|
|
|
| Star Designation | RA (2000) | Dec (2000) | V | B-V | U-B | V-R | R-I | V-I |
|---|---|---|---|---|---|---|---|---|
| TPHE A | 00:30:09 | -46:31:22 | 14.651 | 0.793 | 0.380 | 0.435 | 0.405 | 0.841 |
| TPHE B | 00:30:16 | -46:27:55 | 12.334 | 0.405 | 0.156 | 0.262 | 0.271 | 0.535 |
| TPHE C | 00:30:17 | -46:32:34 | 14.376 | -0.298 | -1.217 | -0.148 | -0.211 | -0.360 |
| TPHE D | 00:30:18 | -46:31:11 | 13.118 | 1.551 | 1.871 | 0.849 | 0.810 | 1.663 |
| TPHE E | 00:30:19 | -46:24:36 | 11.630 | 0.443 | -0.103 | 0.276 | 0.283 | 0.564 |
| TPHE F | 00:30:50 | -46:33:33 | 12.474 | 0.855 | 0.532 | 0.492 | 0.435 | 0.926 |
| TPHE G | 00:31:05 | -46:22:43 | 10.442 | 1.546 | 1.915 | 0.934 | 1.085 | 2.025 |
| PG0029+024 | 00:31:50 | +02:38:26 | 15.268 | 0.362 | -0.184 | 0.251 | 0.337 | 0.593 |
| PG0039+049 | 00:42:05 | +05:09:44 | 12.877 | -0.019 | -0.871 | 0.067 | 0.097 | 0.164 |
| 92 309 | 00:53:14 | +00:46:06 | 13.842 | 0.513 | -0.024 | 0.326 | 0.325 | 0.652 |
| 92 235 | 00:53:16 | +00:36:22 | 10.595 | 1.638 | 1.984 | 0.894 | 0.911 | 1.806 |
| 92 322 | 00:53:47 | +00:47:41 | 12.676 | 0.528 | -0.002 | 0.302 | 0.305 | 0.608 |
| 92 245 | 00:54:16 | +00:39:56 | 13.818 | 1.418 | 1.189 | 0.929 | 0.907 | 1.836 |
| 92 248 | 00:54:31 | +00:40:20 | 15.346 | 1.128 | 1.289 | 0.690 | 0.553 | 1.245 |
| 92 249 | 00:54:34 | +00:41:10 | 14.325 | 0.699 | 0.240 | 0.399 | 0.370 | 0.770 |
| 92 250 | 00:54:37 | +00:39:01 | 13.178 | 0.814 | 0.480 | 0.446 | 0.394 | 0.840 |
| 92 330 | 00:54:44 | +00:43:31 | 15.073 | 0.568 | -0.115 | 0.331 | 0.334 | 0.666 |
| 92 252 | 00:54:48 | +00:39:28 | 14.932 | 0.517 | -0.140 | 0.326 | 0.332 | 0.666 |
| 92 253 | 00:54:52 | +00:40:24 | 14.085 | 1.131 | 0.955 | 0.719 | 0.616 | 1.337 |
| 92 335 | 00:55:00 | +00:44:18 | 12.523 | 0.672 | 0.208 | 0.380 | 0.338 | 0.719 |
| 92 339 | 00:55:03 | +00:44:16 | 15.579 | 0.449 | -0.177 | 0.306 | 0.339 | 0.645 |
| 92 342 | 00:55:10 | +00:43:19 | 11.613 | 0.436 | -0.042 | 0.266 | 0.270 | 0.538 |
| 92 188 | 00:55:10 | +00:23:17 | 14.751 | 1.050 | 0.751 | 0.679 | 0.573 | 1.254 |
| 92 409 | 00:55:14 | +00:56:12 | 10.627 | 1.138 | 1.136 | 0.734 | 0.625 | 1.361 |
| 92 410 | 00:55:15 | +01:01:54 | 14.984 | 0.398 | -0.134 | 0.239 | 0.242 | 0.484 |
| 92 412 | 00:55:16 | +01:01:58 | 15.036 | 0.457 | -0.152 | 0.285 | 0.304 | 0.589 |
| 92 259 | 00:55:22 | +00:40:34 | 14.997 | 0.642 | 0.108 | 0.370 | 0.452 | 0.821 |
| 92 345 | 00:55:24 | +00:51:11 | 15.216 | 0.745 | 0.121 | 0.465 | 0.476 | 0.941 |
| 92 347 | 00:55:26 | +00:50:53 | 15.752 | 0.543 | -0.097 | 0.339 | 0.318 | 0.658 |
| 92 260 | 00:55:29 | +00:37:12 | 15.071 | 1.162 | 1.115 | 0.719 | 0.608 | 1.328 |
| 92 348 | 00:55:30 | +00:44:39 | 12.109 | 0.598 | 0.056 | 0.345 | 0.341 | 0.688 |
| 92 417 | 00:55:32 | +00:53:12 | 15.922 | 0.477 | -0.185 | 0.351 | 0.305 | 0.657 |
| 92 263 | 00:55:40 | +00:36:23 | 11.782 | 1.048 | 0.843 | 0.563 | 0.522 | 1.087 |
| 92 497 | 00:55:54 | +01:11:46 | 13.642 | 0.729 | 0.257 | 0.404 | 0.378 | 0.783 |
| 92 498 | 00:55:57 | +01:10:44 | 14.408 | 1.010 | 0.794 | 0.648 | 0.531 | 1.181 |
| 92 500 | 00:55:58 | +01:10:29 | 15.841 | 1.003 | 0.211 | 0.738 | 0.599 | 1.338 |
| 92 425 | 00:55:59 | +00:53:03 | 13.941 | 1.191 | 1.173 | 0.755 | 0.627 | 1.384 |
| 92 501 | 00:56:00 | +01:10:57 | 12.958 | 0.610 | 0.068 | 0.345 | 0.331 | 0.677 |
| 92 426 | 00:56:00 | +00:52:58 | 14.466 | 0.729 | 0.184 | 0.412 | 0.396 | 0.809 |
| 92 355 | 00:56:06 | +00:50:52 | 14.965 | 1.164 | 1.201 | 0.759 | 0.645 | 1.406 |
| 92 427 | 00:56:07 | +01:00:23 | 14.953 | 0.809 | 0.352 | 0.462 | 2.922 | 3.275 |
| 92 502 | 00:56:08 | +01:04:29 | 11.812 | 0.486 | -0.095 | 0.284 | 0.292 | 0.576 |
| 92 430 | 00:56:16 | +00:53:21 | 14.440 | 0.567 | -0.040 | 0.338 | 0.338 | 0.676 |
| 92 276 | 00:56:27 | +00:41:57 | 12.036 | 0.629 | 0.067 | 0.368 | 0.357 | 0.726 |
| 92 282 | 00:56:47 | +00:38:34 | 12.969 | 0.318 | -0.038 | 0.201 | 0.221 | 0.422 |
| 92 508 | 00:56:51 | +01:09:40 | 11.679 | 0.529 | -0.047 | 0.318 | 0.320 | 0.639 |
| 92 507 | 00:56:51 | +01:06:03 | 11.332 | 0.932 | 0.688 | 0.507 | 0.461 | 0.969 |
| 92 364 | 00:56:53 | +00:44:07 | 11.673 | 0.607 | -0.037 | 0.356 | 0.357 | 0.714 |
| 92 433 | 00:56:54 | +01:00:47 | 11.667 | 0.655 | 0.110 | 0.367 | 0.348 | 0.716 |
| 92 288 | 00:57:17 | +00:36:52 | 11.630 | 0.855 | 0.472 | 0.489 | 0.441 | 0.931 |
| F 11 | 01:04:22 | +04:13:37 | 12.065 | -0.240 | -0.978 | -0.120 | -0.142 | -0.261 |
| F 16 | 01:54:08 | -06:42:54 | 12.406 | -0.012 | 0.009 | -0.003 | 0.002 | -0.001 |
| 93 407 | 01:54:37 | +00:53:59 | 11.971 | 0.852 | 0.564 | 0.487 | 0.421 | 0.908 |
| 93 317 | 01:54:38 | +00:43:11 | 11.546 | 0.488 | -0.055 | 0.293 | 0.298 | 0.592 |
| 93 333 | 01:55:05 | +00:45:54 | 12.011 | 0.832 | 0.436 | 0.469 | 0.422 | 0.892 |
| 93 424 | 01:55:26 | +00:56:54 | 11.620 | 1.083 | 0.943 | 0.554 | 0.502 | 1.058 |
| G3 33 | 02:00:09 | +13:04:04 | 12.298 | 1.804 | 1.316 | 1.355 | 1.751 | 3.099 |
