-> reboot
reboot



Press any key to stop auto-boot...
 7 6 5 4 3 2 1 0
auto-booting...


boot device          : ln
processor number     : 0 
host name            : esinstb.ucolick.org
file name            : /vx/vw/vxWorks
inet on ethernet (e) : 192.168.5.5:ffffff00
host inet (h)        : 192.168.5.3
user (u)             : kics
flags (f)            : 0x2 
target name (tn)     : esi5cb.ucolick.org
startup script (s)   : /vx/esi5ce/startup.cmd

Attaching network interface ln0... done.
Attaching network interface lo0... done.
Loading... 476728 + 32904 + 24240
Starting at 0x20000...

Attaching network interface ln0... done.
Attaching network interface lo0... done.
Loading symbol table from esinstb.ucolick.org:/vx/vw/vxWorks.sym ...done
 

 ]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]
 ]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]
 ]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]
      ]]]]]]]]]]]  ]]]]     ]]]]]]]]]]       ]]              ]]]]         (R)
 ]     ]]]]]]]]]  ]]]]]]     ]]]]]]]]       ]]               ]]]]            
 ]]     ]]]]]]]  ]]]]]]]]     ]]]]]] ]     ]]                ]]]]            
 ]]]     ]]]]] ]    ]]]  ]     ]]]] ]]]   ]]]]]]]]]  ]]]] ]] ]]]]  ]]   ]]]]]
 ]]]]     ]]]  ]]    ]  ]]]     ]] ]]]]] ]]]]]]   ]] ]]]]]]] ]]]] ]]   ]]]]  
 ]]]]]     ]  ]]]]     ]]]]]      ]]]]]]]] ]]]]   ]] ]]]]    ]]]]]]]    ]]]] 
 ]]]]]]      ]]]]]     ]]]]]]    ]  ]]]]]  ]]]]   ]] ]]]]    ]]]]]]]]    ]]]]
 ]]]]]]]    ]]]]]  ]    ]]]]]]  ]    ]]]   ]]]]   ]] ]]]]    ]]]] ]]]]    ]]]]
 ]]]]]]]]  ]]]]]  ]]]    ]]]]]]]      ]     ]]]]]]]  ]]]]    ]]]]  ]]]] ]]]]]
 ]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]
 ]]]]]]]]]]]]]]]]]]]]]]]]]]]]]       Development System
 ]]]]]]]]]]]]]]]]]]]]]]]]]]]]
 ]]]]]]]]]]]]]]]]]]]]]]]]]]]       VxWorks version 5.2
 ]]]]]]]]]]]]]]]]]]]]]]]]]]       KERNEL: WIND version 2.4
 ]]]]]]]]]]]]]]]]]]]]]]]]]       Copyright Wind River Systems, Inc., 1984-1995

                               CPU: FORCE CPU-5CE.  Processor #0.
                              Memory Size: 0x700000.  BSP version 1.0.

Executing startup script /vx/esi5ce/startup.cmd ...
loginUserAdd "kics","S9deyRSb9S"
value = 0 = 0x0
nfsMount "esinstb.ucolick.org","/vx","/vx"
value = 0 = 0x0
nfsAuthUnixPrompt
machine name:   esinstb.ucolick.org user ID:        2001 group ID:       100 num of groups:  0 value = 0 = 0x0
iam "kics"
value = 0 = 0x0
ifBroadcastSet "ln0", "192.168.5.255"
value = 0 = 0x0
hostAdd "esupvb.ucolick.org","192.168.5.4"
value = 0 = 0x0
hostShow
hostname         inet address       aliases
--------         ------------       -------
esi5cb.ucolick.org 192.168.5.5       
localhost        127.0.0.1         
esinstb.ucolick.org 192.168.5.3       
esupvb.ucolick.org 192.168.5.4       
value = 0 = 0x0
nfsDevShow
device name          file system                                       
-----------          -----------                                       
/vx                  esinstb.ucolick.org:/vx                           
value = 0 = 0x0
cd "/vx/esi5ce"
value = 0 = 0x0
< logo
cd "/vx/kroot/kss/esi/vme/force5ce/vmeinf"
value = 0 = 0x0
<load_vmeinf
ld<sra.o
value = 16631136 = 0xfdc560 = sra.o_bss + 0x8
ld<rccd_vmeinf_msg.o
value = 16631728 = 0xfdc7b0 = sra.o_bss + 0x258
cd ".."
value = 0 = 0x0

cd "/vx/kroot/kss/esi/vme/force5ce/util"
value = 0 = 0x0
< load_util
ld <sleep.o
value = 16580544 = 0xfcffc0 = rccd_vmeinf_msg.o_bss + 0x690
ld <doprnt.o
value = 16581128 = 0xfd0208 = rccd_vmeinf_msg.o_bss + 0x8d8

ld <our_strlib.o
value = 16561184 = 0xfcb420 = our_strlib.o_bss + 0x8
ld <simpl_err.o
value = 16559600 = 0xfcadf0 = simpl_err.o_bss + 0x8
ld <vme_errmsg.o
value = 16558448 = 0xfca970 = vme_errmsg.o_bss + 0x8


