Wavelengths between 3850 Å and 8850 Å.

Table 1A
Star
No.
Name RA
(2000)
Dec
(2000)
Spec
Type
AB
(5556 Å)
B-V
1 Feige 11 01:04:21.6 +04:13:37 sdB 12.07 -0.24
2 xi² Cet 02:28:09.5 +08:27:36 B9 III 4.29 -0.06
3 GD 50 03:48:50.0 -00:58:29 DA2 14.06 -0.28
4 HZ 4 03:55:21.7 +09:47:18 DA4 14.52 +0.08
5 HD 27836 04:24:12.1 +14:45:30 G1 V 7.62 +0.60
6 G191B2B 05:05:30.3 +52:49:54 DA0 11.78 -0.32
7 PG 0918+029 09:21:27.8 +02:46:06 ... 13.33 -0.27
8 GD 108 10:00:47.3 -07:33:33 sdB? 13.56 -0.22
9 G162-66 10:33:43.6 -11:41:42 DA2 13.01 -0.17
10 PG 1034+001 10:37:04.0 -00:08:20 DO 13.23 -0.37
11 Feige 34 10:39:37.6 +43:06:21 DO 11.18 -0.34
12 HD 93521 10:48:23.4 +37:34:13 O9 Vp 7.04 -0.27
13 G163-50 11:07:59.3 -05:09:10 DA4 13.06 +0.04
14 G163-51 11:08:06.3 -05:13:27 M6 V 12.58 +1.51
15 theta Crt 11:36:41.0 -09:48:08 B9.5 Vn 4.70 -0.08
16 HZ 21 12:13:56.3 +32:56:26 DO2 14.68 -0.33
17 Feige 66 12:37:23.4 +25:04:01 sdO 10.50 -0.28
18 Feige 67 12:41:51.8 +17:31:20 sdO 11.81 -0.33
19 HZ 44 13:23:34.4 +36:07:22 sdO 11.66 -0.29
20 PG 1323-086 13:25:39.4 -08:49:18 sdB-O 13.48 -0.14
21 BD+33° 2642 15:51:59.0 +32:57:01 B2 IV 10.81 -0.17
22 G153-41 16:17:55.4 -15:35:47 DA2 13.42 -0.22
23 16 Cyg B 19:41:52.0 +50:31:03 G5 V 6.20 +0.66
24 BD+28° 4211
see note
21:51:11.5 +28:51:49 Op 10.51 -0.34
25 G93-48 21:52:25.3 +02:23:32 DA3 12.74 -0.01
26 Feige 110 23:19:58.3 -05:09:56 DOp 11.82 -0.29