| PG0220+132B | 02:23:34 | +13:28:11 | 14.216 | 0.937 | 0.319 | 0.562 | 0.496 | 1.058 |
| PG0220+132 | 02:23:38 | +13:27:42 | 14.760 | -0.132 | -0.922 | -0.050 | -0.120 | -0.170 |
| PG0220+132A | 02:23:39 | +13:27:37 | 15.771 | 0.783 | -0.339 | 0.514 | 0.481 | 0.995 |
| F 22 | 02:30:17 | +05:15:51 | 12.799 | -0.054 | -0.806 | -0.103 | -0.105 | -0.207 |
| PG0231+051E | 02:33:28 | +05:19:48 | 13.804 | 0.677 | 0.201 | 0.390 | 0.369 | 0.757 |
| PG0231+051D | 02:33:33 | +05:19:32 | 14.027 | 1.088 | 1.046 | 0.675 | 0.586 | 1.256 |
| PG0231+051A | 02:33:40 | +05:17:41 | 12.772 | 0.710 | 0.270 | 0.405 | 0.394 | 0.799 |
| PG0231+051C | 02:33:41 | +05:20:22 | 13.702 | 0.671 | 0.114 | 0.399 | 0.385 | 0.783 |
| PG0231+051 | 02:33:41 | +05:18:43 | 16.105 | -0.329 | -1.192 | -0.162 | -0.371 | -0.534 |
| PG0231+051B | 02:33:45 | +05:17:33 | 14.735 | 1.448 | 1.342 | 0.954 | 0.998 | 1.951 |
| F 24 | 02:35:08 | +03:43:57 | 12.411 | -0.203 | -1.169 | 0.090 | 0.364 | 0.451 |
| 94 171 | 02:53:38 | +00:17:34 | 12.659 | 0.817 | 0.304 | 0.480 | 0.483 | 0.964 |
| 94 296 | 02:55:20 | +00:28:29 | 12.255 | 0.750 | 0.235 | 0.415 | 0.387 | 0.803 |
| 94 394 | 02:56:14 | +00:35:25 | 12.273 | 0.545 | -0.047 | 0.344 | 0.330 | 0.676 |
| 94 401 | 02:56:31 | +00:40:21 | 14.293 | 0.638 | 0.098 | 0.389 | 0.369 | 0.759 |
| 94 242 | 02:57:21 | +00:18:54 | 11.728 | 0.301 | 0.107 | 0.178 | 0.184 | 0.362 |
| 94 251 | 02:57:46 | +00:16:18 | 11.204 | 1.219 | 1.281 | 0.659 | 0.587 | 1.247 |
| 94 702 | 02:58:13 | +01:11:09 | 11.594 | 1.418 | 1.621 | 0.756 | 0.673 | 1.430 |
| GD 50 | 03:48:50 | -00:58:33 | 14.063 | -0.276 | -1.191 | -0.145 | -0.180 | -0.325 |
| 95 15 | 03:52:40 | -00:05:03 | 11.302 | 0.712 | 0.157 | 0.424 | 0.385 | 0.809 |
| 95 301 | 03:52:41 | +00:31:37 | 11.216 | 1.290 | 1.296 | 0.692 | 0.620 | 1.311 |
| 95 16 | 03:52:41 | -00:04:47 | 14.313 | 1.306 | 1.322 | 0.796 | 0.676 | 1.472 |
| 95 302 | 03:52:42 | +00:31:37 | 11.694 | 0.825 | 0.447 | 0.471 | 0.420 | 0.891 |
| 95 96 | 03:52:54 | +00:00:37 | 10.010 | 0.147 | 0.072 | 0.079 | 0.095 | 0.174 |
| 95 97 | 03:52:57 | -00:00:01 | 14.818 | 0.906 | 0.380 | 0.522 | 0.546 | 1.068 |
| 95 98 | 03:53:00 | +00:03:11 | 14.448 | 1.181 | 1.092 | 0.723 | 0.620 | 1.342 |
| 95 100 | 03:53:01 | +00:00:31 | 15.633 | 0.791 | 0.051 | 0.538 | 0.421 | 0.961 |
| 95 101 | 03:53:04 | +00:03:12 | 12.677 | 0.778 | 0.263 | 0.436 | 0.426 | 0.863 |
| 95 102 | 03:53:07 | +00:01:28 | 15.622 | 1.001 | 0.162 | 0.448 | 0.618 | 1.065 |
| 95 252 | 03:53:11 | +00:27:37 | 15.394 | 1.452 | 1.178 | 0.816 | 0.747 | 1.566 |
| 95 190 | 03:53:13 | +00:16:39 | 12.627 | 0.287 | 0.236 | 0.195 | 0.220 | 0.415 |
| 95 193 | 03:53:20 | +00:16:50 | 14.338 | 1.211 | 1.239 | 0.748 | 0.616 | 1.366 |
| 95 105 | 03:53:21 | -00:00:01 | 13.574 | 0.976 | 0.627 | 0.550 | 0.536 | 1.088 |
| 95 107 | 03:53:25 | +00:02:36 | 16.275 | 1.324 | 1.115 | 0.947 | 0.962 | 1.907 |
| 95 106 | 03:53:25 | +00:01:40 | 15.137 | 1.251 | 0.369 | 0.394 | 0.508 | 0.903 |
| 95 112 | 03:53:40 | -00:00:54 | 15.502 | 0.662 | 0.077 | 0.605 | 0.620 | 1.227 |
| 95 41 | 03:53:41 | -00:02:12 | 14.060 | 0.903 | 0.297 | 0.589 | 0.585 | 1.176 |
| 95 317 | 03:53:44 | +00:30:06 | 13.449 | 1.320 | 1.120 | 0.768 | 0.708 | 1.476 |
| 95 42 | 03:53:44 | -00:04:08 | 15.606 | -0.215 | -1.111 | -0.119 | -0.180 | -0.300 |
| 95 263 | 03:53:47 | +00:26:57 | 12.679 | 1.500 | 1.559 | 0.801 | 0.711 | 1.513 |
| 95 115 | 03:53:48 | -00:00:29 | 14.680 | 0.836 | 0.096 | 0.577 | 0.579 | 1.157 |
| 95 43 | 03:53:49 | -00:02:42 | 10.803 | 0.510 | -0.016 | 0.308 | 0.316 | 0.624 |
| 95 271 | 03:54:17 | +00:19:08 | 13.669 | 1.287 | 0.916 | 0.734 | 0.717 | 1.453 |
| 95 328 | 03:54:19 | +00:36:47 | 13.525 | 1.532 | 1.298 | 0.908 | 0.868 | 1.776 |
| 95 329 | 03:54:24 | +00:37:25 | 14.617 | 1.184 | 1.093 | 0.766 | 0.642 | 1.410 |
| 95 330 | 03:54:31 | +00:29:23 | 12.174 | 1.999 | 2.233 | 1.166 | 1.100 | 2.268 |
| 95 275 | 03:54:44 | +00:27:37 | 13.479 | 1.763 | 1.740 | 1.011 | 0.931 | 1.944 |
| 95 276 | 03:54:46 | +00:26:13 | 14.118 | 1.225 | 1.218 | 0.748 | 0.646 | 1.395 |
| 95 60 | 03:54:49 | -00:06:46 | 13.429 | 0.776 | 0.197 | 0.464 | 0.449 | 0.914 |
| 95 218 | 03:54:50 | +00:10:26 | 12.095 | 0.708 | 0.208 | 0.397 | 0.370 | 0.767 |
| 95 132 | 03:54:51 | +00:05:40 | 12.064 | 0.448 | 0.300 | 0.259 | 0.287 | 0.545 |
| 95 62 | 03:55:00 | -00:02:36 | 13.538 | 1.355 | 1.181 | 0.742 | 0.685 | 1.428 |
| 95 137 | 03:55:04 | +00:03:51 | 14.440 | 1.457 | 1.136 | 0.893 | 0.845 | 1.737 |
| 95 139 | 03:55:05 | +00:03:32 | 12.196 | 0.923 | 0.677 | 0.562 | 0.476 | 1.039 |
| 95 66 | 03:55:07 | -00:09:12 | 12.892 | 0.715 | 0.167 | 0.426 | 0.438 | 0.864 |
| 95 227 | 03:55:08 | +00:14:54 | 15.779 | 0.771 | 0.034 | 0.515 | 0.552 | 1.067 |
| 95 142 | 03:55:09 | +00:01:39 | 12.927 | 0.588 | 0.097 | 0.371 | 0.375 | 0.745 |
| 95 74 | 03:55:31 | -00:08:54 | 11.531 | 1.126 | 0.686 | 0.600 | 0.567 | 1.165 |
| 95 231 | 03:55:39 | +00:11:02 | 14.216 | 0.452 | 0.297 | 0.270 | 0.290 | 0.560 |