cd "/vx/kroot/kss/esi/vme/force5ce/music/load/4.0"
value = 0 = 0x0
<load_music
ld <../../dlib/4.0/logerror.o
value = 16597872 = 0xfd4370
ld <../../dlib/4.0/msgio.o
value = 16599680 = 0xfd4a80 = _msg_err_txt + 0x438

ld <../../dlib/4.0/waitfor.o
value = 16600280 = 0xfd4cd8 = waitfor.o_bss + 0x2d8
ld <../../dlib/4.0/readremote.o
value = 16583664 = 0xfd0bf0 = readremote.o_bss + 0x10
ld <../../traffic/4.0/consock.o
value = 16581760 = 0xfd0480 = rccd_vmeinf_msg.o_bss + 0xb50
ld <../../traffic/4.0/startproc.o
value = 16580104 = 0xfcfe08 = rccd_vmeinf_msg.o_bss + 0x4d8
ld <../../dlib/4.0/tropen.o
value = 16584240 = 0xfd0e30 = readremote.o_bss + 0x250
ld <../../dlib/4.0/bcast.o
value = 16527056 = 0xfc2ed0 = bcast.o_bss + 0x8
ld <../../dlib/4.0/contactpr.o
value = 16586032 = 0xfd1530 = contactpr.o_bss + 0x8

cd "/vx/kroot/kss/esi/vme/force5ce/cserv_common"
value = 0 = 0x0
<load_respond
ld <amsgio.o
value = 16594816 = 0xfd3780 = amsgio.o_bss + 0x318
ld <make_response_pipe.o
value = 16596608 = 0xfd3e80 = make_response_pipe.o_bss + 0x8
ld <respond.o
value = 16597224 = 0xfd40e8 = make_response_pipe.o_bss + 0x270
ld <broadcast.o
value = 16589656 = 0xfd2358 = logerror.o_bss + 0x5b8
ld <delete_hooks.o
value = 16586680 = 0xfd17b8 = contactpr.o_bss + 0x290

cd "/vx/kroot/kss/esi/vme/force5ce/mlog"
value = 0 = 0x0
<load_mlog
ld < mlog_errmsg.o
value = 16551000 = 0xfc8c58 = mlog_errmsg.o_bss + 0x310
ld < mlog_composite.o
value = 16552792 = 0xfc9358 = mlog_errmsg.o_bss + 0xa10
ld < mlog_utl.o
value = 16548368 = 0xfc8210
ld < mlog_start_stop.o
value = 16591464 = 0xfd2a68 = logerror.o_bss + 0xcc8
ld < mlog.o
value = 16334984 = 0xf94088 = mlog_start_stop.o_bss + 0x548
ld < check.o
value = 16328184 = 0xf925f8 = check.o_bss + 0x8

cd "/vx/kroot/kss/esi/vme/force5ce/ldserv"
value = 0 = 0x0
ld<crate_global_init.o
value = 16523456 = 0xfc20c0 = _utb_raw_dac_channel + 0x88