Notes


Table 1B
Equatorial Selected Area Stars
Star
No.
Name RA
(2000)
Dec
(2000)
V B-V Spec
Type
27 92-507 00:56:51 +01:06 11.33 0.93 G8:
28 92-508 00:56:51 +01:10 11.68 0.53 F8
29 95-52 03:54:14 -00:08 9.57 0.53 F7
30 95-86 03:52:23 +00:05 14.51 1.00 ...
31 95-132 03:54:31 +00:05 12.06 0.45 A4
32 95-218 03:54:50 +00:10 12.10 0.71 G2 V
33 95-233 03:55:56 +00:12 11.00 0.68 G2 IV
34 95-275 03:54:44 +00:27 13.48 1.76 ...
35 95-301 03:52:41 +00:31 11.22 1.29 G8 III
36 95-302 03:52:42 +00:31 11.69 0.83 G7:
37 95-317 03:53:44 +00:30 13.45 1.32 ...
38 95-330 03:54:31 +00:29 12.17 2.00 ...
39 96-736 04:52:35 +00:22 11.92 0.44 F2:
40 96-737 04:52:35 +00:22 11.72 1.33 ...
41 98-600 06:51:45 -00:26 11.11 0.57 F8
42 98-607 06:51:48 -00:26 11.15 0.16 B9
43 98-613 06:51:49 -00:27 11.81 0.17 A0
44 98-632 06:51:55 -00:26 11.54 0.15 B9
45 99-6 07:53:33 -00:50 11.05 1.26 G9: III:
46 99-8 07:53:34 -00:52 11.53 0.76 G9 IV:
47 99-12 07:53:42 -00:49 12.37 0.46 F8:
48 99-14 07:53:45 -00:49 12.54 0.88 G5:
49 101-88 09:54:42 -00:52 11.25 0.97 G8 III
50 101-207 09:59:10 -00:55 12.42 0.52 F8
51 101-327 09:56:09 -00:26 13.44 1.16 ...
52 101-329 09:56:19 -00:26 11.99 0.64 G7 V:
53 101-330 09:56:21 -00:27 13.72 0.58 ...
54 101-363 09:58:19 -00:26 9.87 0.26 A7
55 101-429 09:57:32 -00:18 13.50 0.98 ...
56 101-431 09:57:37 -00:18 13.68 1.25 ...
57 104-335 12:42:22 -00:33 11.67 0.62 G2 V
58 104-337 12:42:28 -00:34 11.22 0.77 K2 V
59 104-428 12:41:41 -00:26 12.63 0.99 ...
60 104-439 12:42:13 -00:30 11.33 0.79 G8 III
61 104-453 12:42:46 -00:26 12.24 0.77 K2 V
62 104-454 12:42:53 -00:26 11.94 0.75 K2 V
63 104-460 12:43:03 -00:28 12.89 1.29 ...
64 105-595 13:39:58 -00:29 11.62 0.69 G8 V
65 105-599 13:40:03 -00:28 11.70 0.62 G5 V
66 105-600 13:40:15 -00:29 11.84 0.56 G0
67 107-351 15:38:46 -00:32 12.34 0.56 F8
68 107-365 15:39:29 -00:30 11.60 1.10 G8 IV:
69 107-452 15:38:37 -00:23 11.04 1.07 G8 III
70 107-456 15:38:43 -00:20 12.92 0.92 ...
71 107-465 15:39:20 -00:27 11.60 0.55 F5
72 107-469 15:39:39 -00:27 12.17 0.58 F8
73 107-568 15:37:53 -00:17 13.05 1.15 ...
74 107-596 15:39:03 -00:14 11.39 0.56 F7
75 107-601 15:39:14 -00:13 14.65 1.41 ...
76 107-602 15:39:19 -00:15 12.12 0.99 G9:
77 107-619 15:39:51 -00:18 12.12 0.62 F8
78 107-626 15:40:06 -00:17 13.47 1.00 ...
79 107-627 15:40:08 -00:17 13.35 0.78 ...
80 107-990 15:38:00 +02:19 9.56 0.49 F5
81 108-468 16:36:54 -00:33 12.07 0.69 G2 V:
82 108-475 16:37:00 -00:35 11.31 1.38 K0 III
83 109-949 17:44:13 -00:02 12.83 0.81 G8:
84 109-954 17:44:15 -00:02 12.44 1.30 ...
85 109-956 17:44:17 -00:03 14.64 1.28 ...
86 109-959 17:44:18 -00:02 12.79 0.92 ...
87 110-499 18:43:07 +00:28 11.74 0.99 B9
88 110-502 18:43:10 +00:28 12.33 2.33 ...
89 110-503 18:43:11 +00:30 11.77 0.67 A0
90 110-506 18:43:19 +00:30 11.31 0.57 F8
91 110-507 18:43:19 +00:29 12.44 1.14 ...
92 111-1925 19:37:29 +00:25 12.39 0.40 A0
93 111-1965 19:37:42 +00:27 11.42 1.71 K0:
94 111-1969 19:37:44 +00:26 10.38 1.96 M5 III
95 112-805 20:42:46 +00:16 12.09 0.15 A1
96 112-810 20:42:50 +00:17 10.58 1.16 K0 III
97 112-822 20:42:55 +00:15 11.55 1.03 G8 III
98 113-221 21:40:36 +00:21 12.07 1.03 ...
99 113-241 21:41:09 +00:26 14.35 1.34 ...
100 113-260 21:41:48 +00:24 12.41 0.51 ...
101 113-339 21:40:56 +00:28 12.25 0.57 F8
102 113-342 21:41:00 +00:28 10.88 1.02 G8 III
103 113-442 21:40:40 +00:45 9.62 1.16 K2 III

Reference