| 95 284 | 03:55:44 | +00:25:27 | 13.669 | 1.398 | 1.073 | 0.818 | 0.766 | 1.586 |
| 95 149 | 03:55:44 | +00:07:23 | 10.938 | 1.593 | 1.564 | 0.874 | 0.811 | 1.685 |
| 95 285 | 03:55:46 | +00:23:59 | 15.561 | 0.937 | 0.703 | 0.607 | 0.602 | 1.210 |
| 95 236 | 03:56:13 | +00:09:02 | 11.491 | 0.736 | 0.162 | 0.420 | 0.411 | 0.831 |
| 96 21 | 04:51:16 | -00:14:30 | 12.182 | 0.490 | -0.004 | 0.299 | 0.297 | 0.598 |
| 96 36 | 04:51:43 | -00:09:51 | 10.591 | 0.247 | 0.118 | 0.134 | 0.136 | 0.271 |
| 96 737 | 04:52:35 | +00:22:50 | 11.716 | 1.334 | 1.160 | 0.733 | 0.695 | 1.428 |
| 96 409 | 04:52:58 | +00:09:26 | 13.778 | 0.543 | 0.042 | 0.340 | 0.340 | 0.682 |
| 96 83 | 04:52:59 | -00:14:22 | 11.719 | 0.179 | 0.202 | 0.093 | 0.097 | 0.190 |
| 96 235 | 04:53:19 | -00:04:42 | 11.140 | 1.074 | 0.898 | 0.559 | 0.510 | 1.068 |
| G97 42 | 05:28:01 | +09:39:07 | 12.443 | 1.639 | 1.259 | 1.171 | 1.485 | 2.655 |
| G102 22 | 05:42:05 | +12:30:14 | 11.509 | 1.621 | 1.134 | 1.211 | 1.590 | 2.800 |
| GD 71 | 05:52:28 | +15:33:15 | 13.032 | -0.249 | -1.107 | -0.137 | -0.164 | -0.302 |
| 97 249 | 05:57:07 | +00:01:34 | 11.733 | 0.648 | 0.100 | 0.369 | 0.353 | 0.723 |
| 97 42 | 05:57:09 | -00:10:50 | 12.448 | 1.626 | 1.208 | 1.160 | 1.485 | 2.641 |
| 97 345 | 05:57:26 | +00:20:48 | 11.608 | 1.655 | 1.680 | 0.928 | 0.844 | 1.771 |
| 97 351 | 05:57:37 | +00:14:05 | 9.781 | 0.202 | 0.096 | 0.124 | 0.141 | 0.264 |
| 97 75 | 05:57:55 | -00:09:07 | 11.483 | 1.872 | 2.100 | 1.047 | 0.952 | 1.999 |
| 97 284 | 05:58:25 | +00:05:35 | 10.788 | 1.363 | 1.087 | 0.774 | 0.725 | 1.500 |
| 97 224 | 05:58:44 | -00:04:50 | 14.085 | 0.910 | 0.341 | 0.553 | 0.547 | 1.102 |
| 98 961 | 06:51:27 | -00:15:15 | 13.089 | 1.283 | 1.003 | 0.701 | 0.662 | 1.362 |
| 98 966 | 06:51:29 | -00:16:05 | 14.001 | 0.469 | 0.357 | 0.283 | 0.331 | 0.613 |
| 98 556 | 06:51:30 | -00:24:30 | 14.137 | 0.338 | 0.126 | 0.196 | 0.243 | 0.437 |
| 98 557 | 06:51:30 | -00:24:45 | 14.780 | 1.397 | 1.072 | 0.755 | 0.741 | 1.494 |
| 98 562 | 06:51:31 | -00:18:37 | 12.185 | 0.522 | -0.002 | 0.305 | 0.303 | 0.607 |
| 98 563 | 06:51:32 | -00:26:04 | 14.162 | 0.416 | -0.190 | 0.294 | 0.317 | 0.610 |
| 98 978 | 06:51:34 | -00:11:06 | 10.572 | 0.609 | 0.094 | 0.349 | 0.322 | 0.671 |
| 98 L1 | 06:51:39 | -00:26:16 | 15.672 | 1.243 | 0.776 | 0.730 | 0.712 | 1.445 |
| 98 L2 | 06:51:40 | -00:20:49 | 15.859 | 1.340 | 1.497 | 0.754 | 0.572 | 1.327 |
| 98 581 | 06:51:40 | -00:25:21 | 14.556 | 0.238 | 0.161 | 0.118 | 0.244 | 0.361 |
| 98 580 | 06:51:40 | -00:26:21 | 14.728 | 0.367 | 0.303 | 0.241 | 0.305 | 0.547 |
| 98 L3 | 06:51:42 | -00:14:56 | 14.614 | 1.936 | 1.837 | 1.091 | 1.047 | 2.142 |
| 98 L4 | 06:51:42 | -00:16:13 | 16.332 | 1.344 | 1.086 | 0.936 | 0.785 | 1.726 |
| 98 1002 | 06:51:43 | -00:15:31 | 14.568 | 0.574 | -0.027 | 0.354 | 0.379 | 0.733 |
| 98 590 | 06:51:43 | -00:21:59 | 14.642 | 1.352 | 0.853 | 0.753 | 0.747 | 1.500 |
| 98 614 | 06:51:49 | -00:20:12 | 15.674 | 1.063 | 0.399 | 0.834 | 0.645 | 1.480 |
| 98 618 | 06:51:50 | -00:20:55 | 12.723 | 2.192 | 2.144 | 1.254 | 1.151 | 2.407 |
| 98 624 | 06:51:52 | -00:19:54 | 13.811 | 0.791 | 0.394 | 0.417 | 0.404 | 0.822 |
| 98 626 | 06:51:53 | -00:20:24 | 14.758 | 1.406 | 1.067 | 0.806 | 0.816 | 1.624 |
| 98 627 | 06:51:53 | -00:21:41 | 14.900 | 0.689 | 0.078 | 0.428 | 0.387 | 0.817 |
| 98 634 | 06:51:56 | -00:20:35 | 14.608 | 0.647 | 0.123 | 0.382 | 0.372 | 0.757 |
| 98 642 | 06:51:59 | -00:21:11 | 15.290 | 0.571 | 0.318 | 0.302 | 0.393 | 0.697 |
| 98 185 | 06:52:02 | -00:26:59 | 10.536 | 0.202 | 0.113 | 0.109 | 0.124 | 0.231 |
| 98 646 | 06:52:03 | -00:20:56 | 15.839 | 1.060 | 1.426 | 0.583 | 0.504 | 1.090 |
| 98 193 | 06:52:04 | -00:26:56 | 10.030 | 1.180 | 1.152 | 0.615 | 0.537 | 1.153 |
| 98 653 | 06:52:05 | -00:17:57 | 9.539 | -0.004 | -0.099 | 0.009 | 0.008 | 0.017 |
| 98 650 | 06:52:05 | -00:19:18 | 12.271 | 0.157 | 0.110 | 0.080 | 0.086 | 0.166 |
| 98 652 | 06:52:05 | -00:21:36 | 14.817 | 0.611 | 0.126 | 0.276 | 0.339 | 0.618 |
| 98 666 | 06:52:10 | -00:23:12 | 12.732 | 0.164 | -0.004 | 0.091 | 0.108 | 0.200 |
| 98 671 | 06:52:12 | -00:18:00 | 13.385 | 0.968 | 0.719 | 0.575 | 0.494 | 1.071 |
| 98 670 | 06:52:12 | -00:18:55 | 11.930 | 1.356 | 1.313 | 0.723 | 0.653 | 1.375 |
| 98 676 | 06:52:14 | -00:18:59 | 13.068 | 1.146 | 0.666 | 0.683 | 0.673 | 1.352 |
| 98 675 | 06:52:14 | -00:19:19 | 13.398 | 1.909 | 1.936 | 1.082 | 1.002 | 2.085 |
| 98 L5 | 06:52:16 | -00:19:17 | 17.800 | 1.900 | -0.100 | 3.100 | 2.600 | 5.800 |
| 98 682 | 06:52:17 | -00:19:20 | 13.749 | 0.632 | 0.098 | 0.366 | 0.352 | 0.717 |
| 98 685 | 06:52:19 | -00:19:57 | 11.954 | 0.463 | 0.096 | 0.290 | 0.280 | 0.570 |
| 98 688 | 06:52:19 | -00:23:12 | 12.754 | 0.293 | 0.245 | 0.158 | 0.180 | 0.337 |
| 98 1082 | 06:52:20 | -00:13:53 | 15.010 | 0.835 | -0.001 | 0.485 | 0.619 | 1.102 |
| 98 1087 | 06:52:21 | -00:15:28 | 14.439 | 1.595 | 1.284 | 0.928 | 0.882 | 1.812 |