cd "/vx/kroot/kss/esi/vme/force5ce/readccd"
value = 0 = 0x0
<loadreal
ld < single_clidriv.o
value = 16345896 = 0xf96b28 = single_clidriv.o_bss + 0x308
ld < single_driv.o
value = 16347704 = 0xf97238 = single_driv.o_bss + 0x8
ld < twoamp_clidriv.o
value = 16348304 = 0xf97490 = single_driv.o_bss + 0x260
ld < twoamp_driv.o
value = 16524216 = 0xfc23b8 = _utb_raw_dac_channel + 0x380
ld < spiral_clidriv.o
value = 16340776 = 0xf95728 = mlog_composite.o_bss + 0x178
ld < spiral_driv.o
value = 16342584 = 0xf95e38 = spiral_driv.o_bss + 0x8
ld < packdata.o
value = 16522832 = 0xfc1e50 = crate_global_init.o_bss + 0xb0
ld < notserver.o
value = 16333792 = 0xf93be0 = mlog_start_stop.o_bss + 0xa0
ld < globaldefs.o
value = 16590152 = 0xfd2548 = logerror.o_bss + 0x7a8
ld < findconfig.o
value = 16307240 = 0xf8d428 = findconfig.o_bss + 0x8
ld < readconfig.o
value = 16306256 = 0xf8d050 = globaldefs.o_bss + 0x168
ld < initshared.o
value = 16302872 = 0xf8c318 = initshared.o_bss + 0x8
ld < getsrcname.o
value = 16301768 = 0xf8bec8 = readconfig.o_bss + 0xf0
ld < sendwho.o
value = 16298968 = 0xf8b3d8 = sendwho.o_bss + 0x8
ld < findserv.o
value = 16303504 = 0xf8c590 = initshared.o_bss + 0x280
ld < alltime.o
value = 16295400 = 0xf8a5e8 = findserv.o_bss + 0x540
ld < ourdelay.o
value = 16291992 = 0xf89898 = ourdelay.o_bss + 0x8
ld < dmawccd.o
value = 16291176 = 0xf89568 = dmawccd.o_bss + 0x8
ld < vmefree.o
value = 16295872 = 0xf8a7c0 = findserv.o_bss + 0x718
ld < dmawcsr.o
value = 16287136 = 0xf885a0 = dmawcsr.o_bss + 0x8
ld < vmemalloc.o
value = 16286240 = 0xf88220 = vmefree.o_bss + 0x1c0
ld < vmetomadd.o
value = 16283184 = 0xf87630 = vmetomadd.o_bss + 0x8
ld < dmagetcsr.o
value = 16282288 = 0xf872b0 = dmagetcsr.o_bss + 0x8
ld < initdma.o
value = 16287768 = 0xf88818 = dmawcsr.o_bss + 0x280
ld < makeimage.o
value = 16294272 = 0xf8a180 = findserv.o_bss + 0xd8
ld < vmesndmsg.o
value = 16307792 = 0xf8d650 = findconfig.o_bss + 0x230
ld < handletask.o
value = 16343024 = 0xf95ff0 = spiral_driv.o_bss + 0x1c0
ld < stopearly.o
value = 16279960 = 0xf86998 = stopearly.o_bss + 0x8
ld < packandsend.o
value = 16278952 = 0xf865a8 = handletask.o_bss + 0x150
ld < senddata.o
value = 16549000 = 0xfc8488 = twoamp_driv.o_bss + 0x840
ld < initrccd.o
value = 16275448 = 0xf857f8 = initrccd.o_bss + 0x8
ld < handleclimsg.o
value = 16280592 = 0xf86c10 = stopearly.o_bss + 0x280
ld < enddma.o
value = 16271504 = 0xf84890 = enddma.o_bss + 0x8
ld < rccd.o
value = 16272120 = 0xf84af8 = enddma.o_bss + 0x270
<loadcomm
ld < allocccd.o
value = 16313200 = 0xf8eb70 = allocccd.o_bss + 0x8
ld < sendipc.o
value = 16312248 = 0xf8e7b8 = sendipc.o_bss + 0x8
ld < clearfifo.o
value = 16310976 = 0xf8e2c0 = clearfifo.o_bss + 0x8
ld < cleartime.o
value = 16310104 = 0xf8df58 = cleartime.o_bss + 0x8
ld < getimage.o
value = 16309208 = 0xf8dbd8 = getimage.o_bss + 0x8
ld < rcvmsg.o
value = 16267136 = 0xf83780 = rccd.o_bss + 0x7c0
ld < sendmsg.o
value = 16266536 = 0xf83528 = sendmsg.o_bss + 0x8
ld < settime.o
value = 16265664 = 0xf831c0 = settime.o_bss + 0x8
<loadtest
ld < fakeim.o
value = 16547160 = 0xfc7d58 = twoamp_driv.o_bss + 0x110
ld < loopim.o
value = 16553456 = 0xfc95f0 = loopim.o_bss + 0x8
ld < normim.o
value = 16552192 = 0xfc9100 = normim.o_bss + 0x8
ld < testmsgdef.o
value = 16595448 = 0xfd39f8 = _trsock + 0x578
ld < getimparam.o
value = 16511568 = 0xfbf250
ld < vxtgetim.o
value = 16254744 = 0xf80718
ld < vxtsendmsg.o
value = 16254080 = 0xf80480 = vxtsendmsg.o_bss + 0x8
ld < read_ccd.o
value = 16253232 = 0xf80130 = read_ccd.o_bss + 0x8
ld < looptest.o
value = 16252168 = 0xf7fd08 = looptest.o_bss + 0x8


