|
AO Home Page
autocopy
backup up data
binning, CCD
calibrations
flux standards
line lists, echelle
line lists, low-D
photometric standards
wavelength plots, echelle
wavelength plots, low-D
CCD
binning
crate, rebooting
crate, troubleshooting
gain
images, troubleshooting
readout noise
specs
temperature control, turned off
CD-R disks
writing via PC
writing from UNIX
coma
coma-correction tool
coma-correction tool (revised 6/5/2001)
MAlign discussion
compass roses
computers
installing
condensation on dewar window
copymon (see also autocopy)
data
backing up
reducing
dewar window fogging
echelle mode
calibrations
order fits
recommended exposure times
sensitivity
spatial scale
wavelength solutions
wavelength finder
electronics
CCD documentation
general documentation
punch list
engineering
ESI Home Page
ESI keywords
Exabyte tapes, writing
exposure times, recommended
echelle mode
imaging mode
FACSUM
filters
new, focusing
flexure
flux standards
focus
for imaging
for spectroscopy
new filters
recommended values
FTPing data
Galil controllers
axes, Galil 0
commands
manual
troubleshooting
guider
eavesdropping
filters
hatch, troubleshooting
headers, missing
HIRES Home Page
imaging mode
coma, removing
dome flats, exposure
filters (facility)
focus, recommended values
focusing, autofoc
focusing, Malign
focusing, malacq (MAlign tool)
sensitivity
Instrument Specialists, contacting
instrument status
Instruments Home Page
instrument schedule
keywords
DCS list
ESI list
missing in headers
using in scripts
logsheets
low-dispersion mode
rotation of spectrum
sensitivity
wavelength calibration
LRIS Home Page
LWS Home Page
|
Malacq
troubleshooting
using
MAlign
calibrating
MAKEE
manuals
CCD electronics
general electronics
Observer's
motor controllers
axes, Galil 0
troubleshooting
MultiHoles
NIRC Home Page
NIRSPEC Home Page
observatory, general info
Observer's Manual
Observer's Reference Shelf
PASP paper on ESI
photometric standards
Picture Gallery
Post-Observing Comment form
problems
punch lists
electronics
mechanical
software
Quick Reference
Quick Start
rotation of low-D spectra
rotator
``Maytag'' mode
troubleshooting
scripts
keyword lists, DCS
keyword lists, ESI
setup files
shell scripts
tips
sensitivity
echelle
imaging
low-D
setup files
modifying
using
shutter
repeatability and linearity
troubleshooting
SKY
slitmasks
failed move
oscillations
testing
troubleshooting
software
dispatchers
shutdown
startup
troubleshooting
spare parts
spatial scale
echelle mode
low-D mode
specifications
CCD
general
spectraphotometric standards
starlists
startup, software
telescope
quick facts
limits
schedules
tools
troubleshooting
upper (slit) wheel
troubleshooting
Visiting Instrument Home Page
wavelength calibration
echelle mode
low-D mode
line plots
line lists
wavelength finder (echelle mode)
wavelength plots
echelle mode
low-D mode
weather links
xshow
|