| 98 1102 | 06:52:28 | -00:13:21 | 12.113 | 0.314 | 0.089 | 0.193 | 0.195 | 0.388 |
| 98 1112 | 06:52:35 | -00:15:01 | 13.975 | 0.814 | 0.286 | 0.443 | 0.431 | 0.874 |
| 98 1119 | 06:52:37 | -00:14:11 | 11.878 | 0.551 | 0.069 | 0.312 | 0.299 | 0.611 |
| 98 1124 | 06:52:38 | -00:16:12 | 13.707 | 0.315 | 0.258 | 0.173 | 0.201 | 0.373 |
| 98 1122 | 06:52:38 | -00:16:43 | 14.090 | 0.595 | -0.297 | 0.376 | 0.442 | 0.816 |
| 98 724 | 06:52:38 | -00:19:00 | 11.118 | 1.104 | 0.904 | 0.575 | 0.527 | 1.103 |
| 98 733 | 06:52:40 | -00:16:54 | 12.238 | 1.285 | 1.087 | 0.698 | 0.650 | 1.347 |
| RU 149G | 07:24:10 | -00:30:49 | 12.829 | 0.541 | 0.033 | 0.322 | 0.322 | 0.645 |
| RU 149A | 07:24:12 | -00:31:47 | 14.495 | 0.298 | 0.118 | 0.196 | 0.196 | 0.391 |
| RU 149F | 07:24:13 | -00:30:01 | 13.471 | 1.115 | 1.025 | 0.594 | 0.538 | 1.132 |
| RU 149 | 07:24:13 | -00:31:58 | 13.866 | -0.129 | -0.779 | -0.040 | -0.068 | -0.108 |
| RU 149D | 07:24:14 | -00:31:41 | 11.480 | -0.037 | -0.287 | 0.021 | 0.008 | 0.029 |
| RU 149C | 07:24:16 | -00:31:20 | 14.425 | 0.195 | 0.141 | 0.093 | 0.127 | 0.222 |
| RU 149B | 07:24:16 | -00:32:01 | 12.642 | 0.662 | 0.151 | 0.374 | 0.354 | 0.728 |
| RU 149E | 07:24:17 | -00:30:11 | 13.718 | 0.522 | -0.007 | 0.321 | 0.314 | 0.637 |
| RU 152F | 07:29:51 | -02:04:29 | 14.564 | 0.635 | 0.069 | 0.382 | 0.315 | 0.689 |
| RU 152E | 07:29:51 | -02:05:09 | 12.362 | 0.042 | -0.086 | 0.030 | 0.034 | 0.065 |
| RU 152 | 07:29:55 | -02:06:18 | 13.014 | -0.190 | -1.073 | -0.057 | -0.087 | -0.145 |
| RU 152B | 07:29:56 | -02:05:39 | 15.019 | 0.500 | 0.022 | 0.290 | 0.309 | 0.600 |
| RU 152A | 07:29:57 | -02:06:02 | 14.341 | 0.543 | -0.085 | 0.325 | 0.329 | 0.654 |
| RU 152C | 07:29:59 | -02:05:18 | 12.222 | 0.573 | -0.013 | 0.342 | 0.340 | 0.683 |
| RU 152D | 07:30:03 | -02:04:16 | 11.076 | 0.875 | 0.491 | 0.473 | 0.449 | 0.921 |
| 99 438 | 07:55:54 | -00:16:32 | 9.398 | -0.155 | -0.725 | -0.059 | -0.081 | -0.141 |
| 99 447 | 07:56:07 | -00:20:23 | 9.417 | -0.067 | -0.225 | -0.032 | -0.041 | -0.074 |
| 100 241 | 08:52:35 | -00:39:32 | 10.139 | 0.157 | 0.101 | 0.078 | 0.085 | 0.163 |
| 100 162 | 08:53:15 | -00:43:12 | 9.150 | 1.276 | 1.497 | 0.649 | 0.553 | 1.203 |
| 100 267 | 08:53:18 | -00:41:14 | 13.027 | 0.485 | -0.062 | 0.307 | 0.302 | 0.608 |
| 100 269 | 08:53:19 | -00:40:54 | 12.350 | 0.547 | -0.040 | 0.335 | 0.331 | 0.666 |
| 100 280 | 08:53:36 | -00:36:24 | 11.799 | 0.494 | -0.002 | 0.295 | 0.291 | 0.588 |
| 100 394 | 08:53:55 | -00:32:04 | 11.384 | 1.317 | 1.457 | 0.705 | 0.636 | 1.341 |
| PG0918+029D | 09:21:22 | +02:47:33 | 12.272 | 1.044 | 0.821 | 0.575 | 0.535 | 1.108 |
| PG0918+029 | 09:21:28 | +02:46:06 | 13.327 | -0.271 | -1.081 | -0.129 | -0.159 | -0.288 |
| PG0918+029B | 09:21:34 | +02:48:04 | 13.963 | 0.765 | 0.366 | 0.417 | 0.370 | 0.787 |
| PG0918+029A | 09:21:35 | +02:46:23 | 14.490 | 0.536 | -0.032 | 0.325 | 0.336 | 0.661 |
| PG0918+029C | 09:21:42 | +02:46:41 | 13.537 | 0.631 | 0.087 | 0.367 | 0.357 | 0.722 |
| -12 2918 | 09:31:18 | -13:29:20 | 10.067 | 1.501 | 1.166 | 1.067 | 1.318 | 2.385 |
| PG0942-029D | 09:45:10 | -03:05:50 | 13.707 | 0.564 | 0.129 | 0.348 | 0.343 | 0.687 |
| PG0942-029A | 09:45:10 | -03:10:14 | 14.731 | 0.783 | 0.339 | 0.610 | 0.477 | 1.081 |
| PG0942-029B | 09:45:12 | -03:06:54 | 14.108 | 0.525 | 0.085 | 0.368 | 0.333 | 0.697 |
| PG0942-029 | 09:45:12 | -03:09:21 | 14.004 | -0.294 | -1.175 | -0.130 | -0.149 | -0.280 |
| PG0942-029C | 09:45:15 | -03:06:36 | 14.989 | 0.727 | 0.369 | 0.539 | 0.376 | 0.909 |
| 101 315 | 09:54:51 | -00:27:16 | 11.249 | 1.153 | 1.056 | 0.612 | 0.559 | 1.172 |
| 101 316 | 09:54:53 | -00:18:20 | 11.552 | 0.493 | 0.032 | 0.293 | 0.291 | 0.584 |
| 101 L1 | 09:55:30 | -00:21:25 | 16.501 | 0.757 | -0.104 | 0.421 | 0.527 | 0.947 |
| 101 320 | 09:55:34 | -00:22:19 | 13.823 | 1.052 | 0.690 | 0.581 | 0.561 | 1.141 |
| 101 L2 | 09:55:36 | -00:18:36 | 15.770 | 0.602 | 0.082 | 0.321 | 0.304 | 0.625 |
| 101 404 | 09:55:42 | -00:18:09 | 13.459 | 0.996 | 0.697 | 0.530 | 0.500 | 1.029 |
| 101 324 | 09:55:58 | -00:23:02 | 9.742 | 1.161 | 1.148 | 0.591 | 0.519 | 1.110 |
| 101 262 | 09:56:08 | -00:29:36 | 14.295 | 0.784 | 0.297 | 0.440 | 0.387 | 0.827 |
| 101 408 | 09:56:09 | -00:12:28 | 14.785 | 1.200 | 1.347 | 0.718 | 0.603 | 1.321 |
| 101 326 | 09:56:09 | -00:26:56 | 14.923 | 0.729 | 0.227 | 0.406 | 0.375 | 0.780 |
| 101 410 | 09:56:10 | -00:13:50 | 13.646 | 0.546 | -0.063 | 0.298 | 0.326 | 0.623 |
| 101 327 | 09:56:10 | -00:25:37 | 13.441 | 1.155 | 1.139 | 0.717 | 0.574 | 1.290 |
| 101 413 | 09:56:15 | -00:11:44 | 12.583 | 0.983 | 0.716 | 0.529 | 0.497 | 1.025 |
| 101 268 | 09:56:19 | -00:31:43 | 14.380 | 1.531 | 1.381 | 1.040 | 1.200 | 2.237 |
| 101 330 | 09:56:22 | -00:27:07 | 13.723 | 0.577 | -0.026 | 0.346 | 0.338 | 0.684 |
| 101 415 | 09:56:24 | -00:16:40 | 15.259 | 0.577 | -0.008 | 0.346 | 0.350 | 0.695 |