cd "/vx/kroot/kss/esi/vme/force5ce/ldserv"
value = 0 = 0x0
<load_ldserv
ld<vmemsgxchng.o
value = 16260680 = 0xf81e48 = vmemsgxchng.o_bss + 0x310
ld<vmemsgsend.o
value = 16257176 = 0xf81098 = vmemsgsend.o_bss + 0x8
ld<rccdreset.o
value = 16255352 = 0xf80978 = vxtsendmsg.o_bss + 0x500
ld<rccdkill.o
value = 16315944 = 0xf8f628 = rccdkill.o_bss + 0x8
ld<shell/lda.o
value = 16314960 = 0xf8f250 = lda.o_bss + 0x8
ld<shell/tb_com.o
value = 16242928 = 0xf7d8f0 = tb_com.o_bss + 0x8
ld<shell/vm_com.o
value = 16241888 = 0xf7d4e0 = vm_com.o_bss + 0x8
ld<tb_comint.o
value = 16240504 = 0xf7cf78 = tb_comint.o_bss + 0x8
ld<vm_comint.o
value = 16239208 = 0xf7ca68 = vm_comint.o_bss + 0x8
ld<give_ccd_cib.o
value = 16237912 = 0xf7c558 = give_ccd_cib.o_bss + 0x8
ld<grab_ccd_cib.o
value = 16236240 = 0xf7bed0 = grab_ccd_cib.o_bss + 0x8
ld<dsp_mem_wr.o
value = 16234368 = 0xf7b780 = dsp_mem_wr.o_bss + 0x8
ld<dsp_mem_rd.o
value = 16232848 = 0xf7b190 = dsp_mem_rd.o_bss + 0x8
ld<util_mem_wr.o
value = 16231448 = 0xf7ac18 = util_mem_wr.o_bss + 0x8
ld<util_mem_rd.o
value = 16229888 = 0xf7a600 = util_mem_rd.o_bss + 0x8
ld<get_dsp_data.o
value = 16228488 = 0xf7a088 = get_dsp_data.o_bss + 0x8
ld<put_dsp_data.o
value = 16226576 = 0xf79910 = put_dsp_data.o_bss + 0x8
ld<dsp_vof.o
value = 16224848 = 0xf79250 = dsp_vof.o_bss + 0x8
ld<dsp_hgn.o
value = 16222992 = 0xf78b10 = dsp_hgn.o_bss + 0x8
ld<dsp_lgn.o
value = 16221472 = 0xf78520 = dsp_lgn.o_bss + 0x8
ld<dsp_sar.o
value = 16219968 = 0xf77f40 = dsp_sar.o_bss + 0x8
ld<dsp_sal.o
value = 16218464 = 0xf77960 = dsp_sal.o_bss + 0x8
ld<dsp_brl.o
value = 16216960 = 0xf77380 = dsp_brl.o_bss + 0x8
ld<dsp_zer.o
value = 16215448 = 0xf76d98 = dsp_zer.o_bss + 0x8
ld<dsp_sbv.o
value = 16213944 = 0xf767b8 = dsp_sbv.o_bss + 0x8
ld<dsp_rad.o
value = 16212432 = 0xf761d0 = dsp_rad.o_bss + 0x8
ld<dsp_idl.o
value = 16210928 = 0xf75bf0 = dsp_idl.o_bss + 0x8
ld<dsp_atb.o
value = 16209424 = 0xf75610 = dsp_atb.o_bss + 0x8
ld<dsp_stp.o
value = 16207928 = 0xf75038 = dsp_stp.o_bss + 0x8
ld<dsp_clr.o
value = 16206424 = 0xf74a58 = dsp_clr.o_bss + 0x8
ld<dsp_rdc.o
value = 16204928 = 0xf74480 = dsp_rdc.o_bss + 0x8
ld<dsp_osh.o
value = 16203384 = 0xf73e78 = dsp_osh.o_bss + 0x8
ld<dsp_csh.o
value = 16201872 = 0xf73890 = dsp_csh.o_bss + 0x8
ld<vmeinf_rdc.o
value = 16200328 = 0xf73288 = vmeinf_rdc.o_bss + 0x8
ld<vmeinf_abr.o
value = 16198712 = 0xf72c38 = vmeinf_abr.o_bss + 0x8
ld<vmeinf_mem_wr.o
value = 16197200 = 0xf72650 = vmeinf_mem_wr.o_bss + 0x8
ld<vmeinf_mem_rd.o
value = 16195600 = 0xf72010 = vmeinf_mem_rd.o_bss + 0x8
ld<vmeinf_readout.o
value = 16262472 = 0xf82548 = vmeinf_readout.o_bss + 0x8
ld<vmeinf_test.o
value = 16263088 = 0xf827b0 = vmeinf_readout.o_bss + 0x270
ld<vme_rdpix.o
value = 16189400 = 0xf707d8 = vme_rdpix.o_bss + 0x8
ld<vme_zero.o
value = 16188576 = 0xf704a0 = vme_zero.o_bss + 0x8
ld<vme_init.o
value = 16187480 = 0xf70058 = vme_init.o_bss + 0x8
ld<get_ccd_dims.o
value = 16186528 = 0xf6fca0 = get_ccd_dims.o_bss + 0x8
ld<broadcast_sender.o
value = 16191712 = 0xf710e0 = vmeinf_test.o_bss + 0x90
ld<broadcast_ccd_digital_inputs.o
value = 16193504 = 0xf717e0 = vmeinf_test.o_bss + 0x790
ld<broadcast_ccd_ints.o
value = 16181912 = 0xf6ea98 = broadcast_ccd_ints.o_bss + 0x190
ld<s_set_raw_utb_dac_chan.o
value = 16182512 = 0xf6ecf0 = broadcast_ccd_ints.o_bss + 0x3e8
ld<s_show_raw_utb_dac_chan.o
value = 16174008 = 0xf6cbb8 = s_show_raw_utb_dac_chan.o_bss + 0x8
ld<s_show_raw_utb_adc_chan.o
value = 16171592 = 0xf6c248 = s_show_raw_utb_adc_chan.o_bss + 0x8
ld<s_show_raw_utb_target_chan.o
value = 16168904 = 0xf6b7c8 = s_show_raw_utb_target_chan.o_bss + 0x8
ld<s_show_utb_dig_input.o
value = 16177280 = 0xf6d880 = s_set_raw_utb_dac_chan.o_bss + 0x538
ld<s_show_utb_dig_output.o
value = 16165584 = 0xf6aad0 = s_show_utb_dig_input.o_bss + 0x538
ld<s_set_utb_dig_output.o
value = 16161312 = 0xf69a20 = s_show_utb_dig_output.o_bss + 0x538
