 12.24 | 0.77 | K2 V |
| 62 | 104-454 | 12:42:53 | -00:26 | 11.94 | 0.75 | K2 V |
| 63 | 104-460 | 12:43:03 | -00:28 | 12.89 | 1.29 | ... |
| 64 | 105-595 | 13:39:58 | -00:29 | 11.62 | 0.69 | G8 V |
| 65 | 105-599 | 13:40:03 | -00:28 | 11.70 | 0.62 | G5 V |
| 66 | 105-600 | 13:40:15 | -00:29 | 11.84 | 0.56 | G0 |
| 67 | 107-351 | 15:38:46 | -00:32 | 12.34 | 0.56 | F8 |
| 68 | 107-365 | 15:39:29 | -00:30 | 11.60 | 1.10 | G8 IV: |
| 69 | 107-452 | 15:38:37 | -00:23 | 11.04 | 1.07 | G8 III |
| 70 | 107-456 | 15:38:43 | -00:20 | 12.92 | 0.92 | ... |
| 71 | 107-465 | 15:39:20 | -00:27 | 11.60 | 0.55 | F5 |
| 72 | 107-469 | 15:39:39 | -00:27 | 12.17 | 0.58 | F8 |
| 73 | 107-568 | 15:37:53 | -00:17 | 13.05 | 1.15 | ... |
| 74 | 107-596 | 15:39:03 | -00:14 | 11.39 | 0.56 | F7 |
| 75 | 107-601 | 15:39:14 | -00:13 | 14.65 | 1.41 | ... |
| 76 | 107-602 | 15:39:19 | -00:15 | 12.12 | 0.99 | G9: |
| 77 | 107-619 | 15:39:51 | -00:18 | 12.12 | 0.62 | F8 |
| 78 | 107-626 | 15:40:06 | -00:17 | 13.47 | 1.00 | ... |
| 79 | 107-627 | 15:40:08 | -00:17 | 13.35 | 0.78 | ... |
| 80 | 107-990 | 15:38:00 | +02:19 | 9.56 | 0.49 | F5 |
| 81 | 108-468 | 16:36:54 | -00:33 | 12.07 | 0.69 | G2 V: |
| 82 | 108-475 | 16:37:00 | -00:35 | 11.31 | 1.38 | K0 III |
| 83 | 109-949 | 17:44:13 | -00:02 | 12.83 | 0.81 | G8: |
| 84 | 109-954 | 17:44:15 | -00:02 | 12.44 | 1.30 | ... |
| 85 | 109-956 | 17:44:17 | -00:03 | 14.64 | 1.28 | ... |
| 86 | 109-959 | 17:44:18 | -00:02 | 12.79 | 0.92 | ... |
| 87 | 110-499 | 18:43:07 | +00:28 | 11.74 | 0.99 | B9 |
| 88 | 110-502 | 18:43:10 | +00:28 | 12.33 | 2.33 | ... |
| 89 | 110-503 | 18:43:11 | +00:30 | 11.77 | 0.67 | A0 |
| 90 | 110-506 | 18:43:19 | +00:30 | 11.31 | 0.57 | F8 |
| 91 | 110-507 | 18:43:19 | +00:29 | 12.44 | 1.14 | ... |
| 92 | 111-1925 | 19:37:29 | +00:25 | 12.39 | 0.40 | A0 |
| 93 | 111-1965 | 19:37:42 | +00:27 | 11.42 | 1.71 | K0: |
| 94 | 111-1969 | 19:37:44 | +00:26 | 10.38 | 1.96 | M5 III |
| 95 | 112-805 | 20:42:46 | +00:16 | 12.09 | 0.15 | A1 |
| 96 | 112-810 | 20:42:50 | +00:17 | 10.58 | 1.16 | K0 III |
| 97 | 112-822 | 20:42:55 | +00:15 | 11.55 | 1.03 | G8 III |
| 98 | 113-221 | 21:40:36 | +00:21 | 12.07 | 1.03 | ... |
| 99 | 113-241 | 21:41:09 | +00:26 | 14.35 | 1.34 | ... |
| 100 | 113-260 | 21:41:48 | +00:24 | 12.41 | 0.51 | ... |
| 101 | 113-339 | 21:40:56 | +00:28 | 12.25 | 0.57 | F8 |
| 102 | 113-342 | 21:41:00 | +00:28 | 10.88 | 1.02 | G8 III |
| 103 | 113-442 | 21:40:40 | +00:45 | 9.62 | 1.16 | K2 III |