| 101 270 | 09:56:27 | -00:35:31 | 13.711 | 0.554 | 0.055 | 0.332 | 0.306 | 0.637 |
| 101 278 | 09:56:55 | -00:29:26 | 15.494 | 1.041 | 0.737 | 0.596 | 0.548 | 1.144 |
| 101 L3 | 09:56:55 | -00:30:15 | 15.953 | 0.637 | -0.033 | 0.396 | 0.395 | 0.792 |
| 101 281 | 09:57:05 | -00:31:26 | 11.575 | 0.812 | 0.419 | 0.452 | 0.412 | 0.864 |
| 101 L4 | 09:57:08 | -00:31:16 | 16.264 | 0.793 | 0.362 | 0.578 | 0.062 | 0.644 |
| 101 L5 | 09:57:11 | -00:31:25 | 15.928 | 0.622 | 0.115 | 0.414 | 0.305 | 0.720 |
| 101 421 | 09:57:17 | -00:17:05 | 13.180 | 0.507 | -0.031 | 0.327 | 0.296 | 0.623 |
| 101 338 | 09:57:19 | -00:20:47 | 13.788 | 0.634 | 0.024 | 0.350 | 0.340 | 0.691 |
| 101 339 | 09:57:19 | -00:24:48 | 14.449 | 0.850 | 0.501 | 0.458 | 0.398 | 0.857 |
| 101 424 | 09:57:21 | -00:16:14 | 15.058 | 0.764 | 0.273 | 0.429 | 0.425 | 0.855 |
| 101 427 | 09:57:27 | -00:17:04 | 14.964 | 0.805 | 0.321 | 0.484 | 0.369 | 0.854 |
| 101 341 | 09:57:31 | -00:21:40 | 14.342 | 0.575 | 0.059 | 0.332 | 0.309 | 0.641 |
| 101 342 | 09:57:32 | -00:21:37 | 15.556 | 0.529 | -0.065 | 0.339 | 0.419 | 0.758 |
| 101 343 | 09:57:32 | -00:22:42 | 15.504 | 0.606 | 0.094 | 0.396 | 0.338 | 0.734 |
| 101 429 | 09:57:33 | -00:18:05 | 13.496 | 0.980 | 0.782 | 0.617 | 0.526 | 1.143 |
| 101 431 | 09:57:38 | -00:17:39 | 13.684 | 1.246 | 1.144 | 0.808 | 0.708 | 1.517 |
| 101 L6 | 09:57:40 | -00:17:40 | 16.497 | 0.711 | 0.183 | 0.445 | 0.583 | 1.024 |
| 101 207 | 09:57:53 | -00:47:23 | 12.419 | 0.515 | -0.078 | 0.321 | 0.320 | 0.641 |
| 101 363 | 09:58:20 | -00:25:23 | 9.874 | 0.261 | 0.129 | 0.146 | 0.151 | 0.297 |
| GD 108 | 10:00:47 | -07:33:31 | 13.561 | -0.215 | -0.942 | -0.098 | -0.122 | -0.220 |
| G162 66 | 10:33:43 | -11:40:39 | 13.012 | -0.165 | -0.996 | -0.126 | -0.141 | -0.266 |
| G44 27 | 10:36:02 | +05:07:11 | 12.636 | 1.586 | 1.088 | 1.185 | 1.526 | 2.714 |
| PG1034+001 | 10:37:17 | -00:07:25 | 13.228 | -0.365 | -1.274 | -0.155 | -0.203 | -0.359 |
| G163 6 | 10:42:55 | +02:47:22 | 14.706 | 1.550 | 1.228 | 1.090 | 1.384 | 2.478 |
| PG1047+003 | 10:50:03 | -00:00:30 | 13.474 | -0.290 | -1.121 | -0.132 | -0.162 | -0.295 |
| PG1047+003A | 10:50:06 | -00:01:06 | 13.512 | 0.688 | 0.168 | 0.422 | 0.418 | 0.840 |
| PG1047+003B | 10:50:09 | -00:01:58 | 14.751 | 0.679 | 0.172 | 0.391 | 0.371 | 0.764 |
| PG1047+003C | 10:50:18 | -00:00:21 | 12.453 | 0.607 | -0.019 | 0.378 | 0.358 | 0.737 |
| G44 40 | 10:50:54 | +06:48:57 | 11.675 | 1.644 | 1.213 | 1.216 | 1.568 | 2.786 |
| 102 620 | 10:55:06 | -00:48:13 | 10.069 | 1.083 | 1.020 | 0.642 | 0.524 | 1.167 |
| G45 20 | 10:56:38 | +07:02:23 | 13.507 | 2.034 | 1.165 | 1.823 | 2.174 | 4.000 |
| 102 1081 | 10:57:05 | -00:13:04 | 9.903 | 0.664 | 0.255 | 0.366 | 0.333 | 0.698 |
| G163 27 | 10:57:35 | -07:31:23 | 14.338 | 0.288 | -0.548 | 0.206 | 0.210 | 0.417 |
| G163 50 | 11:08:00 | -05:09:26 | 13.059 | 0.035 | -0.688 | -0.085 | -0.072 | -0.159 |
| G163 51 | 11:08:07 | -05:13:47 | 12.576 | 1.506 | 1.228 | 1.084 | 1.359 | 2.441 |
| G10 50 | 11:47:44 | +00:48:55 | 11.153 | 1.752 | 1.318 | 1.294 | 1.673 | 2.969 |
| 103 302 | 11:56:06 | -00:47:54 | 9.861 | 0.368 | -0.056 | 0.228 | 0.237 | 0.465 |
| 103 626 | 11:56:47 | -00:21:47 | 11.836 | 0.413 | -0.057 | 0.262 | 0.274 | 0.535 |
| G12 43 | 12:33:20 | +09:01:08 | 12.467 | 1.846 | 1.085 | 1.530 | 1.944 | 3.479 |
| 104 306 | 12:41:04 | -00:37:15 | 9.370 | 1.592 | 1.666 | 0.832 | 0.762 | 1.591 |
| 104 423 | 12:41:36 | -00:31:18 | 15.602 | 0.630 | 0.050 | 0.262 | 0.559 | 0.818 |
| 104 428 | 12:41:41 | -00:26:30 | 12.630 | 0.985 | 0.748 | 0.534 | 0.497 | 1.032 |
| 104 L1 | 12:41:44 | -00:22:47 | 14.608 | 0.630 | 0.064 | 0.374 | 0.364 | 0.739 |
| 104 430 | 12:41:50 | -00:25:56 | 13.858 | 0.652 | 0.131 | 0.364 | 0.363 | 0.727 |
| 104 325 | 12:42:03 | -00:41:39 | 15.581 | 0.694 | 0.051 | 0.345 | 0.307 | 0.652 |
| 104 330 | 12:42:12 | -00:40:43 | 15.296 | 0.594 | -0.028 | 0.369 | 0.371 | 0.739 |
| 104 440 | 12:42:14 | -00:24:51 | 15.114 | 0.440 | -0.227 | 0.289 | 0.317 | 0.605 |
| 104 237 | 12:42:17 | -00:51:21 | 15.395 | 1.088 | 0.918 | 0.647 | 0.628 | 1.274 |
| 104 L2 | 12:42:19 | -00:35:16 | 16.048 | 0.650 | -0.172 | 0.344 | 0.323 | 0.667 |
| 104 443 | 12:42:20 | -00:25:25 | 15.372 | 1.331 | 1.280 | 0.817 | 0.778 | 1.595 |
| 104 444 | 12:42:20 | -00:32:32 | 13.477 | 0.512 | -0.070 | 0.313 | 0.331 | 0.643 |
| 104 335 | 12:42:21 | -00:33:12 | 11.665 | 0.622 | 0.145 | 0.357 | 0.334 | 0.691 |
| 104 334 | 12:42:21 | -00:40:31 | 13.484 | 0.518 | -0.067 | 0.323 | 0.331 | 0.653 |
| 104 239 | 12:42:23 | -00:46:36 | 13.936 | 1.356 | 1.291 | 0.868 | 0.805 | 1.675 |
| 104 336 | 12:42:25 | -00:40:02 | 14.404 | 0.830 | 0.495 | 0.461 | 0.403 | 0.865 |
| 104 338 | 12:42:31 | -00:38:36 | 16.059 | 0.591 | -0.082 | 0.348 | 0.372 | 0.719 |
| 104 339 | 12:42:34 | -00:41:43 | 15.459 | 0.832 | 0.709 | 0.476 | 0.374 | 0.849 |
| 104 244 | 12:42:35 | -00:45:51 | 16.011 | 0.590 | -0.152 | 0.338 | 0.489 | 0.825 |