ld<s_set_utb_dig_pulse.o
value = 16157072 = 0xf68990 = s_set_utb_dig_output.o_bss + 0x538
ld<s_set_raw_utb_target_chan.o
value = 16152448 = 0xf67780 = s_set_utb_dig_pulse.o_bss + 0x530
ld<s_fastwipe.o
value = 16148336 = 0xf66770 = s_set_raw_utb_target_chan.o_bss + 0x540
ld<read_ccd1.o
value = 16144256 = 0xf65780 = s_fastwipe.o_bss + 0x540
ld<read_ccd2.o
value = 16140224 = 0xf647c0 = read_ccd1.o_bss + 0x540
ld<read_ccd.o
value = 16134520 = 0xf63178 = read_ccd2.o_bss + 0x540
ld<s_cshutter.o
value = 16128400 = 0xf61990 = read_ccd.o_bss + 0x540
ld<s_set_time.o
value = 16116088 = 0xf5e978 = s_set_time.o_bss + 0x8
ld<s_set_preline.o
value = 16129032 = 0xf61c08 = s_set_preline.o_bss + 0x2f8
ld<s_set_preflush.o
value = 16116688 = 0xf5ebd0 = s_set_time.o_bss + 0x260
ld<s_set_postline.o
value = 16140856 = 0xf64a38 = read_ccd1.o_bss + 0x7b8
ld<s_set_overflush.o
value = 16138952 = 0xf642c8 = read_ccd1.o_bss + 0x48
ld<s_set_prepix.o
value = 16142960 = 0xf65270 = s_fastwipe.o_bss + 0x30
ld<s_set_postpix.o
value = 16153096 = 0xf67a08 = s_set_postpix.o_bss + 0x538
ld<s_set_keepprepix.o
value = 16157712 = 0xf68c10 = s_set_utb_dig_output.o_bss + 0x7b8
ld<s_set_eraseline.o
value = 16155944 = 0xf68528 = s_set_utb_dig_output.o_bss + 0xd0
ld<s_set_autoread.o
value = 16160208 = 0xf695d0 = s_show_utb_dig_output.o_bss + 0xe8
ld<s_set_autoshut.o
value = 16164400 = 0xf6a630 = s_show_utb_dig_input.o_bss + 0x98
ld<s_set_autoeras.o
value = 16176160 = 0xf6d420 = s_set_raw_utb_dac_chan.o_bss + 0xd8
ld<s_set_binning.o
value = 16107632 = 0xf5c870 = s_set_binning.o_bss + 0x8
ld<s_set_erasecnt.o
value = 16109400 = 0xf5cf58 = s_set_erasecnt.o_bss + 0x8
ld<s_set_erase.o
value = 16110016 = 0xf5d1c0 = s_set_erasecnt.o_bss + 0x270
ld<s_set_window.o
value = 16100104 = 0xf5ab08 = s_set_window.o_bss + 0x8
ld<s_set_ccdgain.o
value = 16097328 = 0xf5a030 = s_set_ccdgain.o_bss + 0x8
ld<s_set_redxflip.o
value = 16104928 = 0xf5bde0 = s_set_redxflip.o_bss + 0x8
ld<s_set_abfreq.o
value = 16105544 = 0xf5c048 = s_set_redxflip.o_bss + 0x270
ld<s_set_voffset0.o
value = 16095184 = 0xf597d0 = s_set_voffset0.o_bss + 0x8
ld<s_set_voffset1.o
value = 16135152 = 0xf633f0 = s_set_preflush.o_bss + 0x2f8
ld<s_set_voffset2.o
value = 16091448 = 0xf58938 = s_set_voffset2.o_bss + 0x8
ld<s_set_voffset3.o
value = 16095824 = 0xf59a50 = s_set_voffset0.o_bss + 0x288
ld<s_set_mppmode.o
value = 16088360 = 0xf57d28 = s_set_mppmode.o_bss + 0x8
ld<s_set_numamps.o
value = 16087136 = 0xf57860 = s_set_voffset3.o_bss + 0x78
ld<s_set_amplist.o
value = 16083488 = 0xf56a20 = s_set_amplist.o_bss + 0x8
ld<s_set_antiblm.o
value = 16085264 = 0xf57110 = s_set_amplist.o_bss + 0x6f8
ld<s_set_ccdspeed.o
value = 16081464 = 0xf56238 = s_set_ccdspeed.o_bss + 0x8
ld<s_show_time.o
value = 16082080 = 0xf564a0 = s_set_ccdspeed.o_bss + 0x270
ld<s_show_preline.o
value = 16075672 = 0xf54b98 = s_show_preline.o_bss + 0x8
ld<s_show_preflush.o
value = 16074704 = 0xf547d0 = s_show_preflush.o_bss + 0x8
ld<s_show_postline.o
value = 16073736 = 0xf54408 = s_show_postline.o_bss + 0x8
ld<s_show_overflush.o
value = 16072768 = 0xf54040 = s_show_overflush.o_bss + 0x8
ld<s_show_prepix.o
value = 16077448 = 0xf55288 = s_show_prepix.o_bss + 0x8
ld<s_show_postpix.o
value = 16078048 = 0xf554e0 = s_show_prepix.o_bss + 0x260
ld<s_show_keepprepix.o
value = 16068864 = 0xf53100 = s_show_keepprepix.o_bss + 0x8
ld<s_show_eraseline.o
value = 16067896 = 0xf52d38 = s_show_eraseline.o_bss + 0x8
ld<s_show_etime.o
value = 16071168 = 0xf53a00 = s_show_etime.o_bss + 0x8
ld<s_show_autoeras.o
value = 16071768 = 0xf53c58 = s_show_etime.o_bss + 0x260
ld<s_show_autoread.o
value = 16063928 = 0xf51db8 = s_show_autoread.o_bss + 0x8
ld<s_show_autoshut.o
value = 16062896 = 0xf519b0 = s_show_autoshut.o_bss + 0x8
ld<s_show_cshutter.o
value = 16061856 = 0xf515a0 = s_show_cshutter.o_bss + 0x8
ld<s_show_binning.o
value = 16060816 = 0xf51190 = s_show_binning.o_bss + 0x8
ld<s_show_erasecnt.o
value = 16059576 = 0xf50cb8 = s_show_erasecnt.o_bss + 0x8
ld<s_show_window.o
value = 16066296 = 0xf526f8 = s_show_window.o_bss + 0x8
ld<s_show_ccdgain.o
value = 16066896 = 0xf52950 = s_show_window.o_bss + 0x260
ld<s_show_redxflip.o
value = 16055232 = 0xf4fbc0 = s_show_redxflip.o_bss + 0x8
ld<s_show_abfreq.o
value = 16057536 = 0xf504c0 = s_show_abfreq.o_bss + 0x8
ld<s_show_voffset0.o
value = 16058136 = 0xf50718 = s_show_abfreq.o_bss + 0x260
ld<s_show_voffset1.o
value = 16051032 = 0xf4eb58 = s_show_voffset1.o_bss + 0x8
ld<s_show_voffset2.o
value = 16050064 = 0xf4e790 = s_show_voffset2.o_bss + 0x8
ld<s_show_voffset3.o
value = 16048656 = 0xf4e210 = s_show_voffset3.o_bss + 0x8
ld<s_show_mppmode.o
value = 16047320 = 0xf4dcd8 = s_show_mppmode.o_bss + 0x8
ld<s_show_numamps.o
value = 16046032 = 0xf4d7d0 = s_show_numamps.o_bss + 0x8
ld<s_show_amplist.o
value = 16044744 = 0xf4d2c8 = s_show_amplist.o_bss + 0x8
ld<s_show_antiblm.o
value = 16043320 = 0xf4cd38 = s_show_antiblm.o_bss + 0x8
ld<s_show_ccdspeed.o
value = 16042080 = 0xf4c860 = s_show_ccdspeed.o_bss + 0x8
ld<subint_init.o
value = 16053336 = 0xf4f458 = s_show_voffset0.o_bss + 0x540
ld<s_set_nsubint.o
value = 16040040 = 0xf4c068 = s_set_nsubint.o_bss + 0x8
ld<s_set_rowshift.o
value = 16040640 = 0xf4c2c0 = s_set_nsubint.o_bss + 0x260
ld<s_show_nsubint.o
value = 16052288 = 0xf4f040 = s_show_voffset0.o_bss + 0x128
ld<s_show_rowshift.o
value = 16033936 = 0xf4a890 = s_show_rowshift.o_bss + 0x8
ld<s_expose.o
value = 16035712 = 0xf4af80 = s_show_rowshift.o_bss + 0x6f8
ld<s_abortex.o
value = 16032336 = 0xf4a250 = s_expose.o_bss + 0x540
ld<s_show_abortex.o
value = 16025224 = 0xf48688 = s_show_abortex.o_bss + 0x8
ld<s_stopex.o
value = 16025840 = 0xf488f0 = s_show_abortex.o_bss + 0x270
ld<s_pause.o
value = 16031240 = 0xf49e08 = s_expose.o_bss + 0xf8
ld<s_resume.o
value = 16036344 = 0xf4b1f8 = s_show_rowshift.o_bss + 0x970
ld<read_temperature.o
value = 16021072 = 0xf47650 = read_temperature.o_bss + 0x8
ld<s_show_tempdet.o
value = 16020096 = 0xf47280 = s_pause.o_bss + 0x168
ld<server_table.o
value = 16015928 = 0xf46238 = server_table.o_bss + 0x8
ld<broadcast_ccd_analog_targets.o
value = 16016520 = 0xf46488 = server_table.o_bss + 0x258
ld<broadcast_ccd_analog_outputs.o
value = 16032888 = 0xf4a478 = s_expose.o_bss + 0x768
ld<broadcast_ccd_analog_inputs.o
value = 16053968 = 0xf4f6d0 = s_show_voffset0.o_bss + 0x7b8
ld<broadcast_ccd_array_ints.o
value = 16006616 = 0xf43dd8 = broadcast_ccd_array_ints.o_bss + 0xa0
ld<broadcast_ccd_digital_outputs.o
value = 16004456 = 0xf43568 = broadcast_ccd_digital_outputs.o_bss + 0x38
ld<ccdClock.o
value = 16001528 = 0xf429f8 = ccdClock.o_bss + 0x8
ld<vmeinf_hwreset.o
value = 16012296 = 0xf45408 = vmeinf_hwreset.o_bss + 0x8
cd "shell"
value = 0 = 0x0
<load_dsp
ld<udsp_mem_rd.o
value = 16322200 = 0xf90e98 = udsp_mem_rd.o_bss + 0x2f0
ld<udsp_mem_wr.o
value = 16320048 = 0xf90630 = udsp_mem_wr.o_bss + 0x8
ld<udspd.o
value = 16324008 = 0xf915a8 = udspd.o_bss + 0x18
ld<udspm.o
value = 16321624 = 0xf90c58 = udsp_mem_rd.o_bss + 0xb0
ld<ub_com.o
value = 16324608 = 0xf91800 = udspd.o_bss + 0x270
ld<dspm.o
value = 16317536 = 0xf8fc60 = ub_com.o_bss + 0xa0
ld<dspd.o
value = 16011168 = 0xf44fa0 = broadcast_ccd_analog_targets.o_bss + 0x158
ld<tdl.o
value = 15986480 = 0xf3ef30 = tdl.o_bss + 0x8
ld<idl.o
value = 15985384 = 0xf3eae8 = idl.o_bss + 0x8
ld<sbv.o
value = 15984136 = 0xf3e608 = sbv.o_bss + 0x8
ld<lgn.o
value = 15982808 = 0xf3e0d8 = lgn.o_bss + 0x8
ld<hgn.o
value = 15981480 = 0xf3dba8 = hgn.o_bss + 0x8
ld<adelay.o
value = 15990224 = 0xf3fdd0 = adelay.o_bss + 0x8
ld<vmeinfd.o
value = 16012856 = 0xf45638 = vmeinf_hwreset.o_bss + 0x238
ld<vmeinfm.o
value = 15979520 = 0xf3d400 = vmeinfm.o_bss + 0x8
ld<udin.o
value = 15980136 = 0xf3d668 = vmeinfm.o_bss + 0x270
ld<udout.o
value = 15973696 = 0xf3bd40 = udout.o_bss + 0x8