| 104 455 | 12:42:52 | -00:24:22 | 15.105 | 0.581 | -0.024 | 0.360 | 0.357 | 0.716 |
| 104 456 | 12:42:53 | -00:32:09 | 12.362 | 0.622 | 0.135 | 0.357 | 0.337 | 0.694 |
| 104 457 | 12:42:54 | -00:28:52 | 16.048 | 0.753 | 0.522 | 0.484 | 0.490 | 0.974 |
| 104 460 | 12:43:03 | -00:28:25 | 12.886 | 1.287 | 1.243 | 0.813 | 0.693 | 1.507 |
| 104 461 | 12:43:06 | -00:32:25 | 9.705 | 0.476 | -0.030 | 0.289 | 0.290 | 0.580 |
| 104 350 | 12:43:14 | -00:33:25 | 13.634 | 0.673 | 0.165 | 0.383 | 0.353 | 0.736 |
| 104 470 | 12:43:22 | -00:30:00 | 14.310 | 0.732 | 0.101 | 0.295 | 0.356 | 0.649 |
| 104 364 | 12:43:46 | -00:34:34 | 15.799 | 0.601 | -0.131 | 0.314 | 0.397 | 0.712 |
| 104 366 | 12:43:53 | -00:34:56 | 12.908 | 0.870 | 0.424 | 0.517 | 0.464 | 0.982 |
| 104 479 | 12:43:55 | -00:32:55 | 16.087 | 1.271 | 0.673 | 0.657 | 0.607 | 1.264 |
| 104 367 | 12:43:58 | -00:33:40 | 15.844 | 0.639 | -0.126 | 0.382 | 0.296 | 0.679 |
| 104 484 | 12:44:20 | -00:31:01 | 14.406 | 1.024 | 0.732 | 0.514 | 0.486 | 1.000 |
| 104 485 | 12:44:23 | -00:30:20 | 15.017 | 0.838 | 0.493 | 0.478 | 0.488 | 0.967 |
| 104 490 | 12:44:33 | -00:25:57 | 12.572 | 0.535 | 0.048 | 0.318 | 0.312 | 0.630 |
| 104 598 | 12:45:17 | -00:16:41 | 11.479 | 1.106 | 1.050 | 0.670 | 0.546 | 1.215 |
| G14 55 | 13:28:22 | -02:21:28 | 11.336 | 1.491 | 1.157 | 1.078 | 1.388 | 2.462 |
| PG1323-085 | 13:25:39 | -08:49:18 | 13.481 | -0.140 | -0.681 | -0.048 | -0.078 | -0.127 |
| PG1323-085A | 13:25:49 | -08:50:24 | 13.591 | 0.393 | -0.019 | 0.252 | 0.252 | 0.506 |
| PG1323-085C | 13:25:50 | -08:48:39 | 14.003 | 0.707 | 0.245 | 0.395 | 0.363 | 0.759 |
| PG1323-085B | 13:25:50 | -08:51:55 | 13.406 | 0.761 | 0.265 | 0.426 | 0.407 | 0.833 |
| PG1323-085D | 13:26:05 | -08:50:36 | 12.080 | 0.587 | 0.005 | 0.346 | 0.335 | 0.684 |
| 105 505 | 13:35:24 | -00:23:47 | 10.270 | 1.422 | 1.218 | 0.910 | 0.861 | 1.771 |
| 105 437 | 13:37:17 | -00:38:05 | 12.535 | 0.248 | 0.067 | 0.136 | 0.143 | 0.279 |
| 105 815 | 13:40:04 | -00:02:19 | 11.453 | 0.385 | -0.237 | 0.267 | 0.291 | 0.560 |
| +2 2711 | 13:42:20 | +01:29:58 | 10.367 | -0.166 | -0.697 | -0.072 | -0.095 | -0.167 |
| 121968 | 13:58:51 | -02:55:38 | 10.254 | -0.186 | -0.908 | -0.073 | -0.098 | -0.172 |
| PG1407-013 | 14:10:26 | -01:30:16 | 13.750 | -0.259 | -1.119 | -0.130 | -0.144 | -0.277 |
| 106 1024 | 14:40:07 | +00:01:31 | 11.599 | 0.332 | 0.085 | 0.196 | 0.195 | 0.390 |
| 106 700 | 14:40:51 | -00:23:50 | 9.785 | 1.362 | 1.582 | 0.728 | 0.641 | 1.370 |
| PG1514+034 | 15:17:14 | +03:10:22 | 13.997 | -0.009 | -0.955 | 0.087 | 0.126 | 0.212 |
| PG1525-071 | 15:28:11 | -07:16:32 | 15.053 | -0.198 | -1.148 | -0.088 | -0.075 | -0.168 |
| PG1525-071D | 15:28:12 | -07:16:38 | 16.301 | 0.564 | 0.305 | 0.411 | 0.346 | 0.757 |
| PG1525-071A | 15:28:13 | -07:15:59 | 13.509 | 0.757 | 0.257 | 0.445 | 0.425 | 0.869 |
| PG1525-071B | 15:28:14 | -07:16:13 | 16.403 | 0.730 | 0.135 | 0.442 | 0.366 | 0.808 |
| PG1525-071C | 15:28:16 | -07:14:26 | 13.530 | 1.109 | 1.130 | 0.590 | 0.513 | 1.104 |
| PG1528+062B | 15:30:40 | +06:01:06 | 11.989 | 0.593 | 0.005 | 0.364 | 0.344 | 0.711 |
| PG1528+062A | 15:30:49 | +06:01:19 | 15.553 | 0.830 | 0.356 | 0.433 | 0.389 | 0.824 |
| PG1528+062 | 15:30:50 | +06:00:51 | 14.767 | -0.252 | -1.091 | -0.111 | -0.182 | -0.296 |
| PG1528+062C | 15:30:56 | +06:00:02 | 13.477 | 0.644 | 0.074 | 0.357 | 0.340 | 0.699 |
| PG1530+057A | 15:33:10 | +05:33:40 | 13.711 | 0.829 | 0.414 | 0.473 | 0.412 | 0.886 |
| PG1530+057 | 15:33:11 | +05:32:22 | 14.211 | 0.151 | -0.789 | 0.162 | 0.036 | 0.199 |
| PG1530+057B | 15:33:18 | +05:33:43 | 12.842 | 0.745 | 0.325 | 0.423 | 0.376 | 0.799 |
| 107 970 | 15:37:25 | +00:18:16 | 10.939 | 1.596 | 1.750 | 1.142 | 1.435 | 2.574 |
| 107 568 | 15:37:52 | -00:17:36 | 13.054 | 1.149 | 0.862 | 0.625 | 0.595 | 1.217 |
| 107 1006 | 15:38:33 | +00:14:04 | 11.712 | 0.766 | 0.279 | 0.442 | 0.421 | 0.863 |
| 107 720 | 15:38:37 | -00:02:42 | 13.121 | 0.599 | 0.088 | 0.374 | 0.355 | 0.731 |
| 107 456 | 15:38:42 | -00:20:05 | 12.919 | 0.921 | 0.589 | 0.537 | 0.478 | 1.015 |
| 107 457 | 15:38:46 | -00:20:33 | 14.910 | 0.792 | 0.350 | 0.494 | 0.469 | 0.964 |
| 107 351 | 15:38:46 | -00:32:24 | 12.342 | 0.562 | -0.005 | 0.351 | 0.358 | 0.708 |
| 107 592 | 15:38:50 | -00:17:28 | 11.847 | 1.318 | 1.380 | 0.709 | 0.647 | 1.357 |
| 107 458 | 15:38:50 | -00:24:45 | 11.676 | 1.214 | 1.189 | 0.667 | 0.602 | 1.274 |
| 107 459 | 15:38:51 | -00:22:49 | 12.284 | 0.900 | 0.427 | 0.525 | 0.517 | 1.045 |
| 107 212 | 15:38:56 | -00:45:48 | 13.383 | 0.683 | 0.135 | 0.404 | 0.411 | 0.818 |
| 107 215 | 15:38:57 | -00:43:24 | 16.046 | 0.115 | -0.082 | -0.032 | -0.475 | -0.511 |
| 107 213 | 15:38:57 | -00:44:32 | 14.262 | 0.802 | 0.261 | 0.531 | 0.509 | 1.038 |
| 107 357 | 15:39:05 | -00:39:29 | 14.418 | 0.675 | 0.025 | 0.416 | 0.421 | 0.840 |
| 107 599 | 15:39:09 | -00:14:46 | 14.675 | 0.698 | 0.243 | 0.433 | 0.438 | 0.869 |