cd "/vx/kroot/kss/esi/vme/force5ce/cserv_common"
value = 0 = 0x0
<load_cserv
ld <delete_hooks.o
value = 16248864 = 0xf7f020 = delete_hooks.o_bss + 0x318

ld <copy_music_message.o
value = 16250656 = 0xf7f720 = copy_music_message.o_bss + 0x8
ld <service_request.o
value = 16248248 = 0xf7edb8 = delete_hooks.o_bss + 0xb0
ld <cserv.o
value = 16246552 = 0xf7e718 = service_request.o_bss + 0x548

pipeDrv
value = 0 = 0x0
set_mlog_lfile( "/vx/esi5ce/logs/mlog_log")
"mlog_composite.c",line 1624: 0: New mlog logfile set.
value = 0 = 0x0
make_response_pipe
value = 0 = 0x0
make_mlog_pipes
value = 0 = 0x0
startup_mlog ("STDOUT")
value = 0 = 0x0
set_mlog_dest ("DBG W0 W1 W2 E0 E1 E2 ST RPT", "DEL", "STDERR")
value = 0 = 0x0
set_mlog_dest     ("W0 W1 W2 E0 E1 E2 ST RPT", "ADD", "STDOUT")
value = 0 = 0x0

crate_global_init
value = 0 = 0x0

taskDelay(3)
value = 0 = 0x0

taskSpawn("cserv",100,0x19,100000,cserv,"e_ccd","/vx/esi5ce/logs/music_log")
value = 15173760 = 0xe78880

taskSpawn("ccdClock",90,0x19,40000,ccdClock)tropen
value = 15073272 = 0xe5fff8

taskDelay(3): our host = 
esi5cb.ucolick.org.
tropen:  remote host = evalue = supvb.ucolic0k.org = 0x0

taskSpawn("rccd",150,0x1d,20000,rccd,"/vx/esi5ce/esi.conf")

value = 15015072 = 0xe51ca0
startproc: parametetaskDelay(180)r host
name = esupvb.ucolick.orgConfiguration fil
e read, return valustartproc: gethostname returned e is esi5cb.ucolick.org0

We have 1 controllers
Allocated socket 17
Broadcasts enabled
Socket successfully assigned
Got network configuration
Broadcast message sent on ln0
Broadcast not sent on lo0
All timeouts cleared
Using 192.168.5.3 as my server
value = 0 = 0x0

vmeinf_hwreset
Resetting VMEINF-2 by writing 0 to 6efff004
value = 0 = 0x0interrupt: Unknown level 15 Interrupt!