| 107 359 | 15:39:09 | -00:35:49 | 12.797 | 0.580 | -0.124 | 0.379 | 0.381 | 0.759 |
| 107 600 | 15:39:10 | -00:16:07 | 14.884 | 0.503 | 0.049 | 0.339 | 0.361 | 0.700 |
| 107 601 | 15:39:13 | -00:13:44 | 14.646 | 1.412 | 1.265 | 0.923 | 0.835 | 1.761 |
| 107 602 | 15:39:18 | -00:15:47 | 12.116 | 0.991 | 0.585 | 0.545 | 0.531 | 1.074 |
| 107 612 | 15:39:35 | -00:15:24 | 14.256 | 0.896 | 0.296 | 0.551 | 0.530 | 1.081 |
| 107 611 | 15:39:36 | -00:12:54 | 14.329 | 0.890 | 0.455 | 0.520 | 0.447 | 0.968 |
| 107 614 | 15:39:41 | -00:13:28 | 13.926 | 0.622 | 0.033 | 0.361 | 0.370 | 0.732 |
| 107 626 | 15:40:05 | -00:17:46 | 13.468 | 1.000 | 0.728 | 0.600 | 0.527 | 1.126 |
| 107 627 | 15:40:07 | -00:17:40 | 13.349 | 0.779 | 0.226 | 0.465 | 0.454 | 0.918 |
| 107 484 | 15:40:17 | -00:21:31 | 11.311 | 1.237 | 1.291 | 0.664 | 0.577 | 1.240 |
| 107 636 | 15:40:40 | -00:15:12 | 14.873 | 0.751 | 0.121 | 0.432 | 0.465 | 0.896 |
| 107 639 | 15:40:44 | -00:17:29 | 14.197 | 0.640 | -0.026 | 0.399 | 0.404 | 0.803 |
| 107 640 | 15:40:49 | -00:17:06 | 15.050 | 0.755 | 0.092 | 0.511 | 0.506 | 1.017 |
| G153 41 | 16:17:55 | -15:35:52 | 13.422 | -0.205 | -1.133 | -0.135 | -0.154 | -0.290 |
| G138 25 | 16:25:14 | +15:41:15 | 13.513 | 1.419 | 1.265 | 0.883 | 0.796 | 1.685 |
| -12 4523 | 16:30:18 | -12:39:08 | 10.069 | 1.568 | 1.192 | 1.152 | 1.498 | 2.649 |
| PG1633+099 | 16:35:24 | +09:47:45 | 14.397 | -0.192 | -0.974 | -0.093 | -0.116 | -0.212 |
| PG1633+099A | 16:35:26 | +09:47:48 | 15.256 | 0.873 | 0.320 | 0.505 | 0.511 | 1.015 |
| PG1633+099B | 16:35:34 | +09:46:17 | 12.969 | 1.081 | 1.007 | 0.590 | 0.502 | 1.090 |
| PG1633+099C | 16:35:38 | +09:46:11 | 13.229 | 1.134 | 1.138 | 0.618 | 0.523 | 1.138 |
| PG1633+099D | 16:35:40 | +09:46:38 | 13.691 | 0.535 | -0.025 | 0.324 | 0.327 | 0.650 |
| 108 719 | 16:36:11 | -00:25:53 | 12.690 | 1.031 | 0.648 | 0.553 | 0.533 | 1.087 |
| 108 1848 | 16:36:58 | +00:05:36 | 11.738 | 0.559 | 0.073 | 0.331 | 0.325 | 0.657 |
| 108 475 | 16:37:00 | -00:35:01 | 11.309 | 1.380 | 1.462 | 0.744 | 0.665 | 1.409 |
| 108 1863 | 16:37:13 | +00:02:13 | 12.244 | 0.803 | 0.378 | 0.446 | 0.398 | 0.844 |
| 108 551 | 16:37:47 | -00:33:27 | 10.703 | 0.179 | 0.178 | 0.099 | 0.110 | 0.208 |
| 108 1918 | 16:37:50 | -00:00:58 | 11.384 | 1.432 | 1.839 | 0.773 | 0.661 | 1.434 |
| 108 981 | 16:39:17 | -00:25:28 | 12.071 | 0.494 | 0.237 | 0.310 | 0.312 | 0.622 |
| PG1647+056 | 16:50:18 | +05:32:48 | 14.773 | -0.173 | -1.064 | -0.058 | -0.022 | -0.082 |
| WOLF 629 | 16:55:27 | -08:18:53 | 11.759 | 1.677 | 1.256 | 1.185 | 1.525 | 2.715 |
| PG1657+078 | 16:59:32 | +07:43:25 | 15.015 | -0.149 | -0.940 | -0.063 | -0.033 | -0.100 |
| PG1657+078B | 16:59:32 | +07:42:05 | 14.721 | 0.708 | 0.065 | 0.417 | 0.420 | 0.838 |
| PG1657+078A | 16:59:33 | +07:42:19 | 14.033 | 1.069 | 0.730 | 0.573 | 0.539 | 1.113 |
| PG1657+078C | 16:59:35 | +07:42:20 | 15.225 | 0.840 | 0.385 | 0.521 | 0.444 | 0.967 |
| -4 4226 | 17:05:15 | -05:05:05 | 10.071 | 1.415 | 1.085 | 0.970 | 1.141 | 2.113 |
| 109 71 | 17:44:06 | -00:25:22 | 11.493 | 0.323 | 0.153 | 0.186 | 0.223 | 0.410 |
| 109 381 | 17:44:12 | -00:20:55 | 11.730 | 0.704 | 0.225 | 0.428 | 0.435 | 0.861 |
| 109 949 | 17:44:13 | -00:02:51 | 12.828 | 0.806 | 0.363 | 0.500 | 0.517 | 1.020 |
| 109 954 | 17:44:15 | -00:02:39 | 12.436 | 1.296 | 0.956 | 0.764 | 0.731 | 1.496 |
| 109 956 | 17:44:17 | -00:02:54 | 14.639 | 1.283 | 0.858 | 0.779 | 0.743 | 1.525 |
| 109 199 | 17:45:03 | -00:29:51 | 10.990 | 1.739 | 1.967 | 1.006 | 0.900 | 1.904 |
| 109 231 | 17:45:20 | -00:26:13 | 9.332 | 1.462 | 1.593 | 0.785 | 0.704 | 1.492 |
| 109 537 | 17:45:42 | -00:21:57 | 10.353 | 0.609 | 0.227 | 0.376 | 0.392 | 0.768 |
| G21 15 | 18:27:13 | +04:03:05 | 13.889 | 0.092 | -0.598 | -0.039 | -0.030 | -0.069 |
| 110 229 | 18:40:46 | +00:01:28 | 13.649 | 1.910 | 1.391 | 1.198 | 1.155 | 2.356 |
| 110 230 | 18:40:52 | +00:02:01 | 14.281 | 1.084 | 0.728 | 0.624 | 0.596 | 1.218 |
| 110 232 | 18:40:53 | +00:01:35 | 12.516 | 0.729 | 0.147 | 0.439 | 0.450 | 0.889 |
| 110 233 | 18:40:53 | +00:00:28 | 12.771 | 1.281 | 0.812 | 0.773 | 0.818 | 1.593 |
| 110 239 | 18:41:20 | -00:00:08 | 13.858 | 0.899 | 0.584 | 0.541 | 0.517 | 1.060 |
| 110 339 | 18:41:27 | +00:08:04 | 13.607 | 0.988 | 0.776 | 0.563 | 0.468 | 1.036 |
| 110 340 | 18:41:29 | +00:15:00 | 10.025 | 0.303 | 0.127 | 0.170 | 0.182 | 0.353 |
| 110 477 | 18:41:44 | +00:26:19 | 13.988 | 1.345 | 0.715 | 0.850 | 0.857 | 1.707 |
| 110 246 | 18:41:51 | +00:04:58 | 12.706 | 0.586 | -0.129 | 0.381 | 0.410 | 0.790 |
| 110 346 | 18:41:55 | +00:09:37 | 14.757 | 0.999 | 0.752 | 0.697 | 0.646 | 1.345 |
| 110 349 | 18:42:13 | +00:09:52 | 15.095 | 1.088 | 0.668 | 0.503 | -0.059 | 0.477 |
| 110 355 | 18:42:19 | +00:08:02 | 11.944 | 1.023 | 0.504 | 0.652 | 0.727 | 1.378 |
| 110 358 | 18:42:36 | +00:14:39 | 14.430 | 1.039 | 0.418 | 0.603 | 0.543 | 1.150 |
| 110 360 | 18:42:40 | +00:08:48 | 14.618 | 1.197 | 0.539 | 0.715 | 0.717 | 1.432 |