taskDelay(60)
value = 0 = 0x0

vmeinf_hwreset
Resetting VMEINF-2 by writing 0 to 6efff004
value = 0 = 0x0
taskDelay(60)
value = 0 = 0x0

vm_com 0,"THR"
msg size = 2 words.  reply size = 2 words
msg = 0X102 0X54544852
reply = 0X10002 0X444f4e
value = 0 = 0x0
taskDelay(60)
startproc: SOCK_CONNECT succeeded; msgaddr = 16778217
value = 0 = 0x0

vm_com 0,"THR"
msg size = 2 words.  reply size = 2 words
msg = 0X102 0X54544852
reply = 0X10002 0X444f4e
value = 0 = 0x0
taskDelay(60)
value = 0 = 0x0

get_ccd_dims( 0 )

	get_ccd_dims: CCD has changed dimensions from 0 rows by 0 cols to 4096 rows by 2048 cols
value = 1 = 0x1
taskDelay(15)
value = 0 = 0x0

cd "/vx/kroot/kss/esi/vme/force5ce/vmeinf/lick"
value = 0 = 0x0
ld < tim_download.o
value = 15970216 = 0xf3afa8 = _sfp + 0x80
ld < tim_verify.o
value = 16247176 = 0xf7e988 = service_request.o_bss + 0x7b8
ld < vme_download.o
value = 16245600 = 0xf7e360 = _sline + 0x188
ld < vme_verify.o
value = 16243952 = 0xf7dcf0 = tb_com.o_bss + 0x408
ld < util_download.o
value = 16243432 = 0xf7dae8 = tb_com.o_bss + 0x200
ld < util_verify.o
value = 14853008 = 0xe2a390 = util_verify.o_bss + 0x690
ld < startup.o
value = 14845856 = 0xe287a0 = startup.o_bss + 0x8

cd "/vx/kroot/kss/esi/vme/force5ce/ldserv"
value = 0 = 0x0
ld<esi_control_dewar_temp.o
value = 15996800 = 0xf41780 = esi_control_dewar_temp.o_bss + 0x318
ld<broadcast_monitor.o
value = 15998608 = 0xf41e90 = broadcast_monitor.o_bss + 0x8

cd "/vx/esi5ce"
value = 0 = 0x0
 
taskDelay(60)
value = 0 = 0x0
 
startup("/vx/esi5ce/dsp",0)
Sending hardware reset to VMEINF board
Resetting VMEINF-2 by writing 0 to 6efff004
Sending hardware reset to TIMING board
msg size = 2 words.  reply size = 2 words
msg = 0X102 0X54544852
reply = 0X10002 0X444f4e
Sending STP command to TIMING board
msg size = 2 words.  reply size = 2 words
msg = 0X202 0X53535450
reply = 0X20002 0X444f4e
Will verify vmeinf eprom against /vx/esi5ce/dsp/vmeinf/vme.s
VMEINF board verification status= 0, should be 0
Will verify timing eprom against /vx/esi5ce/dsp/timing/timing.s
TIMING board verification status= 0, should be 0
Will verify utility eprom against /vx/esi5ce/dsp/utility/util.s
Expecting 1 verification error: at 800081
verify error: at address 800081  expected: 000004  got: 052d79
EOF
UTILITY board verification status= 1, should be 1
EEPROMs verified correctly. Proceeding with power-up
msg size = 3 words.  reply size = 2 words
msg = 0X303 0X4c4c4441 0X0
reply = 0X30002 0X444f4e
Analog power enabled
reply[1] = 444f4e
Bias voltages have been set
Analog switches closed.  CCD is now powered-up
msg size = 2 words.  reply size = 2 words
msg = 0X302 0X43435348
reply = 0X30002 0X444f4e
Sending IDL command to TIMING board
msg size = 2 words.  reply size = 2 words
msg = 0X202 0X4949444c
reply = 0X20002 0X444f4e
value = 0 = 0x0

taskSpawn("broad_mon", 100, 0x19, 10000, broadcast_mon)
value = 14834296 = 0xe25a78
msg size = 2 words.  reply size = 2 words
msg = 0X302 0X48485452
reply = 0X30002 0X444f4e
dewar heater DAC value reset to 1638
Digital input has changed. Old value=0  New value=fef3
Digital input (mask ID 1) has changed. Old value=ffffffff  New value=1
Digital input (mask ID 1e) has changed. Old value=ffffffff  New value=9

digital input broadcast:  [0]= 2  [1]= 1  [2]= 1  [3]= 30  [4]= 9 
Digital output has changed. Old value=0  New value=4096
Digital output (mask ID 1024) has changed. Old value=-1  New value=0
Digital output (mask ID 32768) has changed. Old value=-1  New value=0
Digital output (mask ID 16384) has changed. Old value=-1  New value=0
Digital output (mask ID 512) has changed. Old value=-1  New value=0
Digital output (mask ID 256) has changed. Old value=-1  New value=0

Done executing startup script /vx/esi5ce/startup.cmd