| 110 361 | 18:42:45 | +00:07:42 | 12.425 | 0.632 | 0.035 | 0.361 | 0.348 | 0.709 |
| 110 362 | 18:42:48 | +00:06:04 | 15.693 | 1.333 | 3.919 | 0.918 | 0.885 | 1.803 |
| 110 L1 | 18:42:50 | +00:06:48 | 16.252 | 1.752 | 2.953 | 1.066 | 0.992 | 2.058 |
| 110 266 | 18:42:50 | +00:04:44 | 12.018 | 0.889 | 0.411 | 0.538 | 0.577 | 1.111 |
| 110 364 | 18:42:52 | +00:07:32 | 13.615 | 1.133 | 1.095 | 0.697 | 0.585 | 1.281 |
| 110 365 | 18:42:57 | +00:06:58 | 13.470 | 2.261 | 1.895 | 1.360 | 1.270 | 2.631 |
| 110 157 | 18:42:57 | -00:09:18 | 13.491 | 2.123 | 1.679 | 1.257 | 1.139 | 2.395 |
| 110 496 | 18:43:00 | +00:30:46 | 13.004 | 1.040 | 0.737 | 0.607 | 0.681 | 1.287 |
| 110 273 | 18:43:00 | +00:02:01 | 14.686 | 2.527 | 1.000 | 1.509 | 1.345 | 2.856 |
| 110 497 | 18:43:03 | +00:30:34 | 14.196 | 1.052 | 0.380 | 0.606 | 0.597 | 1.203 |
| 110 280 | 18:43:07 | -00:04:02 | 12.996 | 2.151 | 2.133 | 1.235 | 1.148 | 2.384 |
| 110 499 | 18:43:08 | +00:27:38 | 11.737 | 0.987 | 0.639 | 0.600 | 0.674 | 1.273 |
| 110 502 | 18:43:11 | +00:27:18 | 12.330 | 2.326 | 2.326 | 1.373 | 1.250 | 2.625 |
| 110 504 | 18:43:12 | +00:29:43 | 14.022 | 1.248 | 1.323 | 0.797 | 0.683 | 1.482 |
| 110 503 | 18:43:12 | +00:29:21 | 11.773 | 0.671 | 0.506 | 0.373 | 0.436 | 0.808 |
| 110 506 | 18:43:20 | +00:30:05 | 11.312 | 0.568 | 0.059 | 0.335 | 0.312 | 0.652 |
| 110 507 | 18:43:20 | +00:29:04 | 12.440 | 1.141 | 0.830 | 0.633 | 0.579 | 1.206 |
| 110 290 | 18:43:22 | -00:01:37 | 11.898 | 0.708 | 0.196 | 0.418 | 0.418 | 0.836 |
| 110 441 | 18:43:34 | +00:19:18 | 11.121 | 0.555 | 0.112 | 0.324 | 0.336 | 0.660 |
| 110 311 | 18:43:48 | -00:00:44 | 15.505 | 1.796 | 1.179 | 1.010 | 0.864 | 1.874 |
| 110 312 | 18:43:50 | -00:00:15 | 16.093 | 1.319 | -0.788 | 1.137 | 1.154 | 2.293 |
| 110 450 | 18:43:52 | +00:22:36 | 11.585 | 0.944 | 0.691 | 0.552 | 0.625 | 1.177 |
| 110 316 | 18:43:53 | +00:00:43 | 14.821 | 1.731 | 4.355 | 0.858 | 0.910 | 1.769 |
| 110 315 | 18:43:53 | +00:00:27 | 13.637 | 2.069 | 2.256 | 1.206 | 1.133 | 2.338 |
| 110 319 | 18:43:56 | +00:01:39 | 11.861 | 1.309 | 1.076 | 0.742 | 0.700 | 1.443 |
| 111 775 | 19:37:17 | +00:11:44 | 10.744 | 1.738 | 2.029 | 0.965 | 0.896 | 1.862 |
| 111 773 | 19:37:17 | +00:10:38 | 8.963 | 0.206 | -0.210 | 0.119 | 0.144 | 0.262 |
| 111 1925 | 19:37:29 | +00:24:40 | 12.388 | 0.395 | 0.262 | 0.221 | 0.253 | 0.474 |
| 111 1965 | 19:37:42 | +00:26:30 | 11.419 | 1.710 | 1.865 | 0.951 | 0.877 | 1.830 |
| 111 1969 | 19:37:44 | +00:25:27 | 10.382 | 1.959 | 2.306 | 1.177 | 1.222 | 2.400 |
| 111 2039 | 19:38:05 | +00:31:52 | 12.395 | 1.369 | 1.237 | 0.739 | 0.689 | 1.430 |
| 111 2088 | 19:38:22 | +00:30:40 | 13.193 | 1.610 | 1.678 | 0.888 | 0.818 | 1.708 |
| 111 2093 | 19:38:24 | +00:31:05 | 12.538 | 0.637 | 0.283 | 0.370 | 0.397 | 0.766 |
| 112 595 | 20:41:19 | +00:16:11 | 11.352 | 1.601 | 1.993 | 0.899 | 0.901 | 1.801 |
| 112 704 | 20:42:03 | +00:18:53 | 11.452 | 1.536 | 1.742 | 0.822 | 0.746 | 1.570 |
| 112 223 | 20:42:15 | +00:08:44 | 11.424 | 0.454 | 0.010 | 0.273 | 0.274 | 0.547 |
| 112 250 | 20:42:27 | +00:07:25 | 12.095 | 0.532 | -0.025 | 0.317 | 0.323 | 0.639 |
| 112 275 | 20:42:36 | +00:07:03 | 9.905 | 1.210 | 1.299 | 0.647 | 0.569 | 1.217 |
| 112 805 | 20:42:47 | +00:15:51 | 12.086 | 0.152 | 0.150 | 0.063 | 0.075 | 0.138 |
| 112 822 | 20:42:56 | +00:14:47 | 11.549 | 1.031 | 0.883 | 0.558 | 0.502 | 1.060 |
| MARK A2 | 20:43:54 | -10:45:32 | 14.540 | 0.666 | 0.096 | 0.379 | 0.371 | 0.751 |
| MARK A1 | 20:43:58 | -10:47:11 | 15.911 | 0.609 | -0.014 | 0.367 | 0.373 | 0.740 |
| MARK A | 20:43:59 | -10:47:42 | 13.258 | -0.242 | -1.162 | -0.115 | -0.125 | -0.241 |
| MARK A3 | 20:44:02 | -10:45:39 | 14.818 | 0.938 | 0.651 | 0.587 | 0.510 | 1.098 |
| WOLF 918 | 21:11:30 | -13:08:22 | 10.868 | 1.494 | 1.146 | 0.981 | 1.088 | 2.065 |
| G26 7 | 21:31:16 | -09:47:28 | 12.005 | 1.669 | 1.235 | 1.300 | 1.695 | 2.986 |
| 113 440 | 21:40:35 | +00:41:32 | 11.796 | 0.637 | 0.167 | 0.363 | 0.350 | 0.715 |
| 113 221 | 21:40:37 | +00:20:47 | 12.071 | 1.031 | 0.874 | 0.550 | 0.490 | 1.041 |
| 113 L1 | 21:40:47 | +00:28:19 | 15.530 | 1.343 | 1.180 | 0.867 | 0.723 | 1.594 |
| 113 337 | 21:40:49 | +00:27:42 | 14.225 | 0.519 | -0.025 | 0.351 | 0.331 | 0.682 |
| 113 339 | 21:40:56 | +00:27:44 | 12.250 | 0.568 | -0.034 | 0.340 | 0.347 | 0.687 |
| 113 342 | 21:41:00 | +00:27:21 | 10.878 | 1.015 | 0.696 | 0.537 | 0.513 | 1.050 |
| 113 233 | 21:41:00 | +00:21:47 | 12.398 | 0.549 | 0.096 | 0.338 | 0.322 | 0.661 |
| 113 239 | 21:41:08 | +00:22:19 | 13.038 | 0.516 | 0.051 | 0.318 | 0.327 | 0.647 |
| 113 241 | 21:41:10 | +00:25:37 | 14.352 | 1.344 | 1.452 | 0.897 | 0.797 | 1.683 |
| 113 245 | 21:41:14 | +00:21:38 | 15.665 | 0.628 | 0.112 | 0.396 | 0.318 | 0.716 |
| 113 459 | 21:41:15 | +00:42:50 | 12.125 | 0.535 | -0.018 | 0.307 | 0.313 | 0.623 |
| 113 250 | 21:41:25 | +00:20:28 | 13.160 | 0.505 | -0.003 | 0.309 | 0.316 | 0.626 |
| 113 466 |